Anemometer Air Flow Meter
Filter
Showing 1–30 of 390 results
| Brand | Aira |
|---|---|
| Origin | Japan |
| Model | AF303 (Omnidirectional Spherical Probe) / AF304 (Directional Probe) |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50 m/s |
| Accuracy | ±2% of reading or ±0.05 m/s, whichever is greater |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 5–24 VDC, P ≥ 5 W |
| Analog Output | 4–20 mA (max. load 300 Ω) or 1–5 V |
| Digital Output | RS-485 |
| Probe Cable Length Options | 1000 / 2000 / 3000 mm |
| Output/Power Cable Length Options | 2000 / 3000 mm |
| Probe Type | AF303 — omnidirectional spherical sensor |
| Enclosure Compatibility | Designed for wall-mount or duct-integrated installation in clean-air environments |
| Brand | Aria |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Models | AF101, AF111 |
| Wind Speed Range | 0.01–30 m/s |
| Temperature Range | −20–70 °C |
| Relative Humidity Range | 2–98 %RH |
| Wind Speed Resolution | 0.01 m/s (0.1 m/s above 10.0 m/s) |
| Accuracy | ±2 % or ±0.05 m/s (whichever is greater), ±0.5 °C, ±3 %RH |
| Operating Environment | −20–70 °C (non-condensing), 2–98 %RH |
| Response Time | 90 % in ≤1 s (wind speed 0–1 m/s), ≤60 s (RH, still air) |
| Power | 2 × AA alkaline batteries (approx. 20 h at 5 m/s, 20 °C) |
| Weight | 150 g (AF101), 175 g (AF111), incl. batteries |
| Communication | Bluetooth 4.0+, up to ~5 m line-of-sight |
| Probe | I/L dual-mode telescopic probe with mm scale markings |
| Mounting | 1/4″-20 tripod thread (also functions as hanging lug) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Instrument Type | Ultrasonic Anemometer |
| Measurement Principle | Orthogonal Acoustic Time-of-Flight |
| Axes | 3D (U, V, W) |
| Wind Speed Range | ±65 m/s (model-dependent) |
| Temperature Range | −50 °C to +70 °C (extended to +250 °C) |
| Accuracy | Wind Speed ±0.01 m/s, Orthogonality ±0.1°, Sonic Temperature ±0.05 °C |
| Resolution | Wind Speed 0.001–0.01 m/s (configurable), Wind Direction 0.1°, Temperature 0.01 °C |
| Output | RS-232C/RS-422 serial (ASCII, UART), programmable baud rate (4800–460,800 bps), data rate 1/3600 Hz to 200 Hz |
| Power | 9–32 VDC, <100 mA |
| IP Rating | Fully sealed for outdoor deployment |
| Probe Dimensions (V-model) | 17.8 × 17.8 × 17.8 cm |
| Weight | <1.0 kg |
| Compliance | Designed for GLP-aligned atmospheric research, compatible with eddy covariance systems per ASTM D5116 and ISO 16000-28 |
| Brand | BJBY |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.00–25 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±(2% of reading + 0.1 m/s) |
| Operating Temperature | 0°C to 60°C |
| Sensor Type | Constant-Temperature Anemometry (CTA) Thermal Probe |
| Power Supply | 9 V alkaline battery or 220 V AC/DC adapter |
| Battery Life | >100 hours (on 9 V battery) |
| Display | Backlit LCD, simultaneous wind speed and temperature readout |
| Weight | <1.5 kg (including carrying case) |
| Compliance | Certified by National Institute of Metrology (NIM), P.R. China (CNAS-accredited calibration traceable to SI units) |
| Brand | Davis Instruments |
|---|---|
| Origin | USA |
| Model | 6332 |
| Instrument Type | Cup Anemometer with Integrated Wind Vane |
| Resolution | 0.1 m/s |
| Measurement Range | 0.5–89 m/s |
| Accuracy | ±5% of reading (±1 m/s, whichever is greater) |
| Operating Temperature | −40 °C to +65 °C |
| Operating Humidity | 0–100% RH |
| Wireless Transmission Range | Up to 300 m (line-of-sight), 75–150 m through obstacles |
| Power Source | Solar panel (0.5 W) + rechargeable CR-123A 3 V lithium battery |
| Battery Runtime | 8 months (no solar input), ≥2 years (typical solar exposure) |
| Data Storage Capacity | 2560 records |
| Logging Intervals | 1, 5, 10, 15, 30, 60, or 120 minutes |
| Communication Interface | RS-232 or USB |
| Baud Rate | 1200–19200 bps, half-duplex |
| Sensor Cable Length | 12 m (standard), up to 73 m optional |
| Wind Direction Range | 1–360° |
| Wind Direction Accuracy | ±3° |
| Wind Direction Resolution | 1° (digital), 22.5° (16-point compass) |
| ISS Housing Material | UV-stabilized ABS and polycarbonate |
| ISS Dimensions | 159 × 58 × 200 mm |
| ISS Weight | 0.48 kg |
| Mounting Mast Diameter | 33 mm (1.3″ OD) |
| Tripod Height | 1.77 m (total), 0.92 m mast height |
| Tripod Material | Galvanized steel |
| Control Console Operating Temp | 0–+60 °C |
| Console Display | Backlit LCD (151 × 86 mm active area) |
| Console Weight | 0.85 kg (with batteries) |
| Wireless Channel Support | Up to 8 remote stations per console |
| Brand | Davis Instruments |
|---|---|
| Origin | USA |
| Model | 6410 |
| Instrument Type | Cup Anemometer with Vane-Based Wind Direction Sensor |
| Wind Speed Range | 0.5–89 m/s |
| Wind Speed Accuracy | ±1 m/s or ±5%, whichever is greater |
| Wind Speed Resolution | 0.1 m/s |
| Wind Speed Sampling Interval | 2.25 s |
| Wind Direction Range | 0°–360° |
| Wind Direction Accuracy | ±7° |
| Wind Direction Resolution | 1° |
| Wind Direction Sampling Interval | 1 s |
| Operating Temperature | −40°C to +65°C |
| Operating Humidity | 0–100% RH |
| Housing Material (Vane) | UV-Stabilized ABS |
| Cup Material | Polycarbonate |
| Arm Material | Anodized Aluminum with Black Coating |
| Cable | 4-Conductor, 26 AWG, Standard RJ11 Connector |
| Standard Cable Length | 12 m |
| Maximum Extended Cable Length | 73 m |
| Dimensions (L×W×H) | 381 mm × 38 mm × 457 mm |
| Weight | 1.332 kg |
| Brand | Davis Instruments |
|---|---|
| Origin | USA |
| Model | 7911 |
| Instrument Type | Cup Anemometer with Vane-Based Direction Sensor |
| Wind Speed Range | 0.5–89 m/s |
| Wind Speed Accuracy | ±5% or ±1 m/s (whichever is greater) |
| Wind Speed Resolution | 0.1 m/s |
| Wind Speed Sampling Interval | 2.25 s |
| Wind Direction Range | 0–360° |
| Wind Direction Accuracy | ±7° |
| Wind Direction Resolution | 1° |
| Wind Direction Sampling Interval | 1 s |
| Operating Temperature | −40°C to +66°C |
| Operating Humidity | 0–100% RH |
| Housing Material | UV-stabilized ABS (vane), Polycarbonate (cups), Anodized Aluminum (crossarm) |
| Cable | 4-conductor, 26 AWG, standard RJ11 connector |
| Standard Cable Length | 12 m |
| Maximum Extended Cable Length | 42 m |
| Dimensions | 470 mm × 191 mm × 121 mm |
| Weight | 1.332 kg |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | LAM630 / LAM630R |
| Operating Temperature Range | −30 °C to +70 °C |
| Enclosure Height | 215 mm |
| Top Diameter | 290 mm |
| Base Diameter | 250 mm |
| Total Assembled Height (with mounting post) | 440 mm |
| Fan Supply | 12 V DC, 100 mA |
| Material | UV-stabilized ABS layers + high-strength opal PMMA top shield |
| Weight (uncalibrated) | 3.0 kg |
| Weight (calibrated version) | 3.3 kg |
| Sensor Capacity | 1–4 integrated probes (temperature, relative humidity, barometric pressure, CO₂, solar radiation, precipitation detection) |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FT-QC2 |
| Price | USD 570 (FOB) |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | GMX200 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±3% |
| Operating Temperature | −35 to +70 °C |
| Operating Humidity | 0–100% RH |
| Output Interfaces | RS-232, RS-422, RS-485 (ASCII), SDI-12, NMEA 0183, Modbus RTU, Analog (optional) |
| Optional GPS Module | Altitude (m), MSL Pressure, Sunrise/Sunset, Solar Position, Twilight, Solar Noon |
| Wind Data Outputs | Apparent/True Wind Speed & Direction, WMO-Averaged Wind, Gusts, Tilt Angle |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | GMX260 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±0.3 m/s (RMSE: 0.3 m/s at 0–10 m/s |
| Operating Temperature | −35 to +70 °C |
| Operating Humidity | 0–100 % RH |
| Wind Direction Range | 0–360° |
| Wind Direction Accuracy | ±3° (0.5–40 m/s), ±5° (40–60 m/s) |
| Wind Direction Resolution | 1° |
| Output Protocols | RS232, RS422, RS485, SDI-12 v1.3, NMEA 0183, MODBUS (RTU & ASCII), ASCII |
| Output Frequency | 1 Hz, 1 min, 1 hour, or polled |
| Power Supply | 5–30 VDC |
| Power Consumption | 28 mA (nominal, 12 VDC, continuous, standard) |
| Enclosure Rating | IP66 & IP68 |
| Housing Material | UV-stabilized thermoplastic |
| Mounting | Compatible with 44.45 mm (1.75 in) mast/tube |
| Weight | 0.5 kg |
| Optional | Integrated GPS (provides position, altitude, UTC timestamp, and true wind vector correction for moving platforms) |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | HS-100 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | ±1% of reading |
| Operating Temperature | −40 °C to +60 °C |
| Operating Humidity | 0–100% RH |
| Output Frequency | 100 Hz |
| Wind Direction Range | 0–360° |
| Output Format | U/V/W orthogonal velocity components |
| Construction Material | Stainless steel |
| Compliance | Designed for GLP-compliant field deployment and long-term environmental monitoring |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | HS-50 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | ±1% of reading |
| Operating Temperature | −40 °C to +60 °C |
| Operating Humidity | 0–100% RH |
| Output Rate | 50 Hz |
| Wind Direction Range | 0–360° |
| Output Format | U, V, W vector components |
| Construction | Stainless steel |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Sampling Frequencies | 1, 2, 4, 8, 10, 16, 20 Hz (32 Hz optional) |
| Accuracy | < ±0.5% @ 20°C (Speed of Sound), < ±1° RMS (Wind Direction), < 1% RMS (Wind Speed @ ≤30° incidence) |
| Operating Temperature | -40°C to +70°C |
| Relative Humidity Range | 5%–100% RH |
| Ingress Protection | IP65 |
| Wind Speed Range | 0–45 m/s |
| Wind Direction Range | 0–359° |
| Ultrasonic Temperature Range | Not applicable (HS-50 model lacks integrated PRT) |
| Output Interfaces | RS422 full-duplex, 8 data bits, 1 stop bit, no parity |
| Baud Rate | 2400–115200 bps |
| Output Format | UVW vector components + Speed of Sound |
| Power Supply | 9–30 V DC (<150 mA @ 24 V DC or 300 mA @ 12 V DC) |
| Dimensions | 1305 mm × 344 mm × 120 mm |
| Weight | 2.5 kg |
| Housing Material | Stainless steel |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | R3-100 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | ±1% of reading |
| Operating Temperature | −40 °C to +60 °C |
| Relative Humidity Range | 0–100% RH |
| Sampling Frequency | 100 Hz |
| Output | Analog (U/V/W, sonic temperature, speed of sound), optional analog/PRT inputs |
| Construction | Aluminum alloy and carbon fiber housing |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | R3-50 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | ±1% of reading |
| Operating Temperature | −40 °C to +60 °C |
| Operating Humidity | 0–100% RH |
| Output Rate | 50 Hz |
| Output Parameters | U, V, W, Sonic Temperature (SOS) |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–50 m/s |
| Accuracy | ±1.5% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Output Frequency | 20 Hz (32 Hz optional) |
| Outputs | U, V, W velocity components, sonic temperature, speed of sound |
| Construction | Aluminum alloy and carbon fiber housing |
| Calibration | Optional traceable wind tunnel calibration per unit |
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster HS |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | <1.5% RMS @ 12 m/s |
| Operating Temperature | −40 °C to +70 °C |
| Relative Humidity | 5–100% RH |
| IP Rating | IP65 |
| Output Frequency | Up to 32 Hz |
| Ultrasonic Temperature Range | −40 °C to +70 °C |
| Wind Direction Accuracy | 2° @ 12 m/s (standard), 0.5° @ 12 m/s (customizable) |
| Sonic Temperature Resolution | 0.01 °C |
| Sound Speed Accuracy | < ±0.5% @ 20 °C |
| Sampling Frequency | 20 Hz or 32 Hz (user-selectable) |
| Analog I/O | 4-channel 14-bit ADC (input/output configurable) |
| Digital Interface | RS-232/422/485, ASCII or binary protocol, baud rate 2400–57600 |
| Power Supply | 9–30 VDC, 55 mA @ 12 VDC |
| Dimensions | 956 × 347 × 120 mm |
| Weight | 2.96 kg |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster HS |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–45 m/s |
| Accuracy | ±1% of reading |
| Operating Temperature | −40 °C to +60 °C |
| Operating Humidity | 5–100% RH |
| Output Frequency | 32 Hz |
| Output Signals | U, V, W vector components, sonic temperature |
| Housing Material | Stainless steel |
| Analog I/O | 4-channel integrated electronics |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster Pro |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–65 m/s |
| Accuracy | ±1.5% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Output Frequency | 32 Hz |
| Output Parameters | U, V, W velocity components, sonic temperature, speed of sound |
| Housing Material | Stainless steel |
| Optional Calibration | Traceable wind tunnel calibration (Gill-certified) |
| Analog I/O & PRT Resolution | 14-bit |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindMaster RA |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0 – 50 m/s |
| Accuracy | ±1.5% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Output Frequency | Standard 20 Hz (optional 32 Hz) |
| Output Parameters | U, V, W velocity components, sonic temperature, speed of sound |
| Construction Material | Anodized aluminum and carbon fiber composite |
| Calibration | Optional traceable wind tunnel calibration per unit |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver 65 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–65 m/s |
| Accuracy | ±2% |
| Operating Temperature | −55 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Ingress Protection | IP66 |
| Material | Stainless Steel |
| Compliance | WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008) |
| Output | Digital (RS-232/RS-485, SDI-12, or optional Modbus RTU) |
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver 70 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55°C to +70°C |
| Operating Humidity | 0–100% RH |
| Heating Power | 150 W (1 W/cm²) |
| Electrical Input | 7 A @ 24 VAC/DC |
| Wind Direction Range | 0–360° (dead-zone-free) |
| Calibration | NIST-traceable |
| Enclosure Material | Stainless steel |
| Ingress Protection | IP66 |
| Compliance | FAA AC 150/5220-9C, UK CAA CAP 744, ICAO Annex 3, WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No.8, 7th ed., 2008) |
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver 75 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| IP Rating | IP66 |
| Heating Power | 150 W (7 A @ 24 VAC/DC, ~1 W/cm²) |
| Output Interface | RS422/RS485 (half-duplex, multi-drop capable) |
| Wind Direction Range | 0–359° (continuous, no dead zone) |
| Calibration | NIST-traceable |
| Compliance | WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008) |
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver 90 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0 – 90 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Heating Power | 150 W (7 A @ 24 VAC/DC, ~1 W/cm²) |
| Wind Direction Range | 0–360° (continuous, no dead zone) |
| Calibration | Traceable to NIST, performed in Merlin wind tunnel |
| Enclosure Material | Stainless steel (AISI 316) |
| Ingress Protection | IP66 |
| Output Interface | RS-422 / RS-485 (half-duplex, multi-drop capable) |
| Compliance | Meets WMO standards for mean wind and gust reporting |
| Mounting Options | Multiple base configurations available |
| Cable/Connector Options | Field-selectable |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindObserver II |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–65 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Ingress Protection | IP66 |
| Housing Material | Stainless Steel |
| Certification | Lloyds Register Type Approved |
| Output Interfaces | 1 digital (RS-422/RS-485), 3 analog (4–20 mA or 0–10 V) |
| WMO Compliance | Wind averaging and gust algorithms aligned with WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008) |
| Optional Feature | Integrated de-icing system |
| Brand | Gill |
|---|---|
| Origin | UK |
| Model | WindObserver IS |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0 – 75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −30 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Certifications | ATEX II 2 G IIC T4 Ga, IECEx EXA 20.0029X, UKEX 20ATEX0002X |
| Compliance | UK CAA CAP 437, WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8, 7th Ed., 2008) |
| Output Options | Gill Serial Protocol, NMEA 0183, 4–20 mA (isolated), RS-485 |
| Power Supply | 12–30 VDC or 24 VAC |
| Ingress Protection | IP66 |
| Expected Service Life | >10 years in offshore environments |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindSonic 75 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Output Options | RS-232/RS-485 serial, dual analog (4–20 mA or 0–5 V), NMEA 0183 compliant |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindSonic M |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±2% |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Ingress Protection | IP66 |
| Vibration Compliance | BS EN 60945:2002 |
| Impact Resistance | UL 2218 Class 1 |
| Output Protocols | NMEA 0183 (standard), Analog Output (optional) |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindSonic |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±2% @ 12 m/s |
| Operating Temperature | −35 to +70 °C |
| Relative Humidity Range | 5–100% RH |
| Output Options | RS-232/RS-485 serial, dual analog (4–20 mA or 0–5 V) |
| Status Code | Integrated diagnostic flag per data packet |
| Housing Material | UV-stabilized polycarbonate |
| Moving Parts | None |
| Compliance | IP66 rated, CE marked, RoHS compliant |