Concentrators
Filter
Showing 1–30 of 160 results
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AE100 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Sample Capacity per Vial | 100 mL |
| Brand | ANAYN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CYNS-16K |
| Instrument Type | Vacuum Parallel Evaporator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Throughput | 16 × 150–200 mL samples |
| Vacuum Pump Flow Rate | 20–30 L/min |
| Ultimate Vacuum | ≤8 mbar |
| Condensation System | Dual-tower cold trap with recirculating chiller |
| Display | 7-inch capacitive touchscreen interface |
| Sealing Interface | PFA-coated lid with threaded glass tube coupling |
| Chamber Volume | ≥8 L, triple-transparent viewing window |
| Safety Features | Low-water-level alarm, solvent recovery buffer bottle, PTFE diaphragm vacuum pump, PEEK/PTFE/glass fluid path |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | SC-4223 |
| Instrument Type | Automated Quantitative Gas Preconcentrator |
| Cold Trap Temperature Range | −30 °C to 300 °C (at 25 °C ambient) |
| Valve & Transfer Line Temperature Range | Ambient to 160 °C |
| Cooling Method | Peltier Thermoelectric |
| Sample Volume | 1–2000 mL |
| Maximum Concentration Ratio | 2000:1 |
| Precision | RSD ≤ 3% |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 550 × 260 × 427 mm |
| Weight | ~20 kg |
| Interface Options | RS-232, Ethernet |
| GC Trigger Modes | Time-based or GC reverse control |
| Analysis Time Range | 0.1–999 min |
| Max Power Consumption | 1000 W |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | SC-4224 |
| Instrument Type | Automated Quantitative Gas Preconcentrator |
| Temperature Range (Valve & Tubing) | +5°C to 160°C |
| Cold Trap Temperature Range | −50°C to 300°C |
| Sample Volume Capacity | 1–2000 mL |
| Concentration Ratio | Up to 2000:1 |
| Temperature Control Accuracy | RSD ≤3% |
| Reproducibility | RSD ≤3% |
| Sample Introduction | Vacuum Pressure Sampling with MFC Flow Control |
| Cooling Method | Compressor-based |
| Dimensions (W×D×H) | 550 × 260 × 427 mm |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 1000 W |
| Weight | ~40 kg |
| Compliance | GB/T 14678–1993 |
| Brand | ANYAN (Hangzhou Anyan Instrument Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-25K |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Oscillation Speed | 0–300 rpm |
| Sample Capacity | 25 positions (150–200 mL vials) |
| Timer Range | 0–999 min |
| Heating Method | Water Bath |
| Included Systems | Integrated Vacuum Pump, Dual-Tower Condensation Module, Closed-Loop Water Circulation Chiller |
| Brand | Anyan Instrument |
|---|---|
| Origin | Zhejiang, China |
| Model | CHNS-25K |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity | 25 × 150–200 mL |
| Timing Range | 0–999 min |
| Heating Method | Circulating Water Bath |
| Condensation System | Dual-Tower Cold Trap with External Recirculating Chiller Support |
| Sealing Architecture | Individual Sample-Specific Vacuum Seals |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Anyanyiqi |
|---|---|
| Origin | Zhejiang, China |
| Model | CHNS-16K |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity per Vial | 150 mL or 200 mL |
| Throughput | 1–16 samples simultaneously |
| Timer Range | 0–999 min |
| Heating Method | Water Bath |
| Brand | ATR |
|---|---|
| Origin | USA |
| Model | AutoVap S8 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 99°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Volume Capacity | 0–50 mL (standard), optional 0–200 mL |
| Endpoint Detection | 0.5 mL or 1.0 mL optical sensing |
| Parallel Channels | 8 independent channels |
| Concentration Speed | 3–5× faster than conventional nitrogen blow-down systems |
| Sample Recovery Rate | ≥90% (typical, matrix-dependent) |
| Endpoint Precision | <5% volume error |
| Brand | ATR |
|---|---|
| Origin | USA |
| Model | S60 |
| Instrument Type | Automatic Quantitative Concentrator |
| Temperature Range | Ambient to 99°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Volume Capacity | 0–60 mL |
| Heating Method | Water Bath (Manufactured in Singapore) |
| Power Rating | 800 W |
| Gas Flow Rate | 0–8 L/min |
| Compatible Tube Sizes | 1.5 mL to 50 mL |
| Application Fields | Environmental (EPA), Pharmaceutical (FDA, USP), Clinical (CDC), Food Safety, Academic Research, and Chemical Analysis |
| Brand | Ji Aim |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Auto C1 |
| Price Range | USD 28,000 – 56,000 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 70°C |
| Temperature Control Accuracy | ±2°C |
| Rotational Speed | 1500 rpm |
| Vacuum Display Range | 0.1–99.9 mbar |
| Vacuum Control | Yes |
| Heating Power | 1500 W |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Dimensions (W×D×H) | 657 × 518 × 465 mm |
| Lid Opening Mechanism | Vertical Lift |
| Positioning Accuracy | <1 mm |
| Rotor Configuration | Horizontal Dual-Plate Carrier (2 × 96-well Deep-Well Plates or Sample Vial Baskets) |
| Corrosion Resistance | Solvent-Compatible Materials (e.g., PTFE-coated Seals, 316 Stainless Steel Components) |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Auto EVA 80 |
| Instrument Type | Automated Quantitative Nitrogen Evaporator |
| Temperature Range | Contact for Specification |
| Temperature Control Accuracy | Contact for Specification |
| Sample Capacity | Up to 80 Positions (Compatible with Standard 15 mL Conical Tubes) |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | Auto EVA-60 |
| Quotation | Upon Request |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity per Vial | 80 mL |
| Throughput | Up to 60 Samples Simultaneously |
| Brand | BIOCOOL |
|---|---|
| Origin | Tianjin, China |
| Model | FastDry-1 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to –80 °C |
| Temperature Control | Gradient PID Control |
| Sample Capacity | 132 × 1.5 mL tubes |
| Vacuum Pump Options | Diaphragm or Direct-Coupled Rotary Vane Pump |
| Ultimate Vacuum | <10 Pa |
| Rotational Speed | 400–1800 rpm (variable frequency drive) |
| Chamber & Rotor Coating | PTFE (Teflon®) |
| Control Interface | 7-inch Industrial Touchscreen + PLC |
| Safety Features | Vacuum-delayed spin initiation, Auto Venting, Overheat/Overpressure/Imbalance Protection |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | BIOCOOL |
|---|---|
| Origin | Tianjin, China |
| Model | FastDry-1E |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to –80 °C |
| Temperature Control | Gradient PID Control |
| Sample Capacity | 132 × 1.5 mL tubes |
| Vacuum Pump Options | Diaphragm or Direct-Coupled Rotary Vane Pump |
| Vacuum Limit | <10 Pa |
| Rotational Speed Range | 400–1800 rpm (optional) |
| Chamber & Rotor Coating | PTFE (Teflon®) |
| Control Interface | 7-inch Industrial Touchscreen + PLC |
| Safety Features | Vacuum Delay Start, Auto Venting, Over-Temp & Over-Speed Protection |
| Compliance | GMP-Compatible Design, FDA 21 CFR Part 11–Ready Software Architecture (with optional audit trail module) |
| Brand | BIOCOOL |
|---|---|
| Origin | Tianjin, China |
| Model | FastDry-2 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 4°C to 80°C |
| Temperature Control | Gradient PID Control |
| Sample Capacity | 132 × 1.5 mL tubes |
| Vacuum System | Compatible with diaphragm or direct-coupled rotary vane pumps |
| Display | Touchscreen interface |
| Control Architecture | PLC-based automation |
| Safety Features | Auto-vacuum release, magnetic drive seal, ice crystal prevention logic (vacuum initiation only after target speed achieved) |
| Chamber & Rotor Coating | PTFE (Teflon®)-coated for chemical resistance and sterilizability |
| Rotors | Up to 50 rotor types auto-recognized |
| Optional Modules | Ultra-low temperature condenser (< −110°C), cryogenic thermostat (−4°C to +4°C), endpoint detection, vacuum oil mist filter, and process optimization support |
| Brand | BIOCOOL |
|---|---|
| Origin | Tianjin, China |
| Model | FastDry-3 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 4°C to 80°C |
| Temperature Control | Gradient PID Control |
| Sample Capacity | 132 × 1.5 mL tubes |
| Vacuum Pump | Direct-coupled rotary vane pump |
| Display | Touchscreen interface |
| Control Mode | Multi-stage programmable (12 segments) |
| Rotor Recognition | Auto-identification for up to 50 rotor types |
| Chamber & Rotor Coating | PTFE (Teflon®)-coated |
| Cold Trap Compatibility | Optional ultra-low temperature condenser (< −110°C) |
| Safety Features | Vacuum interlock (vacuum applied only after target speed reached), automatic venting, overload/overheat protection |
| Compliance | Designed for GLP/GMP environments |
| Brand | BIOCOOL |
|---|---|
| Origin | Tianjin, China |
| Model | FastDry-3E |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 4°C to 80°C |
| Temperature Control | Gradient PID Control |
| Sample Capacity | 132 × 1.5 mL tubes |
| Vacuum Source | Direct-coupled rotary vane pump |
| Display | LED panel |
| Control Mode | Single-stage programmable |
| Auto Venting | Yes |
| Cold Trap Compatibility | Optional (−50°C / −80°C / <−110°C) |
| Rotor Coating | PTFE (Teflon®) |
| Safety Features | Vacuum interlock, overtemperature protection, rotor imbalance detection, automatic vacuum release |
| Brand | BIOCOOL |
|---|---|
| Origin | Tianjin, China |
| Model | FastDry-4 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 4°C to 80°C |
| Temperature Control | Gradient PID Control |
| Sample Capacity | 132 × 1.5 mL tubes |
| Vacuum Pump Options | Diaphragm or Direct-Coupled Rotary Vane Pump |
| Cold Trap Compatibility | Optional −50°C / −80°C / <−110°C cryo-traps |
| Safety Features | Vacuum-delayed spin-up, Auto venting, Magnetic drive seal, Corrosion-resistant PTFE-coated chamber & rotors |
| Control Interface | Industrial touchscreen + PLC |
| Programmability | 12-step customizable protocol per run (speed, temp, vacuum, time) |
| Rotor Recognition | Supports ~50 rotor types |
| Mobile Monitoring | Remote status tracking via smartphone app |
| Compliance | Designed for GLP/GMP environments |
| Brand | BIOCOOL |
|---|---|
| Origin | Tianjin, China |
| Model | FastDry-4E |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 4°C to 80°C |
| Temperature Control | Gradient PID Control |
| Sample Capacity | 132 × 1.5 mL tubes |
| Vacuum Pump Options | Diaphragm or Direct-Coupled Rotary Vane Pump |
| Control Interface | Industrial Touchscreen + PLC |
| Programmability | 12-Stage Customizable Protocol |
| Safety Features | Vacuum Delay Start, Auto Venting, Over-Temp & Over-Pressure Protection |
| Cold Trap Compatibility | Optional –55°C, –80°C, or <–110°C Ultra-Low-Temperature Condenser |
| Rotor Recognition | Up to 50 Rotor Types Auto-Detected |
| Chamber & Rotor Coating | PTFE (Teflon®) Anti-Corrosion Finish |
| Rotational Speed Range | 400–1800 rpm (Variable Frequency Drive) |
| Ultimate Vacuum | <10 Pa |
| Compliance | Designed for GLP/GMP environments |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera Prime |
| Instrument Type | Automated Flash Chromatography System |
| Flow Rate | 1–100 mL/min |
| Maximum System Pressure | 10 bar (150 psi) |
| UV Detection Range | 200–400 nm (standard), optional 200–800 nm |
| Gradient Capability | Dual-solvent channels with TLC-driven gradient generation |
| Fraction Collection Options | 13 mm, 16 mm, 18 mm, 25 mm test tubes |
| Display | 10.4-inch capacitive touchscreen |
| Operating System | Embedded Linux |
| Connectivity | Ethernet-enabled for remote control, data logging, and network printing |
| Compliance | Compatible with GLP/GMP workflows via audit trail-ready software architecture |
| Brand | Biotage |
|---|---|
| Origin | United Kingdom |
| Model | TurboVap II |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 90 °C |
| Temperature Control Accuracy | ±2 °C |
| Brand | Biotage |
|---|---|
| Origin | USA |
| Model | V-10 Touch |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 0–1000 mL |
| Built-in Vacuum Pump | 2 mbar ultimate pressure |
| Maximum Rotor Speed | 8000 rpm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BO-HM-01 |
| Pricing | Upon Request |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SyncorePlus R-12 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 20–100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume Capacity per Vial | 0.5–500 mL |
| Vacuum Range | 1 mbar to atmospheric pressure |
| Rotational Speed | 60–400 rpm |
| Final Vacuum (Absolute) | 8 mbar |
| Pump Flow Rate | 1.8 m³/h |
| Cooling Unit Temp. Range | −10 to +25 °C |
| Cooling Capacity @ 15 °C | 800 W |
| Power Supply | 220–240 V, 50/60 Hz, Max 1400 W |
| Brand | Chengmeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Chengmeng CM-12PUS Automated Nitrogen Evaporator |
| Instrument Type | Automated Quantitative Sample Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Volume Capacity per Vial | 50–150 mL |
| Maximum Simultaneous Samples | 64 (configurable: 12/24/36/64 positions) |
| Nitrogen Input Pressure Range | 7–145 psi |
| Output Pressure Range | 0–72.5 psi |
| Heating Power | 2200 W |
| Display | 8-inch HD Touchscreen (800×480 resolution) |
| Sample Detection | Optical Fiber Sensor for Endpoint Detection at 0.5 mL or 1.0 mL |
| Water Bath Material | Stainless Steel |
| Control Modes | Manual & Automatic |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Chengmeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CM-24PUS Automated Nitrogen Evaporator |
| Instrument Type | Automated Quantitative Sample Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Volume Capacity | 1–200 mL |
| Sample Positions | Up to 24 parallel channels (configurable: 12/24/36/64 positions) |
| Heating Method | PID-Controlled Water Bath |
| Display | 8-inch HD Touchscreen (800×480 resolution) |
| Gas Control | Electromagnetic Valves with Real-Time Pressure & Flow Monitoring |
| Pressure Input Range | 7–145 psi |
| Output Pressure Range | 0–72.5 psi |
| Power Supply | 220 V / 110 V, 50 Hz |
| Rated Power | 2200 W |
| End-Point Detection | Optical Fiber Sensors for 0.5 mL and 1.0 mL auto-shutoff |
| Safety Features | Low-water-level alarm, over-temperature cutoff, dry-run protection, auto-drain module |
| Brand | Chengmeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CM2001 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 95 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity per Vial | Up to 50 mL |
| Maximum Parallel Channels | 60 |
| Heating Method | Water Bath |
| Gas Control | 12 Independent Solenoid-Valve-Controlled Channels (5 Nozzles per Channel) |
| Gas Pressure Range | 0–0.1 MPa (Adjustable in 0.01 MPa Steps) |
| External N₂ Supply Requirement | 0.2–0.8 MPa |
| Gas Consumption | ~500 mL/min per nozzle at 0.1 MPa |
| Auto-Replenishment | Integrated Level-Sensing Water Refill System |
| Safety Interlocks | Lid-Activated Pause/Resume, Low-Water & Low-Pressure Alarms |
| Display | Full-Color Touchscreen Interface |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 730 × 500 × 380 mm |
| Weight | 30 kg |
| Brand | Chengmeng Technology |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CMDS-12D |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Vessel Capacity | 50 mL or 150 mL |
| Heating Method | Dry-block (water bath optional) |
| Endpoint Detection | Optical sensor per channel |
| Adjustable Endpoint Volume | 1.0 mL, 0.5 mL, or near-dry (~0.1 mL) |
| Nitrogen Pressure Range | 0–0.1 MPa (adjustable in 0.01 MPa increments) |
| Inlet Gas Requirement | 0.2–0.8 MPa |
| Gas Consumption | ~500 mL/min per channel at 0.1 MPa |
| Endpoint Sensitivity | 10-level optical threshold adjustment |
| Power Supply | 220 V / 60 Hz |
| Dimensions | 650 × 450 × 308 mm |
| Weight | 21 kg |
| Brand | Chengmeng Technology |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | CMDS-24D |
| Instrument Category | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity per Vial | 150 mL |
| Heating Method | Dry-Block (Water Bath Optional) |
| Endpoint Detection | Optical Sensor per Channel |
| Adjustable Endpoint Volumes | 1.0 mL, 0.5 mL, or Near-Dry (~0.1 mL) |
| Nitrogen Pressure Control | 0–0.1 MPa (adjustable in 0.01 MPa increments) |
| Inlet N₂ Supply Requirement | 0.2–0.8 MPa (max tolerance: 1.0 MPa) |
| Gas Consumption | ~500 mL/min per channel at 0.1 MPa |
| Endpoint Sensitivity | 10-Level Adjustable |
| Dimensions | 650 × 450 × 308 mm |
| Weight | 21 kg |
| Brand | Chu Ding |
|---|---|
| Model | HPE-03 |
| Instrument Type | Automated Quantitative Concentrator |
| Heating Temperature Range | RT + 5 °C to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Rotation Speed | 50–420 rpm |
| Orbit Diameter | 5 mm |
| Power Consumption | 1100 W |
| Net Weight | 32 kg |
| Dimensions (W×D×H) | 380 × 510 × 420 mm |
| Sample Capacity | 6 positions, 250 mL per tube |
| Solvent Recovery | Integrated condensation system |
| Operation Mode | Digital timer-controlled, vacuum-assisted evaporation |
| Compliance | Designed for GLP-compliant labs |