| Brand | BBE/bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | A-ToxII |
| Instrument Type | Online |
| Test Organism | Algae (Chlorella vulgaris, ISO 8692:2012 compliant) |
| Operating Temperature | 0–35 °C |
| Reagent Storage Temperature | 0–30 °C |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Country of Origin | Imported |
| Model | DFP |
| Portability | Portable |
| Target Organism | Cyanobacteria (Phytoplankton) |
| Operating Temperature Range | −2 °C to 40 °C |
| Reagent Storage Temperature | −2 °C to 40 °C |
| Measurement Cycle Time | 7 hours |
| Depth Range | 0–100 m |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Product Type | Online Water Toxicity Analyzer |
| Model | Fish Toximeter II |
| Operating Temperature Range | 5–28 °C |
| Test Organism | Zebrafish (Danio rerio) |
| Detection Principle | Real-time Video-Based Behavioral Analysis |
| Compliance Basis | Extended Dynamic Daphnia Test (EDDT)-aligned methodology, aligned with ISO 10706:2000 (Water quality — Guidance on toxicity testing using fish), EU WFD (Water Framework Directive) monitoring principles |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Type | Laboratory Instrument |
| Model | PhycoLA |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Sample Volume per Batch | 25 mL |
| Biological Target | Cyanobacteria and Algal Taxa |
| Application Domain | Freshwater and Brackish Water Quality Monitoring |
| Brand | bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | bbe Moldaenke GmbH |
| Country of Origin | Imported |
| Model | PS |
| Instrument Type | Online |
| Biological Target | Algae |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Sample Volume per Cycle | 45 mL |
| Origin | Hebei, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | BHP9514 |
| Price | Upon Request |
| Sample Positions | 18 |
| Minimum Detection Time | 5 min |
| Detector Core | Photomultiplier Tube (PMT) |
| Spectral Detection Range | 300–650 nm |
| Display | LCD Touchscreen |
| Data Output | Built-in Micro Printer & PC Interface |
| Environmental Operating Range | 5–40 °C, 10–90% RH (at 25 °C) |
| Toxicity Indicator | LED Status Lights (Pass/Fail) |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Daphnia Toximeter II |
| Instrument Type | Online Toxicity Monitor |
| Test Organism | Daphnia magna (water flea) |
| Operating Temperature Range | 0–35 °C |
| Reagent Storage Temperature | 0–30 °C |
| Brand | Dr-Water |
|---|---|
| Origin | Hunan, China |
| Model | Dr-W960 |
| Instrument Type | Portable |
| Biological Indicator | Bioluminescent Bacteria (Aliivibrio fischeri, Vibrio qinghaiensis, Photobacterium phosphoreum) |
| Operating Temperature | 10–40 °C (ambient) |
| Detection Time | ≤15 min post-sample preparation |
| Light Detection Range | 300–1100 nm |
| Photodetector | Silicon Photomultiplier (SiPM) |
| Display | 5″ IPS Capacitive Touchscreen (1024×768) |
| Power Supply | Rechargeable Li-ion Battery + AC Adapter |
| Data Connectivity | USB-C, Wi-Fi, Bluetooth 5.0, 4G LTE |
| Data Storage | ≥10 million test records |
| Compliance | ISO 11348-3, GB/T 15441-1995 |
| Toxicity Quantification | Relative Luminescence Inhibition (%) → Converted to Equivalent Toxic Unit (TU) or Reference Toxicant (e.g., ZnSO₄·7H₂O mg/L) |
| Accuracy | ±1% RSD (n=3, vs. certified reference standard) |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | ET1500 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Biological Indicator | *Aliivibrio fischeri* (lyophilized bioluminescent bacteria) |
| Operating Temperature Range | 15–40 °C |
| Reagent Storage Temperature | 2–8 °C (reconstituted), –20 °C (lyophilized long-term) |
| Coefficient of Variation (CV) | ≤1% (intra-assay, n=10 at IC₅₀ concentration) |
| Batch Capacity | 4 assay groups × 17 samples per group |
| Exposure Time | 0–99 s (programmable in 1-s increments) |
| Detection System | Photomultiplier Tube (PMT) |
| Spectral Response | 300–650 nm (peak sensitivity at 400 nm) |
| Light Measurement Range | 0–1,000,000 RLU (Relative Light Units) |
| Sample Vessel | 12 mm diameter × 55 mm height glass or polystyrene test tube |
| Data Storage | 1900 measurement records with timestamp, sample ID, and exposure time |
| Interface | RS-232C serial port for PC connectivity and data export |
| Display | Backlit LCD (128 × 64 pixels) |
| Power Supply | 4 × AA alkaline or Ni-MH rechargeable batteries (≥2600 mAh capacity) or external AC adapter (220 V ±10%, 50 Hz) |
| Dimensions (L×W×H) | 320 × 170 × 180 mm |
| Weight | 2.0 kg |
| Environmental Operating Conditions | 10–90% RH (non-condensing) |
| Brand | Fitlylab |
|---|---|
| Origin | Shenzhen, China |
| Model | QTOX-60 |
| Instrument Type | Portable |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Repeatability | ≤5% CV |
| Assay Duration | 5, 15, or 30 minutes |
| Detection Range | −120% to +100% inhibition |
| Blank Water Inhibition | ≤±5% |
| Data Storage | 2000 test records via USB |
| Display | Color LCD screen |
| Power Supply | Internal rechargeable Li-ion battery (≥10 h standby), AC adapter, and external power bank compatible |
| Weight | <480 g |
| Accessories | 10 disposable assay tubes, 2 calibrated pipettes, tube rack, standard reagent kit (lyophilized *A. fischeri*, reconstitution buffer, control solution), rugged carrying case |
| Brand | FPI |
|---|---|
| Origin | Italy |
| Manufacturer | FPI |
| Type | Portable |
| Model | Micromac SmarTox |
| Operating Temperature | 4–6 °C (bacterial storage), 15 °C and 25 °C (reaction chambers) |
| Assay Time | 15 min |
| Compliance | ISO 11348-3, GB/T 15441 |
| Detection Principle | Bioluminescence inhibition of non-pathogenic marine bacteria |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Hangzhou) Co., Ltd. |
| Model | TOX-2000 |
| Dimensions | 0.60 m × 0.55 m × 1.00 m (L×W×H) |
| Weight | 60 kg |
| Power Supply | 220 V ±10%, 50 Hz ±1% |
| Operating Temperature | 10–30 °C ambient |
| Water Temperature | 0–40 °C (non-freezing) |
| Response Time | <5 min |
| Detectable Toxic Substances | >5,000 compounds including heavy metals, pesticides, herbicides, biocides, and industrial chemicals |
| Sensitivity (EC₅₀) | HgCl₂ < 0.2 mg/L |
| Repeatability | RSD < 5% |
| Bacterial Cartridge Lifespan | 30 days |
| Data Logging Interval | Configurable down to 1 s |
| Output Signals | 4–20 mA analog |
| Toxicity Classification Levels | 5-tier scale (Low, Moderate, High, Severe, Extreme) |
| Compliance | ISO 11348-3 (Vibrio fischeri luminescence inhibition test) |
| Brand | Guo Ruili Heng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GR5050 |
| Instrument Type | Portable |
| Biological Indicator | Bioluminescent Bacteria (Aliivibrio fischeri) |
| Storage Temperature Range | −10 °C to 50 °C |
| Operational Reagent Temperature Range | 5 °C to 45 °C |
| Time-to-Result | ≤15 minutes post sample preparation |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Eclox |
| Instrument Type | Portable |
| Biological Indicator | *Aliivibrio fischeri* (freeze-dried, ISO 11348-compliant) |
| Operating Temperature Range | −20 °C to +55 °C |
| IP Rating | IP67 |
| Weight | 1.4 kg (instrument only, with batteries) |
| Dimensions | 230 × 77 × 125 mm (instrument) |
| Power Supply | 4 × AA alkaline batteries (≥250 tests per set) |
| Display | Backlit graphical LCD |
| Data Storage | 32 KB non-volatile memory |
| Interface | RS232 serial output |
| Measurement Time | Default 15 s (configurable: 6–20 s) |
| Toxicity Screening Range | 0–100% inhibition (linear response: 10–90%) |
| Screening Assay Duration | 5, 15, or 30 min |
| Certification | CE Marked |
| Bacterial Reagent Storage | −18 °C (12 months) |
| Reagent Shelf Life | Chemical luminescence reagents — 24 months at room temperature |
| Additional Onboard Parameters | Residual chlorine, total chlorine, arsenic (colorimetric), pH, conductivity (TDS), platinum-cobalt color, organophosphate nerve agents, carbamate insecticides |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | LUMIStox300 |
| Instrument Type | Portable |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Compliance | ISO 11348-3 (Water quality — Determination of the inhibitory effect of water samples on the light emission of *Vibrio fischeri* — Part 3: Method using freeze-dried bacteria) |
| Power Supply | 48 VA (230 V ±10%, 50 Hz) |
| Operating Environment | 16–29 °C, <80% RH, non-condensing |
| Weight | 7.75 kg |
| Optical Compensation | Automatic chromaticity and turbidity correction |
| Measurement Mode | Acute and chronic toxicity assessment via bioluminescence inhibition kinetics |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | TX1315 |
| Instrument Type | Field-Portable |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | +5 °C to +45 °C |
| Storage Temperature Range | −10 °C to +50 °C |
| Reagent Temperature Range | +5 °C to +45 °C |
| Batch Capacity | Up to 50 sequential tests per reagent kit (wastewater matrix) |
| Detection Time | <15 minutes for luminescence-based toxicity assay |
| Measurement Principle | Bioluminescence inhibition assay (ISO 11348-3 compliant) and ATP bioluminescence quantification (ISO 22192 & EPA 1605B aligned) |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP9510 |
| Type | Portable ATP Analyzer |
| Detection Principle | Firefly Luciferase–Based Bioluminescence Assay |
| Biological Agent | *Photobacterium phosphoreum* or *Aliivibrio fischeri* (freeze-dried luminescent bacteria, optionally firefly luciferase reagent system) |
| Spectral Detection Range | 320–1000 nm |
| Background Count Rate | 0 cps |
| Measurement Range | 0–65535 RLU (Relative Light Units) |
| Detection Time | 5–300 s (user-adjustable) |
| Sensitivity | ≤1 × 10⁻¹⁵ mol ATP |
| Data Storage | ≥1000 test records + 100 configurable upper/lower alarm thresholds |
| Display & Output | RLU only (no concentration conversion built-in |
| Power Supply | Two AA alkaline or rechargeable batteries |
| Battery Life | ≥8 h continuous operation |
| Weight | 258 g (including batteries) |
| Dimensions | 202 × 78 × 30 mm |
| Interface | USB 2.0 (for data export and firmware update) |
| Operating Environment | 5–40 °C, 10–90% RH (non-condensing) |
| Sample Interface | Integrated sterile swab with pre-moistened buffer (single-use, CE-marked for hygiene applications) |
| Compliance | Designed to support ISO 22000, HACCP, and FDA Food Code Chapter 4 verification protocols |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP9511 |
| Detection Principle | Bioluminescent Bacteria Assay |
| Sample Capacity | 18 positions |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Response Range | 300–650 nm |
| Operating Temperature | 5–40 °C |
| Display | Integrated LCD Touchscreen |
| Data Output | Built-in thermal printer, USB data export, PC connectivity |
| Onboard Data Storage | Yes |
| Software Interface | Windows-compatible analysis software with statistical tools |
| Compliance Context | Designed for GLP-compliant workflows |
| Brand | Hamamatsu Photonics / BHP |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | BHP9514 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Sample Capacity | 18 positions |
| Minimum Assay Time | 5 min |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Response Range | 300–650 nm |
| Display | Integrated LCD touchscreen interface |
| Data Output | Built-in thermal printer |
| Connectivity | USB and RS-232 for PC integration |
| Environmental Operating Range | 5–40 °C, 10–90% RH (non-condensing) |
| Compliance | Designed to support ISO 11348-3 and ASTM D5660-22 protocols |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP9515 |
| Type | Portable Toxicity Analyzer |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–90% RH (at 25 °C) |
| Minimum Assay Time | 5 min |
| Continuous Operation | ≥8 h on battery |
| Data Storage Capacity | 1,000 measurements per mode (ISO / Basic / RLU) |
| Detection Wavelength Range | 320–1000 nm |
| Luminescence Measurement Range | 0–65,535 RLU (Relative Light Units) |
| Instrument Weight | 258 g (including batteries) |
| Dimensions | 202 × 78 × 30 mm |
| Power Supply | 3 V DC (AA alkaline battery pack) |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP9515 |
| Type | Portable bioluminescence-based toxicity analyzer |
| Biological indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Detection principle | Inhibition of bacterial bioluminescence |
| Fastest assay time | 5 min |
| Continuous operation | ≥8 h on battery |
| Data storage | 1000 measurements per mode (3 modes total) |
| Spectral response range | 320–1000 nm |
| Measurement range | 0–65535 RLU (Relative Light Units) |
| Instrument weight | ~258 g (including batteries) |
| Dimensions | 202 × 78 × 30 mm |
| Power supply | 3 V DC (AA alkaline batteries) |
| Operating temperature | 5–40 °C |
| Operating humidity | 10–90% RH (at 25 °C) |
| Compliance | Designed for field-deployable GLP-aligned environmental screening |
| Software interface | USB data export, optional PC software for trend analysis and report generation |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-6200 |
| Instrument Type | Portable |
| Biological Indicator | Bioluminescent Bacteria (Aliivibrio fischeri) |
| Detection Time | ≤15 min |
| Display | 7-inch Color TFT Touchscreen |
| Power Supply | Rechargeable Lithium Battery (8 h Continuous Operation) |
| Sample Chamber | Motorized Auto-Lift Design |
| Data Storage Capacity | ≥80,000 Test Records |
| Communication Interfaces | USB 2.0, Bluetooth 5.0, Wi-Fi 802.11 b/g/n, 4G LTE, RS-232, RJ45 Ethernet |
| Compliance Standards | GB/T 15441–1995, ISO 11348-3:2007 |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LJ-DX |
| Instrument Type | Portable |
| Test Organism | Bioluminescent Bacteria (e.g., *Vibrio fischeri*, *Photobacterium phosphoreum*, *Aliivibrio qinghaiensis*) |
| Operating Temperature | +5°C to +45°C |
| Reagent Storage Temperature | −10°C to +50°C |
| Repeatability | Relative standard deviation <1% across three replicate measurements per sample |
| Assay Time | ≤15 minutes post-sample preparation |
| Spectral Response Range | 300–1100 nm |
| Detection Principle | Bioluminescence Inhibition Assay |
| Compliance | GB/T 15441–1995, ISO 11348-3 |
| Power Supply | AC 220 V / DC 12 V dual-mode |
| Battery | 6000 mAh Li-ion, >8 h continuous operation |
| Dimensions | 420 × 330 × 175 mm |
| Weight | 5 kg |
| Data Storage Capacity | ≥80,000 records |
| Connectivity | RJ45, Wi-Fi, 4G, Bluetooth, USB |
| Display | 7-inch capacitive touchscreen |
| Detector | Silicon Photomultiplier (SiPM) |
| Brand | LAR |
|---|---|
| Origin | Germany |
| Model | ToxAlarm |
| Instrument Type | Online Water Toxicity Analyzer |
| Biological Agent | Nitrifying Bacteria |
| Measurement Principle | Oxygen Consumption Rate (Respirometry) |
| Toxicity Range | 0–100% |
| Response Time | <5 minutes |
| Sample Preparation Time | 5–10 min |
| Enclosure Rating | IP54 |
| Dimensions (W×H×D) | 870 × 600 × 560 mm |
| Weight | ~70 kg |
| Power Supply | 230/115 V~, 50/60 Hz, 100 VA |
| Inlet/Outlet Tubing | 20 mm ID (6 × 1 mm & 4 × 1 mm auxiliary lines) |
| Analog Output | 0/4–20 mA |
| Serial Interface | RS232 + USB |
| Remote Access | TCP/IP (Ethernet) |
| Display | High-resolution backlit LCD touchscreen |
| Compliance | Designed for continuous operation in drinking water and surface water monitoring per DIN EN ISO 11348 and ASTM D5905 respirometric toxicity testing principles |
| Brand | Lihero |
|---|---|
| Model | LFTOX-B2010 |
| Type | Portable Toxicity Analyzer |
| Measurement Principle | Bioluminescent Bacterial Assay (ISO 11348-3) |
| Microorganism | Freeze-dried *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Reconstitution Time | <5 min |
| Shelf Life (lyophilized) | ≥6 months at ≤−20 °C |
| Working Stability (reconstituted) | 7–10 days at 2–8 °C |
| Detection Range | EC50 from 0.1% to 100% sample dilution (equivalent to broad-spectrum toxicity index) |
| Compliance | ISO 11348-3:2022, DIN 38412-30, EPA 600/R-95/125 |
| Brand | Lihero |
|---|---|
| Model | LFTOX-Z2010 |
| Type | Online Toxicity Analyzer |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*), *Vibrio qinghaiensis*, or *Photobacterium phosphoreum* |
| Measurement Principle | Bioluminescence Inhibition Assay |
| Detection Mode | Automatic Sampling → Cell Exposure → Luminescence Quantification → Toxicity Calculation |
| Test Modes | Positive Control / Negative Control / Sample Testing |
| Operational Temperature Range | 15–25 °C (ambient-controlled chamber) |
| Reagent Stability | Lyophilized bacteria stable at ≤−20 °C for ≥6 months |
| Response Time | <15 min (typical EC50 determination) |
| Toxicant Coverage | Broad-spectrum response to >5,000 organic and inorganic toxicants including heavy metals, pesticides, phenols, PAHs, and endocrine disruptors |
| Compliance | Designed to support ISO 11348-3, ASTM D5660, and DIN 38412-L34 protocols |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | BioFix Lumi-10 |
| Instrument Type | Laboratory |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Operating Temperature | 18–25 °C |
| Reagent Storage & Assay Temperature | 20–25 °C |
| Coefficient of Variation (CV) | ≤5% (RSD) |
| Batch Capacity | 10 samples per run |
| Assay Duration | 30 minutes per batch |
| Detection Principle | Bioluminescence Inhibition/Enhancement |
| Photomultiplier Detector | Ultrafast Single-Photon Counter |
| Wavelength Range | 380–630 nm |
| Light Intensity Range | 0–120,000,000 photons/s |
| Detection Limit | 1 RLU |
| Display | Backlit monochrome LCD (128 × 64 pixels) |
| Data Storage | 2000 test records |
| Environmental Operating Range | 15–30 °C, 10–90% RH (non-condensing) |
| Power Supply | Rechargeable battery or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including battery) |
| Compliance | EN ISO 11348-1/2/3, CE marked per 2006/95/EC (LVD) and 2004/108/EC (EMC) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | Lumi-10 |
| Detector | Ultra-high-speed single-photon-counting photomultiplier tube (PMT) |
| Wavelength Range | 380–630 nm |
| Display | LED, 128 × 64 pixels |
| Data Storage Capacity | 2,000 measurements |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 10–90 % RH (non-condensing) |
| Power Supply | 3 × rechargeable Ni-Cd batteries or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including batteries) |
| Dynamic Range | >6 decades |
| Interface | RS-232 serial port |
| Preloaded Assay Templates | 6 |
| Language Options | English and German |
| Security | Password-protected user access |
| Compliance | EN ISO 11348-3, Directive 73/23/EEC (Low Voltage), Directive 89/336/EEC (EMC, incl. 92/31/EEC amendment) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | BioFix® Lumi-10 |
| Instrument Type | Portable |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 15–30 °C (recommended), functional range: 0–40 °C |
| Reagent Storage & Use Temperature | 0–40 °C |
| Coefficient of Variation (CV) | <10% |
| Photon Detection Speed | 5,000 photons per 0.1 s |
| Assay Duration | Default 10 s (adjustable from 0.5–20 s) |
| Detector | Fast single-photon-counting photomultiplier tube (PMT) |
| Wavelength Sensitivity | 380–630 nm |
| Display | LED, 128 × 64 pixels |
| Data Storage Capacity | 2,000 measurement records |
| Power Supply | 3× rechargeable Ni-Cd batteries or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including batteries) |
| Compliance | Low Voltage Directive 73/23/EEC, EMC Directive 89/336/EEC (incl. amendment 92/31/EEC) |
| Brand | microLAN |
|---|---|
| Origin | Netherlands |
| Model | iTOXcontrol |
| Instrument Type | Online |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Operating Temperature | 5–40 °C |
| Reagent Temperature Range | 15–30 °C |
| Repeatability | Relative Error ≤5% |
| Sample Throughput | 10 mL/h (4.5 mL per test, 2 tests/h) |
| Measurement Duration | 40 min |
| Enclosure Rating | IP31 |
| Power Supply | 220 VAC, 50 Hz or 110 VAC, 60 Hz |
| Dimensions (D×W×H) | 50×50×110 cm (plus 73 cm with trolley) |
| Weight | 90 kg (excl. optional air conditioning unit: +20 kg) |