Microbiology Detection Instruments
Filter
Showing 1–30 of 225 results
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MLSII |
| Pricing | Available Upon Request |
| Brand | ABER |
|---|---|
| Origin | United Kingdom |
| Model | OPTURA |
| Detection Method | Near-Infrared (NIR) Reflectance |
| Measurement Parameter | Total Biomass (Cell Density) |
| Temperature Range | 0–50 °C |
| Sampling Frequency | 2300 Hz |
| Operating Principle | Optical Reflectance at Fixed Wavelength (1310–1330 nm) |
| Compliance | USP Class VI & FDA 21 CFR Part 11 Ready (with optional certified probes and audit-trail software) |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Antares |
| Instrument Type | Automated Microcalorimetric Microbial Activity Monitoring System |
| Throughput | 19 samples |
| Sample Vessel | Ø40 × H86 mm ampoule |
| Temperature Range | 5–50 °C (water-circulating thermostat control) |
| Data Acquisition Interval | 60 s (continuous operation up to 166 days) |
| Dimensions | W465 × D650 × H500 mm |
| Weight | ~100 kg |
| Power Supply | AC 100 V, 10 A |
| Installation Requirement | Temperature-stabilized laboratory environment |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | LogPhase 600 |
| Instrument Type | Automated Microbial Growth Monitoring System |
| Throughput | Up to four 96-well microplates simultaneously |
| Optical Density Measurement | OD600 (600 nm) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Imported |
| Model | MobiLab2 |
| Price | Upon Request |
| Dimensions | 560 × 220 × 350 mm (W × H × D) |
| Weight | 25 kg |
| Power Supply | AC adapter or integrated high-capacity rechargeable battery |
| Sample Throughput | 9 samples or 9 assays simultaneously |
| Thermal Block Temperature Range | 4 °C – 105 °C |
| PCR Module Temperature Uniformity | ±0.3 °C |
| PCR Module Temperature Accuracy | ±0.2 °C |
| Heating/Cooling Module | High-efficiency, long-life Peltier elements |
| Incubation & Shaking | 25–100 °C, up to 1400 rpm |
| Detection Method | RAH (Rapid Amplification and Hybridization) coupled with lateral flow immunoassay (LFIA) |
| Readout Format | Visual interpretation of dual-line lateral flow strips (control + test bands) in sealed reaction chambers |
| Brand | AOE |
|---|---|
| Model | OD600 |
| Instrument Type | Benchtop Microbial Turbidimeter |
| Detection Wavelength | 600 nm ± 1 nm |
| Bandwidth | 10 nm |
| Absorbance Range | −0.3 to 3.0 Abs |
| Absorbance Accuracy | ±0.005 Abs (0–0.5 Abs), ±0.01 Abs (0.5–1.0 Abs) |
| Absorbance Repeatability | ≤0.002 Abs |
| Light Source | High-Stability Solid-State LED (20,000 h lifetime) |
| Detector | Silicon Photodiode |
| Sample Volume | 200–3000 µL |
| Display | 8-inch HD Color TFT LCD (1024 × 600) |
| Data Storage | 128 MB internal memory |
| Data Export | USB flash drive & microSD card support |
| Built-in Thermal Printer | Yes (auto/batch print) |
| Power Supply | AC 100–240 V, 50/60 Hz or DC 12 V / 3 A |
| Dimensions (W × D × H) | 290 × 260 × 100 mm |
| Weight | 2.15 kg |
| Brand | Autobio |
|---|---|
| Model | Autof MS |
| Origin | Henan, China |
| Laser Lifetime | >100 million shots |
| Mass Analyzer | Titanium Alloy Linear TOF (1.05 m) |
| Vacuum System | High-Throughput Turbo-Molecular Pump |
| Identification Speed | ≤0.1 s per sample (database search) |
| Microbial Database | 5,000+ species across 1,000+ genera, including filamentous fungi, anaerobic gut bacteria, and marine isolates |
| Nucleic Acid Detection Capacity | Up to 40-plex per well |
| Regulatory Certification | NMPA-approved calibration and control materials |
| Software Compliance | Audit trail, user access control, and electronic signature support per FDA 21 CFR Part 11 requirements |
| Brand | Autobio |
|---|---|
| Model | Autof ms2000 |
| Origin | Henan, China |
| Laser Source | Solid-state, ≥10⁹ shots lifetime, 1–1000 Hz tunable frequency |
| Ion Source Vacuum | ≤10⁻⁷ mbar |
| Ion Source Maintenance | Auto-cleaning cycle ≤10 min |
| Mass Analyzer | Titanium alloy flight tube with high thermal stability |
| Vacuum System | High-throughput turbomolecular pump |
| Signal Acquisition | High-precision FPGA-controlled real-time digitizer |
| Software Platform | AI-accelerated microbial identification engine (96 samples in <5 min) |
| Database Coverage | >1,000 genera, >5,000 species, >16,000 strains |
| Regulatory Status | CE-IVD compliant |
| Data Security | On-premise and cloud-deployable database options |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | Autostreak S1800 |
| Price Range | USD 140,000 – 210,000 (FOB) |
| Instrument Type | Fully Automated |
| Sample Type | Liquid (including sputum, broth cultures, urine supernatants) |
| Throughput | 180 Petri Dishes per Hour |
| Liquefaction Time | ≤5 min (sputum) |
| Streaking Time | ≤60 sec per 3 plates |
| Biosafety Level | Integrated Class II Biological Safety Cabinet Architecture |
| Filtration | HEPA H14 (99.995% @ 0.3 µm) |
| Decontamination | Automated UV-C (254 nm) cycle with timer-based scheduling |
| Consumables | Disposable sterile tips and single-use inoculation brushes |
| LIS Integration | ASTM E1384 / HL7 v2.x compliant interface |
| Software Compliance | Audit trail, user access control, electronic signature support per FDA 21 CFR Part 11 requirements |
| Brand | D.C. Labware |
|---|---|
| Origin | Guangdong, China |
| Model | Autopet-CP1 |
| Instrument Type | Single-needle colony picking workstation |
| Compatible Microorganisms | *Escherichia coli*, yeast, pathogenic bacteria, anaerobes, phage plaques, microalgae |
| Inoculation Mode | Solid-to-liquid transfer |
| Picking Throughput | 200–300 colonies/hour |
| Picking Accuracy | >99.5% |
| Positional Precision | ≤0.2 mm |
| Target Plate Compatibility | 24-, 48-, 96-, and 384-well plates |
| Source Plate Compatibility | Petri dishes with diameters of 6–9 cm |
| Dimensions (L×W×H) | 85 × 62 × 72 cm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BACTcontrol |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Fully Automated Microbial Enumeration System |
| Counting Speed | <15 min per assay (typical cycle time: 60–240 min) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BD |
| Temperature Range | Ambient + 5 °C to 100 °C |
| Internal Volume | 20 L (BD 23), 400 L (BD 400), 720 L (BD 720) |
| Internal Dimensions (W × H × D) | 222 × 330 × 277 mm (BD 23), 1000 × 800 × 500 mm (BD 400), 1000 × 1200 × 600 mm (BD 720) |
| External Dimensions (W × H × D) | 435 × 495 × 520 mm (BD 23), 1235 × 1025 × 765 mm (BD 400), 1235 × 1530 × 865 mm (BD 720) |
| Net Weight | 27 kg (BD 23), 135 kg (BD 400), 191 kg (BD 720) |
| Heating Technology | APT.line™ pre-heating chamber |
| Air Circulation | Free convection |
| Safety Features | Dual independent temperature safety device (DIN 12880 Class 3.1), optical temperature alarm, ESG safety glass inner door |
| Interface | RS 422 |
| Compliance | DIN 12880, EN 61000-6-3, EN 61000-6-2 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB |
| Temperature Range (KB 23) | 0 °C to 100 °C |
| Temperature Range (KB 53/115/240/400/720) | –5 °C to 100 °C |
| Cooling System | Compressor-based |
| Preheating Chamber Technology | APT.line™ |
| Inner Door Material | Safety Glass (ESG) |
| Interior Construction | Stainless Steel |
| Shelving | 2 Adjustable Stainless Steel Shelves |
| Stackable Units | Up to 115 L Models |
| Access Ports | Silicone-sealed, Available from 240 L |
| Temperature Safety Class | DIN 12880 Class 3.1 (Optical & Acoustic Alarm) |
| Controller | Programmable with Interval & Real-Time Scheduling |
| Runtime Timer | Integrated |
| Fan Speed Control | Adjustable from 240 L Onward |
| Interface | RS 422 |
| Internal Volume | 20–698 L (Model-Dependent) |
| External Dimensions (KB 23) | 435 × 620 × 520 mm |
| Internal Dimensions (KB 23) | 222 × 330 × 277 mm |
| Net Weight (KB 23) | 44 kg |
| Brand | TMAXTREE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automatic |
| Detection Method | Enzyme-Linked Electrode Sensor Array |
| Measurable Analytes | Glucose, Lactose, Galactose, Glutamic Acid, Glutamine, Lysine, Xylose, Glycerol, Lactic Acid, Ethanol, Methanol |
| Accuracy | <3% Full Scale |
| Sample Throughput | 50 samples/hour |
| Dimensions | 550 × 502 × 760 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | HMBX |
| Price | USD 11,800 (FOB) |
| Brand | Bioyong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Clin-TOF II |
| Target Price Range | USD 280,000 – 700,000 |
| Sample Throughput | Up to 384 samples per run |
| Detection Mode | Positive and Negative Ion Modes |
| Laser Repetition Rate | 60 Hz |
| Acquisition Time | ≤20 seconds per spot |
| Mass Resolution | High-resolution TOF analyzer with delayed extraction |
| Calibration | On-board auto-calibration using internal standards |
| Target Plate | Hydrophobically treated 384-well stainless steel MALDI target |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BZG30 |
| Pricing | Upon Request |
| Brand | Cerillo |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Alto (Stratus Upgrade Edition) |
| Detection Method | Absorbance |
| Detection Mode | Optical Density (OD) |
| Measurable Range | 0.000–4.000 OD |
| Temperature Range | 0–50 °C |
| Wavelengths | 600 nm, 450 nm, and customizable monochromatic LED sources |
| Resolution | 0.001 OD |
| Accuracy | < ±1% or ±0.02 OD (0–2.500 OD, endpoint mode) |
| Repeatability | < ±0.25% or ±0.005 OD (0–2.500 OD, endpoint mode) |
| Plate Compatibility | 6-, 12-, and 96-well standard microplates |
| Dimensions (Analyzer) | 15.0 × 13.3 × 7.2 cm |
| Weight (Analyzer) | 800 g |
| Power Input | 5 V, 500 mA via USB-C |
| Operating Environment | 0–50 °C, 0–99% RH |
| Software OS Support | macOS 11/12, Windows 10/11 |
| Data Storage | 16 GB internal (expandable to 32 GB), CSV export |
| Wireless Capability | Optional Bluetooth/Wi-Fi module, up to 5 units daisy-chained, max range 15 m |
| Compliance | RoHS, REACH, FCC, CE |
| Intended Use | Research Use Only (RUO), not for diagnostic or clinical applications |
| Brand | Other brands |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | General distributor |
| Product Origin | Domestic (China) |
| Model | Cerillo |
| Price | Upon request |
| Measurement Mode | Endpoint and kinetic absorbance |
| Plate Compatibility | 6-, 12-, and 96-well plates |
| Dimensions | 15.0 × 13.3 × 7.2 cm (W × D × H) |
| Weight | 800 g |
| Power Supply | 5 V, 500 mA via USB-C |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–99% RH |
| Wavelengths | 450 nm and 600 nm (monochromatic LEDs) |
| Optical Density (OD) Resolution | 0.001 OD |
| OD Range | 0.000–4.000 OD |
| Linearity | < ±1% (0.000–2.500 OD) |
| Accuracy (Endpoint) | < ±1% and ±0.02 OD (0.000–2.500 OD) |
| Accuracy (Kinetic) | < ±0.25% and ±0.005 OD (0.000–2.500 OD) |
| Repeatability | < ±0.25% and ±0.005 OD (0.000–2.500 OD) |
| Membrane Material | Polycarbonate |
| Surface Treatment | PVP (polyvinylpyrrolidone) hydrophilic coating |
| Pore Size | 0.2 µm |
| Effective Membrane Area | 0.503 cm² |
| Membrane Diameter | 0.8 cm |
| Membrane Thickness | 25 µm |
| Data Storage | microSD card (up to 32 GB |
| OS Compatibility | macOS 11 (Big Sur) or later |
| Data Export Formats | .csv (on-device), .xlsx (via Labrador software) |
| Regulatory Compliance | RoHS, REACH, FCC, CE |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Charm EPIC Plus |
| Instrument Type | Fully Automated Microbial Contamination Screening System |
| Throughput | 96 samples per run |
| Detection Principle | ATP Bioluminescence Quantification |
| Incubation Time | 36–48 h (intact-package incubation) |
| Software | EPICLink v5.x with Audit Trail & Data Export |
| Compliance | Designed for GLP/GMP environments |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Charm Peel Plate Colony Counter |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Semi-Automatic Microbial Enumeration System |
| Detection Throughput | Up to 96 Peel Plate™ assays per hour (based on standard workflow) |
| Compatible Assay Formats | Total Aerobic Count, *E. coli*, Coliforms, Yeast & Mold, Enterobacteriaceae |
| Integrated Camera Resolution | ≥5 MP |
| Display | 6.75-inch diagonal touchscreen LCD |
| Dimensions (W × H × D) | 32.0 × 22.86 × 16.764 cm |
| Weight | 4.54 kg (10 lbs) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Onboard Storage Capacity | 66,000 assay records |
| Data Export Formats | JPEG (raw & processed images), CSV (quantitative results), SQL-compatible database output via Ethernet |
| Input Devices | Wireless keyboard/mouse, optional barcode scanner |
| Calibration Check | Configurable frequency — at startup, after user-defined count intervals, or on-demand |
| User Roles | Dual-tier (Operator + Administrator) with role-based access control (RBAC) |
| Compliance | Designed for GLP-compliant environments |
| Brand | Chu Ding |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HCC-02 |
| Instrument Type | Semi-Automatic Colony Counter |
| Counting Speed | 150 colonies/min |
| Optical Magnification | 3× and 6× |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HAS-100C |
| Instrument Type | Manual Slit-Impact Air Sampler |
| Sampling Flow Rate | 100 L/min (typical) |
| Collection Efficiency | ≥95% for particles ≥0.6 µm (per Anderson principle calibration) |
| Display | Dot-matrix LCD with real-time battery indicator |
| Power | Rechargeable Ni-MH battery (≥8 h continuous operation) |
| Sample Rotation Speed | Adjustable (0–3 rpm) |
| Auto-Power Management | Backlight off after 30 s inactivity |
| Sterilization Compatibility | Removable sampling head withstands autoclaving at 121°C for 20 min |
| Dimensions | 240 × 180 × 220 mm |
| Weight | 3.2 kg |
| Compliance | Designed per GB/T 18883–2002 and aligned with ISO 14698-1:2003 principles for biocontamination control |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | CHW-300BS |
| Instrument Type | Semi-Automatic Microbial Limit Testing System |
| Throughput | 3 independent filtration channels |
| Filter Membrane Diameter | Φ47 mm / Φ50 mm |
| Effective Filtration Area | 40 mm diameter |
| Filter Cup Capacity | 150 mL (250 mL optional) |
| Filtration Rate | 100 mL per 15 s |
| Vacuum Source | Built-in进口 diaphragm liquid-handling pump (oil-free) |
| Sterilization Methods | Autoclavable filtration heads |
| Display | LCD interface showing real-time time/date and pump status |
| Compliance | Designed for USP <61>, <62>, EP 2.6.12, and ISO 8573-7 compliant microbial enumeration workflows |
| Brand | Bioyong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Clin-TOF-I |
| Price Range | USD 140,000 – 280,000 |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automated Colony Counter |
| Sample Format | Petri Dish (90–110 mm diameter) |
| Counting Accuracy | ≤ ±10% |
| Imaging Resolution | 1920 × 1080 pixels |
| Key Software Functions | Threshold Adjustment, ROI Selection (Circle/Rectangle/Freehand), Automatic Calibration, Dual Illumination Control, PDF Report Export, Multi-User GLP-Compliant Data Management |
| Brand | COMECAUSE |
|---|---|
| Model | IN-J100 |
| Imaging Sensor | 8 MP color CMOS camera |
| Minimum Detectable Colony Size | 0.5 mm |
| Counting Accuracy | ±10% |
| Integrated Display | 15.6″ Full HD (1920×1080) touchscreen |
| OS | Windows 10 Pro 64-bit |
| Storage | 256 GB SSD |
| Calibration | Factory-preconfigured auto-calibration based on optical parameters (lens focal length, working distance, sensor resolution) |
| Data Export | PDF reports with immutable raw image archive |
| User Management | Multi-user login with isolated data partitions |
| Language Support | Switchable English/Chinese UI |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automated Colony Counter |
| Sample Format | Petri Dish |
| Compatible Dish Diameter | 90–110 mm |
| Counting Accuracy | ≤ ±10% |
| Imaging Resolution | 1920 × 1080 (16 MP Color CMOS Sensor) |
| Key Features | Fluorescence Excitation (366 nm), UV Sterilization (254 nm), Dual-Independent Adjustable Illumination (Top/Bottom), Touchscreen Interface (15.6″, Full HD), Onboard Windows 10 OS (64-bit, 256 GB SSD), Multi-Mode Segmentation Algorithms, Real-Time Threshold Adjustment, ROI Annotation Tools, Size-Based Classification (25 Bins), PDF Export with Immutable Raw Data Archive, Dual-Language UI (EN/CN), Multi-User Account System with Audit-Trail Capable Data Isolation |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automated Colony Counter |
| Sample Type | Standard Petri Dishes (90–110 mm diameter), 3M Petrifilm™, Compact Dry™, RIDA™ Filter Membranes, Fluorescent & Non-fluorescent Microbial Colonies |
| Imaging System | Sealed Light-Tight Dark Chamber with Stray-Light Elimination |
| Illumination | Dual-Independent Adjustable Top/Bottom LED Light Sources |
| UV Modules | 254 nm (sterilization & mutagenesis), 366 nm (fluorescence excitation for *E. coli*, GFP, etc.) |
| Camera | 16 MP Full-Color CMOS Sensor |
| Minimum Detectable Colony Size | 0.1 mm |
| Counting Accuracy | ≤ ±10% |
| Display | 15.6″ Touchscreen (1920 × 1080), Windows 10 64-bit OS, 256 GB Internal Storage |
| Software | Integrated Colony Recognition Engine with Multi-Mode Segmentation Algorithms |
| Compliance | Supports GLP-compliant audit trails, user-level access control, immutable PDF reporting, bilingual (EN/CN) UI |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | IN-J300 |
| Instrument Type | Fully Automated Colony Counter |
| Sample Type | Petri Dish |
| Sample Diameter Range | 90–110 mm |
| Counting Accuracy | ≤ ±10% |
| Imaging Resolution | 1920 × 1080 pixels |
| Correction Function | Manual & AI-assisted Refinement |
