Other Elemental Analyzers
Filter
Showing 1–30 of 73 results
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-6100 |
| Instrument Type | Automated Iodine-Specific Elemental Analyzer for Urine, Water and Salt Matrices |
| Regulatory Context | Designed for compliance with WS/T 107.1–2016 (China), ISO 8468:1996 (Water Quality – Determination of Iodide), and USP <232>/<233> elemental impurities guidance frameworks |
| Cooling Method | Integrated Peltier-based water bath refrigeration |
| Digestion Architecture | Graphite block digestion with reflux condensation |
| Reagent Consumption | Optimized for ≤1.5 mL per sample (standard protocol) |
| Throughput | Up to 48 samples per batch (with optional autosampler) |
| Safety Compliance | Meets GB/T 18204.1–2013 (Public Health Inspection Standards) for laboratory ventilation integration |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5100 |
| Detection Elements | C, N, S, Cl |
| Furnace Configurations | Dual-mode vertical & horizontal combustion furnace |
| Detector Technology | HiPerSens® electrochemical and thermal conductivity detection |
| Sample Forms | Solid, liquid, gaseous & supercritical fluid |
| Automation | Fully automated direct injection |
| Compliance | Designed for GLP/GMP environments |
| Safety Systems | Integrated self-diagnostic module, flame sensor (horizontal mode), aerosol/liquid ingress protection, auto-leak monitoring, active gas stream drying & purification |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | LA-LIBS |
| Pricing | Available Upon Request |
| Brand | Binzhenghong |
|---|---|
| Model | CH-1000ml |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic (China-Made) |
| Capacity | 1000 mL |
| Application | Purification of HNO₃, HCl, HF, NaOH solutions, and organic solvents including N-Methyl-2-pyrrolidone (NMP) |
| Construction Material | PTFE (Teflon)-lined chamber and condenser |
| Operating Principle | Sub-boiling distillation via infrared radiant heating |
| Metal Impurity Reduction | From ~10 ppb to ≤0.01 ppb (single pass) |
| Compliance | Designed for ISO/IEC 17025-compliant trace metal analysis workflows |
| Software Interface | None (standalone analog control) |
| Certifications | CE-marked per EN 61000-6-3 & EN 61000-6-2 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Type | Total Reflection X-ray Fluorescence (TXRF) Spectrometer |
| Model | Blood Heavy Metal Analyzer |
| Element Range | Al (13) to U (92) |
| Detection Limit | 2 pg |
| Sample Volume (Liquid/Suspension) | 1–50 µL |
| Sample Mass (Powder) | <10 µg |
| Detector | 4th-Generation XFlash® SDD Silicon Drift Detector |
| Cooling | Peltier (No Liquid Nitrogen Required) |
| Energy Resolution | <160 eV at Mn Kα (100 kcps) |
| Automation Options | 1-position or 25-position Auto-sampler |
| Compliance | ASTM D7782, ISO 17294-2, USP <232>/<233>, GLP/GMP-ready data integrity features |
| Brand | Cambridge Sensotec |
|---|---|
| Origin | United Kingdom |
| Model | Rapidox 6100 |
| Gas Measurement Range | SF₆ 0–100% (±0.5% FS), H₂O −60 to +20 °C dew point (±2 °C), SO₂ 0–100 ppm (±2%), HF 0–25 ppm (±1 ppm), CF₄ 0–80% (±1%), O₂ 0–100% (±1%) |
| Analysis Time | 3–5 minutes per sample |
| Enclosure | IP66-rated Peli™ carry case |
| Weight | 17 kg |
| Internal Compressor Output | 10 bar |
| Battery Life | Up to 8 hours (Li-ion) |
| Display | 7-inch full-color touchscreen |
| Data Export | USB flash drive (Excel-compatible .csv format) |
| Onboard Thermal Printer | Yes |
| Language Options | Multi-language UI with password-protected access |
| Brand | DAJ |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | WGJ-III |
| Pricing | Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | EasyChem Plus |
| Price | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | RLTD-05 / RLTD-10 |
| Pricing | Available Upon Request |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HELIOS CL |
| Price | Upon Request |
| Measurement Principle | Coulometric Titration (Absolute Method) |
| Sample Types | Liquids (including viscous), Gases (incl. LPG), Solids, Slurries, Polymers, Fuels, Environmental Matrices |
| Compliance | ASTM D4929, ASTM D5808, ASTM D5194, ASTM D6721, GB/T 18612, SH/T 1757, GB/T 23971-B, SH/T 0677-A, UOP 779, ISO 9562, NF EN 12260, NF EN 14077 |
| Detection Range | 0.1 ppm to 80 wt% Cl (matrix-dependent, no dilution required) |
| Electrolyte Options | Three grades for low-, medium-, and high-concentration applications |
| Dual-Cell Architecture | Two independent coulometric titration cells |
| Furnace | F2-type high-temperature combustion furnace, max. 1100 °C |
| Carrier Gases | O₂ (99.998%, 3 bar) and Ar (99.995%, 3 bar) |
| Sample Introduction | 20–80 µL liquid |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 66 × 83 × 56 cm |
| Weight | 32 kg |
| Warranty | 5-year hardware warranty |
| Language Interface | English, French, Spanish, German, Russian, Chinese |
| Safety Features | Automated acid-free dry/wash system, light-shielded semi-pressurized titration cell, integrated gas flow control and pressure monitoring |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAOIL |
| Type | Rotating Disk Electrode Optical Emission Spectrometer (RDE-OES) |
| Detection Principle | Arc Spark Optical Emission Spectrometry |
| Measurement Time | ≤30 s per sample |
| Elements Quantified | Up to 32 metallic elements |
| Detection Limit (LOD) | Sub-ppm for most elements (standard configuration) |
| Sample Types | Lubricants, fuels, coolants, process water, hydraulic fluids |
| Compliance | ASTM D6728, ASTM D6595, NB/SH/T 0865 |
| Integrated System | Built-in 10-inch color touchscreen, embedded industrial PC, automated electrode dresser, and active ventilation unit |
| Dimensions & Portability | Compact benchtop footprint |
| Sample Preparation | None required — direct liquid analysis |
| Gas Requirement | None (no carrier gas, no plasma gas) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FASP-01 |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FASP-ECO |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Output Options | 4 programmable relay outputs (250 V, 4 A), 1 isolated 4–20 mA output (max. 750 Ω), 1 RS485 interface |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min (configurable) or triggered by external/flow signal |
| Rinse Duration | 15–1800 s (user-configurable) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Temp. | 10–40 °C |
| Units Supported | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Measurable Units | °dH, °f, ppm CaCO₃, mmol/L |
| Outputs | 4 programmable relay outputs (max. 250 V, 4 A), 1 × 4–20 mA (max. 750 Ω), 1 × RS485 |
| Inputs | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min, external trigger, or flow-signal synchronized |
| Rinse Duration | Configurable (15–1800 s) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Temp. | 10–40 °C |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Output Options | 4 programmable relay outputs (250 V, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min (configurable) or triggered externally/flow-synchronized |
| Rinse Duration | 15–1800 s (user-configurable) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Range | 10–40 °C |
| Units Supported | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Output Options | 4 programmable relay outputs (250 VAC, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min (configurable) or triggered by external/flow signal |
| Rinse Duration | 15–1800 s (user-configurable) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Range | 10–40 °C |
| Compatible Units | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Aqualysis 800A |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202I |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.0 / 0.1 / 1 ppm (selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS), configurable for measured value or temperature |
| Communication | RS485 Modbus RTU |
| Enclosure Rating | IP67-rated sealed housing |
| Electrode Compatibility | BSens710 (F⁻), BSens720 (Cl⁻), BSens730 (NH₃-N) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PM 8202I |
| Pricing | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 8202I |
| Price | Upon Request |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.0 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (dependent on range) |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Interface Language | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for concentration or temperature) |
| Digital Communication | RS485 Modbus RTU |
| Enclosure Rating | IP66/IP67 (fully sealed, moisture- and gas-resistant) |
| Electrode Compatibility | Bsens710 Fluoride ISE, Bsens720 Chloride ISE, Bsens730 Ammonia ISE |
| Calibration | Manual or scheduled two-point calibration with password-protected access |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202I |
| Price | Upon Request |
| Measurement Range | 0.00–20000 ppm |
| Resolution | 0.0 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm |
| Temperature Compensation | –10 to 130 °C (manual/automatic, NTC30K or PT1000) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | Chinese/English |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% F.S.), RS485 Modbus RTU |
| Enclosure Rating | IP66/IP67 (fully sealed, waterproof & gas-tight) |
| Electrode Compatibility | Bsens710 (F⁻), Bsens720 (Cl⁻), Bsens730 (NH₃-N) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON3000 |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON5000 |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON5000 |
| Price | Upon Request |
| Brand | Hongweiliangzi |
|---|---|
| Origin | Shandong, China |
| Model | HW-DYS2 |
| Measurement Channels | 6 |
| Sample Throughput | 20 consecutive samples |
| Analysis Time per Sample (8 elements) | ≤5 min |
| Stability | ±1 digit within 5 min |
| Compliance Standards | GB/T 4734, GB/T 6900, QB/T 2578–2002 |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤85% |
| Power Supply | 220 V, 50/60 Hz |
| Power Consumption | 1 kW |
| Dimensions (Instrument) | 500 × 460 × 350 mm |
| Weight (Instrument + Packaging) | 15 kg |
| Brand | HORIBA |
|---|---|
| Origin | Imported |
| Manufacturer | HORIBA, Ltd. |
| Model | EMGA-Expert |
| Detection Principle | Pulse Heating Extraction + NDIR (CO/CO₂, H₂O) & TCD (N₂) |
| Gas Detection Methods | Non-Dispersive Infrared (NDIR) for O and H |
| Automation Options | Auto-Sampler, Auto-Crucible Loader, Auto-Electrode Cleaner, Halogen Trap |
| Compliance Support | ASTM E1019, ISO 14284, ISO 22356, JIS G 1257, USP <233>, FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready software architecture |
| Brand | Kaufman & Robinson, Inc. (KRI) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KRI Ion Beam Source Series |
| Pricing | Upon Request |
