Glove Box
Filter
Showing all 27 results
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Category | Vacuum Glove Box |
| Application Type | Production-Scale Glove Box |
| Chamber Material | Stainless Steel (304) |
| Dimensions (L×W×H) | 1120 × 740 × 900 mm |
| Condition | Refurbished, 98% New |
| Brand | AS ONE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Number | 2-4120-11 |
| Instrument Category | Vacuum-Compatible Glove Box |
| Application Type | Research-Grade Inert Atmosphere Workstation |
| Chamber Material | Low-Density Polyethylene (LDPE) |
| External Dimensions (L×W×H) | 580 × 430 × 430 mm |
| Glove Ports | 2 |
| Gas Inlet Port Diameter | Ø8 mm |
| Sample Transfer Opening | 340 mm |
| Accessories | PVC Tubing (1 pc), Hose Clamps (2 pcs) |
| RoHS 2 Compliance | EU Directive 2015/863 |
| Brand | Cnonline |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ST-1 |
| Application Category | Research-Grade Glove Box |
| Chamber Material | 304 Stainless Steel |
| Dimensions (L×W×H) | 1200 × 640 × 1000 mm |
| Chamber Volume | 630 L |
| Antechamber Volume | 23 L |
| Number of Gloves | 1 pair |
| H₂O Content | <1 ppm |
| O₂ Content | <1 ppm |
| Leakage Rate | <0.05 vol%/h |
| Temperature Range | +4 to 42 °C |
| Relative Humidity Range | 35–100 %RH |
| Glove Material | Imported Butyl Rubber |
| Glove Diameter | 200 mm |
| Glove Thickness | 0.4 mm |
| Control Interface | Chinese-language HMI with intuitive human-machine interaction |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 34788-00 |
| Pricing | Upon Request |
| Humidity Range | 20–95% RH |
| Viewing Window | 6.35 mm (1/4″) thick acrylic, angled design |
| Glove Port Diameter | 15 cm |
| Glove Length | 61 cm |
| Right-Side Antechamber External Dimensions | 22 × 21 × 21 cm (L×W×H) |
| Main Chamber External Dimensions | 69 × 51 × 51 cm (L×W×H) |
| Weight | 65 kg |
| Gas Inlet/Outlet | Dual ball valves |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 34788-00 |
| Viewing Window | 6.35 mm (1/4") thick acrylic, angled design |
| Humidity Range Monitoring | 20–95% RH |
| Gas Inlet/Outlet Valves | 2 × 1/4" OD ball valves |
| Standard Gloves | 1 pair of medium-size latex gloves (15 cm cuff diameter, 61 cm length) |
| Transfer Chamber External Dimensions | 22 × 21 × 21 cm (L × W × H) |
| Overall External Dimensions | 69 × 51 × 51 cm (L × W × H) |
| Weight | 65 kg |
| Chamber Internal Dimensions | 68.6 × 50.8 × 50.8 cm (27 × 20 × 20 in) |
| Transfer Chamber Internal Dimensions | 68.6 × 50.8 × 50.8 cm (27 × 20 × 20 in) |
| Interface Port Size | 1/4" OD |
| Brand | Erlab |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Captair Pyramid 2200 |
| Price Range | USD 1–4999 |
| Instrument Classification | Vacuum-Compatible Glove Box |
| Application Type | Production-Grade Isolation Enclosure |
| Housing Material | High-Clarity, UV-Stabilized PVC Film |
| Dimensions (L×W×H) | 860 mm × 560 mm × 725 mm |
| Glove Ports | 1 pair (integrated ergonomic glove sleeves) |
| Leak Rate | ≤0.5% volume/hour (tested at 2.5 mmHg overpressure) |
| Certification | Factory-tested airtightness with traceable serial-numbered compliance certificate |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Captair Pyramid Portable Airtight Isolation Enclosure |
| Dimensions (L×W×H) | 860 mm × 560 mm × 725 mm |
| Application Type | Production-Scale Glove Box |
| Certification | Pre-shipment airtightness test at 2.5 mmHg gauge pressure |
| Construction | Reinforced polymer composite housing with integrated glove ports and HEPA/ULPA filtration interface |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Pyramid 2200 |
| Type | Research-Grade Glove Enclosure |
| Body Material | Reinforced PVC (High-Frequency Welded) |
| Sealing Test | Positive-pressure integrity verified at 2.5 mmHg (333 Pa) |
| Portability | Foldable, Lightweight, Single-Use Design |
| Glove Integration | Integrated welded sleeve with standard 8" diameter gloves |
| Structural Support | Dual telescopic support rods |
| Gas Inlet | Dedicated inert gas inlet valve (N₂ or Ar compatible) |
| Serial Numbering | Individually serialized for traceability |
| Compliance | Designed per ISO 14644-1 Class 5 cleanroom handling principles and ASTM E2915-21 guidelines for temporary containment integrity |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ETS |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GB12 |
| Pricing | Available Upon Request |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Model | VGB-2 |
| Acrylic Thickness | 6 mm |
| Side Door Diameter | 400 mm |
| Antechamber Dimensions | 240 mm × 240 mm (Door Opening: Ø230 mm) |
| Glove Port Diameter | 150 mm |
| Vacuum Gauges | Dual Analog Vacuum Gauges (Chamber & Antechamber) |
| Vacuum Isolation Valves | Separate Manual Shut-off Valves for Chamber and Antechamber |
| Antechamber Ultimate Vacuum | ≤0.1 mbar |
| Chamber Atmosphere | Inert Gas Purged (N₂ or Ar), No Vacuum Capability Due to Acrylic Structural Limitations |
| Net Weight | 21 kg |
| External Dimensions | 1000 mm (L) × 500 mm (W) × 500 mm (H) |
| Packaging Dimensions | 1524 mm × 864 mm × 711 mm (60" × 34" × 28") |
| Brand | Hefei Kejing |
|---|---|
| Model | VGB-2Y |
| Main Chamber Dimensions | 875 × 480 × 500 mm (L×W×H) |
| Airlock Chamber Dimensions | 230 × 230 × 230 mm (L×W×H) |
| Main Chamber Pressure Control Range | 95–101 kPa (default), min. 90 kPa (warning threshold) |
| Airlock Chamber Max Pressure | 10 kPa |
| Vacuum Gauges | Dual digital gauges (main chamber & airlock) |
| Valves | 2 solenoid valves + 1 manual valve (main chamber) |
| Power Supply | AC 110–220 V |
| Net Weight | 25 kg |
| Overall Dimensions | 1150 × 500 × 500 mm (L×W×H) |
| Construction Material | Polycarbonate viewing panels |
| Compliance | Designed for inert atmosphere handling per ISO 14644-1 Class 5 cleanroom-compatible operation |
| Optional Sensor Ports | 2 standard NPT 1/4" threaded ports in main chamber |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Model | VGB-6 |
| Chamber Volume | 3600 × 900 × 1000 mm (L × H × W) |
| Construction Material | 304 Stainless Steel (3 mm thickness) |
| Viewing Window | Dual-layer tempered glass |
| Glove Ports | Hard-anodized aluminum |
| Large Transfer Chamber | Ø360 × 600 mm |
| Small Transfer Chamber | Ø100 × 300 mm |
| Gas Purification | Regenerable 304 stainless steel columns for H₂O and O₂ removal (<1 ppm residual) |
| Purification Capacity | 1.3 kg H₂O / 30 L O₂ |
| Pressure Control Range | ±12 mbar (PLC-controlled) |
| Circulation System | Oil-free, vacuum-rated stainless steel loop (DN40) with microprocessor regulation |
| Regeneration Gas | 5–10% H₂ in working gas (N₂/Ar/He) |
| Vacuum Pump | Original equipment, 8 m³/h flow rate |
| Power Supply | 220 V AC, 50 Hz, single-phase |
| Brand | Kejing |
|---|---|
| Model | VGB-4 |
| Construction | 304 Stainless Steel |
| Chamber Dimensions (W×D×H) | 800 × 600 × 700 mm |
| Antechamber Diameter × Length | 280 × 350 mm |
| Glove Port Diameter | 145 mm |
| Operating Pressure Range | 64–110 kPa (483–825 Torr) |
| Pressure Control Accuracy | ±0.8 kPa (±6 Torr) |
| Antechamber Ultimate Vacuum | ≤0.05 Torr (≤0.067 mbar) |
| Main Chamber Ultimate Vacuum | ≤0.5 Torr (≤0.67 mbar) |
| Positive Pressure Limit | ≤111.5 kPa (≤1.1 atm) |
| Inert Gas Retention Time | >12 h |
| Net Weight | 110 kg |
| External Footprint (W×D×H) | 1200 × 1200 × 1000 mm |
| Power Supply | AC 220 V, 50 Hz |
| Integrated Components | Digital Pressure Controller, Piezoresistive Pressure Sensor, Dual Solenoid Valves, Vacuum & Gas Inlet Interfaces |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 800-DT |
| Application | Research-Grade Glove Box Systems |
| Chamber Material | Stainless Steel |
| Desiccant Medium | Molecular Sieve (3A/4A) |
| Regeneration Temperature | 160°C (320°F) for 2 hours |
| Quick-Disconnect Fitting | Self-Sealing Vacuum-Compatible Interface |
| Included Components | Vacuum Pump, Triple-Cartridge Polycarbonate Drying Tower |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 818-GB |
| Cabinet Material | Acrylic (PMMA) |
| Dimensions (L×W×H) | 1040 × 712 × 660 mm |
| Cabinet Volume | 489 L |
| Transfer Chamber Volume | 19 L |
| Glove Ports | 1 pair |
| Glove Port Diameter | 165 mm |
| Transfer Chamber Dimensions (L×D) | 300 × 280 mm |
| External Dimensions (L×H×W) | 1400 × 685 × 890 mm |
| Leak Rate | Ultra-low, monolithic acrylic construction |
| Humidity Control | None |
| Oxygen Control | Dependent on purge gas purity |
| Temperature Control | None |
| Compliance | UL/CSA-certified power outlets (220 V, 60 Hz) |
| Accessories | Vacuum gauge (on transfer chamber), one pair of Hypalon gloves, four stainless-steel isolation valves, multi-outlet medical-grade power strip |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 818-GBB |
| Application | Research-Grade Inert Atmosphere Enclosure |
| Chamber Material | 304 Stainless Steel |
| External Dimensions (L×W×H) | 193 × 81 × 119 cm |
| Internal Chamber Dimensions (L×W×H) | 152 × 79 × 96 cm |
| Chamber Volume | 1157 L |
| Transfer Chamber Dimensions (W×H×D) | 30 × 28 cm |
| Transfer Chamber Volume | ~26.9 L |
| Glove Ports | 4 × Ø16.5 cm (6.5 in) O-ring sealed |
| Glove Material | Hypalon® (chlorosulfonated polyethylene) |
| Humidity Control | <0.001% RH (dew point ≤ –70°C achievable with optional purge system) |
| Oxygen Level | <1 ppm (with integrated gas purification and continuous monitoring) |
| Leak Rate | <0.05 vol%/hr (per ASTM E493–21, helium leak test verified) |
| Viewing Window | 6.4 mm (1/4″) optical-grade acrylic, beveled for distortion-free observation |
| Integrated RH Monitor | 20–95% RH range, analog display |
| Power Outlet | UL/CSA-listed multi-outlet strip (220 V, 60 Hz, medical-grade isolation) |
| Gas Inlet/Exhaust Valves | Four 1/4″ stainless steel ball valves with stainless clamps |
| Sample Access Port | Ø30.5 cm (12″) front-loading circular access hatch with vacuum-tight valve lock |
| Vacuum Gauge | Analog Bourdon-type gauge mounted on transfer chamber |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 830-ABC |
| Application | Research-Grade Glove Box |
| Chamber Material | Acrylic (PMMA) |
| Chamber Volume | 317 L |
| Transfer Chamber Volume | Not Specified |
| Number of Gloves | 2 |
| Internal Dimensions (L×W×H) | 71 × 58 × 74 cm |
| External Dimensions (L×W×H) | 110 × 61 × 79 cm |
| Glove Port Diameter | 22.2 cm |
| Glove Length | 81 cm |
| Weight | 104 kg |
| HEPA Filter | 8" (203 mm) H14 |
| Pre-filter | 4 µm Organic Vapor & Particulate |
| Operating Pressure | Negative Pressure Mode |
| Leak Rate | Not Specified |
| Temperature Range | Ambient |
| Humidity Control | Not Integrated |
| Oxygen/Water Content Monitoring | Requires Optional Sensors |
| Vacuum Gauge Included | Yes, 28 cm Dial |
| Top Access Hatch | Yes |
| Internal Power Outlets | Yes (220 V, 60 Hz) |
| Sealing Mechanism | Stainless Steel Clamp Locks (4 valves) |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 840-PH-10 |
| Cabinet Material | Acrylic (10 mm thick) |
| Dimensions (L×W×H) | 876 × 610 × 762 mm |
| Cabinet Volume | 407 L |
| Transfer Chamber Volume | 47 L |
| Glove Quantity | 1 pair |
| Relative Humidity | 9.4% RH |
| Filtration | Dual-stage HEPA recirculation system |
| Compliance | ISO 14644-7 Class 1 (Leakage rate ≤ 5×10⁻⁴) |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 850-NB |
| Application Type | Production-Grade Glove Box |
| Chamber Material | Acrylic (PMMA) |
| Dimensions (L×W×H) | 1400 × 890 × 970 mm |
| Chamber Volume | 489 L |
| Antechamber Volume | 18.8 L |
| Glove Quantity | 1 pair |
| Relative Humidity Control | ≤9.4% RH (typical operating condition) |
| Operating Temperature | Ambient |
| Air Exchange & Purge | Dual-membrane vacuum pump system with regenerative desiccant drying |
| Desiccant System | Three replaceable PC-mounted molecular sieve cartridges with self-sealing quick-disconnect fittings |
| Lighting | Integrated “Bright Light” LED illumination (40,000 hr rated life) |
| Exhaust Valves | Four bottom-mounted purification valves |
| Antechamber Internal Dimensions | 305 mm W × Ø280 mm |
| Main Chamber Internal Dimensions | 1040 mm W × 710 mm D × 660 mm H |
| Compliance | Designed for ISO Class 5–7 cleanroom-adjacent operation |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 855-AC |
| Cabinet Material | Acrylic (PMMA) |
| External Dimensions (W×D×H) | 1400 mm × 890 mm × 970 mm |
| Internal Cabinet Volume | 489 L |
| Transfer Chamber Volume | 22 L |
| Number of Gloves | 2 |
| Residual H₂O Level | <1 ppm |
| Operating Temperature | 37 °C |
| Leak Rate | Compliant with cylinder-supplied pre-mixed gas (85% N₂ / 10% H₂ / 5% CO₂) |
| Vacuum Pumps | Dual diaphragm pumps (independent for transfer chamber and desiccant regeneration) |
| Lighting | Bright Light™ LED system (40,000 hr rated life) |
| Desiccant System | Triple regenerable molecular sieve columns with self-sealing quick-connect fittings |
| Catalyst | Heated palladium catalyst for O₂ scavenging |
| Compliance | Designed for ISO 14644-1 Class 5 clean environment operation in anaerobic workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 855-ACB |
| Application | Research-Grade Anaerobic Workstation |
| Chamber Material | Acrylic (PMMA) |
| Chamber Volume | 1157 L |
| Transfer Lock Volume | 28.3 L (Cylindrical, Ø28 cm × 30.5 cm) |
| Number of Glove Ports | 4 |
| Oxygen Level | <1 ppm (after purification cycle) |
| Water Vapor Content | <1 ppm (post-drying) |
| Temperature Control Range | 35–37 °C (catalyst heater stabilized) |
| Leak Rate | <0.01 vol%/hr (per ASTM E1997-22) |
| Glove Length | 81 cm |
| Glove Material | Hypalon® |
| Catalyst System | Palladium-on-alumina heated bed (2 units in 855-ACB) |
| Desiccant System | Triple-cartridge molecular sieve (3× 1.5 L polyamide canisters, self-sealing quick-connect) |
| Regeneration Temp | 160 °C (320 °F) for 2 hr |
| Power Input | Medical-grade UL/CSA certified, 120 VAC, 60 Hz |
| Dimensions (W×D×H) | 193 × 119 × 107 cm |
| Net Weight | 136 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 890-THC |
| Application | Research-Grade Glove Box |
| Chamber Material | Stainless Steel |
| Internal Dimensions (L×W×H) | 104 × 71 × 66 cm |
| Internal Volume | ~489 L |
| Transfer Chamber Volume | Not Specified |
| Number of Gloves | 2 (standard) |
| Temperature Range | 16–44 °C (±1 °C accuracy) |
| Humidity Range | 1–80 %RH (±2 %RH accuracy) |
| Oxygen Level | <1 ppm (anaerobic operation with integrated purge & monitoring) |
| Water Vapor Content | Controlled via integrated humidification/dehumidification system |
| Leak Rate | <0.05 vol%/hr (per ASTM E291–22 standard for inert atmosphere integrity) |
| Operating Pressure | –1.49 kPa (negative pressure design) |
| Power Supply | 220–240 V, 50 Hz, 5 A |
| Weight | 173 kg |
| Certifications | UL/CSA Listed (Medical Equipment Grade) |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 890-THC |
| Chamber Volume | 489 L |
| Transfer Chamber Volume | 19 L |
| Dimensions (L×W×H) | 1040 × 712 × 660 mm |
| Temperature Range | 16–44 °C (±1 °C accuracy) |
| Humidity Range | 1–80 %RH (±2 %RH accuracy) |
| Oxygen Level | ≤10 ppb |
| Water Vapor Content | 1–80 %RH |
| Leak Rate | Ultra-low, monolithic seamless construction |
| Glove Count | 1 pair (81 cm length) |
| Viewing Window | Acrylic transparent chamber |
| Max Operating Pressure | 1.49 kPa |
| Power Supply | 220–240 V, 50 Hz, 5 A |
| Weight | 112.5 kg |
| Compliance | UL & CSA medical-grade electrical safety certification |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Yes |
| Model | Glovebox with Gas Purification |
| Pricing | Upon Request |
| Chamber Dimensions | 1250 × 840 × 920 mm (L×W×H) |
| Operating Pressure Range | 0–16 mbar (gauge), auto-regulated |
| Purified Atmosphere | H₂O < 1 ppm(v), O₂ < 1 ppm(v) |
| Gas Circulation Rate | 70 m³/h at ΔP = 60 mbar |
| Leak Rate (Chamber) | < 0.05 vol%/h |
| Leak Rate (Purifier Unit) | < 1×10⁻⁵ mbar·L/s |
| Vacuum Pump | Two-stage oil-rotary, 12 m³/h, ultimate vacuum < 1×10⁻³ mbar |
| Regeneration Gases | N₂/H₂ (3–5% H₂) or Ar/H₂ (3–5% H₂) |
| Viewport Material | 10 mm Lexan polycarbonate |
| Glove Material | Butyl rubber, 0.4 mm thickness |
| Feedthroughs | 5 × KF-40 (2 spare, 1 gas inlet, 1 gas outlet, 1 electrical) |
| Internal Surface Finish | Electropolished SUS304 stainless steel |
| External Finish | Powder-coated SUS304 |
| HEPA Filtration | Dual circular HEPA filters for internal recirculation |
| Large Antechamber | Ø390 × 600 mm, SUS304, hard-anodized aluminum lid, manual doors, PLC-controlled vacuum/pressure equalization |
| Small Antechamber | Ø150 × 300 mm, SUS304, PLC-controlled |
| Moisture Analyzer Range | 0–1000 ppm(v) |
| Oxygen Analyzer Ranges | Trace (0–10/100/1000 ppm), Percent (0–1/10/25%) |
| Organic Adsorber | 10 kg activated carbon, KF-40 manual bypass valves |
| Brand | Vigor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Vigor Single-Station Glove Box (Flexible Solar Cell Application) |
| Pricing | Available Upon Request |
| Brand | Vigor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Vigor Single-Station Vacuum Glove Box |
| Instrument Classification | Vacuum Glove Box |
| Filtration Class | ISO Class 2 (≤0.05 vol%/h leakage rate) |
| FFU Configuration | Integrated Fan + H14 HEPA Filter + Dual-Layer Perforated Floor + Rear Gas Return Duct |
| Airflow Pattern | Unidirectional Downward Flow (UDF) with Full-Volume Coverage via Top-Mounted Flow Distributor |
| Sealing System | Patented Multi-Point Dynamic Gasket Seal |
| Gas Purification | Integrated Catalytic Oxygen/H₂O Scrubbing Module (O₂ < 1 ppm, H₂O < 1 ppm after stabilization) |
| Control System | Embedded Industrial PLC with Touchscreen HMI, Real-Time Atmosphere Monitoring (O₂, H₂O, Pressure), and Audit-Trail-Enabled Logging |