Thermo Hygrometer
Filter
Showing 1–30 of 39 results
| Origin | Other Regions |
|---|---|
| Manufacturer Type | Distributor |
| Domestic Product | Yes |
| Model | 8830 |
| Pricing | Upon Request |
| Infrared Temperature Range | -30 to 360 °C |
| Resolution | 0.1 °C |
| Basic Accuracy | ±1.5% of reading |
| K-Type Thermocouple Input Range | -15 to 1300 °C |
| Data Hold Function | Yes |
| Backlit LCD Display | Yes |
| Data Memory | Yes |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SI-111 |
| Operating Wavelength | 8–14 µm |
| Field of View | 22° half-angle |
| Accuracy | ±0.2 °C @ −10 to +65 °C |
| Repeatability | ±0.05 °C @ 10 to +65 °C |
| Response Time | <1 s |
| Output | 60 µV/°C (target), 0–2500 mV (sensor body temperature) |
| Housing | Anodized aluminum with germanium optical window |
| Dimensions | Ø23 mm × 60 mm |
| Weight | 190 g |
| Cable | 4.5 m, 4-conductor shielded |
| Operating Ambient | −55 to +80 °C, 0–100 % RH |
| Power Supply | 2.5 V excitation for thermistor |
| Brand | AS ONE |
|---|---|
| Model | AD5680 |
| Temperature Range (Internal) | −10 to +50 °C |
| Temperature Range (External Probe) | −50 to +70 °C |
| Relative Humidity Range | 20–100 %RH |
| Display | Simultaneous Temperature (°C), Relative Humidity (%RH), and Real-Time Clock |
| Data Logging | Max/Min Hold Memory |
| Power Supply | Two AA Batteries (Included) |
| Mounting | Wall-Mountable or Desktop-Stable Design |
| External Sensor Cable Length | 3 m (Standard with Model 2-7397-01) |
| Dimensions (W×D×H) | 100 × 25 × 120 mm |
| Weight | 180 g |
| Brand | AS ONE |
|---|---|
| Model | CC-2544-01 |
| Temperature Range | −30 °C to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Humidity Range | 0–100 %RH |
| Humidity Accuracy | ±3–5 %RH (at 23 °C ±2 °C) |
| Humidity Resolution | 1 %RH |
| Data Storage Capacity | 15,000 readings |
| Sampling Interval | 2 s to 24 h adjustable |
| Logging Start Mode | Immediate or Delayed (1–120 s) |
| Alarm Function | Configurable High/Low Thresholds with Visual Indication |
| Display | Dual-line LCD showing real-time temperature/humidity alternately |
| Power | Single AA alkaline battery (typical life ≥12 months at 10-min interval) |
| Weight | 150 g |
| Operating Environment | −30 °C to +70 °C |
| Storage Environment | −50 °C to +90 °C |
| Interface | USB 2.0 |
| Compliance | CE-marked, RoHS-compliant |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model No. | 1-624-01 |
| Instrument Type | Thermo-Hygrometer |
| Minimum Scale | Temperature ±2°C, Humidity ±5% RH |
| Accuracy | Temperature ±2°C |
| Mounting | Wall-Mounted |
| Dimensions | 180 × 180 × 35 mm |
| Brand | BJBY |
|---|---|
| Model | BY-2003HT |
| Type | Thermohygrometer |
| RH Range | 0–100% RH |
| RH Accuracy | ±2% RH (0–90% RH, 20°C), ±3% RH (90–100% RH, 20°C) |
| RH Resolution | 0.1% RH |
| Temperature Range | −40 to +60°C |
| Temp Accuracy | ±0.3°C (at 20°C) |
| Temp Resolution | 0.1°C |
| Display | Segment LCD with backlight |
| Power | 9 V alkaline battery |
| Battery Life | ~80 h |
| Housing Material | ABS plastic |
| Calibration | User-adjustable two-point calibration |
| Low-battery indicator | Yes |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | BlackGlobe-L |
| Operating Temperature Range | -50 °C to 100 °C |
| Measurement Range | -5 °C to 95 °C |
| Interchangeability Error | < ±0.2 °C (0–70 °C) |
| Polynomial Linearity Error | ±0.5 °C (-7 °C to 90 °C) |
| Maximum Cable Length | 305 m |
| Compatibility | All Campbell Scientific dataloggers except CR200X series |
| Sensor Type | Black Globe Thermometer for WBGT Index Calculation |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | M-2000 |
| Instrument Type | Humidity & Temperature Calibration Chamber |
| Humidity Range | 10–95 %RH (at 23 °C) |
| Temperature Range | 10–50 °C |
| Humidity Accuracy | ±1 %RH (10–90 %RH), ±2 %RH (>90 %RH) |
| Temperature Accuracy | ≤±0.2 °C |
| Chamber Humidity Stability | ±0.2 %RH (20–25 °C) |
| Chamber Temperature Stability | ±0.1 °C |
| Chamber Humidity Uniformity | ±0.3 %RH |
| Chamber Temperature Uniformity | ±0.2 °C |
| Humidity Setpoint Response Time (Δ30 %RH) | <10 min |
| Cooling Rate | 1.0 °C/min (ambient 23 °C) |
| Heating Rate | 3.0 °C/min (ambient 23 °C) |
| External Gas Flow Rate | up to 3 L/min (requires external temperature-stable loop) |
| Dimensions (W×D×H) | 450 × 360 × 210 mm |
| Net Weight | 13 kg |
| Digital Interface | RS232 / RS485 (optional) |
| Calibration Certificate | NVLAP-accredited |
| Reference Standard | Dual-Pressure Humidity Generator |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | PHYSICS 1000 |
| Measurement Principle | Dual-channel Pt100 resistance thermometry |
| Resolution | 0.001 K (selectable) |
| Accuracy | ±0.01% of reading + 3 digits |
| Temperature Range | −200 °C to +400 °C |
| Input Channels | 2 electrically isolated Pt100 inputs |
| Display | 128 × 64 pixel graphical LCD with dual-line backlight |
| Interfaces | USB, RS-232 (V.24), Ethernet, Bluetooth |
| IP Rating | IP54 |
| Data Storage | 99 manual readings + internal 25,000-point logging memory |
| Power | 3 × AA alkaline batteries (20 mA typical, 40 mA with backlight) or external 12 V DC adapter |
| Dimensions | 127 × 83 × 42 mm |
| Weight | 290 g |
| Compliance | DKD/DAkkS traceable calibration available |
| Software Support | PC-based configuration and data export (CSV, Excel-compatible) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TFX 430 |
| Temperature Range | −100 °C to +500 °C (−148 °F to +932 °F) |
| Temperature Accuracy | ±0.05 °C (−50 °C to +199.99 °C), ±0.2 °C (other ranges) |
| Temperature Resolution | 0.01 °C (−10.00 °C to +199.99 °C), 0.1 °C (other ranges) |
| Humidity Range | 0–100 %RH |
| Humidity Accuracy | ±2.5 %RH (10–90 %RH), ±0.5 °C (temperature) |
| Humidity Resolution | 0.1 %RH, 0.1 °C |
| Sampling Interval | 1–15 s |
| IP Rating | IP40 |
| Dimensions | 115 × 54 × 22 mm |
| Weight | ~90 g |
| Battery | 3.0 V Li-ion, 1000 mAh (up to 5-year service life) |
| Sensor Type | External capacitive humidity sensor (TFH 61) + external NTC thermistor probe |
| Calibration | Factory-calibrated with traceable certificate |
| Compliance | Conforms to DIN EN 60751 (Pt100 reference context), ISO/IEC 17025-aligned calibration documentation |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | THI 350 |
| Temperature Range | −60 °C to +500 °C |
| Temperature Accuracy | ±1.0 °C (15–35 °C), ±2.0 °C (−33–500 °C and outside nominal range) |
| Emissivity Adjustment | 0.1–1.0 (default 0.95) |
| Temperature Resolution | 0.1 °C (−9.9 to 199.9 °C) |
| Response Time | 1 s |
| Relative Humidity Range | 1–99 % RH |
| RH Accuracy | ±3 % RH (20–80 % RH), ±5 % RH (outside that range) |
| Distance-to-Spot Ratio | 12:1 |
| Operating Ambient Temperature | 0–50 °C |
| Power | 2 × AAA alkaline batteries (typical life: 180 h, min. 140 h continuous) |
| Dimensions (L×W×H) | 46 × 143 × 184.8 mm |
| Calibration | Factory-calibrated with traceable certificate |
| Probe Types Supported | Fixed capacitive (TFH 610), flexible cable-mounted capacitive (TFH 620), and integrated infrared + capacitive (THI 350) |
| Brand | GFS |
|---|---|
| Origin | Germany |
| Model | TPG1 |
| Instrument Type | Humidity Generator |
| Flow Rate | ~2 L/min |
| Dew Point Range | −50 °C to +10 °C |
| Accuracy | ±2 °C (dew point) |
| Display | 10-inch touchscreen LCD |
| Control Modes | Fixed dew point, ramp (linear slope), or step profiling |
| Chamber Material | Stainless steel, borosilicate glass, brass, PTFE, NBR, PUR, aluminum, nickel |
| Power Supply | 230 VAC, 50–60 Hz |
| Power Consumption | 50 W |
| Communication Interfaces | RS232, optional 4–20 mA input/output (4 channels) |
| Operating Temperature | −10 °C to +40 °C |
| Enclosure Rating | IP20 |
| Dimensions | 19″ rack mount, 6 HU |
| Weight | ~25 kg |
| Long-term Stability | Optimized for continuous calibration-grade operation |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI 8751 / HI 8757 |
| Temperature Range (HI 8751) | –40.0 to +150.0 °C |
| Temperature Range (HI 8757) | –50.0 to +199.0 °C and +200 to +1350 °C |
| Sensor Type | HI 8751 — Precision Silicon RTD Probe (HI765PW) |
| Accuracy (HI 8751) | ±0.2 °C (–10.0 to +80.0 °C) |
| Accuracy (HI 8757) | ±1.0 °C or ±0.75% of reading (whichever is greater) |
| Resolution | 0.1 °C (–50.0 to +999.9 °C), 1 °C above 1000 °C |
| Power | 9 V alkaline battery (included) |
| Housing | ABS plastic (HI 8751), IP65-rated ABS with stainless steel probe (HI 8757) |
| Compliance | CE, RoHS, EN 61326-1 (EMC for laboratory equipment) |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI9060 |
| Instrument Type | Portable Temperature Meter |
| Enclosure Rating | IP67 (waterproof) |
| Power Supply | 4 × 1.5 V AA batteries |
| Probe Interface | Standard BNC or mini-DIN (model-dependent) |
| Memory Capacity | Up to 100 data points |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | -20 to 70 °C |
| Relative Humidity Limit | Up to 95 % RH non-condensing |
| Calibration Points | Single-point or multi-point via calibration standards (e.g., HI765-18C, HI765000C, HI765070C) |
| Probe Compatibility | HI765BL (1 m thermistor probe), HI765L/10 (10 m thermistor probe), HI766C (penetration thermocouple probe), HI2602 carrying case |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI 146-00 / HI 151-00 |
| Instrument Type | Wall-Mounted Digital Thermohygrometer |
| Probe Type | Stainless Steel Needle Probe (HI 146-00) |
| Display | LCD |
| Power | 1 × 1.5 V AAA battery |
| Calibration Verification | Built-in self-test mode (READ/TEST switch) |
| Compliance | Designed for HACCP, ISO 22000, and FDA Food Code-compliant environments |
| Sample Contact | Air, gases, liquids, semi-solids, frozen foods |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | HGS-W21 (Wireless Indoor Temp/RH Logger), HGS-R5 (433 MHz Wireless Data Concentrator) |
| Communication | 433 MHz ISM-band RF (licensed by China NRR) |
| Storage | Onboard non-volatile memory (≥32,000 records per unit) |
| Alarm | Configurable high/low thresholds with local buzzer |
| Compliance | Designed to support GSP (China Good Supply Practice), GLP (Good Laboratory Practice), and archival environmental control per DA-001–2021 (National Archives Administration of China) |
| Connectivity | Up to 250 wireless sensors per concentrator (HGS-R5) |
| Software | Windows-compatible (Win7–11), real-time graphing, statistical reporting (min/max/avg), audit trail export (CSV/PDF), alarm log with timestamp and event annotation |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LF-TD 180 |
| Instrument Type | Thermo-Hygrometer |
| Humidity Range | 0–100 % RH |
| Temperature Range | –20 °C to +180 °C |
| Humidity Accuracy | ±2.0 % RH (10–90 % RH) |
| Temperature Accuracy | ±0.3 °C (+10 to +60 °C) |
| Output Signals | Dual 4–20 mA (RH and Temp, separately scaled) |
| Power Supply | 12–29 VDC (nominal 24 VDC) |
| Sensor Head Material | Stainless steel |
| Electronics Housing Material | Anodized aluminum |
| IP Rating | IP65 |
| Probe Dimensions | Ø12 mm × 100 mm |
| Electronics Dimensions | 70 mm (W) × 32 mm (H) × 120 mm (D) |
| Cable Length | 1 m (5-pin sensor connector) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MicroLOG Pro EC750 Pocket-Sized Temperature & Humidity Data Logger |
| Temperature Range | –40 to +80 °C |
| Relative Humidity Range | 0–100 %RH |
| Temperature Accuracy | ±0.2 °C |
| RH Accuracy | ±2 %RH @ 25 °C |
| Temperature Resolution | 0.1–0.2 °C (varies by range) |
| RH Resolution | 0.1 %RH |
| Memory Capacity | 52,000 data points |
| Sampling Interval | 10 s to 2 h |
| Display | 4-digit LCD with unit indicators (°C/°F/%RH/PH/V/mA/mS/AL-H/AL-L) |
| Communication | RS-232 (19.2 kbps), USB 1.1, IrDA (compatible with HP 82240B printer) |
| Power | 3.6 V Li primary battery (½AA, 1.2 Ah) |
| Battery Life | ~2 years (typical use, no external sensors or high-frequency sampling) |
| Dimensions | Ø72 mm × 22.9 mm |
| Weight | 55 g |
| Certifications | CE, FCC |
| Software | MicroLAB 1.1 (free, Windows-compatible) |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | LW |
| Instrument Type | Thermo-Hygrometer |
| Power Consumption | 3.0 W @ 12 VDC |
| Output Signal | 0–5 V DC |
| Substrate Material | Gold-Plated PCB |
| Mounting | Direct attachment to Monopod mounting bracket |
| Compliance | Designed for outdoor environmental monitoring per IEC 60529 IP65 enclosure rating |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | RH/T |
| Instrument Type | Thermo-Hygrometer |
| Temperature Range (Standard) | −40 °C to +65 °C |
| Temp Accuracy | ±0.1 °C |
| Temp Resolution | 0.1 °C |
| Relative Humidity Range | 0–100% RH |
| RH Accuracy | ±2.0% RH @ 25 °C (10–90% RH) |
| RH Hysteresis | ≤±0.8% of span |
| RH Linearity | ±0.5% RH (typical) |
| RH Repeatability | ±0.5% RH |
| Operating Ambient Temp | −40 °C to +85 °C |
| Output Options | RS-232 digital or analog (voltage/current) |
| Sensor Configurations | RTD, thermistor, or thermocouple options available |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ST-TH2O |
| Instrument Type | Soil Temperature Sensor |
| Measurement Range | -40°C to +65°C |
| Accuracy | ±0.3°C |
| Resolution | 0.1°C |
| Cable Length | 7.5 m (burial-rated, direct-burial compatible) |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | RS-WD |
| Instrument Type | Temperature Transmitter |
| Output Options | 4–20 mA / 0–5 V / 0–10 V |
| Supply Voltage | 10–30 V DC |
| Default Temperature Accuracy | ±0.5 °C @ 25 °C |
| Extended Range Accuracy | ±1.0 °C @ 25 °C |
| Transmitter Operating Temp. | −20 to +60 °C |
| Probe Operating Temp. | −40 to +80 °C (standard) |
| Probe Humidity Range | 0–100 %RH |
| Response Time (1 m/s airflow) | ≤10 s |
| Load Capacity | ≤600 Ω (current output), ≤250 Ω (voltage output) |
| Mounting Cutout | 60 mm² |
| Display | Integrated LCD |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RH-200 Relative Humidity Generator |
| Price | Upon Request |
| RH Range | 3–95% RH |
| RH Control Accuracy | ±1.0% RH |
| Temperature Control Range | Ambient to 50 °C |
| Dew Point Range | −25 °C to 50 °C |
| Standard Flow Rate | 500 mL/min (Optional High-Flow: up to 5 L/min) |
| Brand | Rotronic |
|---|---|
| Origin | Switzerland |
| Model | HC2A-S3 |
| Sensor Type | Thermo-Hygrometer Probe |
| Measurement Range | -50 to 100 °C / 0–100 %RH |
| Accuracy (Standard Mode) | ±0.8 %RH / ±0.1 K at 23 °C ±5 K |
| Accuracy (High-Accuracy Mode) | ±0.5 %RH / ±0.1 K at 10–30 °C |
| Calibration Points | 23 °C @ 10, 35, 80 %RH (standard) |
| Long-Term Stability | <1 %RH/year, <0.01 K/year |
| Response Time (t₆₃) | <15 s |
| Output | Dual 0–1 VDC analog (configurable for T/RH/dew point) + UART digital interface |
| Power Supply | 3.3–5 VDC, 4.5 mA @ 3.3 VDC |
| Max Air Velocity | 20 m/s (with filter) |
| Housing Material | Polycarbonate |
| Filter | Polyethylene, 40 µm, white |
| Dimensions | Ø15 × 108 mm |
| Weight | 17 g |
| Compliance | FDA 21 CFR Part 11, GAMP 5, ISO/IEC 17025 traceable calibration |
| Software | ROTRONIC HW4 |
| Brand | Rotronic |
|---|---|
| Model | HC2AS3 |
| Sensor Type | Combined Temperature & Relative Humidity Probe |
| Origin | Switzerland |
| Temperature Sensor | PT100 Platinum Resistance Thermometer (Class A) |
| Temperature Range | −50 to +100 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.1 °C at 23 °C |
| Long-term Temperature Stability | <0.1 °C/year |
| RH Sensor | ROTRONIC Hygromer® IN-1 Capacitive Polymer Sensor |
| RH Range | 0 to 100.00 %RH |
| RH Resolution | 0.01 %RH |
| RH Accuracy | ±0.8 %RH at 23 °C (10–90 %RH), ±1.5 %RH at extremes |
| RH Long-term Stability | <1 %RH/year |
| Response Time (τ₆₃) | ≤22 s (at 1 m/s airflow, 23 °C) |
| Operating Temperature | −40 to +100 °C |
| Output Signal | 0–1 V analog (linear, ratiometric) |
| Supply Voltage | 5 VDC or 12 VDC |
| Current Consumption | <4.3 mA @ 5 VDC, <2.0 mA @ 12 VDC |
| Dimensions | Ø15 mm × 183 mm |
| Mass | 10 g |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LF-TD 150 |
| Instrument Type | Thermo-Hygrometer |
| Measurement Range | RH 0–100 %, Temp −20 to +150 °C |
| Accuracy | ±2.0 % RH (10–90 % RH), ±0.3 °C (10–60 °C) |
| Output | Dual 4–20 mA (RH and Temp, separately scaled) |
| Supply Voltage | 12–29 VDC (nominal 24 VDC) |
| Sensor Probe | Ø12 mm × 750 mm, Stainless Steel |
| Electronics Housing | Anodized Aluminum, IP65 |
| Operating Temp | Sensor Head −20 to +150 °C, Electronics −20 to +85 °C |
| Electrical Interface | 5-pole sensor connector with 5 m integrated cable |
| Optional Interfaces | LCD Display, Relay Output (humidity alarm), RS232, USB, Bluetooth (requires USB), PROFINET, Ethernet, Modbus RTU/TCP |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Flexi WET200 |
| Instrument Type | Humidity Generator |
| Temperature Range | Ambient to 70 °C |
| Relative Humidity Range | 5–95% RH |
| Gas Flow Rate | 20–50 mL/min |
| Humidity Stability | ±0.3% RH |
| Compatible Gases | He, Air, Ar, N₂, CO₂ |
| Heating Stem Temperature | Ambient to 85 °C |
| Control System | Eurotherm-based PID loop with integrated RH, T, and flow feedback |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2170 |
| Humidity Range | 0–100% RH |
| Temperature Range | −10 to +60 °C |
| Humidity Accuracy | ±3% RH (10–90% RH) |
| Temperature Accuracy | ±1 °C |
| Stability | <1% RH/year |
| Self-Heating | <100 µW |
| Display Resolution | 0.1 °F / 0.1 °C / 0.1 K / 0.1% RH |
| Units | °F, °C, K (for dew point and temperature), % RH |
| Probe Diameter | 1" handle / 0.5" sensor tip |
| Length | 11" (including handle) |
| Weight | 10 oz |
| Cable | Standard 1 ft (0.3 m), optional 5 ft (1.5 m) |
| Sensor Type | Temperature-Compensated Capacitive Polymer |
| Calibration Traceability | NIST-traceable factory calibration |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 108 |
| Instrument Type | Digital Food Thermometer |
| IP Rating | IP67 (with Softcase) |
| Thermocouple Compatibility | Type K and Type T |
| Measurement Range | –50 to +300 °C (both types) |
| Accuracy | ±0.5 °C (–30 to +70 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₀) | ≤10 s in moving liquid |
| Display | Single-line LCD, large-digit |
| Operating Temperature | –20 to +60 °C |
| Storage Temperature | –30 to +70 °C |
| Weight | 154 g (instrument + battery), 210 g (incl. Softcase) |
| Dimensions | 140 × 60 × 24 mm |
| Housing Material | ABS / ABS-PC with 10% glass fiber |
| Power Supply | 3 × AAA rechargeable batteries |
| Battery Life | up to 2500 h at 23 °C |
| Compliance | EN 13485, HACCP principles, EU EMC Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Model | 0572 6560 |
| Sensor Type | Integrated NTC temperature sensor + capacitive humidity sensor |
| Measurement Range | -20 to +70 °C, 0–100 %RH |
| Accuracy | ±0.5 °C (-20 to +70 °C) ±1 digit |
| Resolution | 0.1 °C, 0.1 %RH |
| Data Storage Capacity | 16,000 readings |
| Logging Interval | 1 min to 24 h (user-selectable) |
| Operating Temperature | -20 to +70 °C |
| Storage Temperature | -40 to +70 °C |
| Protection Class | IP20 |
| Power Supply | Included battery (CR2450) |
| Interface | USB |
| Software Compatibility | Windows XP, Vista, Windows 7 |
| Compliance | CE, RoHS |
| Data Retention | Non-volatile memory — data preserved even after battery depletion |