Flow Cytometer
Filter
Showing 1–30 of 88 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | NovoCyte Advanteon |
| Pricing | Upon Request |
| Technology Platform | Spectral Flow Cytometry |
| Instrument Type | Flow Cytometry Analyzer |
| Intended Use | Research-Only |
| Detection Channels | 19 (expandable to 21 fluorescence parameters) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | NovoCyte |
| Pricing | Upon Request |
| Technology Platform | Spectral Flow Cytometry |
| Instrument Type | Benchtop Flow Cytometer for Cell Analysis |
| Intended Use | Research-Only |
| Laser Configuration | 1–3 Solid-State Lasers |
| Detection Channels | 17-parameter Fluorescence Detection |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | NovoCyte Opteon |
| Pricing | Upon Request |
| Technology Platform | Spectral Flow Cytometry |
| Instrument Type | Flow Cytometer |
| Primary Use Case | Research |
| Laser Configuration | 3–5 Lasers (UV, Violet, Blue, Yellow, Red) |
| Automated Sample Loading | Yes |
| Detector Count | 73 |
| Validated Panel Capacity | Up to 45-color |
| Forward/Side Scatter Optimization | Dual-angle (405 nm & 488 nm SSC), enabling sub-80 nm particle resolution |
| Software Platform | NovoExpress v4.0+ with real-time acquisition, spectral unmixing, and GLP-compliant audit trail |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | NovoCyte Penteon |
| Product Category | Flow Cytometry Analyzer |
| Intended Use | Research-Only |
| Lasers | UV (355 nm), Violet (405 nm), Blue (488 nm), Yellow (561 nm), Red (640 nm) |
| Automated Sample Loading | Yes (integrated Agilent NovoSampler Q) |
| Fluorescence Detection Channels | 30 |
| Detector Technology | Silicon Photomultiplier (SiPM) |
| Scatter Resolution Limit | ≥0.1 µm particles |
| Software Platform | Agilent NovoExpress v4.x |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | NovoCyte Quanteon |
| Pricing | Available upon request |
| Technology Platform | Analytical Flow Cytometry |
| Product Category | Flow Cytometer for Cell Analysis |
| Intended Use | Research-only (Not for Diagnostic Use) |
| Lasers | 4 |
| Fluorescence Detection Channels | 25 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Seahorse XF Pro Consumables |
| Product Type | Cell Metabolic Analysis System Consumables |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | XFp Consumables |
| Product Category | Cell Analysis Systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | Seahorse XFp |
| Pricing | Upon Request |
| Brand | Amnis |
|---|---|
| Origin | USA |
| Manufacturer | Luminex Corporation (acquired Amnis) |
| Product Type | Imaging Flow Cytometer |
| Model | ImageStreamX Mark II |
| Laser Configuration | Up to 7 lasers (standard: 488 nm, 642 nm, 785 nm |
| optional | 375 nm, 405 nm, 561 nm, 592 nm) |
| Detection Channels | Standard: 6 channels (1 brightfield, 1 darkfield, up to 4 fluorescence) |
| Objective Lenses | Standard 40× |
| Fluorescence Sensitivity | <5 MESF (Molecules of Equivalent Soluble Fluorochrome) |
| Imaging Rate | >1,000 cells/sec |
| Images per Cell | Up to 12 simultaneous high-resolution digital images (including BF, DF, and multiple fluorescence channels) |
| Pixel Resolution | 656 × 494 pixels per image |
| Field of View | ~100 µm × 75 µm per image |
| Sample Volume Range | 20–200 µL per acquisition |
| Brand | Invitrogen |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | Attune Xenith |
| Technology Platform | Spectral Flow Cytometry |
| Product Category | Flow Cytometer |
| Primary Use Case | Research Applications |
| Lasers | 6 lasers (405 nm, 488 nm, 561 nm, 594 nm, 640 nm, 785 nm) |
| Detection Parameters | 57 parameters (51 fluorescence channels + 6 scatter channels) |
| Coefficient of Variation (CV) | <3% |
| Fluorescence Sensitivity | FITC ≤ 30 MESF, PE ≤ 10 MESF, APC ≤ 10 MESF |
| Acquisition Rate | >50,000 events/sec |
| Autosampler Compatibility | Yes, compatible with CytKick Max automated sample loader |
| Sample Flow Rate | 12.5–1000 µL/min |
| Compensation Method | Real-time spectral unmixing (automated and manual) |
| Voltage Adjustment Required | Yes |
| Brand | BD |
|---|---|
| Origin | USA |
| Manufacturer | BD Biosciences |
| Product Type | High-Performance Flow Cytometry Cell Sorter |
| Laser Configuration | Up to 6 Lasers (e.g., 355, 405, 445, 488, 561, 640 nm) |
| Fluorescence Detection Channels | Up to 20 parameters / 18 colors |
| Flow Cell | Patented Quartz Cuvette with Optical Adhesive Coupling |
| Aerosol Management | Integrated AMS (Aerosol Management System) + Class II Type A2 Biological Safety Cabinet (optional, NSF/EN/AS certified) |
| Sample Input | 1.0–15 mL tubes with 35 µm or 50 µm inline filters |
| Nozzle Options | 70, 85, 100, 130 µm |
| Drop Delay Calibration | BD AccuDrop™ automated technology |
| Software Platform | BD FACSDiva™ v8.0+ (21 CFR Part 11 compliant audit trail, CS&T, Levey-Jennings QC tracking) |
| Throughput | Up to 70,000 events/sec with linear data acquisition |
| Sensitivity | Detects submicron particles (0.3–1.0 µm) with high signal-to-noise ratio |
| Regulatory Compliance | ISO 13485, FDA 21 CFR Part 11 (software), GLP/GMP-ready workflows |
| Brand | BD |
|---|---|
| Origin | USA |
| Manufacturer | BD Biosciences |
| Product Type | High-Performance Fluorescence-Activated Cell Sorter (FACS) |
| Laser Configuration | Up to 5 Lasers (355, 405, 488, 561, 633 nm) |
| Optical Detectors | 20 PMTs |
| Simultaneous Parameters | 18-color fluorescence + 2 scatter channels |
| Nozzle Options | 70, 85, 100, 130 µm |
| Fluidic Drive | Positive-pressure air-driven sheath system |
| Sterility Support | Integrated aerosol containment, automated sterile setup & wash protocols |
| Software Platform | BD FACSDiva™ v8.0+ with CS&T, AccuDrop™, and Sweet Spot™ technologies |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | BD |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | BD FACSDiscover™ S8 |
| Product Type | High-Parameter Imaging Flow Cytometer with Cell Sorting |
| Application Domain | Clinical Diagnostics, Translational Research, and GMP-Compliant Cell Therapy Development |
| Regulatory Compliance | FDA 510(k)-cleared, CE-IVD marked, compliant with ISO 13485 quality management system requirements |
| Software Validation | Supports 21 CFR Part 11-compliant audit trails, electronic signatures, and data integrity controls |
| Brand | BD |
|---|---|
| Origin | USA |
| Manufacturer | Becton, Dickinson and Company |
| Product Type | High-Performance Benchtop Flow Cytometry Cell Sorter |
| Model | BD FACSMelody™ |
| Compliance | FDA-cleared for in vitro diagnostic use (IVD), CE-IVD marked |
| Optical Configuration | 3-laser (405 nm, 488 nm, 640 nm), up to 10-color detection |
| Sorting Throughput | Up to 20,000 events/sec with >95% purity and >85% recovery |
| Fluidics | Fixed optical alignment, quartz cuvette-based flow cell, acoustic-assisted droplet generation |
| Software Platform | BD FACSChorus™ v3.0 (FDA 21 CFR Part 11 compliant with audit trail, electronic signature, and role-based access control) |
| Regulatory Support | Validated for GLP/GMP environments |
| Service & Support | Global field service network with 24/7 remote diagnostics and on-site engineer dispatch <4 business hours |
| Brand | BD |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | BD FACSymphony™ A1 |
| Product Type | Flow Cytometry Analyzer |
| Software Platform | BD FACSDiva™ and FlowJo™ Compatible |
| Maximum Parameter Capacity | 19 parameters (16-color immunophenotyping) |
| Small Particle Detection Option | BD SP SSC Detector (resolves particles down to 90 nm) |
| Laser Configuration | High-power, energy-focused laser spots with low-noise electronics |
| Fluorochrome Compatibility | BD Horizon™ dyes and broad third-party fluorophores |
| Brand | BD |
|---|---|
| Origin | USA |
| Manufacturer | BD Biosciences |
| Type | Spectral and Conventional Flow Cytometer |
| Model | BD FACSymphony™ A5 SE |
| Product Category | Flow Cytometry Analyzer |
| Regulatory Status | CE-IVD, FDA 510(k) cleared |
| Brand | BD |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | BD FACSymphony™ |
| Pricing | Upon Request |
| Instrument Type | High-Parameter Flow Cytometer |
| Brand | BD |
|---|---|
| Origin | USA |
| Manufacturer | BD Biosciences |
| Category | Imported Instrument |
| Model | BD FACSymphony™ S6 |
| Pricing | Upon Request |
| Brand | BD |
|---|---|
| Origin | USA |
| Manufacturer | BD Biosciences |
| Product Type | Analytical Flow Cytometer |
| Laser Configuration | Up to 5 lasers (355 nm UV, 405 nm violet, 488 nm blue, 561 nm yellow-green, 640 nm red) |
| Detection Parameters | Up to 20 parameters simultaneously |
| Optical Architecture | Patented octagonal–triangular fluorescence collection system with quartz flow cell and optical coupling |
| Software Platform | BD FACSDiva™ v8.0+ with automated acquisition, compensation, and batch analysis |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Optional Accessories | BD HTS Sampler (96-/384-well plate auto-loader), BD FACSFlow™ Supply System (dual 20 L Cubitainers®), forward-scatter PMT upgrade |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Analytical Flow Cytometer |
| Configuration Options | Up to 3 Lasers / 13 Colors (CytoFLEX) |
| Fluorescence Sensitivity | FITC < 30 MESF, PE < 10 MESF |
| Small Particle Detection Limit | ≥80 nm (via VSSC) |
| Optical Architecture | Wavelength-Division Multiplexing (WDM) Detection |
| Regulatory Compliance | FDA 21 CFR Part 11–Ready |
| Software Interface | Dual-language (English/Chinese), Graphical User Interface (GUI) |
| Sorting Capability | Optional Sort Module Available |
| Intended Use | Research-Only |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | CytoFLEX Flow Cytometer |
| Technical Approach | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Application | Research Use Only (RUO) |
| Laser Configuration | Up to 3 Lasers (405 nm, 488 nm, 638 nm) |
| Detection Channels | 13–15 parameters (configurable) |
| Optical Resolution | Full-channel rCV < 3% |
| Sample Flow Rate | Fixed at 10, 30, or 60 µL/min |
| user-definable range | 10–240 µL/min |
| Fluorescence Sensitivity | FITC < 30 MESF |
| Event Acquisition Rate | 30,000 events/sec |
| Automated Sample Loading | Yes |
| Compensation | Fully automated digital compensation |
| Voltage Adjustment | Not required (fixed-optics architecture) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CytoFLEX |
| Product Type | Flow Cytometry Analyzer |
| Lasers | 13 (configurable up to 4 lasers standard, expandable to 3-laser/13-color) |
| Coefficient of Variation (CV) | <3% |
| Flow Rate Range | 10–240 µL/min (preset modes: Low: 10 µL/min, Medium: 30 µL/min, High: 60 µL/min) |
| Fluorescence Detection Sensitivity | ≤30 MESF (FITC), ≤10 MESF (PE) |
| Maximum Event Rate | 30,000 events/sec |
| Dynamic Range | 7 decades |
| Particle Detection Limit | ≥200 nm |
| Optical Architecture | Integrated flow cell & optical module with automatic alignment |
| Software | CytExpert (free, included) |
| Intended Use | Research Use Only (RUO), not for clinical diagnostic applications |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | CytoFLEX LX |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Primary Use Case | Research |
| Lasers | All channels support A (Area), H (Height), fixed W (Width), Time parameter, and absolute event count |
| Detection Channels | Full-channel rCV < 3% |
| Flow Rate | 10–240 µL/min |
| Fluorescence Sensitivity | ≤30,000 events per second (EPS) at 15-parameter acquisition |
| Cell Analysis Throughput | FITC < 30 MESF |
| Automated Sample Loading System | Yes |
| Acquisition Speed | Up to 30,000 events/second |
| Compensation Method | Fully automated, real-time digital compensation |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CytoFLEX mosaic |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Spectral Flow Cytometer |
| Application Domain | Research |
| Lasers | 4–6 |
| Detection Channels | 63–88 |
| Optical Resolution | 80 nm |
| Fluorescence Sensitivity | FITC < 30 MESF, PE < 10 MESF |
| Acquisition Rate | 30,000 events/sec |
| Automated Sample Loading | Yes |
| Sample Flow Rate | 10–240 µL/min |
| Compensation Method | Real-time Automatic Compensation & On-the-fly Spectral Unmixing |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | CytoFLEX Mosaic |
| Technology Pathway | Spectral Flow Cytometry |
| Product Type | Spectral Flow Cytometer |
| Primary Use Case | Research |
| Detection Channels | 88 |
| Automated Sample Loading | Yes |
| Sorting Capability | Optional |
| Autofluorescence Compensation Channels | Up to 10 |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Model | CytoFLEX o |
| Technology Platform | Nanoscale Flow Cytometry |
| Product Category | Flow Cytometer |
| Primary Use Case | Research |
| Lasers | 405 nm, 488 nm, 561 nm, 638 nm |
| Fluorescence Detection Channels | 6 |
| Coefficient of Variation (rCV) | <10% |
| Fluorescence Sensitivity (8-peak calibration beads) | V447: 8 peaks |
| 8531 | 8 peaks |
| Y595 | 8 peaks |
| R670 | 6 peaks |
| R710 | 5 peaks |
| R792 | 4 peaks |
| Sample Acquisition Rate | 16,000 events/sec |
| Automated Sample Loading | Yes |
| Sample Flow Rate | 6 µL/min |
| Compensation Method | Automatic |
| Brand | Beckman Coulter |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | CytoFLEX o |
| Technology Platform | Nanoscale Flow Cytometry |
| Instrument Type | Flow Cytometer |
| Primary Use Case | Research |
| Lasers | 405 nm, 488 nm, 561 nm, 638 nm |
| Fluorescence Detection Channels | 6 |
| Side Scatter (SSC) Detection Channels | 5 |
| Particle Size Detection Range | 40 nm – 1 µm |
| Automated Sample Loading | Yes |
| Compensation Method | Fully Automated |
| Sorting Capability | Optional |
| Sorting Output Ports | 6-way |
| Voltage Adjustment Required | No |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CytoFLEX S Series |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Primary Use Case | Research |
| Laser Configuration | Up to four spatially separated lasers (375 nm, 405 nm, 488 nm, 561 nm) |
| Fluorescence Detection Channels | Up to 13 parameters with full-channel rCV < 3% |
| Optical Resolution | Side Scatter (488 nm) < 300 nm, Violet Side Scatter (405 nm) < 80 nm (vs. polystyrene beads) |
| Sample Flow Rate | 10–240 µL/min (user-selectable in 10/30/60 µL/min presets or fully adjustable) |
| Fluorescence Sensitivity | ≤30 MESF (FITC), ≤10 MESF (PE) at 15-parameter configuration |
| Event Acquisition Rate | Up to 30,000 events/sec (continuous, software-adjustable) |
| Automated Sample Loading | Integrated plate-based autosampler optional |
| Compensation Method | Real-time automatic compensation with saved compensation matrices |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Sorting Flow Cytometer |
| Application Domain | Research |
| Laser Configuration | Up to 4 Lasers (405 nm, 488 nm, 561 nm, 638 nm) |
| Fluorescence Detection Channels | 15 Total (Configurable BPF Filters) |
| Optical Precision | rCV < 3% across all channels |
| Side Scatter Resolution | < 300 nm (488 nm excitation), < 200 nm (405 nm excitation) |
| Sample Flow Rate | 10–100 µL/min |
| FITC Sensitivity (488 nm) | < 30 MESF |
| Cell Acquisition Rate | 40,000 events/sec |
| Sorting Throughput | 30,000 cells/sec |
| Nozzle Diameter | 100 µm |
| Droplet Frequency | 35 kHz |
| Sorting Logic | Quadruple-Stream Sorting with Mixed-Mode and Discard-Capture Capability |
| Compensation | Fully Automated Real-Time Compensation |
| Sample Loading | Integrated Auto-Sampler (40,000 events/sec loading speed) |
| Voltage Adjustment Required | No |
| Biosafety Options | Optional Aerosol Containment Cabinet or Standalone Aerosol Exhaust System |
| Software Platform | CytExpert for CytoFLEX SRT (FDA 21 CFR Part 11–Ready Audit Trail, GLP/GMP-Compliant Data Integrity Features) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Cytomics FC500 |
| Product Type | Flow Cytometry Analyzer |
| Laser Configuration | Single or dual collinear lasers |
| Fluorescence Channels | 5-color detection |
| Sample Formats | 12×75 mm tubes, 24-/48-/96-well microplates, Eppendorf tubes |
| Software | CXP Data Acquisition and Analysis Software |
| Compliance | Designed for GLP-compliant research environments |
