| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash® 5.020 |
| Maximum Flow Rate | 300 mL/min |
| Maximum System Pressure | 20 bar |
| Pricing | Available Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® 5.050 |
| Flow Rate Range | up to 250 mL/min |
| Maximum Pressure | 50 bar |
| Dual-Mode Operation | Compatible with both flash chromatography and preparative HPLC (Prep-HPLC) methods |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CH-200P |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FL-MH100 |
| Pricing | Available Upon Request |
| Brand | Anyan Instrument |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AYJ-5 |
| Price Range | USD 8,400 – 9,100 (FOB China) |
| Tower Material | Borosilicate Glass 3.3 |
| Tower Volume | 5 L |
| Tower ID | 25 mm |
| Packing Height | 1 m |
| Total Height | ≈2800 mm |
| Heating Method | Electric Heating Jacket |
| Max Temp | 300 °C |
| Min Operating Vacuum | ≤0.1 mbar |
| Condenser Type | Vertical Shell-and-Tube |
| Heat Exchange Area | 0.2 m² |
| Reflux Ratio Control | Yes |
| Temperature Monitoring | Integrated Digital Display |
| Continuous Sampling Valve | Yes |
| Power Supply | 220 V, 50/60 Hz, Single Phase |
| Vacuum Pump | Optional (Rotary Vane or Water Aspirator) |
| Pressure Port & Pre-Pump Cold Trap | Optional |
| Insulation | Removable Glass Wool Wrap |
| Packing Options | Raschig Rings, Helices, or Structured Mesh (Customizable) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Arium® Smart Station |
| Configuration | Benchtop or Wall-Mounted |
| Dispensing Range | 0.1 mL to 5 L |
| Dispensing Modes | Continuous, Drop-by-Drop, Soft Start/Stop |
| Arm Adjustment | Height-adjustable (infinitely variable), 360° rotation |
| Interface | Full-color capacitive touchscreen |
| Fluid Path Materials | Pharmaceutical-grade PEEK, EPDM, and PTFE |
| Compliance | Designed for ISO 3696 Grade 1 & ASTM D1193 Type I water distribution |
| Certification | CE-marked, compliant with EU Medical Device Regulation (MDR) Annex I essential requirements for ancillary equipment |
| Brand | AYAN Instruments |
|---|---|
| Model | B80 |
| Origin | Zhejiang, China |
| Equipment Type | Laboratory-Scale Vacuum Thin-Film Evaporator |
| Application Scope | Solvent Removal, Molecular Distillation, High-Viscosity Feedstock Purification, Heat-Sensitive Compound Concentration |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | NJ-SCH-III |
| Capacity | 4000 mL |
| Distillation Rate | 100 mL/h |
| Temperature Range | Up to 180 °C (PID-controlled) |
| Construction Material | All-wetted parts in high-purity PFA |
| Cooling Method | Ambient air cooling |
| Safety Features | Dry-run protection, overheat cutoff, integrated vent hood compatibility |
| Metal Impurity Reduction | From ~10 ppb to ≤0.01 ppb (single-pass) |
| Collection Vessel | 2000 mL PFA bottle with GL45 thread seal |
| Power Supply | Standard AC input with silicone heating mantle |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SCH-I |
| Capacity | 1000 mL |
| Output Rate | 50 mL/h |
| Heating Method | Silicone Rubber Heated Jacket |
| Temperature Control | PID Digital Controller (±1 °C) |
| Power Consumption | ≤400 W (Variable Frequency Adjustable) |
| Material of Wetted Parts | High-Purity PFA |
| Cooling Method | Ambient Air Cooling |
| Liquid Level Markings | 200 / 600 / 1000 mL |
| Safety Features | Dry-run Protection, Overheat Protection |
| Compliance | Designed for ISO/IEC 17025-aligned trace metal analysis workflows |
| Collection Vessel | 1000 mL PFA Bottle (GL45 Thread, Blow-Molded, No Inner Cap Required) |
| Metal Impurity Reduction | From ~10 ppb to ~0.01 ppb after single distillation |
| Brand | CreaPhys |
|---|---|
| Origin | Germany |
| Model | DSU |
| Vacuum Level | < 10⁻⁶ mbar (clean & dry system) |
| Temperature Range | Evaporation Zone 100–600 °C, Condensation Zone 60–500 °C |
| ΔT Between Zones | > 200 °C (at 500 °C) |
| Sample Capacity | 0.5–500 g (up to 1000 g) |
| Sublimation Efficiency | up to 97% |
| Construction | Borosilicate Glass (Duran®), Stainless Steel Flanges, Viton/Kalrez Seals |
| Overall Height | ~1500–2000 mm |
| Tube Length | ~630 mm |
| Outer Tube Diameter | ~34 mm |
| Brand | CreaPhys |
|---|---|
| Origin | Germany |
| Model | DSU Series |
| Crucible Volumes | 0.5, 1, 2, 4, and 8 cm³ (custom volumes available) |
| Crucible Shapes | Conical, cylindrical, with/without central aperture |
| Crucible Materials | Al₂O₃, BN, AlN, graphite, quartz |
| Deposition Rate | 1×10⁻³ to 5 nm/s at 150 mm substrate distance (material-dependent) |
| Heating System | Tungsten coil with ceramic thermal insulation, 8 A / 60 W (size-dependent) |
| Temperature Range | 50 °C to 600 °C |
| Temperature Stability | < ±0.1 K (PID-controlled) |
| Thermocouple | Type K |
| Optional Features | Integrated safety guard, stainless-steel chamber housing |
| Brand | CreaPhys |
|---|---|
| Origin | Germany |
| Model | DSU-Metal Series |
| Crucible Volume | 1 cm³ / 2 cm³ (custom volumes available) |
| Achievable Metal Layer Thickness | >500 nm per deposition cycle at 250 mm source-to-substrate distance |
| Deposition Rate | 1 nm/s (up to 10 nm/s) at 250 mm |
| Heating System | Ceramic crucible holder with integrated metal crucible |
| Temperature Range | 300 °C to 1700 °C |
| Power Supply | <10 V (typ. 9 V), <200 A (typ. 110 A), up to 2 kW |
| Cooling Water Flow | ~15 L/min |
| Optional Configurations | Ceramic or replaceable metal crucibles |
| Brand | CreaPhys |
|---|---|
| Origin | Germany |
| Model | DSU200 |
| Maximum Batch Capacity | 200 g |
| Base Vacuum | < 10⁻⁶ mbar (clean & dry system) |
| Evaporation Zone Temp Range | 100–500 °C |
| Deposition Zone Temp Range | 100–450 °C |
| Deposition Zone Temperature Uniformity | < ±10 °C |
| Footprint Diameter | 190 mm |
| Height | ~800 mm |
| Optional Accessories | Liquid Nitrogen Cold Trap, Glovebox Integration Kit |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HDG-04 / DG-03 / DG-02 |
| Price | USD 1,380 (FOB Shanghai) |
| Channels | 2 (HDG-02), 3 (DG-03), 4 (HDG-04) |
| Degassing Efficiency | ≤1.8 ppm O₂ at 1 mL/min, ≤4.0 ppm O₂ at 5 mL/min (inlet: 8 ppm O₂, 25°C) |
| Vacuum Pressure | −0.085 MPa (absolute) |
| Max Flow per Channel | 10 mL/min |
| Solvent Volume per Channel | 12 mL |
| Dimensions (W×D×H) | 150 × 340 × 180 mm |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | 4000A |
| Pricing | Available Upon Request |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | 4100 |
| Pricing | Available Upon Request |
| Filtration Channels | 6 independent programmable channels |
| Filtration Diameter | 90 mm |
| Filter Support | 316 stainless steel perforated support plate |
| Collection Vessels | PTFE-sealed, auto-closing, volumetrically controlled receivers |
| Fluid Path Material | PTFE tubing only |
| Sample Introduction | Automated peristaltic dosing with precise volume delivery |
| Platform Motion | Motorized rotary stage with auto-engagement/disengagement mechanism |
| Cleaning Protocol | Integrated vacuum-assisted purge and rinse cycle |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CH-2000 |
| Pricing | Upon Request |
| Brand | JTONE |
|---|---|
| Origin | Guangdong, China |
| Model | AYJ-5 |
| Construction Material | Borosilicate 3.3 Glass |
| Tower Height | ≈2800 mm |
| Tower Diameter (ID) | 25 mm |
| Pot Volume | 5 L |
| Packing Effective Height | 1 m |
| Maximum Heating Temperature | 300 °C |
| Ultimate Vacuum (Open System) | ≤0.1 mbar |
| Condenser Type | Vertical |
| Heat Exchange Area | 0.2 m² |
| Reflux Ratio Control | Yes |
| Continuous Sampling Valve | Yes |
| Temperature Monitoring | Integrated Digital Display |
| Power Supply | 220 V, 50/60 Hz, Single Phase |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CENTRIFAN™ PE |
| Pricing | Available Upon Request |
| Brand | LICA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LI-2100 |
| Price | USD 30,500 (FOB Beijing) |
| Vacuum Level | <1000 Pa |
| Leak Rate | <1 Pa/s |
| Extraction Capacity | 14 samples per run |
| Throughput | >110 samples/day |
| Extraction Efficiency | >98% |
| Water Recovery Rate | 99–101% |
| Vacuum Pump | 5 L/min, 24 V DC, Max Pressure 5 mbar |
| Cooling | Compressor-coupled cryogenic trap, Min Temp −95 °C |
| Heating | Resistive cartridge heating, Max Temp 190 °C |
| Display | 7″ TFT LCD (800×480, 65K colors), touch-enabled HMI |
| Safety | Overtemperature cutoff, auto-alarm for cooling failure & vacuum breach |
| Dimensions (H×W×D) | 90 × 74 × 110 cm |
| Weight | 120 kg |
| Brand | LOEMI |
|---|---|
| Origin | Germany |
| Model | VRA-50 / VRA-150 / VRA-250 |
| Total Volume | 50 L / 150 L / 250 L |
| Operating Volume | 25–30 L / 5–100 L / 140–170 L |
| Distillation Rate (typ.) | 8–20 L/h / 25–60 L/h / 30–80 L/h |
| Max. Operating Temperature | 200 °C |
| Pressure Range | −1.0 to +0.5 bar |
| Heating | Integrated Explosion-Proof Thermal Oil System |
| Vacuum System | LOE/V6 (VRA-50) or LOE/V30 (VRA-150/250) |
| ATEX Certification | II 1/2 G c T3 per Directive 94/9/EC |
| Control | PLC-Based HMI Terminal |
| Power Supply | 400 V / 3-phase / 50 Hz |
| Total Power Consumption (avg.) | 2.9 kW / 6.0 kW / 11.0 kW |
| Dimensions (L×W×H) | 600×1420×1800 mm / 750×2000×1800 mm / 850×2000×1800 mm |
| Weight | 250 kg / 400 kg / 500 kg |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PRI-3500 |
| Quotation | Upon Request |
| Construction Material | 316 Stainless Steel (main frame) |
| Cold Trap | KF25 Glass |
| Vacuum Measurement | Dual-Sensor Compound Vacuum Gauge (Resistive: 1×10⁵ – 1×10⁻¹ Pa |
| Ionization + Resistive Composite Mode | 1×10⁵ – 1×10⁻⁵ Pa) |
| Digital Pressure Gauge Range | −0.1 to 0 MPa |
| Gas Storage Cylinders | Four 7.5-L Units |
| Overall Dimensions | 2000 mm (L) × 800 mm (W) × 2400 mm (H) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | TQ-01A |
| Display | High-resolution LCD touchscreen interface |
| Pre-heating capability | Yes, prior to degassing |
| Fluid delivery accuracy | ±1% of set volume (≥2 L) |
| Volume resolution | 0.1 L |
| Operating temperature range | 35–42 °C (heating optional) |
| Media compatibility | Deionized water, distilled water, aqueous buffers (pH 1–14, non-surfactant) |
| Degassing efficiency | 3.0–5.0 mg/L dissolved oxygen (DO) |
| Flow rate | 1.6 L/min |
| Dimensions (L×H×W) | 500 × 340 × 295 mm |
| Rated power | 1700 W |
| Heating accuracy | ±2 °C |
| Inlet filtration | Optional 40/25/20 µm stainless-steel mesh pre-filter |
| Minimum inlet fluid temperature | ≥18 °C |
| Maintenance design | Modular, tool-free component replacement |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® 5.250 |
| Maximum Flow Rate | 250 mL/min |
| Maximum Pressure | 250 bar |
| Import Category | Imported Instrument |
| Distributor Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® 5.250P |
| Maximum Flow Rate | 125 mL/min |
| Maximum Pressure | 250 bar |
| Application Focus | Complex Peptide Mixture Separation |
| Import Status | Imported Instrument |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® 5.400-UV |
| Maximum Flow Rate | 125 mL/min |
| Maximum Pressure | 400 bar |
| UV Detection | Integrated Dual-Wavelength UV/Vis Detector |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® XS 520 Plus |
| Max Flow Rate | 300 mL/min |
| Max Operating Pressure | 20 bar |
| Type | Medium-Pressure Preparative LC System |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash®5.015‐XL |
| Max Flow Rate | 825 mL/min |
| Max Operating Pressure | 15 bar |
| Scale | Process to Kilo-Lab (up to 1–5 kg purified material per run) |
| Compliance | CE, ISO 9001-certified manufacturing |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash®535-XL |
| Max Flow Rate | 400 mL/min |
| Max Pressure | 35 bar |
| Import Status | Imported Instrument |
| Distributor Type | Authorized General Distributor |
| Pricing | Upon Request |
| Brand | Rocker |
|---|---|
| Origin | Taiwan |
| Model | WelVac200 |
| Housing Material | Anodized Aluminum |
| Collection Tray Material | Polycarbonate (PC) |
| Sealing Gasket & O-Rings | Silicone Rubber |
| Luer Connectors | Silicone |
| Compatible Tubing ID | 8 mm (5/16") |
| Dimensions (Internal) | 128 × 86 × 73 mm (L×W×H) |
| Dimensions (External) | 232 × 124 × 102 mm (L×W×H) |
| Net Weight | 2.6 kg |
| Gross Weight | 3.0 kg |
| Warranty | 2-Year Parts Coverage |