Flow Injection Analyzer
Filter
Showing 1–30 of 93 results
| Brand | AMS Alliance |
|---|---|
| Model | FUTURA |
| Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥100 positions |
| Reagent Positions | ≥100 |
| Flow Cell Path Length | 15–50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Analysis Rate | 15–120 samples/hour |
| Sample Volume | 0.5–100 µL |
| Peristaltic Pump | 13 rollers per channel |
| Flow Rate Range | 50–3000 µL/min |
| Linear Absorbance Range | 0–2.5 AU |
| Dimensions | 240 × 650 × 410 mm |
| Weight | 17 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥100 positions |
| Reagent Positions | 1–20 |
| Flow Cell Pathlength | 15–50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | FUTURA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 200 positions / 5 racks |
| Reagent Positions | 104 or 360 |
| Flow Cell Path Length | 50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 104-position turntable autosampler (optional 360-position XYZ autosampler) |
| Reagent Positions | 36 |
| Flow Cell Path Length | 50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Detection Limit | Sub-ppb level |
| Throughput | Up to 120 samples/hour |
| Pump Tubing | 52 channels (2 × 26) |
| Flow Rate Range | 50–3000 µL/min |
| A/D Resolution | 24-bit (1.68 × 10⁷) |
| Dimensions (Main Unit) | 75 × 50 × 42 cm |
| Weight (Main Unit) | 45 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMAs |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Volume | 0.5 mL |
| Reagent Positions | 104 |
| Flow Cell Path Length | 5–50 mm |
| Light Source | Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | SmartChem 200 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Test | 300 µL |
| Sample Positions | 126 |
| Reagent Positions | 200 (including refrigerated slots) |
| Cuvette Path Length | 10 mm |
| Light Source | LED and Halogen Tungsten Lamp (6 V / 10 W, 2000 h lifetime) |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem 450 |
| Sample Capacity | 100 positions (standard configuration) |
| Reagent Positions | 72 (with optional refrigeration) |
| Wavelength Range | 340–880 nm |
| Cuvette Path Length | 6 mm |
| Light Source | 6 V / 10 W halogen lamp |
| Throughput | up to 450 determinations per hour (including ISE module) |
| Absorbance Range | 0.001–4.200 Abs |
| Resolution | 0.0001 Abs |
| Temperature Control | 37 °C ± 0.3 °C |
| Dimensions | 500 × 700 × 1050 mm (H × W × L) |
| Weight | 48 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem 600 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 |
| Cuvette Pathlength | 6 or 10 mm |
| Light Source | LED |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | Smartchem 600 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Cup | 300 µL |
| Sample Capacity | 126 positions |
| Reagent Positions | 600 |
| Cuvette Path Length | 10 mm |
| Light Source | LED and Halogen Lamp |
| [Brand | AMS Alliance |
|---|---|
| Origin | USA |
| Model | Smartchem 600 |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 (with refrigeration) |
| Wavelength Range | 340–1100 nm |
| Cuvette Path Length | 10 mm (6 mm optional) |
| Detection Principle | Dual-beam, dual-wavelength photometry |
| Maximum Throughput | 600 samples/hour |
| Reaction Disc Capacity | 85 reusable cuvettes |
| Temperature Control | 37 °C ± 0.3 °C |
| Linear Absorbance Range | 0.00001–4.2 Abs |
| Resolution | 0.00001 Abs |
| Minimum Reaction Volume | 180 µL |
| Compliance | ISO, AOAC, US EPA, AFNOR, COFRAC, BATF] |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | Smartchem140 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 330–840 nm |
| Sample Capacity | 64 positions |
| Reagent Positions | 24 + 10 |
| Cuvette Path Length | 6 mm |
| Light Source | Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem200 |
| Product Type | Automated Discrete Analyzer |
| Wavelength Range | 420–880 nm |
| Sample Capacity | 126 positions |
| Reagent Positions | 10 (expandable to 28) |
| Cuvette Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Tungsten Lamp (2000 h lifetime) |
| Measurement Speed | Up to 200 tests/hour (per method) |
| Minimum Reaction Volume | 300 µL |
| Absorbance Range | 0.001–2.500 Abs |
| Absorbance Resolution | 0.0001 Abs |
| Thermostat Accuracy | 37 °C ± 0.3 °C |
| Dimensions (H×W×L) | 420 × 650 × 1000 mm |
| Weight | 43 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | Smartchem600 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 12 fixed wavelengths from 340 to 880 nm |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 |
| Cuvette Path Length | 6 mm or 10 mm |
| Light Source | High-stability LED |
| Brand | AMS |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FUTURA Segmented Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 240–720 positions |
| Reagent Positions | 5–30 |
| Flow Cell Path Length | 5–500 mm |
| Light Source | Tungsten-Halogen Lamp |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smartchem 300 |
| Pricing | Upon Request |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-1000 |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 162 positions |
| Reagent Positions | 3–8 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | AutoChem 1100 |
| Price Range | USD 28,000–70,000 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–900 nm |
| Sample Capacity | 60 or 96 positions |
| Reagent Positions | 27 (Peltier-cooled) |
| Cuvette Path Length | 10 mm |
| Light Source | 12 V / 20 W Halogen Lamp with UV-Visible Output |
| Detection Speed | Up to 200 determinations per hour |
| Injector Precision | ±0.5% (5–1000 µL), Resolution: 0.1 µL |
| Reaction Disc Temperature Control | ±0.1 °C |
| Cuvette Temperature Control | ±0.1 °C |
| Photometric Accuracy | ±1% OD (0–2.5 OD) |
| Linearity | <0.5% deviation |
| Noise | <±0.002 Abs (at 340 nm, 2.5 OD) |
| Detection Modes | Endpoint, Differential, Timed, and Kinetic |
| Data Interface | RS-232 / USB |
| Operating Environment | 15–35 °C, 20–80% RH |
| Power Supply | 220 V AC |
| Brand | Bode Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDCFA-800 |
| Pricing | Available Upon Request |
| Instrument Type | Continuous Flow Analyzer |
| [Brand | Boode |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDFIA-210 |
| Pricing | Upon Request] |
| Brand | Brookdale |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | BDFIA-7000 |
| Pricing | Upon Request |
| Brand | Brookdale Instruments |
|---|---|
| Model | BDFIA-9000 |
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Pricing | Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | BDFIA-100 |
| Pricing | Available upon Request |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDFIA-8000 |
| Pricing | Upon Request |
| Instrument Type | Flow Injection Analyzer |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDFIA-8000 |
| Price | Upon Request |
| Instrument Type | Flow Injection Analyzer |
| Wavelength Range | 200–900 nm |
| Sample Rack Capacity | 10-position or 40-position options |
| Reagent Positions | 11 |
| Flow Cell Path Length | 10 mm |
| Light Source | 5 V Halogen Lamp |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDFIA-8600/C |
| Product Type | Flow Injection Analyzer |
| Design | Integrated Channel-Based FIA System |
| Detection Principle | Coupled Online Sample Pretreatment + UV-Vis Spectrophotometry |
| Automation Level | Fully Automated, Computer-Controlled Sequential Analysis |
| Safety Features | Real-time Leak Detection, Waste Container Overflow Alarm, Liquid-Level Tracking Sensors |
| Compliance Context | Designed to support ASTM D3370, ISO 15681-2, EPA Method 354.1, and GB/T 5750–2023 workflows |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380Plus |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | Cleverchem 380Plus |
| Sample Capacity | 119 positions (expandable to 129) |
| Reagent Positions | 49 |
| Wavelength Range | 400–900 nm |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Detection Principle | Photometric Colorimetry (Discrete Flow Analysis) |
| Maximum Throughput | 350 samples/hour |
| Sample Volume Range | 1–900 µL |
| Reagent Volume Range | 1–450 µL |
| Dilution Factor | Up to 100× (in-cuvette) |
| Cuvette Material | Fused Quartz (64-position carousel) |
| Cleaning | 8-step Ultrasonic + WECO Peristaltic Pump System |
| Compliance | ASTM, ISO, EPA, and GB methods |
| Software | GLP-compliant with audit trail, sample/blank correction, and 21 CFR Part 11-ready configuration options |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
