Pyrolyzer
Filter
Showing all 16 results
| Brand | Bosin |
|---|---|
| Origin | Shanghai, China |
| Model | PY-1050 |
| Temperature Range | Ambient to 1050 °C |
| Heating Rate | 0.1–100 °C/min |
| Pyrolysis Chamber Material | High-Purity Stainless Steel |
| Carrier Gas | Nitrogen (N₂) |
| Gas Flow Control | 0.1–100 mL/min |
| GC/MS Interface | Standard Transfer Line with Independent Temperature Control (up to 350 °C) |
| Safety Features | Over-Temperature Protection, Real-Time Gas Leak Detection |
| Software | Dual-Language (English/Chinese) Control & Data Acquisition Interface |
| Compliance | Designed for ASTM D7269, ISO 18242, and USP <621> chromatographic method integration |
| Brand | CDS Analytical |
|---|---|
| Origin | USA |
| Model | 6150 |
| Pyrolyzer Type | Filament-Heated Pyrolyzer |
| Temperature Range | Ambient to 1300 °C (1 °C increment) |
| Temperature Accuracy | ±0.1 °C |
| Cooling Time | <18 s (from 650 °C to <50 °C, gas-free) |
| Reproducibility | RSD ≤1.5% (polystyrene standard) |
| Transfer Line Max Temp | 350 °C |
| Programmable Steps per Method | Up to 10 |
| GC Trigger Support | Per-step synchronized GC start signal |
| Sample Tube | Reusable fused-silica quartz tube |
| Optional Autosampler | 48-position |
| Brand | CDS Analytical |
|---|---|
| Origin | USA |
| Model | 6200 |
| Pyrolyzer Type | Filament (Wire) Pyrolyzer |
| Temperature Range | Ambient to 1300 °C (1 °C increment) |
| Temperature Accuracy | ±0.1 °C |
| Cooling Rate | From 650 °C to <50 °C in ≤18 s (no cryogenic gas required) |
| Reproducibility | RSD ≤1.5% (polystyrene standard) |
| Transfer Line Max Temp | 350 °C |
| Programmable Steps per Method | Up to 10 |
| Sample Capacity | 48-position auto-sampler (optional) |
| Operating Interface | Integrated touchscreen with one-touch start |
| Heating System | Platinum RTD-integrated resistive filament |
| Atmosphere Control | Switchable carrier/reactive gases (e.g., He, air) |
| Modes | Direct-to-GC and Cold Trap (cryo-trap optional) |
| Software-Controlled Mode Switching | Yes |
| Optional Functions | Thermal Desorption, Dynamic Headspace, Electronic Flow Control, Spectral Library Integration |
| Brand | Frontier |
|---|---|
| Origin | Japan |
| Model | EGA/PY3030D |
| Pyrolyzer Type | Microfurnace-based Tubular Pyrolyzer |
| Temperature Range | 10 °C above ambient to 1050 °C (0.1 °C resolution) |
| Heating Rate | Programmable up to 600 °C/min (8-step temperature program) |
| Hold Time & Pyrolysis Time | 0.1–999.9 min (0.1 min step) |
| Cooling | Liquid nitrogen or liquid air |
| Interface Temperature Control (ITF) | 40–450 °C (1 °C step) |
| Reproducibility | RSD < 2% (GC-FID, certified per ASTM D7260 and ISO 17253) |
| Application Modes | EGA, TD, Single-shot Py, TD/PY Double-shot, Heart-cut Release Gas Analysis |
| Sample Introduction Options | Liquid injector, Dual-shot injector, Thermal Desorption (TD) module, Derivatization reactor, UV-assisted pyrolysis injector |
| Brand | GERSTEL |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PYRO |
| Instrument Type | Filament-Based Pyrolyzer |
| Temperature Range | 10–1000 °C |
| Heating Technology | Four-Point Resistance Measurement on Platinum Filament |
| Sample Introduction | Valveless, Transfer-Line-Free Direct Coupling to GC/MS |
| Optional Cryogenic Trapping | Compatible with CIS (Cold Injection System) for Dual-Stage Thermal Desorption |
| Automation | Fully Integrated with MPS Robotic Sample Handling Platform |
| Compliance | Designed for GLP/GMP environments |
| Brand | HPG (Huaputongyong) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Resistive-Filament Pyrolyzer |
| Model | HP2000-GC |
| Price Range | USD 42,000 – 70,000 |
| Compliance | IEC 62321-8:2017 |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Instrument Type | Curie-Point Pyrolyzer |
| Model | JCI-22 |
| Sample Heating | 160–1140 °C (via Curie-point heated Pt foil) |
| Preheating Temperature | 150 °C (≈60 s ramp) |
| Pyrolysis Zone Dimensions | 9 × 20 mm Pt foil |
| Sample Tube | Quartz |
| Probe Outer Diameter × Length | 35 × 180 mm |
| Probe Weight | 110 g |
| HF Generator Output | 48 W, 600 kHz |
| GC Trigger Interface | Ready signal input & Start signal output |
| Carrier Gas | He at ≥0.5 MPa (supplied via standard JCI-22 5 L cylinder) |
| Controller Dimensions | 150 × 200 × 320 mm |
| Compatibility | Direct insertion into standard GC/GC–MS split/splitless inlets |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | JHI-07 |
| Pyrolyzer Type | Microfurnace Pyrolyzer with Curie-Point Capability |
| Dual-Mode Operation | Curie-Point & Microfurnace |
| EGA Support | Yes |
| Quick-Release Interface | Yes |
| Column Head Cooler Compatibility | CIC-07 (Liquid Nitrogen Cooled) |
| Re-analysis Kit Included | Tenax GR Trap System for Targeted Peak Re-injection |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JHP-5 |
| Instrument Type | Curie-Point Pyrolyzer |
| Heating Method | High-Frequency Induction (600 kHz, 48 W) |
| Pyrolysis Time Range | 1 s – 99 h |
| Flow Path Switching | Solenoid Valve |
| Sensor Unit Dimensions/Weight | 90 × 280 × 160 mm / 2.5 kg |
| RF Power Supply Dimensions/Weight | 160 × 250 × 380 mm / 8 kg |
| Power Input | AC 100–240 V, 5 A |
| GC Compatibility | Universal (all standard GC systems, excluding proprietary non-standard interfaces) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JHP-22 |
| Instrument Type | Curie-Point Pyrolyzer |
| Heating Method | High-Frequency Induction with Curie-Point Ferromagnetic Foil |
| Sample Tube | Quartz, 4.5 mm ID (Pyrolysis Chamber) |
| Furnace Temperature Range | Ambient to 200 °C |
| Pyrolysis Duration | 1–99 s |
| Transfer Line Temperature Range | Ambient to 300 °C, Length: 0.7 m |
| RF Power Output | 48 W |
| Flow Path Switching | Solenoid Valve |
| Dimensions (W×H×D) | 305 × 190 × 465 mm |
| Weight | 18 kg |
| Power Supply | AC 100 V, 7 A |
| GC Compatibility | Universal GC Interface (Excluding Proprietary Direct-Coupled Systems) |
| Optional Curie Temperatures | 1040, 920, 764, 740, 670, 650, 590, 500, 485, 445, 423, 386, 358, 333, 315, 280, 255, 235, 220, 170, 160 °C |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JPS-700 |
| Instrument Type | Curie-Point Pyrolyzer |
| Maximum Sample Capacity | 40 samples |
| Pyrolysis Temperature Range | Up to 400 °C (typical operating range ≤300 °C) |
| Heating Method | High-Frequency Induction |
| RF Frequency | 600 kHz |
| RF Power Output | 48 W |
| Pyrolysis Duration Control | 1–9,999 s |
| Inter-Analysis Interval | 0.01–999.99 min |
| Carrier Gas Purge | Dual-point dry air purge (pressure ≥0.4 MPa) |
| GC Interface | Universal GC-mount adapter |
| Compliance | Compatible with ASTM D7250, ISO 11348, and USP <621> chromatographic system integration requirements |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | CZ-100A |
| Pyrolyzer Type | Resistive Filament (Platinum Wire or Ribbon) |
| Maximum Filament Temperature | 1400 °C |
| Temperature Ramp Stages | Up to 10-step programmable heating |
| Display | Color Touchscreen with Parameter Input & Storage (12 methods) |
| Power Loss Protection | Yes |
| Integrated Gas Path | Yes, compatible with external GC/MS without modification |
| Sample Introduction | Quartz tube (wire type) or coated probe (ribbon type) |
| Onboard Probe Cleaning Mode | High-temperature bake-out at 1400 °C |
| Mounting | Direct installation onto GC inlet via dedicated bracket |
| Interface | Synchronized trigger output for real-time GC/MS control |
| Compliance | Designed for ASTM D7213, ISO 11348, and USP <621> pyrolysis-GC applications |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CDS 5200 |
| Price | Upon Request |
| Pyrolysis Temperature Range | Ambient to 1400 °C (adjustable in 0.1 °C increments) |
| Temperature Accuracy | ±0.1 °C |
| Maximum Pressure Rating | 500 PSI (3400 kPa) |
| Heating Rate (Pulse Mode) | 10–20,000 °C/sec |
| Heating Rate (Programmed Mode) | 0.01–999.9 °C/sec or 0.01–999.9 °C/min |
| Programmable Steps per Run | Up to 8 steps with independent GC trigger per step |
| Transfer Line Max Temp | 350 °C |
| Interface Temp | ≥350 °C |
| Sample Path Material | Inert (e.g., SilcoNert®-treated stainless steel or fused silica) |
| Optional In-line Cold Trap | Integrated cryo-focusing with thermal desorption |
| Atmosphere Control | N₂, air, O₂, He, or custom gas (via external mass flow controller) |
| Catalytic Reactor | 3″ × 1/4″ OD 316 stainless steel, rated to 800 °C, user-replaceable catalyst bed |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PR600 |
| Pricing | Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | PY1000 Pyrolyzer |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LJ-100 |
| Instrument Type | Tube-Furnace Pyrolyzer |
| Pyrolysis Cell Temp Range | 5–400 °C (1 °C increment) |
| Probe Temp Range | 300–1200 °C (10 °C increment), 5-step programmable ramp |
| Probe Heating Rate | 0.01–20 °C/ms (11 selectable steps) |
| Probe Hold Time | 10 ms–99 s (10 ms increment) |
| Cleaning Temp | 1200 °C for 5 s |
| Dimensions | 387 × 245 × 130 mm (L×W×H) |
| Power | 250 W |
| Weight | 7 kg |