| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | FTA-8 |
| Display | 7-inch full-color TFT touchscreen (800×480 resolution, RS232 interface, FPGA-driven, zero boot time) |
| Combustion Chamber Dimensions | 660 mm × 660 mm × 1065 mm (L×W×H) |
| Flame Height Adjustment Range | 150–180 mm |
| Fuel Consumption Rate | 2.55 ± 0.15 mL/min |
| Flame Temperature Verification | 960 ± 60 °C at 50 mm from burner orifice (validated via 0.71 mm bare copper wire melt test within 6 s) |
| Timing Accuracy | ±0.1 s for both ignition and afterflame/afterglow duration |
| Repeatability Error | ±0.1 s |
| Fuel Composition | 5% (v/v) methanol + 95% (v/v) ethanol (user-prepared) |
| Construction | Electrostatically painted steel enclosure |
| Data Management | Internal storage (1 GB), historical test recall, automatic timing for ignition, flame-on, and afterflame/afterglow phases |
| Compliance Standards | MT 914–2008, GB 16413–2009, MT 113–1995 |
| Power Supply | 220 V ±10%, 50 Hz, 100 W |
| Ventilation Requirement | Mandatory fume hood or integrated exhaust & purification system |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTA-8 |
| Price Range | USD 3,500 – 7,000 |
| Application Field | Fire-Retardant Coatings |
| Test Objects | Plastics, Woven & Nonwoven Textiles |
| Repeatability Error | ±0.1 s |
| Compliance Standard | GB 14645–2014 (Equivalent to ISO 14054 for 45° flammability testing) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | GBFS-1 |
| Supply Voltage | 220 V ±10%, 50 Hz |
| Power Consumption | 180 W |
| Temperature Range | 800 ±30 °C (max 900 °C, Class 1 accuracy) |
| Temperature Stabilization Time | <3 min |
| Flame Source | Dual LPG burners (inner diameter Φ9.5 ±0.5 mm, length ~100 mm |
| Gas Flow Control | 100–1000 mL/min |
| Load Application | 7, 10, 12, 15, 17, or 20 N (equivalent to 0.75–2.04 kgf) |
| Specimen Dimensions | 300 mm × 50 mm, with two 25-mm-offset suspension holes |
| Test Duration Resolution | 0.1 s |
| Repeatability Error | ±0.1 min |
| Ignition | Automatic electronic ignition |
| Temperature Monitoring | Dual thermocouples positioned 5 mm from specimen surface |
| Data Display | Digital real-time readout of temperature and elapsed time |
| Compliance Standard | GB/T 9775–2008 (identical to ISO 6308:1980) |
| Enclosure Dimensions | 700 × 300 × 600 mm (W×D×H) |
| Weight | ~30 kg |
| Ventilation Requirement | Mandatory fume extraction via ducted hood or integrated smoke treatment system |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | GWA-10 |
| Price Range | USD 3,500 – 7,200 |
| Application Fields | Wire & Cable |
| Test Objects | Electrical Insulation Materials, Engineering Plastics |
| Repeatability Error | ±0.1 s |
| Primary Function | Glow-Wire Ignitability Testing (GWIT/GWFI) |
| Glow-Wire Temperature Range | 500–1050 °C ±2 °C |
| Glow-Wire Duration | 0–999.9 s ±0.1 s |
| Ignition Time & Extinction Time Measurement | 0–999.9 s ±0.1 s (auto-recorded, manual pause enabled) |
| Glow-Wire Specification | Ø4 mm Ni80/Cr20 alloy wire |
| Applied Force | 0.95 ±0.1 N |
| Penetration Depth | 7 ±0.5 mm |
| Linear Actuation Speed | 14 mm/s |
| Thermocouple | Ø1 mm imported K-type armored thermocouple |
| Test Chamber Volume | ≥0.5 m³ (standard) |
| Background Illuminance | ≤20 lux (black background) |
| Power Supply | 220 V ±10%, 50 Hz, 500 W |
| Net Weight | ~100 kg |
| Footprint | 1160 mm (W) × 600 mm (D) × 1310 mm (H) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RSJF-2 |
| Application Field | Electrical Wires and Cables |
| Test Object | Bundled Wire and Cable Assemblies |
| Primary Function | Fire Performance Evaluation per GB/T 31248–2014 and GB/T 18380.31–2008 (IEC 60332-3-10:2000 IDT) |
| Structural Dimensions (Overall Installation Space) | 2500 mm (W) × 4500 mm (D) × 5500 mm (H) |
| Net Weight | ~2500 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 7 kW |
| Cooling Water Requirement | Continuous supply with dedicated drainage |
| Fuel Source | Industrial propane with regulated flow (≥300 L/min compressed air via 3 kW air compressor) |
| Exhaust Handling | Integrated smoke collection and wet-scrubbing system compliant with local emission regulations |
| Safety Infrastructure | Requires 5-ton forklift, overhead crane, and three 5-m-height scaffolds for installation |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | VFT-3 |
| Applicable Standard | GB/T 18380.11–2022, GB/T 18380.12–2022, IEC 60332-1/2 |
| Flame Power | 1 kW |
| Flame Angle | 45° |
| Timing Resolution | ±0.1 s (0–999.9 s) |
| Repeatability Error | ±0.1 s |
| Gas Supply | 95% propane (LPG-compatible) |
| Power Supply | AC 220 V / 50 Hz |
| Enclosure Material | Electrostatically Painted Steel Plate |
| Dimensions (W×D×H) | 720 × 580 × 1680 mm |
| Brand | Aerospace ZHONGHENG |
|---|---|
| Model | VFT-1 |
| Origin | Beijing, China |
| Compliance | UL 2556-2021, UL 1581-2020 (Sections 1060, 1080, 1090, 1100) |
| Dimensions (Integrated) | 2400 × 1000 × 2800 mm |
| Combustion Chamber | 2360 × 980 × 1800 mm |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Rated Power | 200 W |
| Thermocouple Range | 0–1300 °C, Ø1 mm |
| Bunsen Burner Inner Diameter | Φ9.5 mm |
| Fuel | 95% Methane |
| Ignition Time Range | 0–999.9 s |
| Afterflame Time Measurement Range | 0–999.9 s |
| Timing Resolution | 0.1 s |
| Burner Tilt Angle | 0°–45° adjustable |
| Weight | ≈350 kg |
| Repeatability Error | ±0.1 s |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZRS-2 |
| Temperature Range | 500–1000 °C ±2 °C |
| Glow-Wire Duration | 0–999.9 s ±0.1 s |
| Ignition Time & Flame-Out Time Measurement | 0–999.9 s ±0.1 s |
| Thermocouple | Φ0.5 mm K-type armored |
| Glow-Wire Material | Ni80/Cr20 alloy wire, Φ4 mm |
| Penetration Depth | 7 mm ±0.5 mm |
| Applied Force | 1.0 N ±0.2 N |
| Actuation Speed | 14 mm/s |
| Repeatability Error | ≤1% |
| Compliance | GB/T 5169.10–2017, GB 4706.1, IEC 60695-2-10/11/12/13 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZY-2 |
| Application Field | Electrical & Electronic Equipment |
| Sample Type | Solid Materials |
| Repeatability Error | <1% |
| Compliance Standards | GB 4706.1-2005, GB/T 5169.5-2008, IEC 60695-11-5 |
| Flame Dimensions | Inner Diameter 0.5 mm ± 0.1 mm, Outer Diameter ≤ 0.9 mm, Length ≥ 35 mm |
| Flame Height | 12 mm ± 1 mm |
| Ignition Gas | 95% Butane (LPG compatible) |
| Flame Application Time | 0–999.9 s ± 0.1 s |
| Afterflame Time Measurement | 0–999.9 s ± 0.1 s, auto-recorded |
| Specimen Holder Positioning | Motorized X/Y/Z adjustment via touchscreen |
| Control System | PLC + 7-inch color touchscreen HMI |
| Combustion Chamber Volume | > 0.5 m³ (900 × 590 × 1050 mm) |
| Background Illuminance | ≤ 20 lux |
| Chamber Interior Finish | Matte black |
| Optional Accessories | Flame temperature calibration kit (K-type thermocouple, 0–1000 °C), gas leak alarm system |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | M233F |
| Application | Textile and Automotive Interior Materials |
| Compliance Basis | ASTM D5132, ISO 3795, FMVSS 302, DIN 75200, JIS D1201 |
| Chamber Construction | Sealed stainless steel combustion chamber with borosilicate observation window |
| Burner Type | Door-mounted Bunsen-type burner |
| Ignition Method | Manual or optional automatic spark ignition |
| Timing Control | Manual stopwatch interface or programmable digital timer (optional) |
| Gas Supply | Regulated propane or butane (user-supplied, certified grade) |
| Sample Holder | Precision-machined horizontal specimen clamp with adjustable positioning |
| Safety Features | Interlocked access door, flame-out detection, ventilation interlock |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | M233HVU |
| Chamber Volume | >0.75 m³ |
| Construction | Stainless Steel with Matte Black Interior |
| Viewing Window | Sliding Safety Glass (Large-Area, Unobstructed) |
| Gas Control System | Electromagnetic Solenoid Valve, Adjustable Pressure Regulator, Air Flowmeter, Gas Flow Meter |
| Timing System | Three Independent Digital Timers (0.1 s Resolution), Remote Start/Reset Functionality |
| Exhaust | Variable-Speed Exhaust Fan with Throttle Valve |
| Compliance Accessories | ASTM D5207 Burn Verification Kit |
| Sample Holder | Fully Adjustable Mechanical Fixture |
| Internal Illumination | Integrated LED Lighting |
| Inlet Port | Manual Iris-Type Sealed Access Port |
| Safety Features | Interlocked Door Monitoring, Flame-Resistant Sealing Gasket, Thermal Insulation Layer |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Model | Code 1005705 |
| Construction | Benchtop stainless steel test chamber with integrated fume extraction system |
| Flame Calibration | Compliant with ASTM D 5207 for 20 mm and 125 mm flame verification |
| Gas Supply | Methane feed panel with precision flowmeter, adjustable valve, and pressure gauge |
| Operator Interface | Dual hand-access ports with front-opening tempered glass viewing panels |
| Safety Integration | Built-in fume aspirator with foot-pedal activation |
| Compliance | Designed for UL 94 HB, V-0, V-1, V-2, 5VA, 5VB, VTM-1, and VTM-2 test protocols |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BFT |
| Pricing | Available Upon Request |
| Compliance | ASTM D4151 |
| Construction | Stainless Steel Enclosure with Tempered Glass Viewing Window |
| Ignition Source | No. 18 Needle Burner (Adjustable Flame Height) |
| Timing Resolution | 0.01 s |
| Accessories | Standardized Brushing Device, Sample Holder Assembly, Stainless Steel Specimen Clamps |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | FD |
| Temperature Range | Ambient + 5 °C to 300 °C |
| Internal Volume | 20 L (FD 23) |
| External Dimensions (W×H×D) | 435 × 495 × 520 mm |
| Internal Dimensions (W×H×D) | 222 × 330 × 300 mm |
| Net Weight | 27 kg |
| Heating Technology | PAT.line™ Preheating Chamber |
| Air Circulation | Adjustable forced convection |
| Exhaust Valve | Manually adjustable |
| Controller | Time-programmable digital controller with optical overtemperature alarm |
| Safety | Dual-stage temperature safety device (DIN 12880 Class 2) |
| Standard Accessories | 2 chrome-plated wire shelves |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MDL |
| External Dimensions (L×H×W) | 834×800×685 mm |
| Internal Dimensions (L×H×W) | 600×435×435 mm |
| Temperature Range | +5 °C above ambient to 350 °C |
| Internal Volume | 115 L |
| Temperature Uniformity | ≤ ±0.5 °C |
| Airflow Rate | 400 L/min |
| Heating Power | 9.0 kW |
| Safety Class | Dual independent temperature safety device (DIN 12880, Class 2) |
| Fresh Air Filter | EU6 (F6), particle retention ≥1 µm |
| Rear Exhaust Port | Ø100 mm |
| Shelves | 2 chrome-plated adjustable shelves |
| Controller | MCS microprocessor-based controller with 25 stored programs, 100 segments per program, up to 500 total segments |
| Display | User-friendly LCD with intuitive menu navigation |
| Data Logging | Built-in electronic chart recorder with multiple real-time graphical display options |
| Real-Time Clock | Integrated |
| Ramp Function | Programmable via on-board editor |
| Door Seal | High-temperature silicone gasket |
| [Brand | Aerospace Zongheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model | CTN-1 |
| Application | Building Materials Flame Retardancy Testing |
| Measurement Object | Non-combustible/Flame-Retardant Building Materials |
| Repeatability Error | ±0.1% |
| Power Supply | AC 220/380 V, 50–60 Hz, ~0.5 kW |
| Airflow Velocity | (0.260 ± 0.026) m/s |
| Airflow Accuracy | ±0.1 m/s |
| Timer Accuracy | <1 s/h |
| Differential Pressure Range | 0–100 Pa |
| Fuel Gas | ≥95% Methane |
| Test Duration | 10 min |
| Combustion Chamber Material | AISI 304 Stainless Steel |
| Dimensions (L×W×H) | 3020 mm × 1020 mm × 3930 mm] |
| Brand | Concept |
|---|---|
| Origin | United Kingdom |
| Model | UL94 FLAMMABILITY CHAMBER |
| Chamber Volume | >1 m³ |
| Noise Level | 62.5 dB(A) |
| Burner Angle Adjustment | 0°, 20°, 45° |
| Compliant Standards | UL 94, IEC 60695-11-10/20, ASTM D635, ISO 1210, ISO 9772, BS 2782 Method 140A/140B |
| Gas Supply | 98% methane |
| Operating Ambient Temperature | 10–35 °C |
| Electrical Supply | 115–230 V AC, single-phase |
| Brand | SDLATLAS |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | M233P1 |
| Application Field | Textile and Home Furnishings |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FAR-ME1000-3 |
| Pricing | Upon Request |
| Brand | MEI (Marlin Engineering) |
|---|---|
| Origin | USA |
| Model | ME1000-3 |
| Application Scope | FAA AC 20-135, FAR Part 25.853, ASTM D635, ASTM D3801, HB5469, HB5470 |
| Construction | Stainless steel interior chamber with electrostatically coated exterior |
| Viewing Window | Tempered heat-resistant borosilicate glass (≥600 °C continuous service) |
| Ignition Method | High-voltage electric spark ignition system |
| Burner Mounting | Linear precision slide rail for rapid repositioning |
| Gas Control | Dual-stage pressure regulator and mass flow controller (propane or methane) |
| Sample Fixtures | Stainless steel clamps with calibrated 60° tilt jig and ASTM-compliant weight assembly |
| Flame Height Gauge | Precision stainless steel ruler (0–150 mm, ±0.5 mm accuracy) |
| Positioning Aid | Laser-aligned sample-to-burner distance gauge (fixed 20 mm ±0.2 mm per FAA vertical test requirement) |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | 45D |
| Chamber Construction | Stainless Steel Enclosure with Polycarbonate Viewing Window |
| Test Angle | Fixed 45° Specimen Mounting |
| Applicable Standards | ASTM D3823, ISO 6927 (adapted), UL 94 HB/VTM-0 pre-screening context, KSL 2017 (Korean Standard for Surface Burning Characteristics) |
| Burner Options | Air-Mix Burner & Micro/Meker Burner |
| Flame Impingement Control | Adjustable Pressure Regulators for Both Burners |
| Timing System | Dual Independent Digital Timers (Afterflame Time & Afterglow Time) |
| Specimen Thickness Limit | ≤5 mm |
| Sample Types | Rigid & Semi-Rigid Flat Panels (Wood, Metal, Plastic Laminates, Paperboard, Thin Composites) |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | HCF-NEK606 |
| Chamber Dimensions (W×D×H) | 1220 × 1045 × 1100 mm |
| External Dimensions (W×D×H) | 1300 × 1125 × 950 mm |
| Frame Material | 50×50×t3 mm Stainless Steel 304 |
| Burner Tube ID | Ø36 mm, SS304 |
| Venturi Mixer | Air/Propane Premixing |
| Air MFC | 77.7 ± 4.8 SLPM (180 L/min) |
| Propane MFC | 15 SLPM (13.5 ± 0.5 L/min) |
| Temperature Sensors | K-type (Ø8.0 mm) & R-type (Ø8.0 mm) Thermocouples |
| Data Acquisition | PC-connected DAQ with Bluetooth antenna pair |
| Control Rack Dimensions | 730 × 650 × 1600 mm, Aluminum Alloy |
| Safety System | Automated Ignition, Interlocked Door, Flame-Out Detection |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | IEC 60754-1&2 |
| Compliance | IEC 60754-1 Ed. 2.0 b:1994, IEC 60754-2 Ed. 1.0 b:1991, GB/T 17650 |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TIT |
| Price | Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FFH |
| Pricing | Available Upon Request |
| Application Field | Transportation Vehicles |
| Compliance Standards | GB 32086–2015, ISO 6941:2003, EN 407, EU Directive 95/28/EC, Volkswagen PV 3357 |
| Power Supply | AC 220 V, 2 A |
| Fuel Gas | Industrial Propane |
| Dimensions (L×D×H) | 340 × 240 × 760 mm |
| Weight | 26 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HRR-1-X |
| Pricing | Available Upon Request |
| Construction | Full Stainless Steel Enclosure |
| Radiant Heat Flux | 50 kW/m² |
| Ignition Source | 10 kV Electric Spark |
| Specimen Orientation | Horizontal |
| Exhaust Flow Rate | 0.024 m³/s |
| Compliance | JG 158–2004 Appendix H (China Building Industry Standard) |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | Polynorme 503 |
| Applicable Standard | NF P 92-504 |
| Test Principle | Vertical flame impingement using calibrated gas burner |
| Sample Holder | Dual U-shaped fixtures for rigid and flexible materials |
| Compliance | French building material fire reaction classification (M0–M4), rail industry non-metallic component qualification |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Polynorme 506 |
| Price | Upon Request |
| Standard Compliance | NFP 92-506 |
| Radiation Panel Dimensions | 305 mm × 305 mm × 70 mm porous ceramic |
| Metal Frame Dimensions | 320 mm × 320 mm |
| Ignition Flame Height | ~40 mm |
| Ignition Burner | 3 mm diameter copper tube |
| Preheat Time to 850 °C | 5–10 min |
| Thermometric Monitoring | High-temperature radiometer + 25 mm Ø × 0.2 mm thick copper disc sensor |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSCRS-A |
| Price | USD 1,450 (FOB Beijing) |
| Application Field | Electronics & Electrical Equipment |
| Test Specimens | Plastics and Non-Metallic Materials |
| Repeatability Error | ±1 s |
| Flame Power | 50 W (IEC 60695-11-3 / GB/T 5169.16-2008 Compliant) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCZRS-A |
| Application Field | Electrical & Electronic Equipment |
| Heating Element | Ni80/Cr20 alloy wire (Φ4 mm) |
| Repeatability Error | ±1°C |
| Intended Use | Flammability assessment of insulating materials, engineering plastics, and other solid combustible materials |