Electromagnetic Field Strength Analyzer
Filter
Showing 1–30 of 39 results
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HDEM-1 |
| Pricing | Upon Request |
| Frequency Range | 3 kHz – 30 MHz |
|---|---|
| Electric Field Range | 0.02–1000 V/m |
| Magnetic Field Range | 0.6 mA/m – 300 A/m |
| Resolution Bandwidth | 1 kHz (min) |
| Dynamic Range | 80 dB |
| Battery Life | Up to 12 h (rechargeable Li-ion) |
| Probe Dimensions | 92 × 92 × 109 mm |
| Compliance | Designed for IEC 61786-1, IEEE C95.3, and EN 50492 assessment workflows |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EME Guard |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | EME Guard XS |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EME Spy 121/100 |
| Price | Upon Request |
| Frequency Range (Spy 121) | 88 MHz – 2.5 GHz |
| Frequency Range (Spy 100) | 88 MHz – 2.17 GHz |
| Electric Field Probe | Triaxial isotropic E-field sensor |
| Sensitivity (Spy 121) | 0.05 V/m (dynamic range up to 10 V/m, 46 dB) |
| Sensitivity (Spy 100) | 0.05 V/m (dynamic range up to 5 V/m, 40 dB) |
| Data Points (Spy 121) | 12,540 |
| Data Points (Spy 100) | 7,168 |
| Logging Interval | 4–255 seconds |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | ≤85 % RH (non-condensing) |
| Battery | Rechargeable Li-ion |
| Battery Life | >20 days (typical continuous logging at 30-sec interval) |
| Power Adapter | 100–240 VAC, 50–60 Hz |
| Charger Output | Max 0.9 A |
| Dimensions (H × L × W) | 193 × 95.6 × 69.4 mm |
| Weight | 450 g |
| Ingress Protection | IP50 |
| Compliance Reference | ICNIRP 2020 Guidelines for Human Exposure to Electromagnetic Fields |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EME Spy 140 |
| Price | Upon Request |
| Brand | GIGAHERTZ (distributed by PKSAIR) |
|---|---|
| Origin | Germany |
| Model | NFA-1000 |
| Frequency Range | 5 Hz – 1000 kHz |
| Electric Field Measurement Range | 0.1 – 1999 V/m |
| Magnetic Field Measurement Range | 0.1 – 19999 nT |
| Measurement Accuracy | ±2% at 50/60 Hz |
| Detector Types | True RMS, Peak Hold |
| Sampling Rate | Up to 110,000 samples/sec |
| data logging | 10 records/sec to microSD card |
| Power Supply | Rechargeable NiMH battery (48 h typical operation) or DC input |
| Dimensions | 70 × 175 × 30 mm |
| Weight | 2.1 kg |
| Brand | Gigahertz Optik |
|---|---|
| Origin | Germany |
| Model | HFE59B |
| Frequency Range | 27 MHz – 3.3 GHz |
| Measurement Accuracy | ±3 dB (27 MHz – 3.3 GHz) |
| Electric Field Range | 0.02–27.5 V/m |
| Display Unit | μW/m² |
| Antenna Interface | SMA, 50 Ω |
| Power Supply | Rechargeable NiMH battery or DC input |
| Dimensions | 70 × 120 × 30 mm |
| Weight | 2.1 kg |
| Brand | Holaday |
|---|---|
| Origin | USA |
| Model | HI3604 |
| Frequency Range | 30–2000 Hz |
| Electric Field Range | 1 V/m – 200 kV/m |
| Magnetic Field Range | 0.2 mG – 20 G |
| Accuracy | ±1% (typical, referenced to NIST-traceable calibration) |
| Display | LCD with unit selection (mG, G, V/m, kV/m) and bar-graph visualization |
| Data Storage | 127 internal readings |
| Power | Two 9V alkaline batteries (NEDA 1604A) |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| RMS Detection | True RMS for non-sinusoidal waveforms |
| Polarization Response | Single-axis (electric and magnetic sensors optimized for linear polarization alignment) |
| Output | Analog preamp output (1 mV per unit full scale) via 3.5 mm audio jack |
| Optional Digital Interface | Fiber-optic link compatible with HI-3616 remote control unit |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | DHK-100 |
| Frequency Range | 1 Hz – 6 GHz (typical operational coverage per probe configuration) |
| Measurement Accuracy | ±0.5 dB (calibrated reference conditions) |
| Electric Field Strength Range | 0.1 V/m – 1000 V/m (dependent on probe selection) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DHK-200 |
| Frequency Range | Selectable (e.g., 1 Hz – 100 kHz) |
| Measurement Accuracy | Compliant with GBZ/T 189.3–2018 and HJ 681–2013 standards |
| Electric Field Range | 4 mV/m – 100 kV/m |
| Magnetic Field Range | Not specified in input (assumed compliant with GBZ/T 189.3–2018, typically 0.01 µT – 10 mT) |
| Display | 6.5-inch color HD touchscreen |
| Storage | 60 GB internal |
| Connectivity | Optical fiber, Wi-Fi, Bluetooth |
| Positioning | Built-in BeiDou GNSS module |
| Data Export | CSV-compatible table files |
| Compliance | GB 8702–2014, GBZ 2.2–2007, GBZ/T 189.3–2018, HJ/T 10.2–1996, HJ/T 10.3–1996, HJ 681–2013, HJ 24–2014, HJ 1113–2020, DL/T 799.7–2019, DL/T 988–2023, T/CECS 725–2020 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICD-1 |
| Price Range | USD 7,000 – 14,000 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NTH-310F |
| Price Range | USD 13,500 – 27,000 (FOB) |
| Frequency Range | 100 kHz – 6.5 GHz |
| Measurement Accuracy | ±3 dB (100 MHz – 3.3 GHz) |
| Electric Field Range | 0.01 – 9999 V/m |
| Magnetic Field Range | 0.0001 – 265.3 A/m |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EME WIDE |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Frequency Range | 100 kHz – 6.5 GHz |
| Measurement Accuracy | ±1 dB (100 MHz – 2.7 GHz), ±1.5 dB (2.7 GHz – 6.5 GHz) |
| Electric Field Range | 0.35 – 350 V/m |
| Brand | Narda |
|---|---|
| Origin | Germany |
| Model | AMB 8057 |
| Frequency Range (E-field) | 100 kHz – 3 GHz |
| Frequency Range (H-field) | 10 Hz – 5 kHz |
| Data Storage Capacity | Up to 338 days @ 15-min intervals (3-band mode) |
| Sampling Interval | 3 seconds (simultaneous multi-band acquisition) |
| Communication | Dual-mode GSM/GPRS + RS-232C |
| Power Supply | Integrated Li-ion battery (3.6 V, 13 Ah) with solar panel (4 V, 2.5 Ah lead-acid backup) |
| Operating Temperature | −10 °C to +50 °C |
| Ingress Protection | IP54 |
| Data Capture Rate | ≥99% |
| Alarm Triggers | Field strength exceedance, memory full, temperature out-of-range, low battery, probe disconnection, enclosure open |
| SMS Alert Support | Up to two mobile numbers |
| Software | AMB-8057-SW-02 (data download, threshold-based alerts, RMS/AVG/MAX computation, linear/logarithmic plotting, calibration traceability) |
| Brand | Narda |
|---|---|
| Origin | Germany |
| Model | EFA-300 |
| Frequency Range (Broadband) | 5 Hz – 32 kHz |
| Measurement Modes | RMS, Peak, Vector Peak, Time-Domain STD Weighting |
| Filter Options | Bandpass (15–2000 Hz, 0.1 Hz resolution), Bandstop (15–2000 Hz) |
| Probe Compatibility | Isotropic Magnetic Field Probes (A-type: 100 cm² |
| D-type | 30 mm diameter), Isotropic Electric Field Probe (up to 200 kV/m) |
| Typical Broadband Uncertainty | ±3% @ ≥40 nT (5–2 kHz), ±3% @ ≥5 V/m (5–2 kHz) |
| Display | 128×64 LED matrix with backlight |
| Interface | Optical RS-232 (fiber optic cable included) |
| Operating Temperature | 0–50 °C |
| Battery | Rechargeable NiMH (5×C-cell) |
| Dimensions | 110 × 200 × 60 mm |
| Weight | ~1000 g |
| Calibration Interval | 24 months |
| Optional Modules | FFT Narrowband Spectrum Analysis & Harmonic Measurement (9 harmonics), Remote PC Control Software EFT-TS |
| Brand | Narda |
|---|---|
| Origin | Germany |
| Model | PMM 8053B |
| Frequency Range | 5 Hz – 40 GHz |
| Low-Frequency Probe | EHP-50C (5 Hz – 100 kHz, E/H-field isotropic, 0.01 V/m – 100 kV/m / 1 nT – 10 mT) |
| RF Probes | EP-105 (100 kHz – 1 GHz), EP-300/EP-330/EP-301 (100 kHz – 3 GHz), EP-183 (1 MHz – 18 GHz), EP-408 (1 MHz – 40 GHz), HP-102 (30 MHz – 1 GHz), HP-032 (100 kHz – 30 MHz) |
| Isotropic Measurement Capability | Yes |
| Spectral Analysis | Real-time FFT with 7 selectable bandwidths (LF), XYZ vector resolution |
| Data Logging | Continuous 24-h recording, internal memory + PC export via RS-232/fiber optic |
| Compliance | IEC 61786-1:2013, IEC 62232:2017, EN 50492:2008, IEEE C95.3-2019 |
| Calibration | Internal reference source, traceable to PTB/NIST |
| Remote Operation | Up to 40 m via fiber optic |
| Multi-probe Expansion | Up to 16 probes (optional) |
| Brand | Narda |
|---|---|
| Origin | Germany |
| Model | PMM8056 |
| Electric Field Frequency Range | 3 MHz–40 GHz |
| Electric Field Measurement Range | 0.6 V/m–30 V/m |
| Electric Field Frequency Response | ±3 dB |
| Magnetic Field Frequency Range | 30 MHz–300 MHz |
| Magnetic Field Measurement Range | 7.3 mA/m–3 A/m |
| Magnetic Field Frequency Response | ±3 dB |
| Display | Backlit LCD showing real-time field strength, user-defined thresholds, date/time |
| Audio-visual Alarm | Threshold-triggered audible tone and visual indicator |
| Data Logging | 1 sample/sec (instant), max value every 60 sec, 6-min moving average |
| Interface | Infrared (IR) PC interface |
| Battery Life | 40 h (9 V alkaline, 1200 mAh) |
| Dimensions | 62 × 30 × 190 mm |
| Weight | 200 g |
| Probe Type | Integrated isotropic E-field and H-field sensors |
| Compliance | Designed for compliance with GB 8702–2014 (China EMF exposure limits), ICNIRP 2020 guidelines, and IEEE C95.1–2019 |
| Brand | Narda |
|---|---|
| Origin | Germany |
| Model | SRM 3000 |
| Frequency Range | 100 kHz – 3 GHz |
| Measurement Modes | Safety Assessment, Spectrum Analysis (with user-defined RBW integration), UMTS P-CPICH Option, Time-Domain Monitoring |
| RBW | 1 kHz – 5 MHz (configurable) |
| Dynamic Range | −121 dBm to +23 dBm |
| E-field Probe | Isotropic, 5 MHz – 3 GHz, Max. 200 V/m (Destruction Limit: 1000 V/m) |
| Operating Temperature | −10 °C to +50 °C |
| Humidity | Up to 95 % RH (IP54) |
| Battery Life | ~3.5 h |
| Dimensions | 255 × 195 × 60 mm |
| Weight | 1.9 kg (instrument), 450 g (probe) |
| Calibration Interval | 24 months |
| Brand | Narda |
|---|---|
| Origin | Germany |
| Model | SRM-3006 |
| Frequency Range | 9 kHz – 6 GHz |
| Display Range | DANL to +20 dBm |
| Measurement Range | −30 dBm to +20 dBm (1 dB steps) |
| RF Input Attenuation | 0–50 dB (1 dB steps) |
| Level Uncertainty | ≤1.2 dB (15–30 °C) |
| Antenna Auto-Detection | Yes (type & calibration date) |
| Compliance Standards | HJ 1151–2020, IEC 62232, EN 50492, ICNIRP, GB 8702 |
| Brand | PMM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | C4 |
| Price | Upon Request |
| Frequency Range | 1 Hz to 40 GHz |
| Measurement Resolution | 0.01 V/m |
| Electric Field Measurement Range | Determined by Connected E-Field Probe Specifications |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EHP-50B & EHP-50C |
| Frequency Range | 5 Hz – 100 kHz |
| Axes | X/Y/Z triaxial measurement |
| Calibration Data Storage | Built-in EEPROM |
| Interface | Fiber-optic (compatible with PMM 8053A analyzer) |
| Power Supply | Rechargeable battery (up to 7 days in autonomous monitoring mode) |
| Sensor Architecture | Orthogonal magnetic coils + orthogonal parallel-plate capacitors |
| DSP Engine | Integrated digital signal processor with 7 selectable resolution bandwidths (RBW) |
| Spectral Analysis | Real-time FFT-based spectrum display on host unit |
| Compliance | Designed for IEC 61786-1, ICNIRP 2010/2020, IEEE C95.1, and EU Directive 2013/35/EU |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP-408 |
| Frequency Range | 1 MHz to 40 GHz |
| Electric Field Measurement Range | 0.8 V/m to 800 V/m |
| Measurement Resolution | 0.01 V/m |
| Isotropy (typ.) | ±1 dB @ 200 MHz |
| H-Field Rejection | >20 dB |
| Dynamic Range | >60 dB |
| Overload Protection | >1000 V/m |
| Calibration Memory | Built-in EEPROM |
| Dimensions | 317 mm × Ø52 mm |
| Weight | 90 g |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP 601 |
| Frequency Range | 10 kHz – 9.25 GHz |
| Electric Field Measurement Range | 0.5 – 500 V/m |
| Resolution | 0.01 V/m |
| Overload Protection | > 1000 V/m |
| Dynamic Range | > 60 dB |
| Isotropy | ±0.5 dB |
| Amplitude Flatness | ±0.4 dB |
| Sensor Type | Six Monopole Antennas (Triaxial X/Y/Z) |
| Weight | 23 g |
| Dimensions | 21 mm (sphere diameter) × 16 mm (sensor length) × 53 mm (total length) |
| Operating Temperature | –10 °C to +50 °C |
| Power Supply | Rechargeable Li-ion Battery or External DC Input |
| Temperature Compensation | 0.1 °C per °C |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP-602 |
| Frequency Range | 5 kHz to 9.25 GHz |
| Electric Field Measurement Range | 1.5 V/m to 1500 V/m |
| Measurement Resolution | 0.01 V/m |
| Isotropy (Typical) | ±0.2 dB |
| Frequency Response Flatness (with correction enabled) | ±0.4 dB (50 MHz – 7.5 GHz) |
| Dynamic Range | >60 dB |
| Weight | 22 g |
| Operating Time | Up to 100 h (rechargeable Li-Mn battery) |
| Communication | Duplex optical fiber (up to 60 m) |
| Sensor Type | Spherical symmetric monopole array (6-axis isotropic sensing) |
| Overload Protection | >3000 V/m |
| Frequency Range | 30 Hz–2000 Hz |
|---|---|
| Electric Field Range | 0–20,000 V/m |
| Measurement Accuracy | ≤ ±1.5 dB |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤ 80 % RH |
| Power Supply | Rechargeable 8.4 V battery or 9 V alkaline (6F22) |
| Form Factor | Portable |
| Weight | 550 g |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | INSITE Box |
| Pricing | Upon Request |
| Frequency Range | 525 kHz – 5.85 GHz |
| Electric Field Sensitivity | 0.005–5 V/m (selectable dynamic range up to 60 dB) |
| Measurement Resolution | 7168 data points per scan |
| Sampling Interval | 2–255 seconds |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | 230 VAC, 50 Hz or 12 VDC (solar-compatible) |
| Enclosure Rating | IP54 |
| Dimensions (w/o solar) | 250 × 317 × 1350 mm |
| Weight (w/o solar) | 18 kg |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SC22 |
| Frequency Range | 0.5 Hz – 5 kHz |
| Maximum Compensatable AC Field | ±30 mG (±3.0 µT) peak-to-peak |
| Field Step Response Time | <100 µs |
| Sensor Sensitivity | <1 nT/√Hz (typ.) |
| Axis Configuration | Full 3-axis (X, Y, Z) vector compensation |
| Interface | USB 2.0 for real-time monitoring and configuration |
| Dual-Sensor Support | Yes |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Compliance | CE, RoHS, IEC 61326-1 (EMC for laboratory equipment) |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | NHT-310 |
| Pricing | Upon Request |
| Frequency Range | DC – 40 GHz |
| Display | Monochrome backlit LCD (128 × 64 pixels, 7 cm diagonal) |
| Refresh Rate | 200 ms |
| Measurement Units | mW/cm², W/m², V/m, A/m, Tesla |
| Result Modes | Actual, MAX, AVG, Median, X/Y/Z instantaneous |
| Data Storage | 21,504 samples (21,000 typical) |
| Logging Duration | >24 h at 5 s interval |
| Battery Life | ~72 h (backlight off) |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −20 °C to +70 °C |
| Humidity | 5–95% RH (non-condensing) |
| Dimensions (host) | 160 × 98 × 30 mm |
| Weight (host) | 500 g |
| Housing | Magnesium-aluminum alloy |
| Integrated Sensors | Temperature, GPS (optional) |
| Analog Outputs | X/Y/Z SMA female connectors |
| Digital Interface | Full-duplex serial fiber optic port |
| Probe Interface | Plug-and-play LEMO™ with automatic recognition |
| Software | MicroLink (Windows XP/7/Vista/8) |
| Calibration Interval | 24 months |
| Probe Options | PROBE 01E (100 kHz – 6.5 GHz), PROBE 11E (5 Hz – 400 kHz), PROBE 10B (5 Hz – 400 kHz) |
| Brand | Starwood |
|---|---|
| Model | SMP620 |
| Category | Electromagnetic Field Strength Analyzer |
| Frequency Range | DC to 300 GHz (probe-dependent) |
| Electric Field Measurement Range | Up to 100 kV/m (with appropriate probe) |
| Magnetic Field Measurement Range | Up to 10 T (with appropriate probe) |
| Accuracy | ±1.5% (typical, probe- and frequency-dependent) |
| Data Storage | 4 GB internal (expandable) |
| Sampling Interval | 0.5 s to 100 h (1 s step) |
| Display Units | V/m, kV/m, µW/cm², mW/cm², W/m², nT, µT, mT, T, A/m, mG, % of exposure limit |
| Compliance Support | ICNIRP, IEEE C95.1, GB 8702–2014, EN 50492, EN 62233 |