| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | F-CAL |
| Measurement Principle | Heat Flow Method |
| Thermal Resistance Range | 1×10⁻⁵ m²·K/W |
| Repeatability | <2% fluctuation |
| Test Atmosphere | Ambient air |
| Hot-Side Temperature Setting | 50°C |
| Sample Geometry | Square, 25 mm or 40 mm edge length, thickness 1–5 mm |
| Instrument Type | Steady-State Thermal Resistance Analyzer |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LaserPIT |
| Instrument Type | Laser Flash Method (AC-mode variant) |
| Temperature Range | Ambient to 200 °C |
| Sample Dimensions (Bulk) | 2.5–5 mm width × 30 mm length × 3–500 µm thickness |
| Sample Dimensions (Thin Films on Substrates) | 2.5–5 mm width × 30 mm length × 100–1000 nm thickness |
| Measurement Atmosphere | Vacuum (< 0.02 Pa) |
| Film Analysis Capability | Differential AC-mode thermal diffusivity extraction for anisotropic and substrate-supported thin films |
| Brand | Advance Riko |
|---|---|
| Origin | Japan |
| Model | TC-1200RH |
| Measurement Principle | Laser Flash Method (LFM) |
| Temperature Range | RT to 1150 °C (up to 1200 °C short-term) |
| Thermal Conductivity Range | 0.1–2000 W/m·K |
| Accuracy | ±5% |
| Repeatability | ±3% |
| Sample Dimensions | Ø10 mm × 1–3 mm (thickness), measured through-thickness |
| Atmosphere | Vacuum (standard) |
| Heating Rate | 10 °C/min (to 100 °C), 20 °C/min (to 300 °C), 50 °C/min (to 1150 °C) |
| Dimensions (W×D×H) | 900 × 1050 × 1700 mm |
| Weight | ~350 kg |
| Power Supply | AC200 V, single-phase, 8 kVA (main unit) |
| Cooling Water | ≥5 L/min, pressure ≥0.15 MPa |
| Compliance | JIS R 1611, JIS R 1650-3, JIS H 7801, ISO 13826, ASTM E1461 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | TCA-3030 |
| Measurement Principle | Guarded Hot Plate Method (ASTM C177 / ISO 8302 / GB/T 10294-2008) |
| Thermal Conductivity Range | 0.01–1 W/(m·K) |
| Accuracy | ≤1% |
| Repeatability | ≤1% |
| Temperature Range (Cold Plate) | 5–90 °C |
| Max. Hot Plate Temperature | 120 °C |
| Sample Dimensions | 300 mm × 300 mm, Thickness ≤37.5 mm |
| Sample Form | Solid, Homogeneous Flat Panels |
| Test Environment | Ambient (Controlled Room: 8–35 °C, RH <80%) |
| Power Supply | 3 kW, 220 V AC |
| Overall Dimensions (L×W×H) | 1120 × 830 × 1600 mm |
| Automation | Microprocessor-Controlled with Real-Time Data Acquisition & Reporting |
| Compliance | Fully aligned with GB/T 10294-2008, ASTM C177, ISO 8302, and EN 12664 for steady-state thermal resistance measurement |
| Brand | Aiyao Instruments |
|---|---|
| Model | TCT |
| Measurement Principle | 3ω Method |
| Sample Form | Micro/Nano Thin Films (Supported & Freestanding) |
| Temperature Range | Ambient to 400 °C (Optional Cryogenic Extension Available) |
| Thermal Conductivity Range | 0.1–1000 W/(m·K) |
| Resolution | <0.5% of Full Scale |
| Data Acquisition | High-Precision Digital Source Meter + Dual-Phase Lock-in Amplifier |
| Compliance | ASTM E1461, ISO 22007-2 (Adapted), GLP-Compatible Audit Trail Logging |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | PHASE12 |
| Compliance | JEDEC JESD51-1, JESD51-14, JESD51-8, JESD51-12 |
| Thermal Resolution | ±0.007°C |
| Junction Temperature Accuracy | ±0.1°C |
| Voltage Measurement Accuracy | ±0.25% (0–30 V) |
| Current Measurement Accuracy | ±0.25% |
| Sampling Rate | 1 MHz |
| Max Standard Current Output | 18 A |
| Optional High-Current Power Booster | up to 1000 A |
| Junction Sensing Current Options | 1–50 mA |
| Calibration Temperature Range | Ambient to 180°C |
| Input Power | 220 VAC, 5 A, 50/60 Hz |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | TIM1300 / TIM1400 |
| Test Method | ASTM D5470 |
| Sample Diameter | 1.3 in (33 mm) |
| Thickness Range | 0–20 mm |
| Temperature Range | 20–65°C (TIM1300), 20–130°C (TIM1400) |
| Contact Pressure Range | 5–380 psi (34–2600 kPa) |
| Thickness Measurement Accuracy | ±1% + 0.001 in (±25 µm) |
| Thermal Resistance Range | 0.005–8 K/W |
| Power Supply | 100–230 VAC, 50/60 Hz |
| Cooling Requirement | 6 L/min @ 10–35°C, ±0.1°C stability |
| Compressed Air | ≥90 psi (600 kPa), 10 µm filtration |
| Dimensions (H×W×D) | 58×41×43 cm |
| Weight | 19 kg (TIM1300), 21 kg (TIM1400) |
| Brand | ANALYSIS TECH |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | TIMTester 1300, TIMTester 1400 |
| Pricing | Upon Request |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Trident Film |
| Instrument Type | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | Better than 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | Better than 1% |
| Compliance | ISO 22007-2, ASTM D7984, GB/T 32064 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident HotDisk |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | Better than 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | Better than 1% |
| Standards Compliance | ISO 22007-2, ASTM D7984, ASTM D5334, ASTM D5930, GB/T 32064 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident MTPS |
| Measurement Principle | Modified Transient Plane Source (MTPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | < 1% |
| Thermal Diffusivity Range | 0 – 1200 mm²/s |
| Specific Heat Capacity Range | 0 – 5 MJ/m³·K |
| Effusivity Range | 0 – 40,000 W·s⁰·⁵/m²·K |
| Test Duration | 0.8 – 180 s |
| Compliance | ISO 22007-2, ASTM D7984, ASTM D5334, ASTM D5930, GB/T 32064 |
| Brand | C-Therm |
|---|---|
| Model | TCi |
| Measurement Principle | Transient Plane Source (TPS) – Multi-Method Platform (MTPS, Flex TPS, Needle TLS) |
| Origin | Canada |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Repeatability | < 1% |
| Thermal Conductivity Range | 0–2000 W/m·K |
| Thermal Diffusivity Range | 0–1200 mm²/s |
| Specific Heat Capacity Range | up to 5 MJ/m³·K |
| Effusivity Range | 5–40,000 W·s⁰·⁵/m²·K |
| Standards Compliance | ASTM D7984, ASTM D5334, ASTM D5930, ISO 22007-2.2, GB/T 32064, IEEE 442 |
| Brand | C-Therm |
|---|---|
| Model | Trident |
| Measurement Principle | Integrated Modified Transient Plane Source (MTPS), Flexible Transient Plane Source (Flex TPS), and Transient Line Source (TLS Needle) |
| Thermal Conductivity Range | 0–2000 W/m·K |
| Accuracy | <5% |
| Repeatability | <1% |
| Operating Temperature Range | –50°C to +500°C |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Compliance | ASTM D7984, ISO 22007-2.2, ASTM D5334, ASTM D5930, IEEE 442, GB/T 32064 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Flex TPS |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | < 1% |
| Standards Compliance | ASTM D7984, ISO 22007-2.2, GB/T 32064, ASTM D5334, ASTM D5930, IEEE 442 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident TPS |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Thermal Diffusivity Range | 0 – 1200 mm²/s |
| Specific Heat Capacity Range | 0 – 5 MJ/m³·K |
| Effusivity Range | 0 – 40,000 W·s⁰·⁵/m²·K |
| Repeatability | < 1% |
| Test Duration | 0.8 – 180 s |
| Compliance | ISO 22007-2:2015, GB/T 32064-2015 |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Trident |
| Price Range | USD 65,000–105,000 |
| Instrument Type | Transient Plane Source (TPS) / Flexible TPS / Transient Line Source (TLS) |
| Dimensions (L×W×H) | 300 × 300 × 212 mm |
| Accuracy | ±1% |
| Thermal Conductivity Range | 0–500 W/(m·K) |
| Repeatability | High |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample mode |
| Test Environment | Ambient temperature operation |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Resolution | 0.00001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±1% |
| Temperature Range | −30 °C to 200 °C |
| Sample Forms | Solids (bulk, metallic, thin films), powders, granules, liquids, gels, pastes, and insulating materials |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Minimum Solid Sample Dimensions | 15 mm × 15 mm × 7.5 mm (Probe #1) |
| Liquid/Powder Sample Volume | 18 mL via dedicated fixture |
| Measurement Time | ≤160 s per test |
| Power Consumption | <300 W |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample per test |
| Test Environment | Ambient temperature (with optional environmental chamber integration) |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Temperature Range | –30 °C to 200 °C |
| Resolution | 0.00001 W/(m·K) |
| Repeatability | ≤1% RSD |
| Accuracy | ±2% (traceable to NIST-certified reference materials) |
| Sample Forms | Solids (bulk, thin films, foams), liquids, powders, pastes, gels, and elastomers |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Minimum Solid Sample Dimensions | 15 mm × 15 mm × 7.5 mm (Probe #1) |
| Liquid/Powder Sample Volume | 18 mL via dedicated fixture |
| Measurement Time | ≤160 s per test |
| Power Consumption | <300 W |
| Display | 7-inch color capacitive touchscreen interface |
| Control Architecture | Bidirectional software–instrument communication (USB/Ethernet) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-AS |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–50 W/(m·K) |
| Temperature Range | −40 °C to 200 °C |
| Accuracy | ±0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Measurement Time | ≤160 s |
| Sample Forms | Solids (blocks, metals, films), Liquids, Powders, Gels, Pastes, and Insulating Materials |
| Sample Requirements | Surface must be flat and smooth |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Power Consumption | <300 W |
| Solid Sample Dimensions (Probe #1) | ≥15 mm × 15 mm × 3.75 mm |
| Solid Sample Dimensions (Probe #2) | ≥30 mm × 30 mm × 7.5 mm |
| Liquid/Powder Sample Volume | 18 mL (with dedicated fixture) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Domestic Instrument Manufacturer |
| Model | DZDR-AS |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample per test |
| Operating Environment | Ambient temperature |
| Thermal Conductivity Range | 0.0001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±0.0001 W/(m·K) |
| Temperature Range | −40 °C to 200 °C (expandable) |
| Sample Form Compatibility | Solid blocks, metals, liquids, powders, gels, pastes, thin films, thermal insulation materials, alloys, ores, polymers, and foams |
| Test Duration | <160 s |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Sample Dimensions | Probe #1: 7.5 × 7.5 × 3.75 mm |
| Probe #2 | 15 × 15 × 7.5 mm |
| Power Supply | AC 220 V |
| Max. Power Consumption | <300 W |
| Max. Sample Temperature Rise | <20 °C |
| Probe Power Range | Probe #1: 0–1 W |
| Probe #2 | 0–15 W |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient temperature |
| Thermal Conductivity Range | 0.0001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Temperature Range | −40 °C to +200 °C (expandable) |
| Sample Forms | Solid blocks, metals, liquids, powders, pastes, gels, thin films, foams, polymers, alloys, minerals, and thermal insulation materials |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient temperature |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±0.00001 W/(m·K) |
| Test Atmosphere | Ambient air (no controlled atmosphere) |
| Temperature Range | −30 °C to 200 °C |
| Sample Forms Supported | Solids (bulk, metallic), liquids, powders, pastes, gels, thin films, and aerogels |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-S |
| Instrument Type | Transient Plane Source Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient temperature (standard) |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Sample Forms | Solid blocks, pastes, granular solids, gels, liquids, powders, coatings, thin films, and thermal insulation materials |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DRX-II-300A |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Guarded Hot Plate Method |
| Measurement Range | 0.01–2.2 W/m·K |
| Repeatability | ±1.0% |
| Accuracy | ±2.5% |
| Thickness Capacity | Up to 200 mm |
| Cold Plate Temp Range | −40 °C to +60 °C |
| Hot Plate Temp Range | Ambient to 110 °C (optional up to 300 °C or 600 °C) |
| Temperature Control Precision | ±0.1 °C |
| Temp Resolution | 0.01 °C |
| Sample Size | 200 × 200 × (5–20) mm or 300 × 300 × (5–100) mm |
| Power Supply | AC 220 V ±5%, 3.0 kW |
| Compliance | GB/T 10294–2008, ASTM C518, ISO 8302 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DRH-300 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Guarded Hot Plate Method |
| Dimensions (L×W×H) | 820 × 760 × 950 mm |
| Accuracy | ±2% |
| Thermal Conductivity Range | 0.001–2.20 W/(m·K) |
| Repeatability | ±1% |
| Sample Thickness Range | 5–50 mm |
| Sample Size | 300 × 300 mm |
| Cold Plate Temp. Range | 0–60 °C (0.01 °C resolution) |
| Hot Plate Temp. Range | 10–99.9 °C |
| Temperature Uniformity (Hot/Cold Plates) | ≤0.1 °C |
| Surface Flatness Tolerance | ≤0.5 mm |
| Applied Pressure Range | 0–80 kPa (0.1 kPa resolution) |
| Power Supply | AC 220 V ±5%, 3.0 kW |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DRH300 |
| Quotation | USD 7,650 (FOB) |
| Instrument Type | Guarded Hot Plate Method |
| Dimensions (L×W×H) | 1200 × 700 × 1300 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.005–3.0 W/(m·K) |
| Repeatability | 1% |
| Temperature Control Range (DRH300A/B/C variants) | 0–40 °C / RT–100 °C / −20–70 °C |
| Sample Size Max | 300 × 300 × 100 mm |
| Thermal Resistance Range | 0.1–8.0 m²·K/W |
| Control System | Peltier-based heated/cooled plates with dual embedded heat flux sensors |
| Compliance | ASTM C518, ISO 8301, GB/T 10294, GB/T 10295, JIS A 1412, DIN EN 12939, DIN EN 13163, DIN EN 12667 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DRX-I-JH |
| Pricing | Available Upon Request |
| Max Operating Temperature | RT–600°C / RT–1000°C (configurable) |
| Thermal Conductivity Range | 0.035–40 W/(m·K) and 20–500 W/(m·K) (material-dependent) |
| Sample Geometry | Cylindrical rods (Ø5 × 220 mm for metals |
| Wire Samples | Ø1–3 mm diameter |
| Sample Quantity | ≥2 per test run |
| Measurement Accuracy | ≤5% (typical), down to ±2% under optimized calibration and controlled conditions |
| Vacuum/Atmosphere Control | Customizable (high-vacuum or inert gas purge options) |
| Automation | Fully computer-controlled heating ramping, data acquisition, real-time calculation, and report generation |
| Power Supply | 220 V AC, ≤4 kW total consumption |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DRX-I-RX |
| Price Range | USD 1,400–7,200 (FOB) |
| Instrument Type | Transient Hot Wire Method (THW) |
| Dimensions (L×W×H) | 110 × 150 × 65 cm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.015–20 W/(m·K) |
| Repeatability | ±2% |
| Max Test Temperature | 1000 °C / 1400 °C / 1600 °C (configurable) |
| Sample Size Limit | 230 × 114 × 65 mm |
| Heating Power Control | Programmable & Computer-Regulated |
| Dual-Mode Capability | Cross-Wire & Parallel-Wire THW |
| Software Platform | Windows 7/XP-based thermal analysis application with automated data acquisition and report generation |
| Optional Modules | Specific Heat Capacity Measurement Module (accuracy: ±7–10%), Transient Line Source (TLS), and Needle Probe Method Adapters |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DRX-II-LUX |
| Price | Upon Request |
| Measurement Principle | Steady-State Guarded Hot Plate (Modified ASTM C177 / ISO 8302 compliant architecture) |
| Heat Plate Diameter | Φ65 mm |
| Heat Plate Temp | 60 ± 0.1 °C (Pt100 controlled) |
| Cold Plate Temp | 20 ± 0.1 °C (water-cooled, Pt100 controlled) |
| Preheater Temp | 40 °C (optional) |
| Coolant Temp Control | 20 ± 0.5 °C |
| Coolant Flow Rate | 40 L/h |
| Temperature Differential Resolution | ±0.1 °C (via differential thermopile or dual Pt100) |
| Sample Dimension | Φ50 × 50 mm |
| Thickness Measurement Accuracy | ±0.01 mm (digital caliper) |
| Test Duration | 5–20 min |
| Contact Pressure | Manual or motorized preloading system |
| Max Power Consumption | ≤1.5 kW |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DRX-II-RL |
| Pricing | Available Upon Request |
| Temperature Range Options | −196 °C to RT, −30 °C to 90 °C, −20 °C to 70 °C, 0 °C to 40 °C, 0 °C to 100 °C |
| Temperature Resolution | 0.01 °C |
| Sample Diameter | Φ10–30 mm |
| Sample Thickness | 0.02–50 mm |
| Thermal Resistance Range | 0.1–8.0 m²·K/W |
| Thermal Conductivity Range | 0.015–100 W/(m·K) and 0.015–40 W/(m·K) |
| Accuracy | ≤±3% (thermal conductivity), ±5% (thermal diffusivity), ±7% (specific heat) |
| Repeatability | 0.3–0.5% |
| Cooling Options | Forced-air, External Water Bath, Liquid Nitrogen |
| Control | Motorized Plate Actuation, Programmable Temperature Ramp (1–10 setpoints), Embedded Controller + PC Interface |
| Compliance Standards | ASTM D5470-06, ASTM E1530, ASTM C518, ISO 8301, JIS A1412, DIN EN 12939, DIN EN 13163, DIN EN 12667, MIL-I-49456A |