| Origin | Unknown |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | CRAWFORD-Type |
| Price | Upon Request |
| Compressed Air Reservoir Capacity | 10 L |
| Max Reservoir Pressure | 200 bar |
| High-Pressure Combustion Vessel Operating Temperature Range | –30°C to +70°C |
| Vessel Volume | 700 mL |
| Max Working Pressure (Vessel) | 250 bar |
| Proof Test Pressure | 350 bar |
| Optional Temperature Control System | CC240 |
| Temp Control Range | –40°C to +200°C |
| Thermal Chamber Volume | 5 L |
| Heating Power | 1.5 kW |
| Cooling Capacity | 1.8 kW (at 0–100°C), 0.8 kW (at –20°C) |
| Max Vacuum Flow Rate | 15 L/min at 0.4 bar |
| Max Positive Flow Rate | 18 L/min at 0.5 bar |
| Construction Materials | Stainless Steel, Ceramic, PTFE |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | MIC-200-IR3 |
| Price | Upon Request |
| Operating Voltage | DC 18–30 V |
| Operating Current | ≤30 mA (standby), ≤45 mA (alarm) |
| Spectral Range | 4–5 µm (three narrowband IR sensors) |
| Field of View | 90° |
| Detection Distance | up to 50 m (n-heptane/gasoline, 0.3 m × 0.3 m fire source), 45 m (diesel/kerosene/ethanol), 30 m (methane 0.5 m × 0.2 m, paper 0.3 m × 0.3 m) |
| Response Time | 5–10 s (medium-dependent) |
| Sensitivity Levels | 5 adjustable levels (via IR remote) |
| Output Signal | 4–20 mA (3-wire) |
| Relay Outputs | 2 SPST relays (fire alarm & fault), NO contacts, 30 VDC/AC, 3 A |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | ≤95 % RH (non-condensing) |
| EMC & Environmental Compliance | GB 16838 |
| Explosion Protection | Ex d IIC T6 Gb / DIP A20 TA, T6 |
| Ingress Protection | IP66 |
| Housing Material | Anodized aluminum alloy with anti-corrosion powder coating |
| Electrical Interface | M20 × 1.5 mm |
| Standards Compliance | GB 15631–2008, GB 3836–2000 series |
| Weight | 1.7 kg |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | FRP |
| Standards Compliance | EN ISO 9239-1, ASTM E648, ASTM E970, NFPA 253, GB/T 11785 |
| Radiation Source | Gas-fired flat-panel radiator inclined at 30° |
| Radiant Heat Flux Range | 1.1–10.9 kW/m² (extendable to 25.0 kW/m²) |
| Critical Radiant Flux Resolution | 0.1 kW/m² |
| Sample Orientation | Horizontal |
| Ignition | Pilot burner with stainless steel nozzle |
| Smoke Measurement | DIN 50055-compliant optical smoke density system mounted on exhaust duct |
| Dimensions (W×D×H) | 1900 × 750 × 1900 mm |
| Construction | Stainless steel hood, calibrated angular positioning plate, dual-access observation door with sliding platform |
| Brand | Insment |
|---|---|
| Model | KS-118D |
| Origin | Shanghai, China |
| Radiation Source Power | 500 W |
| Radiation Surface Diameter | Φ100 mm ± 5 mm |
| Sample Holder Inner Diameter | 118 mm (stainless steel ring) |
| Stainless Steel Mesh | Wire diameter 0.70 mm, aperture 2.10 mm |
| Sample Dimensions | 70 mm × 70 mm, max thickness 13 mm |
| Drip Catcher Diameter | Φ118 mm, depth 12 mm |
| Distance from Sample Upper Surface to Radiant Source | 30 mm |
| Distance from Sample Holder to Drip Catcher (cotton pad) | 300 mm |
| Heat Flux Meter Range | 10 W/cm² |
| Overall Dimensions | 1120 mm (W) × 580 mm (D) × 1350 mm (H) |
| Exhaust Port Diameter | Φ100 mm |
| Power Supply | AC 220 V, 50 Hz, ≤1000 W |
| Compliance | UN ECE Regulation No. 118, Annex 7 |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-319B |
| Origin | Shanghai, China |
| Applicable Standard | GB/T 8333–2008 |
| Burner Inner Diameter | Φ9.5 ± 0.5 mm |
| Burner Length | 102 mm |
| Adjustable Flame Height | 20–175 mm |
| Maximum Flame Temperature | 1100 °C (Bunsen burner flame at 960 °C ± 20 °C) |
| Timing Range | 0–99 min 99 sec (flame application & afterflame duration) |
| Gas Supply | Liquefied Petroleum Gas (LPG) or Town Gas |
| Air Adjustment Port | Integrated |
| Compliance | GB/T 8333–2008 (equivalent to ISO 5657:1997 for vertical flame propagation on rigid cellular plastics) |
| Warranty | 12-month parts and labor coverage |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-322A |
| Standard Compliance | GB 15442.2 |
| Test Principle | Vertical Furnace Method for Fire-Retardant Coating Performance |
| Sample Mounting | Single-Sided Coated Combustible Substrate |
| Alarm Threshold | Back-Surface Temperature ≥ 220 °C |
| Data Logging | Time-Temperature Curve Recording |
| Dimensions (L×W×H) | Test Stand 820 × 1500 mm |
| Warranty | 12-Month Parts & Labor, Lifetime Technical Support |
| Origin | Shanghai, China |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | GB/T3682-2000 |
| Temperature Control Range | 50–400 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Power Consumption | 500 W |
| Temperature Recovery Time | 4 min |
| Piston Travel Distance | 30 mm |
| Displacement Resolution | 0.1 mm |
| Barrel Inner Diameter Tolerance | ±0.025 mm |
| Piston Head Diameter Tolerance | ±0.01 mm |
| Piston Head Length Tolerance | ±0.1 mm |
| Die Capillary Inner Diameter Tolerance | ±0.005 mm |
| Standard Weights | 0.325 kg (including piston rod), 0.875 kg, 0.96 kg, 1.2 kg, 1.64 kg |
| Compliance | GB/T 3682–2000, ISO 1133:1997, ASTM D1238 |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-300F |
| Pricing | Upon Request |
| Chamber Dimensions | 300 × 1200 × 450 mm |
| Fuel Gas | High-Purity Propane or Liquefied Petroleum Gas (LPG) |
| Specimen Length | 600 ± 25 mm |
| Specimen Outer Diameter | 1–30 mm |
| Test Environment | Non-ventilated enclosure |
| Ignition Source | Calibrated propane burner with adjustable flow control (dual gas/air mass flow meters) |
| Operation Mode | Manual or Auto-select toggle switch |
| Compliance | GB/T 18380.1–2001, IEC 60332-1-2 (Ed. 3.0, 2021) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | RCF |
| Compliance | GB/T 30735-2014, ENV 1187 (t1), ISO 12468-1 |
| Sample Mounting Angle Range | 0–50° |
| Air Duct Adjustment Range | 0–35° |
| Airflow Capacity | up to 250 m³/min |
| Fan Motor Power | 5.5 kW |
| Radiation Panel Dimensions | 600 mm × 600 mm |
| Ignition Method | Electric Spark with Thermocouple-Monitored Flame Supervision |
| Wind Speed Measurement | Three Vane Anemometers (±0.1 m/s accuracy) |
| Construction Materials | SUS304 Stainless Steel Duct (2 mm thickness), Structural Steel Frame with Pneumatic & Servo-Driven Actuation |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MP-1 |
| Pricing | Upon Request |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TBB Radiant Panel Test Apparatus |
| Standard Compliance | EN ISO 9239-1 |
| Chamber Dimensions (H×W×D) | 212 × 53 × 142 cm |
| Specimen Dimensions (H×W×D) | 2.2 × 32.5 × 114 cm |
| Radiant Heat Source Temperature Range | 300–1000 °C |
| Temperature Resolution | 0.1 K |
| Heat Flux Measurement Range (Schmidt-Boelte Type) | 0–20 kW/m² |
| Light Source | 10 W Halogen Spot Lamp, Color Temperature 2900 K |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME1500-3 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HB7044-2014 |
| Pricing | Available Upon Request |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | Radiant Panel Flame Spread Apparatus |
| Compliance Standards | ASTM E162, ASTM D3675 |
| Radiation Panel Dimensions | 12 in × 18 in (305 mm × 457 mm) |
| Panel Material | Porous cement and cast iron |
| Ignition System | Electronic spark igniter with auto-shutdown safety monitoring |
| Sample Holder | Stainless steel, calibrated at 3-inch (76 mm) intervals for flame front observation |
| Thermocouple Array | Eight calibrated stainless steel thermocouples integrated into exhaust duct |
| Surface Temperature Measurement | Calibrated high-temperature pyrometer with mounting fixture |
| Gas Control | Precision methane flowmeter and adjustable gas mixture valve |
| Exhaust System | Removable-panel stainless steel ducting for maintenance access |
| Safety Systems | Interlocked gas shutoff valve and circuit-breaker activated by flame failure or overtemperature |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TTech-ISO5658 |
| Pricing | Upon Request |