Food Specialized Instruments
Filter
Showing 1–30 of 290 results
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuPoint |
| Price | Upon Request |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | AQT200 |
| Package Quantity | 100 swabs per box |
| Storage Conditions | 2–8 °C (refrigerated) for up to 12 months |
| Intended Use | Total ATP quantification in rinse water and surface rinse samples from food processing equipment and CIP systems |
| Compatible Instrument | 3M Clean-Trace NG Luminometer |
| Output Unit | Relative Light Units (RLU) |
| Regulatory Context | Designed for use in environments compliant with HACCP, GMP, and FDA 21 CFR Part 11–aligned data integrity workflows |
| Application Scope | Food & beverage manufacturing, dairy, meat & poultry, seafood, produce, beverages, bottled water, pet food, nutraceuticals, and bakery |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | AQT200 |
| Package Quantity | 100 swabs per box |
| Storage Conditions | 2–8 °C (refrigerated) for up to 12 months |
| Intended Use | Total ATP quantification in rinse water and surface rinse samples from food processing equipment and CIP systems |
| Compatible Instrument | 3M Clean-Trace NG Luminometer |
| Output Unit | Relative Light Units (RLU) |
| Compliance Context | Designed for use in HACCP, GMP, and FSMA-aligned environmental monitoring programs |
| Application Scope | Food & beverage manufacturing, dairy, meat & poultry, seafood, produce, beverages, confectionery, pet food, and ingredient processing facilities |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | Clean-Trace ATP LM1 |
| Detection Principle | ATP-dependent bioluminescence assay |
| Sample Types | Surface swabs (UXL100), total aqueous ATP (AQT200), free aqueous ATP (AQF100) |
| Compliance | Designed for use in food safety hygiene monitoring per ISO 22000, HACCP, and FDA Food Code guidance |
| Software | 3M Clean-Trace Hygiene Management Software with wireless data sync, audit-trail-capable reporting, and 21 CFR Part 11–ready configuration options |
| Portability | Handheld, battery-operated, integrated cradle charging station |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | Clean-Trace ATP LM1 |
| Detection Principle | ATP-dependent bioluminescence assay |
| Sample Types | Surface swabs (UXL100), water samples (AQT200, AQF100) |
| Data Connectivity | Wireless (Bluetooth/Wi-Fi enabled) |
| Software Platform | 3M Clean-Trace Hygiene Management Software |
| Compliance Support | Designed for use in environments requiring adherence to HACCP, ISO 22000, FDA Food Code, and GMP-aligned hygiene verification protocols |
| Power | Rechargeable battery with AC adapter |
| Portability | Handheld, ergonomic design for single-hand operation |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | LM1 |
| Detection Principle | ATP-dependent luciferase bioluminescence assay |
| Sample Types | Surface swabs (UXL100), free ATP in water (AQF100), total ATP in water (AQT200) |
| Software | Clean-Trace Hygiene Management Software with wireless connectivity, automated reporting, and audit-ready data logging |
| Compliance Context | Designed for use in environments requiring adherence to HACCP, ISO 22000, FDA Food Safety Modernization Act (FSMA), and GMP-aligned hygiene verification protocols |
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Clean-Trace™ |
| Pricing | Upon Request |
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 3M™ Clean-Trace™ NGI |
| Pricing | Available Upon Request |
| Weight | 400 g |
| Detection Range | 0–999,999 RLU |
| Sensitivity | 10⁻¹⁵ mol ATP |
| Read Time | 10 s |
| Repeatability (CV%) | 7.4% |
| Data Storage | 10,000 test results |
| Sampling Plans | 100 plans (up to 300 points each) |
| Plan Points | 2,000 total |
| Display | 240 × 160-pixel backlit LCD |
| Battery | Rechargeable Li-ion, 36 h continuous operation |
| Auto-Diagnostics | Power-on self-test & real-time fault alerting |
| Sample Chamber | Auto-sensing lid with timeout alarm |
| Software | Trend analysis with 9 filtering modes, 5 report templates, 10 chart types, Excel export |
| User Management | Customizable role-based permissions |
| ATP Reagent Format | Pre-loaded liquid luciferin/luciferase in swab |
| Brand | AGDIA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XCS66800/0048 |
| Price Range | USD 999–9,999 |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | EOPC® Automated Polar Compound Separation System |
| Detection Principle | Normal-phase liquid chromatography with UV detection (200 nm) |
| Column Format | Standardized disposable EOPC separation cartridges (pre-packed silica-based) |
| Automation Level | Fully automated sample injection, gradient elution, fraction collection, and real-time UV monitoring |
| Throughput | Up to 6 samples unattended |
| Compliance | Designed to meet requirements of GB 5009.202–2016 “Determination of Polar Compounds in Edible Oils” |
| Solvent Management | Dual 4 L solvent reservoirs with dry-ice–assisted cooling (4 °C to ambient) |
| Flow Control | Valveless precision metering pump (±0.5% flow accuracy, 25 mL/min max) |
| Fraction Collection | Programmable S-type collector with coordinate customization, multi-channel waste/collect switching, compatibility with conical flasks, round-bottom flasks, and beakers |
| UV Detector | Fixed-wavelength 200 nm detector with real-time chromatogram display |
| Display | Integrated LED touchscreen showing pressure, flow rate, gradient profile, and run progress |
| Safety Design | Fully enclosed fluidic path |
| Software | Embedded method library including GB 5009.202–2016-compliant SOPs |
| audit-trail–capable operation log (GLP-supporting metadata | user ID, timestamp, method version, instrument parameters) |
| Brand | AIRSENSE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | IRS1200 |
| Pricing | Available Upon Request |
| Brand | Alpha MOS |
|---|---|
| Origin | France |
| Distribution Model | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ASTREE |
| Pricing | Available Upon Request |
| Brand | Alpha MOS |
|---|---|
| Origin | France |
| Distribution Type | Authorized Distributor |
| Import Status | Imported |
| Model | IRIS |
| Pricing | Available Upon Request |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | CINAC |
| Automation | Fully Automatic |
| Analysis Speed | 16 samples/min |
| Measurable Parameters | Temperature, pH, Redox Potential |
| Repeatability | <0.5% CV |
| Accuracy | <1.0% |
| Input Voltage | 110–220 V AC ±15%, 50–60 Hz |
| Dimensions (L×W×H) | 35 × 26 × 15 cm |
| Weight | 3.5 kg |
| Channel Configuration | Up to 16 pH electrodes (CINAC16), or mixed configurations (e.g., CINAC12: 12 pH + 4 Pt100 |
| CINAC14 | 14 pH + 2 Pt100) |
| Data Acquisition | Real-time logging of pH, temperature, and redox across 1–16 (expandable to 32 via dual-unit PC integration) channels |
| Calibration Traceability | Factory-calibrated against certified reference standards |
| Compliance | Designed in collaboration with INRA-LGMPA (France) |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | APN-C |
| Price | USD 8,400 (approx. based on ¥59,800 at 1 USD = ¥7.1) |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | APN-I |
| Price | USD 1,400 (approx.) |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | APN-III |
| Price | USD 8,400 (approx.) |
| Function Type | Multi-analyte (simultaneous detection of multiple contaminants) |
| Sample Compatibility | Universal for liquid and homogenized food matrices |
| Wavelengths | 410 nm, 538 nm, 590 nm |
| Detection Time | ≤30 minutes per batch |
| Repeatability | ≤1% RSD |
| Detection Channels | 12-position automatic cuvette holder |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ≤±0.05 nm |
| Detector | Imported CCD sensor |
| Display | 10.1-inch high-resolution LCD |
| Interfaces | RS-232, USB 2.0, built-in thermal printer |
| Power Supply | 12 V DC (including automotive 12 V input) |
| Enclosure | Industrial-grade aluminum alloy portable case |
| Brand | ANPRO |
|---|---|
| Model | APN-M |
| Detection Principle | Colloidal Gold Immunochromatographic Quantitative Assay |
| Target Analyte | Lead (Pb) |
| Detection Limit | 0.02 ppm |
| Quantitative Range | 0–1 ppm |
| Sample Type | Preserved mustard greens and other food matrices |
| Display | Color resistive touchscreen |
| Data Output | Built-in thermal printer |
| Reagent Storage | Ambient-temperature stable test strips |
| Regulatory Alignment | Compliant with GB 5009.12–2023 (China National Food Safety Standard for Determination of Lead in Foods), supports GLP-aligned documentation workflows |
| Origin | Sichuan, China |
| Manufacturer | ANPRO Biotechnology Co., Ltd. |
| Category | Food-Specific Heavy Metal Rapid Detector |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | APN-R |
| Detection Targets | Lead (Pb), Chromium (Cr), and Multi-analyte Screening in Milk & Dairy Products |
| Automation Level | Semi-automatic |
| Throughput | 60 Samples/Hour |
| Detection Range (Pb) | 0–1 ppm (mg/kg) |
| Detection Range (Cr) | 0–5 ppm (mg/kg) |
| Repeatability (CV) | <3% |
| Accuracy | >80% |
| Onboard Storage | 2 GB |
| LOD (Pb in raw/pasteurized/UHT milk) | 0.001 ppm |
| LOD (Pb in other dairy matrices) | 0.01 ppm |
| LOD (Cr) | 0.1 ppm |
| Assay Time | 6 min per test |
| Reaction Temperature | 37 °C |
| Calibration | Pre-loaded multi-point standard curves for Pb, Cr, and 12+ additional analytes (e.g., Aflatoxin M1, Chloramphenicol, Melamine) |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | APN-S |
| Price | USD 6,800 (FOB) |
| Brand | Anpro |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | EV-X |
| Pricing | Upon Request |
| Brand | Anpro |
|---|---|
| Model | EV-X |
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Automated Immunoassay Analyzer for Mycotoxins, Heavy Metals & Pesticide Residues |
| Compliance | GB 2761–2017, GB 2762–2022, LST 6111–2015 to LST 6114–2015, LST 6144–2023, LST 6145–2023 |
| Throughput | ≥20 samples/hour (40 test results/hour) |
| Sample Capacity | 10 independent reaction channels |
| Detection Principle | Quantitative Enzyme-Linked Immunosorbent Assay (ELISA) with photometric readout |
| Sample Types | Cereals, oilseeds, feedstuffs, edible oils, dairy products, traditional Chinese medicinal materials |
| Key Analytes | Aflatoxin B₁, Aflatoxin M₁, Total Aflatoxins, Deoxynivalenol (DON), Zearalenone (ZEN), Fumonisins, Ochratoxin A, T-2 Toxin, Pb, Cd, Cr, Cu, Acetamiprid, Emamectin benzoate, Isoprocarb, Carbaryl, Parathion-methyl, Lambda-cyhalothrin |
| LOD Range | 0.01–10 ppb (mycotoxins), 0.01–0.1 ppm (pesticides), 0.02–0.1 ppm (heavy metals) |
| Liquid Handling Accuracy | ≤1% CV |
| Automation Scope | Full unattended workflow — sample loading, extraction, dilution, reagent preheating, cartridge preheating, incubation, optical detection, and data upload |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | NJ-IA |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Detection Channels | 20 |
| Measurement Error | < 0.01 Absorbance Units |
| LOD (Dichlorvos) | ≤ 0.2 mg/L |
| Additional LODs | Parathion ≤ 0.8 mg/L, Chlorpyrifos ≤ 0.16 mg/L, Phoxim ≤ 0.2 mg/L, Methamidophos ≤ 1.2 mg/L, Carbaryl ≤ 0.24 mg/L, Malathion ≤ 1.5 mg/L, Carbofuran ≤ 0.04 mg/L, Methomyl ≤ 0.1 mg/L, Isoprocarb ≤ 0.28 mg/L, Omethoate ≤ 0.44 mg/L, Dichlorvos ≤ 0.1 mg/L |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | SKJ-IA |
| Pricing | Upon Request |
| Function Type | Multi-analyte Quantitative Detection Platform |
| Sample Applicability | Universal for Grains, Feed, Fruits, Vegetables, Tea, Dairy Products |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | 15–30 minutes |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 independent optical channels |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SKJ-IA |
| Price Range | USD 7,000 – 14,000 |
| Function Type | Multi-analyte Quantitative Detection |
| Sample Versatility | Universal for Solid & Liquid Food Matrices |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | ≤25 min |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 simultaneous independent channels |
| Detection Range (Cd & Pb) | 0–1 ppm |
| Regulatory Alignment | Designed to support ISO 17025-compliant workflows and GLP-aligned food safety testing |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SKJ-IA-01 |
| Instrument Class | Multi-Mycotoxin Immunoassay Analyzer |
| Detection Principle | Colloidal Gold-Based Lateral Flow Immunoassay (Quantitative) |
| Throughput | 6 samples per run |
| Assay Time per Sample | ≤10 min |
| Display | 7-inch capacitive touchscreen |
| Integrated Thermal Printer | Yes |
| Data Connectivity | Wi-Fi / USB / Optional 4G module |
| Regulatory Validation | Official evaluation reports issued by the State Grain Administration (China) for AFB1, DON, ZEN, and OTA |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | SKJ-IA-03 |
| Price Range | USD 7,000 – 14,000 |
| Detection Principle | Competitive Enzyme-Linked Immunosorbent Assay (ELISA) with Quantitative Lateral Flow Readout |
| Sample Throughput | 6 samples per run |
| Analysis Time | ≤10 minutes per sample |
| Target Analytes | Cd, Pb, Cu, Hg |
| Detection Ranges | Cd: 0–1 ppm |
| Pb | 0–1 ppm |
| Cu | 0–20 ppm |
| Hg | 0–0.3 ppm |
| Sample Types | Raw grains (rice, wheat, corn, barley), milled grain products, animal feed, feed ingredients, botanical herbal materials |
| Display | Color resistive touchscreen (≥7″) |
| Data Output | Onboard thermal printer, GPS-tagged CSV export via Wi-Fi/4G, API-compatible JSON upload to LIMS or cloud platforms |
| Regulatory Alignment | Compliant with GB 5009.15–2014 (Cd), GB 5009.12–2023 (Pb), and aligned with AOAC Official Method 2019.02 for immunoassay-based heavy metal screening in cereals |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SKJ-IA-04 |
| Price Range | USD 7,000 – 14,000 |
| Functionality | Multi-analyte (Cd, Pb, Cu, Cr) |
| Sample Versatility | Universal for solid and liquid food matrices |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | ≤25 minutes |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 parallel optical channels |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SKJ-IA-05 |
| Function Type | Multi-analyte Quantitative Detection |
| Sample Versatility | Universal for Herbal Materials, Decoction Pieces, Animal-derived Herbs |
| Optical Wavelength | 410 nm |
| Detection Time per Sample | ≤25 minutes |
| Repeatability (RSD) | ≤0.2% |
| Detection Channels | 6-channel simultaneous measurement |
| Detection Range | Cd 0.1–5 mg/kg, Pb 0.2–10 mg/kg, Cu 2–50 mg/kg |
| Accuracy | Cd ≥80%, Pb ≥80%, Cu ≥75% |
| Compliance Reference | Chinese Pharmacopoeia (2020 Ed., Vol. IV, General Chapter 0412 & 2341) |