Mass Spectrometry Instruments
Filter
Showing 1–30 of 487 results
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | 4110Bo |
| Pricing | Upon Request |
| Brand | 908 Devices |
|---|---|
| Origin | USA |
| Product Type | Imported Microfluidic ESI Source |
| Model | ZipChip® Platform |
| Pricing | Available Upon Request |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | API 5000™ |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | General-Purpose |
| Mass Range | 10–1200 m/z |
| Sensitivity | <100.1 fg on-column for selected analytes (e.g., reserpine, caffeine) |
| Resolution | Unit resolution (0.5–0.7 Da full width at half maximum) |
| Mass Accuracy | ≤0.1 Da (calibrated) |
| Operating Pressure Range | Up to 1200 psi (LC system compatible) |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Configuration | API4000 System (incl. ESI & APCI Ion Sources, Turbo V™ Source, Analyst® Software v1.6.2 or later) |
| Condition | Factory-Refurbished, Fully Qualified, IQ/OQ Performed |
| Compliance | Meets ASTM D7592, USP <1225>, ISO/IEC 17025:2017 requirements for method validation support |
| Warranty | 12-month comprehensive hardware & software support |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Model | API5000 |
| Configuration | LC-20AD HPLC + Nitrogen Generator |
| Condition | Refurbished & Functionally Verified |
| Brand | AB SCIEX |
|---|---|
| Model | QTRAP 5500 |
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC-manufactured system assembly and integration) |
| Price | USD 210,000 (FOB Shanghai, ex-works, subject to configuration verification) |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 4500 |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Application Scope | General-Purpose LC-MS/MS |
| Mass Range | 1000 Da |
| Sensitivity (MRM) | 100:1 (S/N) |
| Resolution | 0.5 Da (FWHM) |
| Mass Accuracy | 0.1 Da |
| Operating Pressure Range | 600 Torr (vacuum system) |
| Scan Speed | 12,000 Da/sec |
| Mass Stability | <0.1 Da/24 h |
| Dynamic Linear Range | 5 orders of magnitude |
| MRM Dwell Time | 1 ms |
| Ion Source | Turbo V™ with ESI and APCI capability |
| Brand | AB SCIEX |
|---|---|
| Model | TripleTOF 5600+ |
| Configuration | LC-MS/MS System with TOF-MS and MS/MSALL Acquisition |
| Mass Analyzer Type | Orthogonal Acceleration Time-of-Flight (oa-TOF) with Quadrupole Front-End |
| Resolution (FWHM) | ≥35,000 at m/z 1,000 |
| Mass Accuracy | < 2 ppm (internal calibration), < 5 ppm (external calibration) |
| Scan Speed | Up to 50 Hz for MS and MS/MS in high-resolution mode |
| Dynamic Range | >4 orders of magnitude |
| Ion Source Options | Turbo V™ or DuoSpray™ Ionization |
| LC Compatibility | Fully Compatible with Shimadzu, Waters, Thermo, and Agilent UHPLC Systems |
| Regulatory Compliance | Supports 21 CFR Part 11–compliant workflows via Analyst TF Software |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF 6600 |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Resolution | 30,000 (FWHM at m/z 1,000) |
| Sensitivity | 10.1 fmol (substance P, S/N ≥ 10) |
| Mass Accuracy | < 100 ppm (internal calibration), < 5 ppm (external calibration with lock mass) |
| Stability | ≤ 10 ppm RMS over 24 h |
| Acquisition Rate | 50 Hz (MS/MS spectra per second) |
| SWATH™ Acquisition | Up to 200 variable isolation windows per cycle |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA132 |
| Pricing | Available Upon Request |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA331 |
| Pricing | Available Upon Request |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA351 |
| Measurement Range | δ¹³C, δ¹⁷O, δ¹⁸O, and CO₂ mole fraction (150–2500 ppm, full-spec range) |
| Precision (1σ) | δ¹³C = 0.7‰/0.25‰/0.07‰ (1 s/10 s/100 s) |
| Max Drift (peak-to-peak, 15-min avg, 24 h) | δ¹³C < 0.5‰ |
| Response Time (95% step) | 10 s (with external pump, flow response < 5 s) |
| Operating Range | CO₂: 0–3000 ppm |
| H₂O | 0–70,000 ppm (non-condensing) |
| Data Output | RS232, analog (0–5 V / 4–20 mA) |
| Measurement Rate | Up to 1 Hz (user-selectable) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | GLA431 |
| Measurement Parameters | δ¹³C, δ¹⁸O, CO₂ (380–25,000 ppm), H₂O (4,000–60,000 ppm) |
| Precision (1σ) | δ¹³C = 0.15‰ (100 s), δ¹⁸O = 1‰ (100 s), CO₂ = 0.05 ppm (100 s), H₂O = 50 ppm (300 s) |
| Drift (24 h, peak-to-peak) | δ¹³C < 0.5‰ |
| Max. Measurement Rate | 1 Hz |
| Form Factor | Rack-Mount (68 kg) |
| Technology | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | GLA451-N2OI3 |
| Measurement Targets | N₂O, δ¹⁵N, δ¹⁵Nα, δ¹⁵Nβ, δ¹⁸O, δ¹⁷O* |
| Detection Principle | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) with Quantum Cascade Laser |
| Dynamic Range | >20× ambient environmental concentration |
| Measurement Frequency | Up to 10 Hz (high-flow mode) |
| Sample Introduction | Automated gas sampler or manual injection |
| Internal Temperature Control | Yes |
| Data Storage | Onboard computer with long-term archival capability |
| Output Interfaces | Analog + RS232 digital |
| Software Included | Instrument control, real-time diagnostics, isotope ratio calculation and time-series analysis |
| Brand | ABSCI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5500 |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | General-Purpose |
| Mass Range | m/z 5–1250 |
| MS/MS Sensitivity (ESI) | 50 fg, S/N > 500:1 |
| Resolution | 0.7 amu |
| Mass Accuracy | ±0.1 Da/24 h |
| Polarity Switching Time | ≤50 ms |
| Scan Speed | ≥12,000 amu/s |
| LC Pressure Capability | 15,000 psi |
| Column Temperature Range | 5–65 °C |
| Operating Pressure Range | 1200 psi |
| Brand | ABSCI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Triple Quadrupole |
| Application Scope | General-Purpose |
| Mass Range | 10–2000 m/z |
| Sensitivity | 100.1 fg on-column (for reserpine, SRM) |
| Resolution | 0.5 Da (unit resolution at peak width at half height) |
| Mass Accuracy | ±0.1 Da (external calibration) |
| Source Pressure | 1200 Torr (ESI/APCI source operating pressure) |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | HPMS-TQ |
| Application Scope | General-purpose LC-MS/MS analysis |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software | Fully integrated acquisition and quantitation platform with audit trail capability |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole Tandem Mass Spectrometer (QqQ MS/MS) |
| Configuration | Integrated Online SPE–UHPLC–MS/MS Platform |
| Application Scope | Targeted Quantitative Analysis in Complex Matrices |
| Regulatory Alignment | Designed for compliance with ISO/IEC 17025, USP <621>, and EPA Method 1694 workflows |
| Software Compatibility | Vendor-neutral front-end interface supporting third-party mass spectrometers (e.g., Waters Xevo TQ-S, Thermo Scientific TSQ Altis, Sciex QTRAP 6500+) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | expression |
| Pricing | Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASAP |
| Pricing | Available Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Instrument Type | Single Quadrupole |
| Mass Range | m/z 10–2000 |
| Sensitivity | 100:1 (S/N) |
| Resolution | 0.5–0.85 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Ionization Sources | ESI, APCI, ASAP, OPSI, iASAP, vAPCI |
| Models | expression S (up to m/z 1200), expression L (up to m/z 2000) |
| Vacuum Recovery Time | <30 min after relocation |
| Compliance | Fully compatible with 21 CFR Part 11 via DataApex Clarity and DataExpress software |
| Brand | Advion |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OPSI Open Port Sampling Interface |
| Pricing | Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | vAPCI |
| Instrument Type | Ion Source |
| Application Specificity | Dedicated Gas-Phase Interface |
| Analyte Polarity Range | Non-polar to Moderately Polar Compounds |
| Sensitivity | Compatible with Advion expression CMS Mass Spectrometer |
| Resolution | Defined by Coupled Mass Analyzer (e.g., Quadrupole) |
| Accurate Mass Capability | ±0.1 Da (when calibrated and operated under optimized conditions) |
| Operating Pressure | Ambient Atmospheric Pressure (~760 Torr) |
| Brand | Advion |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ICP-001/E01 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Mass Resolution (at 10% peak height, unit mass) | 0.9 amu |
| Detection Limits (ng·L⁻¹) | Be < 1 |
| Sensitivity (Mcps / mg·L⁻¹) | Li > 20 |
| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Model | Aerodyne N2O |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer (IRMS) Equivalent |
| Detection Principle | Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) |
| Measurement Targets | N₂O, δ¹⁵Nα (¹⁵N¹⁴N¹⁶O), δ¹⁵Nβ (¹⁴N¹⁵N¹⁶O), δ¹⁸O (N₂O) |
| Detection Limit | <1 ppt (v/v) for N₂O |
| Temporal Resolution | 1–10 Hz (configurable) |
| Path Length Options | 76 m or 400 m multipass cell |
| Precision (100 s) | δ¹⁵Nα ≤ 0.08‰, δ¹⁵Nβ ≤ 0.5‰, δ¹⁸O ≤ 0.5‰ |
| Operating Temperature Range | 10–35 °C (ambient) |
| with thermostatic enclosure | −20 to +40 °C |
| Temperature Stability | ±0.1 °C at setpoint (typically 30 °C) |
| Power Requirement | 500 W, 120/240 VAC, 50/60 Hz (pump excluded) |
| Dimensions (76 m) | 650 × 430 × 270 mm (W×D×H) |
| Weight | 35 kg |
| Dimensions (400 m) | 560 × 770 × 640 mm |
| Weight | 75 kg |
| Sampling Flow Rate | 0–20 slpm |
| Data Interfaces | RS-232, USB, Ethernet |
| Time Synchronization | GPS-enabled NTP server support |
| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Instrument Type | Stable Isotope Ratio Mass Spectrometry (IRMS)-Grade Laser Absorption Spectrometer |
| Measurement Principle | Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) with Astigmatic Multipass Cell |
| Detection Limits | Sub-ppt for N₂O, CH₄ |
| δ¹³C-CO₂ precision | 0.02‰ (120 s) |
| δ¹⁸O-CO₂ precision | 0.03‰ (120 s) |
| Sampling Frequency | 1–10 Hz configurable |
| Certified Compliance | ASTM D6348, ISO 13877 (adapted), GLP/GMP-ready data audit trail per FDA 21 CFR Part 11 |
| Software | TDLWINTEL v5.2 with HITRAN spectral replay, zero-spectrum background subtraction, real-time laser frequency stabilization, and passive cavity drift correction |
| Brand | Agela |
|---|---|
| Model | CHEETAH HP100 / Agela cMS |
| Instrument Type | Single Quadrupole LC-MS |
| Mass Range | m/z 10–1200 |
| Sensitivity | S/N ≥ 100:1 (100 pg reserpine, full scan |
| Resolution | 0.5–0.7 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Mass Stability | ±0.1 Da |
| ESI Ion Source | Standard |
| Polarity | Positive/Negative Switchable |
| Scan Speed | 5000 Da/sec (UPLC-compatible) |
| Flow Rate Compatibility | 10–100 µL/min |
| HPLC/Purification Pump Flow Range | 0.1–100 mL/min |
| Max Pressure | 20 MPa |
| UV Detection | 200–400 nm (D₂ lamp), optional 200–800 nm (D₂ + W lamp) |
| Wavelength Accuracy | ±1 nm |
| Bandwidth | 8 nm |
| Flow Precision | ±1% |
| Flow RSD | ≤0.3% |
| Pressure Pulsation | ≤0.3 MPa |
| Fraction Collector | 2D robotic, customizable coordinates, tube sizes: 13/15/18/25 mm |
| Operating System | Windows XP (industrial-grade PC) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Series | Multiple Catalog Numbers |
| Pricing | Available Upon Request |
| Brand | Agena Bioscience |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MassARRAY Nucleic Acid Mass Spectrometer |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Application Scope | General-Purpose Biomolecular Analysis |
| Resolution | >750 across full detection range |
| Sensitivity | ≥5% for routine somatic mutation detection |
| Stability | Measurement deviation ≤ ±5% |
| Throughput | ≤15 minutes for 96 samples |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1200 |
| Quotation | Upon Request |
| Instrument Type | Triple Quadrupole |
