| Brand | HISTO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Histo-150-X |
| Capacity | 300 standard tissue cassettes |
| Wax Tanks | 4 (3 × 4.3 L + 1 × 5.5 L) |
| Waste Wax Tank | 1 |
| Reagent Bottles | 13 (10 dehydration + 3 cleaning) |
| Temperature Control | 12 independent channels, ±1°C accuracy, max 70°C |
| Pressure Range | ±70 kPa |
| Dehydration Modes | 4 (Atmospheric, P, V, PV) |
| Heating Material | Monolithic aluminum alloy tank with Teflon coating, thermal conductivity >150 W/m·K |
| Agitation | Side-mounted mechanical stirrer |
| Level Sensing | Triple ultrasonic sensors |
| Fluid Path | Top-in / bottom-out design with gas–liquid isolation bottles |
| Exhaust | Activated carbon filtration + external vent interface |
| Display | 12″ color touchscreen, Windows 7 OS |
| Power | AC 100–240 V, 50–60 Hz, 2 kW |
| Dimensions (L×W×H) | 67 × 65 × 130 cm |
| Weight | 150 kg |
| Compliance | CE-marked architecture compatible with GLP/GMP documentation workflows |
| Brand | Leica |
|---|---|
| Origin | USA |
| Model | HistoCore PEGASUS & HistoCore PEGASUS Plus Dual-Chamber Tissue Dehydrator |
| Capacity | Up to 400 specimens per run |
| Chamber Configuration | Two independent, thermally isolated processing chambers |
| Reagent Management | Color-coded, RFID-enabled reagent bottles with volume tracking |
| Compliance | Designed for GLP/GMP-aligned histopathology laboratories |
| Software | Leica Application Suite (LAS) v5.x with audit trail and user access control |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | HistoCore PEGASUS |
| Type | Fully Automated Parallel-Processing Tissue Dehydrator |
| Regulatory Compliance | CE-marked, IVD-compliant (Class B), Designed for ISO 13485 and GLP environments |
| Reagent Management | Integrated color-coded reagent bottle recognition system with level monitoring |
| User Access Control | Three-tier authentication (Operator, Supervisor, Administrator) |
| Data Integrity | Audit-trail enabled, FDA 21 CFR Part 11–ready software logging |
| Display | Backlit LCD with real-time reagent level visualization and connection status feedback |
| Stirring Technology | Electromagnetic stirring for uniform reagent exchange and optimized paraffin infiltration |
| Throughput | Dual independent processing chambers supporting concurrent protocols |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | YXQ-LS-100A |
| Capacity | 100 L |
| Max Operating Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Power Rating | 4 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| External Dimensions (W×D×H) | 600 × 500 × 1260 mm |
| Chamber Diameter × Height | Ø400 × 760 mm |
| Basket Dimensions (Ø × H × Qty) | Ø360 × 240 mm × 3 units |
| Control Modes | Standard exhaust / Pulse exhaust / No exhaust |
| Brand | Shen'an / She Medical Devices |
|---|---|
| Origin | Shanghai, China |
| Model | LDZM-40KCS (Intelligent Type) |
| Chamber Volume | 40 L |
| Chamber Dimensions | Φ355 × 400 mm |
| Power Supply | 220 V AC |
| Heating Power | 3 kW |
| Net Weight | 55 kg |
| External Dimensions | 620 × 520 × 750 mm |
| Sterilization Temperature Range | 50–134 °C |
| Time Setting Range | 0–99 h |
| Safety Features | Interlocked door mechanism, low-water protection, automatic exhaust control, audible end-of-cycle alarm |
| Optional Accessories | Thermal printer module, post-sterilization drying unit |
| Compliance | Designed to meet GB 8599–2008 (Chinese national standard for steam sterilizers), compatible with ISO 17665-1:2017 principles for moist heat sterilization validation |
| Brand | Shen'an / She Medical Devices |
|---|---|
| Origin | Shanghai, China |
| Model | LDZM-80KCS (Intelligent Type) |
| Chamber Volume | 80 L |
| Power Supply | 220 V AC |
| Heating Power | 3 kW |
| Net Weight | 65 kg |
| External Dimensions | 620 × 520 × 1250 mm |
| Chamber Dimensions | Φ355 × 800 mm |
| Sterilization Temperature Range | 50–134 °C |
| Time Setting Range | 0–99 h |
| Safety Features | Interlocked door mechanism, low-water cutoff protection, internal exhaust system, audible end-of-cycle alarm, automatic shutdown |
| Optional Accessories | Thermal printer module, vacuum drying unit |
| Construction | 304 stainless steel chamber and exterior housing |
| Door Mechanism | Rotating quick-release lid |
| User Interface | Digital LCD display with Chinese-language menu and one-touch parameter entry |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | United Kingdom |
| Model | STP 120 |
| Reagent Stations | 10 (9 when 3 paraffin stations configured) |
| Paraffin Stations | 2 (optional 3rd) |
| Station Volume | 1.8 L each |
| Voltage | 100–120 V / 220–240 V AC (±10%), 50–60 Hz |
| Temperature Range | 50–70 °C |
| Overtemperature Cutoff | 75 °C (±4 °C) |
| Cassette Basket Capacity | 120 cassettes (1 basket standard, optional 2nd) |
| Programmable Protocols | 10 stored methods |
| Dwell Time per Station | 1 sec – 99 hr 59 min |
| Rotation-Based Agitation | Enabled |
| Vertical Agitation | Optional |
| Centrifugal Drying | Optional |
| Delayed Start | Supported |
| Safety | Overheat protection with automatic power cutoff and integrated backup power circuit |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YXQ-LS-100G |
| Capacity | 100 L |
| Max. Operating Temperature | 135 °C |
| Max. Operating Pressure | 0.22 MPa |
| Sterilization Power | 3.5 kW |
| Drying Power | 0.8 kW |
| Voltage/Frequency | 220 V ±10% / 50 Hz ±2% |
| External Dimensions (mm) | 600 × 500 × 1280 |
| Chamber Dimensions (mm) | Ø400 × 725 |
| Basket Dimensions (mm) | Ø360 × 240 × 3 units |
| Temperature Range | 109–135 °C |
| Sterilization Time Range | 4–120 min |
| Drying Time Range | 30–240 min |
| Safety Compliance | Meets PRC Pressure Vessel Safety Technical Supervision Regulations (Article 49) |
| Brand | YaCheng / PILOTECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YC-02 |
| Rated Capacity | 20–25 L/h (adjustable flow: 5–50 L/h) |
| Minimum Sample Volume | 3–5 L |
| Sterilization Temperature Range | Up to 150 °C |
| Temperature Control Accuracy | ±1 °C (PID-controlled) |
| Sterilization Hold Time | 5–300 s (standard: 5 s, 10 s |
| optional | 30 s, 300 s) |
| System Pressure | 5 bar |
| CIP Flow Rate | 400 L/h |
| Product Transfer Flow Rate | 5–25 L/h |
| Heating Method | Integrated electric overheated water generator with dual high-temp circulating pumps |
| Cooling | Dual-tube preheating sections + single-tube cooling section (tap-water cooled to near ambient) |
| Construction Material | Full 316L stainless steel |
| Compliance Features | Built-in SIP capability, online CIP, back-pressure control valves (imported diaphragm type), tri-way diverting valve, pressure sensors with real-time HMI display |
| Control System | PLC-based, color TFT touchscreen interface with animated process visualization, USB data export (Excel-compatible), print-ready output |
| Optional Add-ons | Homogenizer integration, sterile filling chamber (10 L jacketed buffer tank with single-head aseptic filler) |
| Brand | Yacheng / PILOTECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | YC-02 |
| Quotation | Upon Request |
| Rated Capacity | 20–25 L/h (adjustable flow: 5–50 L/h) |
| Minimum Sample Volume | 3–5 L |
| Sterilization Temperature Range | Up to 150 °C |
| Temperature Control Accuracy | ±1 °C (PID-controlled) |
| Sterilization Holding Time | Standard 5 s or 10 s (optional: 30 s, 300 s) |
| System Pressure | 5 bar |
| CIP Flow Rate | 400 L/h |
| Product Transfer Flow Rate | 5–25 L/h |
| Cooling Outlet Temperature | Adjustable down to 5 °C |
| Power Rating | 13 kW |
| Construction Material | Full 316L Stainless Steel |
| Pump Type | German-made NETZSCH (formerly SEEPEX) Sanitary Screw Pump |
| Preheating Sections | 2 tubular |
| Cooling Section | 1 tubular |
| Hot Water Generator | Integrated |
| Circulating Hot Water Pumps | 2 units |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YXQ-LS-50G |
| Chamber Volume | 50 L |
| Max Operating Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Sterilization Power | 3.1 kW |
| Drying Power | 0.8 kW |
| Voltage/Frequency | 220 V ±10% / 50 Hz ±2% |
| External Dimensions (W×D×H) | 600 × 500 × 1080 mm |
| Internal Chamber Diameter × Height | Ø350 × 525 mm |
| Basket Dimensions | Ø330 × 250 mm (2 pcs) |
| Sterilization Time Range | 4–120 min |
| Drying Time Range | 30–240 min |
| Temperature Range | 109–135 °C |
| Safety Compliance | Meets PRC Pressure Vessel Safety Technical Supervision Regulations (Article 49) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YXQ-LS-70A |
| Chamber Volume | 75 L |
| Max Operating Temperature | 135 °C |
| Max Operating Pressure | 0.22 MPa |
| Power Rating | 3.5 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| External Dimensions (W×D×H) | 600 × 500 × 1130 mm |
| Internal Chamber Diameter × Height | Ø400 × 570 mm |
| Basket Dimensions (Ø × H × Qty) | Ø360 × 280 mm × 2 units |
| Sterilization Cycle Modes | Standard Exhaust / Pulse Exhaust / No-Exhaust |
| Control System | Microprocessor-based Intelligent Controller |
| Safety Compliance | Meets PRC Pressure Vessel Safety Technical Supervision Regulations (Article 49) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YXQ-LS-75G |
| Chamber Volume | 75 L |
| Maximum Operating Temperature | 135 °C |
| Maximum Operating Pressure | 0.22 MPa |
| Sterilization Power | 3.2 kW |
| Drying Power | 0.8 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| External Dimensions (W×D×H) | 600 × 500 × 1150 mm |
| Internal Chamber Diameter × Height | Ø350 × 625 mm |
| Basket Dimensions (Ø × H × Qty) | Ø360 × 280 mm × 2 units |
| Sterilization Time Range | 4–120 min |
| Drying Time Range | 30–240 min |
| Temperature Range | 109–135 °C |
| Safety Compliance | Meets PVR Safety Technical Supervision Regulations Art. 49 (China) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YXQ-SG46-280SA |
| Chamber Volume | 18 L |
| Rated Operating Temperature | 126 °C |
| Rated Working Pressure | 0.142 MPa |
| Power Rating | 2 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Dimensions (D×H) | 390 mm × 470 mm |
| Construction Material | SUS304 Stainless Steel (Outer Shell & Inner Chamber) |
| Safety Features | Pressure-Actuated Self-Relief Valve, Dual-Scale Pressure Gauge, Auto-Locking Lid Mechanism, Expansion-Type Sealing Ring |
| Heating Mode | Dual-Fuel (Electric or Solid Fuel Compatible) |
| Lid Operation | Lever-Actuated Quick-Opening Mechanism |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ATP300 |
| Price Range | USD 7,000 – 14,000 |
| Reagent Bottle Capacity | 2.3 L / 3.2 L (selectable) |
| Tissue Processing Chamber Volume | 3.8 L / 5.3 L (selectable) |
| Reagent Temperature Range | 30–70 °C |
| Paraffin Bath Temperature | Ambient to 80 °C ±1 °C |
| Immersion Time Setting | 0–99 h 59 min |
| Agitation Duration | 1 min |
| Agitation Interval | 10 min |
| Operating Modes | Manual & Automatic |
| Input Power | 1500 W |
| Voltage/Frequency | 220 V, 50 Hz |
| Maximum Specimen Capacity | 100 / 200 / 300 cassettes (configurable) |
| Display | Color LCD with English UI |
| User Programs | 8 pre-programmable protocols |
| Safety Features | Overtemperature protection, power-failure recovery, full liquid evacuation control, triple-stage reagent exhaust system |
| Construction | Stainless steel processing chamber and fluid pathways |
| Brand | ZEEDO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HS-1000 |
| Price | USD 5,500 (FOB) |
| Number of Reagent Stations | 12 (9 reagent jars + 3 paraffin wax baths) |
| Processing Time per Station | Stations 1–9: 0–99 hrs adjustable |
| Stations 10–12 | 0–24 hrs adjustable |
| Wax Bath Temperature Range | Ambient to 99 °C, digitally controlled |
| Heating Method | Dry-type internal heating |
| Single Jar Capacity | 1000 mL |
| Temperature Control Accuracy | ±2 °C |
| Agitation Frequency | 2 cycles/min |
| Power Failure Protection | >6 hrs autonomous operation without external battery backup |
| Operating Ambient Temperature | 0–40 °C |
| Input Voltage | 220 VAC, 50 Hz |
| Rated Power | 800 W |
| Dimensions (W×D×H) | 1000 × 420 × 450 mm |
| Net Weight | 80 kg |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS-1000 |
| Price Range | USD 1,400–7,200 |
| Number of Reagent Stations | 12 (9 reagent tanks + 3 paraffin wax tanks) |
| Processing Time per Station | Tanks 1–9: 0–99 hours programmable |
| Tanks 10–12 | 0–24 hours programmable |
| Paraffin Temperature Range | Ambient to 99 °C adjustable |
| Heating Method | Dry-type internal heating |
| Single Tank Capacity | 1000 mL |
| Temperature Control Accuracy | ±2 °C |
| Agitation Frequency | 2 cycles/min |
| Power Failure Protection | >6 hours continuous operation without external battery backup |
| Operating Ambient Temperature | 0–40 °C |
| Input Voltage | 220 VAC, 50 Hz |
| Rated Power | 800 W |
| Dimensions (W×D×H) | 1000 × 420 × 450 mm |
| Net Weight | 80 kg |
| Brand | ZEEDO |
|---|---|
| Origin | Zhejiang, China |
| Model | HS-1500 |
| Chamber Count | 9 reagent + 3 paraffin wax chambers |
| Single Chamber Volume | 1500 mL |
| Reagent Chamber Timing | 0–99 h (Chamber 1), 0–24 h (Chambers 2–9) |
| Wax Chamber Timing | 0–24 h (Chambers 10–12) |
| Temperature Range | Ambient to 99 °C |
| Tissue Protection Chamber Selection | Configurable across Chambers 1–7 |
| Drain/Drain-and-Shake Dwell Time | 10–60 s |
| Post-Entry Heating Activation | Auto-start from Chamber 2 |
| Power Supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Power Consumption | 800 VA |
| Dimensions (W×D×H) | 1010 × 550 × 420 mm |
| Net Weight | 80 kg |
| Max. Throughput | ≥75 tissue specimens per cycle |
| Stirring Frequency | 0–6 rpm (adjustable) |
| Display | Large LCD with bilingual (English/Chinese) GUI and real-time animation |
| Safety | Sealed exhaust system with activated carbon filtration |
| Power Failure Recovery | >30 h backup operation with status retention and auto-resume capability |
| Cylinders | 9 reagent + 3 paraffin tanks (12 total) |
|---|---|
| Single tank capacity | 1500 mL |
| Processing time per station | 0–99 h (1st station), 0–24 h (others) |
| Temperature range | ambient to 99°C |
| Drain/hold time | 10–60 s |
| Stirring frequency | 0–6 rpm |
| Power supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Power consumption | 800 VA |
| Dimensions | 1010 × 550 × 420 mm |
| Weight | 80 kg |
| Throughput | ≥75 tissue specimens per cycle |
| Safety | Sealed chamber, internal air purification, external exhaust port, dry-type internal heating, power-failure retention (>30 h) |
| Brand | ZEEDO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HS-200 |
| Price | USD 17,500 (FOB Zhejiang) |
| Tissue Processing Capacity | 200 specimens per cycle |
| Processing Chamber Volume | 5 L |
| Reagent Bottles | 17 (9 liquid, 3 cleaning, 2 filtration, 3 paraffin wax) |
| Reagent/Wax Temperature Range | Ambient to 99 °C |
| Vacuum/Pressure Range | 0.15–0.20 MPa |
| Dehydration Time Setting | 0–99 h 59 min |
| Fluid Transfer Duration | 3–10 min (fill/empty) |
| Stirring Duration | 0–60 s |
| Power Consumption | ≤1800 W |
| Dimensions (L×W×H) | 660 × 600 × 1250 mm |
| Net Weight | 120 kg |
| Brand | ZEEDO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-2000 |
| Price | USD 9,200 (FOB) |
| Solvent Chambers | 9 |
| Paraffin Chambers | 3 |
| Chamber Capacity | 2,000 mL (SX) / 2,500 mL (SD) |
| Processing Time Range | 1 min – 99 h per step |
| Temperature Control Range | Ambient – 99 °C |
| Protective Chamber Position | #7 (for safeguard solution) |
| Maximum Continuous Operation Duration | 1 year (programmable) |
| Dwell Time per Chamber | 1 min – 99 h |
| Paraffin Bath Temperature | Ambient – 99 °C (direct-heating silicone film heater) |
| Dual Overheat Protection | Yes |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 600 W |
| Net Weight | 80 kg |
| Dimensions (W × D × H) | 1050 × 530 × 350 mm |
| Carbon Filtration System | Integrated activated carbon filter |
| Control System | Microprocessor-based with 8 programmable protocols |
| Positioning Accuracy | Optical sensor + stepper motor drive with rail-guided carriage |
| Auto-Home & Error Compensation | Yes |
| Chamber Drain Delay | 30 s dwell at lift-off to minimize cross-contamination and reagent dilution |
| Agitation Mode | Dynamic fluid exchange during immersion to enhance dehydration kinetics |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HS-2000 |
| Price Range | USD 1,400 – 7,200 |
| Cylinder Count | 12 (9 reagent tanks + 3 paraffin wax tanks) |
| Single Tank Capacity | 2000 mL |
| Per-Tank Processing Time | Tank 1: 0–99 h |
| Tanks 2–12 | 0–24 h |
| Temperature Control Range | Ambient to 99 °C |
| Adjustable Tissue Protection Tanks | Tanks 1–7 |
| Drain & Shake Dwell Time | 10–60 s (tank-surface drainage + mechanical shaking) |
| Heating Activation | Auto-start from Tank 2 |
| Power Supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Power Consumption | 800 VA |
| Dimensions (W×D×H) | 1010 × 550 × 420 mm |
| Net Weight | 100 kg |
| Max. Throughput | ≥200 tissue specimens per cycle |
| Agitation Frequency | 0–6 cycles/min |
| Drain Timing Control | Programmable per transfer step |
| Power Failure Resilience | >30 h retained runtime with status display |
| Internal Air Purification | Activated carbon filtration + optional external exhaust ducting |
| User Interface | Dual-language (English/Chinese) LCD with animated process simulation and real-time status feedback |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS-366 |
| Price Range | USD 7,000 – 14,000 |
| Tissue Processing Stages | 12 |
| Solvent Stations | 9 × 1.2 L |
| Paraffin Stations | 3 × 1.0 L |
| Temperature Control Range | 45–85 °C (±3 °C) |
| Per-Station Timer | 0–59 h 59 min |
| Delay Start | 0–59 h 59 min |
| Basket Agitation Frequency | 3 cycles/min |
| Basket Dimensions | Φ95 × 80 mm (single-tier) / Φ95 × 80 mm × 5 layers (stacked) |
| Net Weight | ~60 kg |
| External Dimensions | 660 × 550 × 680 mm |
| Rated Voltage | AC 220 V, 50 Hz |
| Power Consumption | 500 W |
| Operating Environment | +5 to 40 °C ambient |
| Display Language | Switchable Chinese/English LCD |
| Stored Protocols | 10 user-programmable methods |
| Minimum Time Increment | 1 minute |
| Maximum Delay Duration | 30 days |
| Paraffin Bath Temperature Stability | High-precision PID control with TEFLON-coated interior surfaces |
| Safety Features | Power-failure alarm, cylinder-position retention logic, mechanical obstruction detection, optional UPS integration (4–16 h runtime) |
| Brand | ZEEDO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HS-366 |
| Price | USD 9,200 (FOB) |
| Tissue Processing Stages | 12 |
| Solvent Stations | 9 × 1.2 L glass cylinders |
| Paraffin Stations | 3 × 1.0 L heated wax baths |
| Temperature Control Range | 45–85 °C (±3 °C) |
| Stage Time Setting | 0–59 h 59 min per station |
| Delay Start | 0–59 h 59 min |
| Basket Agitation Frequency | 3 cycles/min |
| Basket Dimensions | Φ95 × 80 mm (single-tier) or 5-layer stackable |
| Net Weight | ~60 kg |
| External Dimensions | 660 × 550 × 680 mm |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 500 W |
| Operating Environment | +5 to +40 °C ambient temperature |
| Display Language | Switchable Chinese/English LCD interface |
| Pre-stored Protocols | 10 user-programmable methods |
| Minimum Time Resolution | 1 minute |
| Wax Bath Temperature Stability | ±0.5 °C under load |
| Interior Surface Coating | PTFE (Teflon®) anti-adhesive and corrosion-resistant finish |
| Safety Features | Power-failure alarm with auto-suspension to designated solvent station, mechanical obstruction detection, emergency stop, over-temperature cutoff |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | HS-566 |
| Price Range | USD 7,000 – 14,000 |
| Tissue Processing Stages | 12 |
| Solvent Stations | 9 × 1.2 L |
| Paraffin Stations | 3 × 1.0 L |
| Temperature Control Range | 45–85 °C (±3 °C) |
| Per-Station Timer | 0–999 min |
| Delay Start | 0–999 min |
| Vacuum Level | ≤0.053 MPa |
| Agitation Frequency | 3 cycles/min |
| Basket Dimensions | Φ95 × 80 mm (cylindrical & tiered) |
| Net Weight | ~60 kg |
| External Dimensions | 670 × 550 × 680 mm |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 500 W |
| Operating Environment | +5–40 °C, RH <85% (at 20±5 °C) |
| Brand | ZEEDO |
|---|---|
| Origin | Zhejiang, China |
| Model | HS-566 |
| Tissue Processing Stages | 12 |
| Reagent Stations | 9 (1.2 L each) |
| Paraffin Stations | 3 (1.0 L each) |
| Temperature Control Range | 45–85 °C (±3 °C) |
| Max. Timer per Station | 999 min |
| Delay Start Time | 999 min |
| Vacuum Level | ≤0.053 MPa |
| Basket Agitation Frequency | 3 cycles/min |
| Basket Dimensions | Φ95 × 80 mm (single-tier & multi-tier) |
| Net Weight | ~60 kg |
| External Dimensions | 670 × 550 × 680 mm |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 500 W |
| Operating Ambient | 5–40 °C, <85% RH (at 20 ± 5 °C) |
| Capacity | Up to 300 tissue cassettes per run |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LSS800 |
| Price Range | USD 7,000 – 14,000 |
| Drive System | High-precision servo motor with synchronous belt transmission |
| Control System | PLC + 7-inch TFT touch screen (English UI) |
| Positioning | Photoelectric sensor-based automatic basket positioning |
| Programmability | Up to 3 staining baskets concurrently |
| Staining Time Resolution | 1–9999 s (1-s increment) |
| Temperature Control | Adjustable from ambient to 85 °C per dye bath |
| Capacity | 30 glass slides per basket |
| Bath Configuration | 26 total stations — including 3 dedicated rinse tanks, 1 waiting tank, and independent water supply with pressure-regulated on-demand delivery |
| Dimensions | 1200 × 500 × 600 mm (W × D × H) |
| Weight | 80 kg |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power | 200 W |