Animal Experiment Instruments
Filter
Showing 1–30 of 890 results
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 68096 |
| Pricing | Available Upon Request |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DAQ |
| Pricing | Upon Request |
| Compliance | Designed for GLP-compliant respirometric studies in aquatic ecophysiology and toxicology |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | ActiMot2 – Light-Beam Frames |
| Application | Automated 3D locomotor and fine-motor activity monitoring in home-cage environments |
| Compatibility | Standard mouse/rat housing cages, CaloCage (indirect calorimetry), PhenoCage (metabolic phenotyping), PhenoMaster笼 systems |
| Calibration | Factory-calibrated |
| Detection Principle | Dual-mode infrared beam interruption (coarse locomotion + fine-motion discrimination) with configurable dead time and spatial zoning |
| Spatial Resolution | Adjustable frame geometry supporting multiple cage footprints (e.g., 20 × 20 cm to 40 × 40 cm) |
| Temporal Resolution | ≥100 Hz beam-sampling rate per channel |
| Sensor Architecture | Non-contact, solid-state IR emitter/detector pairs arranged orthogonally along X, Y, and Z axes |
| Environmental Robustness | EMI-shielded, ambient-light-immune optics |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | ActiMot2 System |
| Application | Automated In-Cage Spontaneous Locomotor Activity Monitoring for Rodents |
| Measurement Principle | Dual-Modality Infrared Beam Break + Optional InfraMot Thermal Motion Sensing |
| Cage Compatibility | Standard Home Cages, CaloCage (Indirect Calorimetry), PhenoCage (Metabolic Phenotyping) |
| Spatial Resolution | Configurable XYZ Beam Grid (X/Y: ≤10 mm spacing |
| Z | 3-layer vertical stratification) |
| Temporal Resolution | 10 ms Beam State Sampling |
| Region Definition | User-Defined Center/Periphery Zones (Open-Field Analog) |
| Motion Classification | Ambulation (Beam Crossings ≥2 Consecutive Beams) vs. Fine Motor Activity (Single-Beam Interruptions with Configurable Refractory Period ≥50 ms) |
| Calibration-Free Operation | Self-Validating Beam Array with Dynamic Baseline Adjustment |
| Obstruction Handling | Persistent Beam Block (e.g., bedding accumulation) Automatically Excluded from Activity Counting |
| Environmental Integration | Compatible with Temperature/Humidity-Controlled Vivaria and ISO 17025-Accredited Behavioral Testing Suites |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | F12003-12 |
| Price | Upon Request |
| Tip Width | 1.5 mm |
| Overall Length | 12 cm |
| Gross Weight | 0.2 kg |
| Net Weight | 21.4 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AG-2000 Series Aerosol Generator |
| Pricing | Available Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aesthesio |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aesthesio (Animal Activity Cage Sold Separately) |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NEO-9 |
| Pricing | Available Upon Request |
| Brand | Allentown |
|---|---|
| Origin | USA |
| Model | BCU-2 |
| Cage Capacity | 48 (6 × 8) |
| Frame Material | 304 Stainless Steel |
| Cage Material | Polysulfone (PSU) |
| HEPA Class | H14 (Filtration Efficiency ≥99.995% @ 0.1 µm) |
| Operating Pressure | Stable Negative Pressure (Controlled via Feedback Loop) |
| Sterilization | Autoclavable at 134°C |
| Backup Power | ≥10 h (at 50% airflow) |
| Dimensions (W×D×H) | 1466 × 651 × 1995 mm (incl. casters) |
| Weight | 148 kg (empty), 237 kg (fully loaded) |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | Discovery™ IVC |
| Regulatory Classification | Imported Medical/Research Equipment |
| Distribution Model | Authorized Distributor |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | EasyCage |
| Cage Base Area (Mouse) | 500 cm² |
| Cage Base Area (Rat) | 903 cm² |
| Feed Capacity (Mouse) | 454 g (HDPE hopper) |
| Feed Capacity (Rat) | 798 g (stainless steel wire mesh lid) |
| Water Options | 300 mL bottle (mouse), dual 300 mL bottles or automatic water (rat) |
| Material | BPA-free, recyclable PET |
| Compatibility | NexGen IVC rack platform |
| Airflow Control | Positive/negative pressure configurable |
| Structural Frame | 304 stainless steel, autoclavable at 134°C |
| Integrated Bedding | NestPak® (100 g pre-filled with ALPHA-dri®, corn cob, or Performance BioFresh™) |
| Ergonomic Features | Snap-fit assembly, visual docking indicators, lightweight design |
| Brand | Allentown |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ferret Isolator System |
| Pricing | Available Upon Request |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | NexGen |
| Construction | 304 Stainless Steel Frame |
| Sterilization Compatibility | Autoclavable at 134°C |
| Cage Material | Polysulfone (High-Transparency, USP Class VI Compliant) |
| System Integration | EcoFlo™ Blower, WiVarium Plus™ Wireless Monitoring, Sentinel™ Health Surveillance, Wi-Com Sensus™ RFID Tracking |
| Compliance | CCAC, AAALAC, NIH Guide, EU Directive 2010/63/EU |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | Sentry SPP |
| Construction | 304 Stainless Steel Frame |
| Filtration | Dual Certified HEPA (Supply & Exhaust, Optional) |
| Sterilization | Autoclavable at 134°C |
| Power Backup | ≥10-hour Battery Redundancy |
| Cage Sizes | Mouse (537 cm² floor area), Rat (916 cm² floor area) |
| Sealing System | Patented 4-Point Automatic Seal (US Patent 6,308,660) |
| Docking Interface | SmartDock® Visual Alignment System |
| Compliance | Meets NIH Guide, AAALAC International standards, supports GLP/GMP-aligned animal facility operations |
| Brand | Alzet |
|---|---|
| Origin | USA |
| Type | Implantable Osmotic Delivery Device |
| Dimensions | ~19.7 mm × 5.6 mm (cylindrical capsule) |
| Delivery Duration | Up to 28 days (model-dependent) |
| Flow Rate Range | 0.11–10.0 µL/h (varies by model) |
| Reservoir Volume | 100–200 µL (model-dependent) |
| Material Compliance | USP Class VI-certified ethylene-vinyl acetate (EVA) and polyurethane |
| Sterilization | Ethylene oxide (EtO) |
| Biocompatibility | ISO 10993-1 tested |
| Operating Temperature | 37 °C (in vivo) |
| Accuracy | ±10% over specified duration |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | 68601 (Mouse), 68602 (Rat) |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | F660 |
| Price Range | USD 140 – 700 |
| Filtration Capacity | Fluosorber™ Sorbent Cartridge (Initial Mass: 1200 g |
| Replacement Threshold | ≥1400 g) |
| Absorbed Agents | Sevoflurane, Isoflurane, Halothane (CF₃CHClBr) |
| Not Absorbed | Nitrous Oxide (N₂O) |
| Flow Rate Range | 8–60 L/min |
| Noise Level | <20 dB(A) |
| Display | Color Touchscreen with Real-time Flow & Pressure Monitoring |
| Compliance | Designed for alignment with OSHA 1910.134, NIOSH REL (2 ppm TWA for isoflurane/sevoflurane), and institutional EH&S requirements |
| [Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Models | 80098, 80099, 80100 |
| Pricing | Available Upon Request |
| Dimensions & Absorption Capacity | 80098 — 30 × 45 cm, 100 pcs/pack, 200 mL absorption |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Animal Treadmill |
| Pricing | Upon Request |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CHIRAD |
| Max. Operating Voltage | 160 kV |
| Max. Power Output | 4000 W |
| SSD Range | 20–70 cm (customizable chamber) |
| Filter Configuration | Standard 2 mm Al + 0.3 mm Cu drawer-type filter set |
| Dose Uniformity | ≥95% |
| Exposure Time Range | 1–9999 s |
| Ambient Dose Rate (5 cm from housing) | <20 µR/h |
| Sample Compatibility | Cells, tissues, organs, bacteria, mice, rats, nanomaterials, food, seeds, insects |
| Environmental Control Option | Integrated biological incubator module |
| Safety Compliance | Meets GBZ 125–2022 and GB 18871–2002 radiation safety standards |
| Data Export | Excel-compatible CSV output |
| Touch Interface | 15.6″ industrial capacitive touchscreen with real-time ionization chamber dose monitoring |
| Shielding | Self-shielded irradiation chamber with dual-redundant interlock system (door, beam gate, emergency stop) and audible/visual fault alerts |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ChiRad 225 |
| Pricing | Upon Request |
| Maximum Tube Voltage | 225 kV |
| Tube Current | 13 mA |
| System Power | 3000 W |
| Focal Spot Size (EN) | 5.5 mm |
| Inherent Filtration | 0.8 mm Be |
| Beam Divergence Angle | 40° |
| Useful Beam Diameter | 40 cm |
| Source-to-Object Distance Range | 13–65 cm |
| Exposure Time Range | 1–9999 s |
| Electrical Supply | 220 V, 50 Hz, Single-phase, 9 kVA |
| Cooling System | Integrated Closed-loop Heat Exchanger |
| Sample Stage | Motorized Vertical Adjustment & Rotation (2 RPM) |
| Leakage Radiation | <0.5 µSv/h at 10 cm from surface (at max energy) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Model | SmallFocus |
| Pricing | Available Upon Request |
| Tube Voltage Range | 20–90 kV |
| Focal Spot Size | 5 µm |
| Active Imaging Area | 325 mm × 325 mm |
| Flat-Panel Detector Resolution | 100 µm |
| Chamber Material | Stainless Steel |
| Exposure Control | Fully Automated One-Touch Exposure |
| Remote Diagnostics | Integrated Ethernet-Based Support |
| Image Processing | Dedicated Workstation Included |
| Brand | Smith |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APEX |
| Price | $1 (Reference Only) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 10–90% RH |
| Altitude Range | −400 to 3000 m |
| Dimensions (H×L×W) | 30.5 × 52 × 44.5 cm |
| Weight | 24 kg |
| Output Power | 7200 W continuous, 24,000 W peak |
| Output Voltage | 0–1200 VDC / 0–240 VRMS AC |
| Frequency Range | 1–1000 Hz |
| Waveforms | DC, Pulsed DC, Burst DC, AC |
| Onboard Data Logging | Peak/Avg Voltage, Current, Power, Waveform Parameters, GPS Coordinates, Timestamp, Internal Temperature, Altitude, Error Codes |
| Display | Sunlight-readable color LCD |
| Safety | Footswitch + Emergency Stop |
| Memory | 12 Predefined Waveform Profiles |
| Environmental Rating | IP54-equivalent enclosure for field use |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | 597316 |
| Category | Research-Grade Physiological Salt Solution for Ex Vivo Neural Tissue Preparation |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | CM-191 |
| Measurement Principle | Antimony Electrode Potentiometry (pH 4.00–9.00) & Glass Electrode Potentiometry (pH 0.00–14.00) |
| Temperature Compensation | Automatic/Manual (0°C to 100°C) |
| Input Impedance | >10¹³ Ω |
| Resolution | 0.01 pH / 1 mV |
| Accuracy (pH) | ±0.01 pH |
| Accuracy (mV) | ±1 mV |
| Display | Digital LCD |
| Power Supply | AC 100 V, 50/60 Hz (12 V DC adapter) |
| Power Consumption | ~1 VA |
| Dimensions (W×D×H) | 165 × 180 × 70 mm |
| Weight | ~1000 g |
| Data Output | 0–1.4 V analog signal (compatible with external data loggers) |
| Standard Accessories | pH 4.01 & 6.86 calibration buffers (1× each), 12 V AC adapter, 0–100°C thermometer |
| Optional Electrodes | CMS-191 antimony micro-catheter electrode (1.0 mm OD), CM-181 glass electrode (2.4 mm OD) |
| Brand | Asylum Research |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Rodent Metabolic Monitoring System |
| Model | Mice Metabolic Cage |
| Dimensions (L×W×H) | 210 × 210 × 400 mm |
| Material | Polycarbonate (PC), autoclavable at 120°C |
| Urine Collection Capacity | 15 mL |
| Water Bottle Capacity | 880 mL |
| Grid Aperture | Ø1 mm |
| Compliance | ISO 9001-certified manufacturing process |
| Sterilization | Compatible with steam autoclaving (120°C, 20 min) |
| Brand | Asylum Research |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Laboratory Animal Housing |
| Model | G-12 |
| Unit Price | USD 1,280 |
| Cage Layout | 3 columns × 4 rows = 12 individual units |
| Single Cage Dimensions | 500 × 400 × 260 mm (L×W×H) |
| Full Rack Dimensions | 2000 × 650 × 1720 mm (L×W×H) |
| Material | AISI 304 stainless steel |
| Components Included | Feed hopper, gravity-fed water bottle with stainless steel sipper tube, removable waste tray, integrated water reservoir |
| Compliance | Designed to meet NIH Guide for the Care and Use of Laboratory Animals, AAALAC International housing standards, and ISO 55000-aligned facility maintenance protocols |
