Petroleum Specialized Analytical Instruments
Filter
Showing 1–30 of 344 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RVP4500 Series |
| Pricing | Available Upon Request |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | CB10 |
| Compliance | ASTM D665, ASTM D7548, NACE TM0172, IP 135, ISO 7120, JIS K2510 |
| Test Positions | 2 independent stations |
| Automation Level | Fully automated water injection, temperature ramping, stirring, specimen immersion & retrieval |
| Interface | Touchscreen with embedded calibration datasets |
| Safety | Direct-drive low-torque motor with immediate stall detection and emergency stop |
| Integration | Compatible with CT10 Corrosion Rating Station for end-to-end automated evaluation |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | SP10 |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 1 kPa (typical ambient reference) |
| Temperature Control Resolution | 0.1 °C |
| Test Duration | <10 min |
| Flame Height Resolution | 0.1 mm |
| Connectivity | Ethernet (RJ45), USB (2 ports), Optional Printer via USB |
| Dimensions (W×D×H) | 330 × 390 × 413 mm |
| Weight | 10 kg |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | SP20 |
| Compliance | ASTM D1322, GB/T 3822 |
| Measurement Principle | Optical flame morphology detection with real-time height quantification |
| Test Duration | < 10 min per sample |
| Height Resolution | 0.1 mm |
| Data Storage Capacity | Up to 1,000,000 results |
| Connectivity | Ethernet, RS-232, USB |
| Display | 8-inch full-color touchscreen |
| Dimensions (L×W×H) | 330 × 390 × 413 mm |
| Integrated Sensors | Barometric pressure, ambient temperature, relative humidity |
| Fuel Calibration | Pre-loaded standard fuel database with auto-compensated smoke point correction |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | TO10 |
| Test Standards | ASTM D3241, GB/T 9169, IP 323, ISO 6249 |
| Temperature Range | 100–380 °C |
| Pressure Drop Range | 0–750 mmHg (auto-bypass +700 mmHg) |
| Test Duration | 4–600 min |
| Air Flow Rate | 1.5 L/min (programmable) |
| Fuel Flow Control | Dual 5 mL syringe pumps (±1% accuracy) |
| Temperature Sensing | Class 1 K-type thermocouples |
| Cooling Method | Peltier + heat pipe (liquid-free) |
| Dimensions | 440 × 600 × 670 mm |
| Weight | 60 kg |
| Power Supply | 100–240 V, 8 A, 50/60 Hz |
| Operating Ambient | +10 to +35 °C |
| Connectivity | Ethernet (RJ45), USB ×2, optional USB printer |
| Data Storage | Integrated DR10 ITR interface with automated result transfer via Ethernet |
| Brand | AD SYSTEMS |
|---|---|
| Origin | France |
| Model | DR10 |
| Measurement Principle | Optical Interferometry |
| Thickness Range | 0–1200 nm |
| Volume Range | 0–0.5 mm³ |
| Measurement Points per Tube | 1200 |
| Scan Time | ≤15 min |
| Data Storage Capacity | Up to 100,000 records (internal database) |
| Interface | Ethernet (RJ45), USB 2.0 (for printer/data export), LAN/LIMS compatible |
| Dimensions (W×D×H) | 250 × 160 × 290 mm |
| Weight | 10 kg |
| Power Supply | 115–230 V AC, 2 A, 50/60 Hz |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | DT100 |
| Operating Principle | Digital Spot Test Image Analysis |
| Measurement Parameters | IC (0.1–5%), MD (0–100), DP (0–200) |
| Spot Acquisition Time | ~3 min per spot |
| Max Spots per Filter Paper | 16 |
| Imaging System | CCD digital camera with LED backlighting |
| Calibration | On-site using included calibration kit |
| Data Storage | USB drive, LAN network, or local printer (optional) |
| Interface | USB 2.0, RJ45 Ethernet |
| Dimensions | 305 × 487 × 390 mm |
| Weight | 20 kg |
| Power Supply | 230 V, 2 A, 50/60 Hz |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | VD10 |
| Operating Pressure | Atmospheric |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–65 °C |
| Distillation Rate | 2–10 mL/min |
| Volume Detection Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Brand | AYALYTICAL |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AgDDI |
| Price | Contact for Quote |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AcceleSep Petroleum Fraction Rapid Separation System |
| Pricing | Upon Request |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | 682T-HP |
| Sample Temperature Range | Up to 200°C (392°F) |
| Maximum Sample Pressure | >1500 psig |
| Optical Path Window Diameter | 5 cm |
| Sulfur Detection Range | 0.02–6.0 wt% |
| Application Focus | Crude Oil, Heavy Hydrocarbons, Pipeline Streams, Refinery Blending Processes |
| Compliance | Designed to meet internal industry specifications for refinery and midstream process monitoring |
| Brand | Ankersmid |
|---|---|
| Origin | Germany |
| Model | OilHealth Probe |
| Type | Online Instrument |
| Application | Lubricating Oil Condition Monitoring |
| Core Technology | Multi-parameter Spectroscopic Analysis (FTIR + Electrochemical RULER + Viscosity Correlation) |
| Compliance Context | Designed for ISO 4406, ASTM D7883 (RULER), ASTM E2412 (FTIR), and OEM lubricant life extension protocols |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest GmbH, a company of Anton Paar) |
| Product Category | Imported |
| Model | BPA |
| Price | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PNR 12 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | TAG 300/500 |
| Detection Method | Closed-Cup (TAG) |
| Operation Mode | Fully Automatic |
| Sample Temperature Range | −35 °C to +130 °C |
| Ignition Source | Ceramic-Coated Electric Igniter |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | Aquamax KF PRO LPG |
| Application | Coulometric Karl Fischer titration for trace moisture determination in pressurized liquefied gases (LPG, LNG) and vapor-phase hydrocarbon streams |
| Detection Range | 0.1–1000 µg H₂O (equivalent to 0.1–500 ppmv in gas phase, depending on sample volume and density) |
| Sample Form | Liquid or vapor-phase, pressurized |
| Automation Level | Fully automated sample introduction, titration, rinsing, and method execution |
| Compliance | Designed per ISO 8573-3, ASTM D6304, ASTM D7429, and EN 15472 |
| Brand | Arrow Grand Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC-IR2 |
| Pricing | Available Upon Request |
| Measurement Principle | Semiconductor Mid-IR Laser Absorption Spectroscopy Coupled with High-Resolution Capillary Gas Chromatography |
| Isotopes Measured | δ¹³C of CH₄ (C1), C₂H₆ (C2), C₃H₈ (C3), and n-C₄H₁₀ (C4) |
| Precision (δ¹³C) | <0.4 ‰ (30-day stability, no calibration gas) |
| Sample Throughput | One complete isotopic profile per 5 minutes |
| Detection Limits | CH₄ ≥ 0.5% v/v |
| CO₂ Concentration Accuracy | ±0.01% (full scale) |
| Total Carbon Compound Concentration Accuracy | ±0.01% |
| Spectral Acquisition Rate | 4 Hz |
| Dead Volume | <0.1 mL |
| Calibration Gas | CO₂ standard required for high-precision mode |
| Power Supply | 110/220 V AC, 1 kW average, 3 kW peak |
| Operating Temperature | 0–35 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| [Brand | AST |
|---|---|
| Origin | Shanghai, China |
| Model | DM8116 |
| Detection Target | Total Sulfur |
| Detection Limit (300 s) | 0.33 ppm |
| X-ray Tube | Ag anode, ≤50 kV / ≤2 mA / ≤50 W, micro-focus, thin Be window |
| Crystal | Logarithmic Spiral Doubly Curved Crystal (LSDCC) |
| Detector | Ultra-thin Be window proportional counter |
| Standards Compliance | GB/T 11140, ISO 20884, SH/T 0842, ASTM D2622, ASTM D7039, ASTM D7220 |
| Measurement Range | 3×LOD to 9.99 wt% |
| Analysis Time | 1–999 s (recommended: 300 s for trace, 60 s for major) |
| Operating Environment | 5–40 °C, ≤85% RH at 30 °C, 220 V ±20 V, 50 Hz, ≤200 W |
| Dimensions & Weight | 330 × 460 × 350 mm, 25 kg] |
| Brand | ASTEL/ST |
|---|---|
| Origin | Shanghai, China |
| Model | DM1260 |
| Detection Method | Total Sulfur Quantification |
| Detection Limit (300 s) | 3.9 ppm |
| Compliance | GB/T 17040–2019, GB 17411, ASTM D4294 |
| X-ray Tube | ≤20 kV, ≤1 mA, ≤10 W |
| Detector | Ultra-thin Be-window Proportional Counter |
| Measurement Range | 3×LOD to 9.99 wt% S |
| Analysis Time | 1–999 s (recommended: 100 s for major, 300 s for trace) |
| Operating Environment | 5–40 °C, ≤85% RH at 30 °C, 220 V ±20 V, 50 Hz, ≤100 W |
| Dimensions & Weight | 300 × 410 × 165 mm, 10 kg |
| Brand | ASTEL / ST |
|---|---|
| Origin | Shanghai, China |
| Model | DM2400S/Cl |
| Detection Elements | Total Sulfur (S), Total Chlorine (Cl) |
| Detection Limits (300 s) | S: 0.26 ppm, Cl: 0.18 ppm |
| X-ray Tube | Ag-target, micro-focus, thin Be window, ≤50 kV / ≤2 mA / ≤50 W |
| Detector | Silicon Drift Detector (SDD), 20 mm² active area, ≤123 eV resolution at Mn Kα, ≤2 Mcps count rate |
| Primary Optic | Logarithmic Spiral Doubly Curved Crystal (LSDCC) artificial monochromator |
| Standards Compliance | GB/T 11140, ISO 20884, ASTM D2622, ASTM D7039, ASTM D7220, ASTM D4929, ASTM D7536, ISO 15597 |
| Measurement Range | 3×LOD to 9.99 wt% |
| Linear Correlation Coefficient (r) | >0.999 for both S and Cl calibration curves |
| Repeatability (r) & Reproducibility (R) | Meets or exceeds all referenced ASTM/ISO/GB standards |
| Operating Environment | 5–40 °C, ≤85% RH (at 30 °C), 220 V ±20 V, 50 Hz, <200 W |
| Dimensions & Weight | 330 × 460 × 350 mm, 25 kg |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 256000/M, ASTM D6 |
| Power Supply | 220 V / 50 Hz, 2000 W |
| Temperature Range | Ambient to 180 °C ± 1 °C |
| Temperature Control Accuracy | ±0.1 °C (PID + Pt100 RTD) |
| Rotational Speed | 5.5 rpm (adjustable 5–6 rpm) |
| Internal Chamber Dimensions | 60 × 80 × 80 cm (W × H × D) |
| Net Weight | ~30 kg |
| Safety Certification | CE |
| Compliance Standards | ASTM D6, ASTM D1754, IP 145 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AD0972-100 |
| Pricing | Available Upon Request |
| Brand | ASTRO / ST |
|---|---|
| Origin | Shanghai, China |
| Model | DM1262 |
| Detection Method | Total Sulfur (S) by Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Detection Limit (300 s, air atmosphere) | 2.6 ppm |
| Weight (incl. battery & thermal printer) | 5.6 kg |
| Measurement Range | 3×DL to 9.99 wt% S |
| Linearity Coefficient (r) | >0.999 across low/mid/high calibration ranges |
| Repeatability (r) & Reproducibility (R) | Compliant with GB/T 17040–2019, GB 17411, and ASTM D4294 |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤95% at 35 °C |
| Power Supply | 11.1 V / 20.8 Ah Li-ion battery (≥5 h continuous operation) |
| Dimensions | 242 mm (W) × 258 mm (D) × 142 mm (H) |
| X-ray Tube | ≤10 kV, ≤1 mA, ≤10 W |
| Detector | Low-background ultra-thin Be-window proportional counter with secondary filtration |
| Pulse Processing | FPGA- and DSP-based digital multi-channel analyzer (MCA) with reduced dead time |
| Software | Embedded touchscreen OS with automatic C/H ratio correction, matrix effect compensation, and multi-range calibration curve switching |
| Regulatory Compliance | Meets radiation safety exemption criteria per CNPC and IAEA guidelines |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | C100 |
| Product Type | Online Instrument |
| Detection Target | Mechanical Contaminants |
| Particle Recognition Capability | ≥4 µm |
| Compliance Support | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic oil, lubricating oil, fuel, mineral oil, synthetic oil, coolant, cleaning solution, cutting fluid |
| AI Engine | Trained on >500 commercial lubricant models and ferrographic particle morphology database |
| Data Output | Wired (Ethernet gateway) or Wireless (Wi-Fi/LoRaWAN) |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | C120 |
| Type | Online Instrument |
| Detection Target | Mechanical Contaminants (Wear Debris) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ISO 4406, NAS 1638 |
| Fluid Compatibility | Hydraulic Oil, Lubricating Oil, Fuel Oil, Mineral & Synthetic Oils, Coolants, Cutting Fluids, Cleaning Solutions |
| Data Transmission | Wired Ethernet Gateway / Wireless (Wi-Fi/LoRaWAN) |
| AI Engine | Trained on >500 Commercial Lubricant Models & Lab-Validated Ferrographic Image Database |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EX S100 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants |
| Compliance | ATEX/IECEx Certified for Hazardous Areas |
| Particle Detection Threshold | ≥4 µm |
| Output Standards | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic Oils, Lubricating Oils, Mineral & Synthetic Oils, Fuels, Coolants, Cutting Fluids, Aqueous Solutions |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EXC100 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants |
| Compliance | ATEX/IECEx Certified for Hazardous Areas |
| Particle Detection Threshold | ≥4 µm |
| Output Standards | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic oil, lubricating oil, fuel, mineral & synthetic oils, coolants, cleaning fluids, cutting fluids |
| Data Interface | Wired Ethernet Gateway / Wireless (Wi-Fi/LoRaWAN) |
| AI Engine | Trained on >500 commercial lubricant models and ironographic particle morphology database |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EXS120 |
| Product Type | Online Instrument |
| Detection Target | Mechanical Contaminants (Particulate Wear Debris) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ATEX/IECEx Zone 1/21 Certified |
| Measurement Principle | AI-Enhanced Digital Image Analysis of In-Stream Oil Flow |
| Data Output | ISO 4406, NAS 1638, Wear Mode Classification (Fatigue, Cutting, Pitting, etc.) |
| Fluid Compatibility | Mineral Oils, Synthetic Lubricants, Hydraulic Fluids, Fuels, Coolants, Cleaning Solutions, and Aqueous Cutting Fluids |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OiHealth PROBE |
| Product Type | Online Instrument |
| Voltage | 24 V DC |
| Current Consumption | <200 mA |
| Digital Outputs | RS485 (Modbus RTU), Ethernet RJ45 (Modbus TCP/IP, FTP, Telnet) |
| Maximum Operating Pressure | 5 bar |
| Viscosity Range | 0–460 cSt |
| Operating Temperature | −20 °C to +80 °C |
| Ingress Protection | IP65 |
| Hydraulic Connection | 1/2″ BSP |
| Certifications | CE, GL Class pending |
| Detection Principle | Optical Absorption & Scattering Spectroscopy |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilCMS |
| Product Type | Portable Instrument |
| Detection Parameters | Tribological Wear Analysis |
| Oil Compatibility | Synthetic, Mineral, Organic Oils & Diesel (up to 3000 cSt) |
| Standards Compliance | ISO 4406, SAE AS4059, NAS 1638 |
| Software | Rubolab Oil Condition Monitoring Suite |
| Operating Modes | Offline (Bottle Sampling) & Online (High-Pressure Flow Cell) |
| Data Export | CSV, PDF |
| Calibration | Auto-calibration via embedded oil database (500+ lubricants), field-updatable |