| Brand | AOM |
|---|---|
| Origin | Germany |
| Model | SpraySpy LabLine |
| Input Impedance (Reference Electrode) | 23 MΩ |
| Sensitivity | 1 mV/pA |
| Potential Increment | 56 mV |
| Scan Rate | 1200 mV/s |
| IP Rating | IP67 |
| Measurement Principle | Laser-based single-droplet scattering time-of-flight (ToF) |
| Droplet Size Range | 5–500 µm (typical, application-dependent) |
| Velocity Range | 0.1–150 m/s |
| Data Output | Histograms, flux density, momentum, kinetic energy, opacity index, temporal event log |
| Software Platform | SprayAI™ with real-time classification (OK/NOK), audit trail, CSV/JSON export |
| Compliance | Designed for GLP/GMP-aligned R&D environments |
| Brand | ATS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Kerr Microscope |
| Price Range | USD 68,000 – 136,000 |
| Magnetic Field | Up to 1.2 T (perpendicular), up to 0.8 T (in-plane) |
| Optical Resolution | Sub-micron (dependent on objective lens) |
| Wavelength Range | 405–1550 nm (configurable) |
| Imaging Frame Rate | Up to 100 fps (full FOV), real-time video acquisition |
| Sample Stage | Motorized XYZ + tilt, vacuum-compatible option available |
| Environmental Control | Temperature-stabilized optical platform, RH < 60 % recommended |
| Power Supply | 220 V, 50 Hz |
| Brand | BioLight |
|---|---|
| Model | Lux-P110 |
| Detection Principle | Photon counting via cooled photomultiplier tube (PMT) |
| Dynamic Range | ≥ 7 decades (typical for high-end luminometers) |
| Sensitivity | ≤ 10 amol ATP (firefly luciferase assay, 96-well plate) |
| Read Modes | Flash & Glow luminescence |
| Plate Formats | 6–1536-well microplates |
| Temperature Control | Ambient to 45 °C (±0.5 °C uniformity) |
| Integrated Injector | Dual-channel, programmable, in-situ dispensing |
| Shaking | Tri-mode (linear, orbital, circular) with six speed settings (200–1200 rpm) |
| Detector | Thermoelectrically cooled PMT (−20 °C operating temperature) |
| Software | LuxWin v5.x with FDA 21 CFR Part 11-compliant audit trail, GLP/GMP reporting templates, and kinetic/endpoint/multiple-injection protocols |
| Compliance | ISO/IEC 17025-aligned validation support, ASTM E2578-21 referenced for luminometer performance verification |
| Data Export | CSV, XML, PDF, Excel-compatible formats |
| Brand | BioLight |
|---|---|
| Model | Lux-T020 |
| Origin | Guangdong, China |
| Detector Type | Electrochemiluminescence & Bioluminescence Luminometer |
| Photomultiplier Tube (PMT) | Single-Photon Counting PMT |
| Max Count Rate | >100 million pulses/sec |
| Detection Sensitivity | ≤10 amol ATP or 20 zmol firefly luciferase |
| Dynamic Range | 7 decades (linear) |
| Sample Format | 12 × 55 mm test tubes or standard 0.5–2.0 mL microcentrifuge tubes |
| Interface | Touchscreen GUI with USB data export |
| Compliance | Designed for GLP-compliant workflows |
| Brand | CEL (China Education Goldsource) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CEL-PCRD50-2 LED Photoreactor |
| Pricing | Upon Request |
| Sample Capacity | 2 × 50 mL (quartz reaction tubes) |
| Illumination Mode | Dual independent side-illumination |
| Illumination Area per Position | 100 mm × 20 mm (standard, for 50 mL) |
| LED Power | 2 × 25 W (DC 38 V, ±0.01%) |
| Total Input Power | 100 W (AC 220 V, ±0.01%) |
| Wavelength Options | 365, 395, 405, 420, 455, 470, 500, 520, 590, 620, 660, 740, 810, 850, 940 nm + white LED |
| Control Interface | Digital display with rotary knob adjustment |
| Modular Light Source | PCRS25 lamp housing with hot-swap capability |
| Cooling | Passive (fan-assisted, no water cooling required) |
| Uniformity | High-intensity uniform irradiation without filters or collimators |
| Temperature Control | Compatible with external cold well (optional) |
| Gas Handling | Integrated gas inlet/outlet and vacuum ports per station |
| Stirring | Dual independent magnetic stirring (speed adjustable) |
| Brand | Guochen Biotechnology |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | GCZD-A Research-Grade Fully Automated Chemiluminescence Immunoassay System |
| Pricing | Available Upon Request |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI83300 |
| Measurement Principle | Dual-mode spectrophotometric and electrochemical detection |
| Total Parameters | >55 pre-programmed water quality methods |
| Wavelength Range | 380–760 nm (visible spectrum) |
| Optical System | Fixed-wavelength LED-based photometry with precision interference filters |
| Detector | Silicon photodiode |
| Resolution | Up to 0.001 mg/L (depending on parameter) |
| Accuracy | ±2–8% of reading + offset (method-specific, per ISO 8466-1 and ASTM D511/D129/D3370) |
| Operating Temperature | 10–40 °C |
| Power | Rechargeable Li-ion battery (up to 12 h continuous use) or AC adapter |
| Data Storage | 1000 measurement records with timestamp, sample ID, and operator ID |
| Connectivity | USB port for data export (CSV format), no Bluetooth/Wi-Fi |
| Compliance | CE, RoHS, ISO/IEC 17025 compatible operation |
| Brand | Locsense |
|---|---|
| Country of Origin | Netherlands |
| Model | Artemis ST |
| AC Voltage Range | 24 V |
| Reference Electrode Input Impedance | 10–4000 Ω |
| Sensitivity | 1 |
| Input Bias Current | 234 pA |
| Frequency Range (Incubator Mode) | 10 Hz – 100 kHz |
| Frequency Range (Benchtop Mode) | 10 Hz – 1 MHz |
| Impedance Measurement Range | 10–4000 Ω |
| Channel Configuration | 1 × 24-well Transwell |
| Operating Temperature | 5–40 °C |
| Dimensions (L×W×H) | 20 × 150 × 90 mm |
| Electrode Material | Gold |
| Sterilization Compatibility | Autoclavable components in contact with cells |
| Compatible Inserts | CellQart, Corning, Greiner, NUNC, VWR 24-well Transwell plates |
| Connectivity | Ethernet, Wi-Fi, D-Sub to PC via SmartSense interface |
| Cleaning Protocol | IPA or ethanol |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-A |
| Current Range | ±250 mA |
| Potential Range | −10 V to +10 V |
| Reference Electrode Input Impedance | 10 MΩ |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| CE High-Voltage Power Supply Output | 0–20 kV / 0–300 µA |
| Photodetector HV Input | −100 to −1000 V |
| Wavelength Response Range | 300–650 nm (peak @ 420 nm) |
| Dynamic Range | >5 decades |
| Amplifier Gain | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Integration Time | 0.001–10 s |
| Sampling Rate | 1–200 Hz |
| Signal Noise | ≤0.5 mV (P-P, 1× gain) |
| Amplifier Drift | <0.05% |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-E |
| Current Range | ±250 mA |
| Potential Range | −10 V to +10 V |
| Reference Electrode Input Impedance | 10 MΩ |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 auto-ranging decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Luminescence Detection Dynamic Range | >5 decades |
| Photomultiplier Tube (PMT) High Voltage | −100 V to −1000 V |
| Emission Wavelength Range | 300–650 nm (Peak Sensitivity at 420 nm) |
| PMT Spectral Responsivity | >1000 A/lm |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-FA |
| Price | Upon Request |
| Potential Range | −1000 to +1000 mV |
| Reference Electrode Input Impedance | ≥1 × 10¹² Ω |
| Detection Sensitivity | ≤0.01 µg/kg |
| Input Bias Current | Available upon manufacturer consultation |
| Potential Increment | Available upon manufacturer consultation |
| Scan Rate | Available upon manufacturer consultation |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-S1 |
| Pricing | Available Upon Request |
| Detection Principle | Isothermal Nucleic Acid Amplification with Real-Time Fluorescence Monitoring |
| Temperature Control Accuracy | ±0.5 °C |
| Fluorescence Excitation/Emission | Dual-Channel (FAM/HEX or equivalent) |
| Sample Throughput | 1–14 samples per run, up to 5 targets simultaneously |
| Detection Time | As low as 20 min for preliminary positive call |
| Data Storage | On-device SD card + cloud synchronization (AES-256 encrypted) |
| Compliance | Designed in alignment with ISO/IEC 17025 laboratory competence requirements and GB/T 27403–2019 (China National Standard for Molecular Testing in Food Safety Laboratories) |