| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Super LIX-R |
| Price | Upon Request |
| Temperature Range (°C) | 0–50 |
| Heating/Cooling Rate (°C/min) | 0.01–1.5 |
| Temperature Accuracy (°C) | ±0.1 |
| Sample Diameter (mm) | Φ5 ±0.5 |
| Sample Length (mm) | 12–20 |
| Measurement Range (µm) | 20 |
| Resolution (nm) | <0.2 |
| CTE Detection Limit | 5 × 10⁻⁹ K⁻¹ |
| Thermal Stability | <±0.001 °C/min at 0.1 °C/min ramp |
| Atmosphere | Low-pressure He (100 Pa) |
| Sensor | PT-100 Platinum RTD (JIS C 1604-1997 Class A) |
| Laser | He-Ne, 632.8 nm, 5 mW (IEC 60825-1 Class 3B) |
| Brand | Aiyao Instruments |
|---|---|
| Model | TEA |
| Measurement Principle | Optical Interferometry |
| Sample Type | Transparent Bulk & Thin-Film Materials |
| Heating Method | IR Heater with PID + Fuzzy Logic Control |
| Temperature Control Mode | Programmable Ramp & Isothermal Hold |
| Vacuum Port | Yes |
| Cooling Interface | Water-Cooled Heat Exchanger & Optional Cryogenic/Gas Purge Connection |
| Origin | Hubei, China |
| Distributor Type | Authorized Domestic Distributor |
| Compliance | Designed for ISO 11359-2 and ASTM E228 Conformance Context |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | CTE-360 |
| Temperature Range | –25 °C to +100 °C |
| Compliance | ASTM D696, ASTM E228 |
| Sample Max Cross-Section | 12.5 mm (0.5 in) |
| Recommended Sample Length | 50 mm (2 in) |
| CTE Accuracy | ±3% (full 100 °C range) |
| Power Supply | 100–230 VAC, 50/60 Hz, ≤400 W |
| Dimensions | 43 × 43 × 43 cm (17 × 17 × 17 in) |
| Weight | 9 kg (20 lb) |
| Software | WinCTE v1.x (Windows 7–11, 32/64-bit) |
| Brand | AYAO Instruments |
|---|---|
| Origin | Hubei, China |
| Model | OPA |
| Type | Optical Power-Based Thermal Dilatometer & Phase Transition Analyzer |
| Measurement Principle | Optical Interferometry (for thermal expansion) + Reflectance Power Monitoring (for phase transition) |
| Sample Form | Free-standing films, substrate-supported thin films, bulk materials |
| Minimum Film Thickness | 1 nm |
| Non-Destructive Testing | Yes |
| Dual-Parameter Output | Coefficient of Thermal Expansion (CTE) and Phase Transition Temperature (e.g., crystallization, melting, glass transition) |
| Compliance Context | Designed for R&D environments requiring traceable, repeatable thermal property data in accordance with ISO 11359 (thermomechanical analysis), ASTM E831 (linear thermal expansion), and GLP-aligned data integrity practices |
| Brand | CRYOALL |
|---|---|
| Origin | Beijing, China |
| Model | C15V-Pro |
| Temperature Range | −263 °C to RT (10 K to ~25 °C) |
| Heating Rate | 0–50 K/min |
| Temperature Accuracy | ±0.1 K |
| Sample Length | ≤50 mm |
| Measurement Range | 0–5000 µm |
| Resolution | 0.125 nm |
| Atmosphere Options | Vacuum (1×10⁻⁵ mbar), O₂, N₂, Ar, He, H₂, forming gas |
| Contact Force | 0.01–2.5 N (motorized, programmable) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DIL0806 A/B |
| Price Range | USD 7,000–14,000 |
| Temperature Range | RT to 1000 °C |
| Heating Rate | 0–20 °C/min |
| Temperature Accuracy | ±1 °C |
| Max. Sample Length | 50 mm |
| Stroke Range | 5 mm |
| Measurement Resolution | 0.1 µm |
| Atmosphere Options | Air, Reducing, Inert |
| Brand | Guance Instruments |
|---|---|
| Model | GCDZY-I2 |
| Temperature Range | 200 °C |
| Heating Rate | 0–200 °C/min |
| Temperature Accuracy | ±2 °C at 200 °C |
| Sample Chamber Dimensions | Ø68 mm × 120 mm (ID × height) |
| Tumbling Speed | 90 rpm |
| Tumbling Duration | Programmable |
| Steel Ball Diameter | 6 mm |
| Power Rating | 1 kW |
| Supply Voltage | 220 V / 50 Hz |
| Overall Dimensions | 700 × 640 × 690 mm (L×W×H) |
| Net Weight | 50 kg |
| Compliance | YS/T 63.11–2006, YS/T 63.12–2006 |
| Atmosphere Capability | Ambient air or inert gas (N₂, Ar) – configurable via external gas inlet |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GCRPZ-1000 |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | 0.1–10 K/min (adjustable) |
| Temperature Accuracy | ±1 °C |
| Sample Dimensions | Max. 50 mm length × 8 mm diameter |
| Measurement Range | ±5 mm |
| Resolution | 0.1 µm |
| Atmosphere Options | N₂, Ar, inert gases, vacuum (–0.1 MPa) |
| Sensor Type | Optical Grating Displacement Transducer |
| Sample Holder Material | Fused Quartz |
| Power Supply | 220 V ±10%, 50 Hz |
| Cooling Requirement | External recirculating chiller (max. 100 °C bath temp, ≤2 kW heating power) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCRPZ-1000.2 |
| Price | USD 1,700 (FOB) |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | 0.1–10 K/min (programmable) |
| Temperature Accuracy | ±1 °C |
| Sample Dimensions | Max. 50 mm length × 8 mm diameter |
| Measurement Range | ±5 mm |
| Resolution | 0.1 µm |
| Atmosphere Options | N₂, Ar, inert gas, vacuum (−0.1 MPa) |
| Sample Holder Material | Fused quartz |
| Power Supply | 220 V ±10%, 50 Hz |
| Cooling Requirement | External water chiller (max. 100 °C inlet, ≤2 kW heating power) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCTKP-700 |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable, up to 10 °C/min (typical) |
| Temperature Accuracy | ±1 °C (after thermal equilibrium) |
| Displacement Range | 0–1 mm |
| Displacement Resolution | ±0.001 mm |
| Sample Dimensions | (i) Ø50 mm × 60 mm |
| Atmosphere Control | Pressure range 0–50 kPa (gauge), compatible with inert, reducing, or vacuum environments |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 1.7 kW |
| Thermal Sensor | K-type thermocouple (0–1000 °C, Class 0.1 accuracy) |
| Gas Flow Control | 0–80 L/min (mass flow controller) |
| Instrument Dimensions | 700 × 810 × 1150 mm (W × D × H) |
| Net Weight | 150 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCTKP-700b |
| Price | USD 1,280 (FOB Beijing) |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable, 0.1–10 °C/min (standard configuration) |
| Temperature Accuracy | ±1 °C (after thermal equilibrium, per ASTM E228 calibration protocol) |
| Displacement Range | 0–1 mm |
| Measurement Resolution | ±0.001 mm |
| Sample Dimensions | (i) Ø50 mm × 60 mm cylindrical |
| Atmosphere Control | Pressure range 0–50 kPa (gauge), compatible with inert (N₂, Ar), reducing (5% H₂/95% N₂), or vacuum conditions |
| Power Supply | 220 V AC / 50 Hz / 1.7 kW |
| Thermocouple | Type K, 0–1000 °C, Class 0.1 accuracy |
| Gas Flow Control | Mass flow controller, 0–80 L/min |
| Dimensions (W×D×H) | 700 mm × 810 mm × 1150 mm |
| Net Weight | 150 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCTKP-700C |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable (0–10 °C/min typical) |
| Displacement Range | 0–1 mm |
| Displacement Resolution | ±0.001 mm |
| Sample Dimensions | Ø50 mm × 60 mm or ≥5 mm cross-section × ≥50 mm length |
| Atmosphere Control | 0–50 kPa (gauge), compatible with inert/N₂/air/vacuum |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 1.7 kW |
| Thermocouple | Type K (0–1000 °C, Class 0.1 accuracy) |
| Gas Flow Meter | 0–80 L/min |
| Dimensions (W×D×H) | 810 × 700 × 1150 mm |
| Weight | 150 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCTKP-700H |
| Price | USD 1,280 (FOB Beijing) |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable, 0.1–20 °C/min (standard) |
| Temperature Accuracy | ±1 °C (after stabilization, per ASTM E228 calibration protocol) |
| Displacement Range | 0–1 mm |
| Measurement Resolution | ±0.001 mm |
| Sample Dimensions | (i) Ø50 mm × 60 mm cylindrical |
| Atmosphere Control | Pressure range 0–50 kPa (gauge), compatible with inert (N₂, Ar), oxidizing (air), or reducing (5% H₂/95% N₂) environments |
| Power Supply | 220 V AC, 50 Hz, 1.7 kW |
| Thermocouple | Type K, 0–1000 °C, Class 0.1 accuracy |
| Gas Flow Control | Digital mass flow controller, 0–80 L/min |
| Unit Dimensions | 700 × 810 × 1150 mm (W × D × H) |
| Net Weight | 150 kg |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GYH-A |
| Quotation | Available Upon Request |
| Operating Temperature Range | Up to 800 °C (short-term max 1000 °C) |
| Heating Rate | 0–30 °C/min |
| Temperature Uniformity & Stability | ±2 °C at setpoint |
| Rated Power | 10 kW |
| Electrical Supply | 380 V, 50 Hz, 50 A |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HPY-3 |
| Temperature Range | Ambient to 1600 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Sample Chamber Dimensions | 600 × 400 × 300 mm |
| Expansion Measurement Range | ±5 mm |
| Resolution | 1 µm |
| Atmosphere Options | Inert gas (N₂, Ar), Vacuum (up to 0.1 MPa) |
| Compliance | GB/T 3810.9 & GB/T 3810.10–1999 |
| Brand | Huafeng |
|---|---|
| Origin | Hunan, China |
| Model | DIL0806A-1400 |
| Temperature Range | RT to 1400 °C |
| Heating Rate | 0–20 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Displacement Resolution | 0.1 µm |
| Atmosphere Options | Vacuum and Controlled Gas |
| Sample Holder Material | Alumina |
| Maximum Displacement Range | 5000 µm |
| Sample Dimensions | Ø5–8 mm × 25–50 mm (cylindrical or rectangular) |
| Thermal Expansion Coefficient Resolution | 0.001 × 10⁻⁶ K⁻¹ |
| System Measurement Uncertainty | ±0.1% |
| Interface | USB 2.0 |
| Compliance | ASTM E831, ASTM D696, ASTM D3386, DIN 51045 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | PCY-SL-30 |
| Price Range | USD 1,400–7,000 |
| Temperature Range | −30 °C to 30 °C |
| Heating Rate | 5 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Sample Diameter | 6–10 mm |
| Measurement Range | 5 mm |
| Resolution | 1 µm |
| Atmosphere Options | Air, Vacuum, Inert Gas |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L74 HM |
| Temperature Range | –100 °C to 500 °C (RT–500 / 1000 / 1500 / 2000 °C) |
| Heating Rate | 0.01–100 °C/min (dependent on furnace configuration) |
| Field of View | 10 × 14 mm² |
| Measurement Resolution | up to 1 µm |
| Atmosphere Options | inert, reducing, oxidizing, vacuum (optional) |
| Vacuum Level | 10⁻⁵ mbar |
| Compliance Standards | DIN 51730, ISO 540, CEN/TS 15404, ASTM D1857, BS 1016-15, CEN/TS 15370-1, IS 12891, NF M03-048 |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L74 OD |
| Temperature Range | -100 to 2000 °C |
| Heating Rate | 0.01–100 °C/min (dependent on furnace configuration) |
| Field of View | 3.3 × 2.8 mm² |
| Measurement Resolution | 1 µm |
| Atmosphere Options | Oxidizing (optional: reducing, inert, vacuum) |
| Vacuum Level | 10⁻⁵ mbar |
| Compliance Standards | ASTM D1857, ISO 540, DIN 51730, CEN/TS 15370-1, BS 1016-15, NF M03-048, CEN/TR 15404, IS 12891 |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L75 Horizontal / Vertical |
| Temperature Range | −263 °C to 2800 °C |
| Displacement Range | ±2500 µm and ±25000 µm |
| Resolution | 0.03 nm (LVDT) and 0.1 nm (optical encoder) |
| Atmosphere Control | Manual gas dosing or mass flow controllers for 1, 3, or multiple gases |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L75 HP |
| Temperature Range | RT to 1100 °C / RT to 1400 °C / RT to 1800 °C |
| Maximum Pressure | 100 bar / 150 bar (configurable) |
| Vacuum Level | 1×10⁻⁴ mbar |
| Sample Length | up to 50 mm |
| Sample Diameter | φ7 / φ12 / φ20 mm |
| Measurement Range | 500 µm / 5000 µm |
| Resolution | 0.125 nm |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing, Vacuum |
| Optional Accessories | Steam Generator, Mass Flow Controlled Gas Mixing System (MFC), QMS/FTIR Coupling Interface |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L75 Laser |
| Temperature Range | −180–500 °C |
| Heating/Cooling Rate | 0.01–50 K/min |
| Sample Length | up to 20 mm |
| Sample Diameter | up to φ7 mm |
| Measurement Resolution | 0.3 nm |
| Atmosphere Options | inert, oxidizing, reducing, vacuum |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L75 Nuclear |
| Temperature Range | −263 to 2800 °C |
| Measurement Range | ±2500 µm |
| Delta L Resolution | 0.03 nm |
| Atmosphere Control | Manual gas dosing or mass flow controller (1, 3, or multi-gas capability) |
| Contact Force Range | 10 mN – 5 N |
| Vacuum Compatibility | Yes |
| Dual/Triple Furnace Configuration | Up to 3 furnaces |
| Glovebox-Compatible Mechanical–Electrical Separation | Optional |
| Low-Temperature Accessory | LN₂ cryostat & internal cooler |
| Softening Point Detection | Yes |
| Density Determination Module | Yes |
| Optical Encoder L-DTA Option | Up to 2000 °C (0.1 nm resolution) |
| Rate-Controlled Sintering (RCS) | Yes |
| Auto Sample Length Detection | Yes |
| Thermostatic Probe | Yes |
| Vacuum Sealing | Yes |
| Automatic Evacuation System | Optional |
| Electric Furnace Option | Optional |
| OGS Deoxygenation System | Optional |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L75 Quattro |
| Temperature Range | −180 to 500/700/1000 °C |
| Heating/Cooling Rate | 0.01–50 K/min (dependent on furnace configuration) |
| Sample Length | ≤50 mm |
| Sample Diameter | ≤7 mm |
| Measurement Range | 500 / 5000 µm |
| Resolution | 1.25 nm |
| Atmosphere | Inert, oxidizing, reducing, vacuum (static/dynamic) |
| Furnace Options | Multi-furnace modular system |
| Sensor Architecture | Four independent high-precision linear variable differential transformers (LVDTs) |
| Zero-Point Calibration | Fully automated per channel |
| Interface | Integrated electronics with USB connectivity |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L76 PT |
| Temperature Range | RT to 1600 °C |
| Measurement Range | ±2500 µm |
| Delta L Resolution | 0.05 nm |
| Contact Force | Manually adjustable up to 3 N |
| Sensor Type | High-precision LVDT (Linear Variable Differential Transformer) |
| Furnace Options | Quartz (up to 1100 °C), Al₂O₃ (up to 1600 °C) |
| Software | LINSEIS Thermal Analysis Suite with CTE calculation, softening point detection, and automated cooling trigger |
| Compliance | Designed for GLP-compliant thermal property characterization in industrial QC and R&D labs |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DIL L78 RITA |
| Temperature Range | −150 °C to 1600 °C |
| Heating/Cooling Rate | up to 2500 °C/s (induction furnace, hollow cylindrical sample) |
| Sample Geometry | Hollow cylinder, OD 3.5 mm / ID 3 mm / L 10 mm |
| Measurement Range | ±1.2 mm |
| Resolution | 5 nm |
| Data Acquisition Rate | up to 1 kHz |
| Compliance | ASTM A1033 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | AY-8 |
| Temperature Range | 0–999 °C |
| Heating Rate Accuracy | ±30 s/24 h |
| Temperature Accuracy | ±1 °C |
| Sample Chamber Dimensions | 330 × 290 × 120 mm |
| Timing Range | 0–999 min |
| Temperature Resolution | 1 °C |
| Atmosphere | Oxidizing (Air) |
| Power Consumption | ≤5 kW |
| Thermocouple Class | 0.5 grade |
| Time Resolution | 0.1 min |
| Preheating Options | Three selectable preset temperatures |
| Recovery Performance | Furnace returns to pre-insertion temperature within 7 min |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PZD-8 |
| Price | USD 980 (FOB) |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | Reaches (820 ± 5) °C within 2.5 min |
| Temperature Accuracy | ±3 °C (per ASTM D5867 / GB/T 5448-2014) |
| Sample Mass | 1 g |
| Timing Range | 0–999 min (99 min 59 s) |
| Temperature Resolution | 1 °C |
| Time Resolution | 1 min |
| Time Accuracy | ±30 s per 24 h |
| Atmosphere | Air |
| Power Consumption | ≤1000 W |
| Thermocouple Type | Dual K-type |
| Control Precision | Class 0.5 (IEC 60584-2) |
| Furnace Insulation | Alumina-silica fiber blanket |
| Heating Element | Resistance wire (Fe-Cr-Al alloy) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Classic |
| Temperature Range | RT to 1600 °C |
| Heating Rate | 0–50 °C/min |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±5000 µm |
| Resolution | 2 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Classic |
| Temperature Range | RT to 1600°C |
| Heating Rate | 0.001–50°C/min |
| Temperature Accuracy | ±0.1°C |
| Sample Length | 25–50 mm |
| Atmosphere Control | Integrated MFC (1 standard, up to 3 optional) |
| Vacuum Capability | Sealed vacuum chamber (optional auto-vacuum) |
| Force Control | Programmable contact force with stepwise or linear ramping |
| Displacement Resolution | 2 nm (NanoEye optical encoder) |
| 炉体配置 | Single-furnace integrated design |
| Compliance | ASTM E228, ISO 11359-1/-2, DIN 51045, USP <671> |