Animal Patient Monitor
Filter
Showing 1–30 of 39 results
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Model | BeneFusion eSP/eVP/eDS Vet |
| Device Type | Veterinary Infusion and Syringe Pump System with Integrated Data Acquisition |
| Regulatory Classification | Class II Medical Device (China NMPA), CE-marked for veterinary use |
| Compliance | IEC 60601-1, IEC 60601-2-24, ISO 13485, EN 62304 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Capnocheck Capnometer |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Capnograph Desktop CO₂ Monitor |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ECG Monitor |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ETCO₂-ANIMAL |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | CapnoScan Pro |
| Price | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HPMS |
| Instrument Type | ECG-based Multi-Parameter Physiological Monitor |
| Connectivity | Bluetooth 5.0 |
| Display Platform | Android tablet (included) |
| Data Output Formats | LabChart-compatible binary, CSV |
| Heating Platform | Temperature-regulated (setpoint range: 25–42 °C, ±0.3 °C stability) |
| Probe Compatibility | Rectal thermistor, ECG needle electrodes, SpO₂ sensor (reflectance-type), NIBP cuff (rat/mouse), Capnography module (sidestream CO₂) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | MouseOx |
| Sensor Type | Reflectance-based photoplethysmographic probe |
| Measurement Parameters | SpO₂ (0–100%, accuracy < ±1.5% across full range), Pulse Rate (90–900 BPM, update latency 0.72 s per beat), Respiratory Rate (25–450 breaths/min, reported as 10-breath moving average every 1.7 s), Pulse Amplitude (0–800 µm vessel diameter equivalent, accuracy < ±2.4%), Respiratory Amplitude (quantified as thoracic/abdominal displacement magnitude) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Small Animal Physiological Monitoring System |
| Instrument Type | Multi-Parameter Physiological Monitor |
| Measurement Parameters | Rectal Temperature, ECG, Respiration Rate, SpO₂, Non-Invasive Blood Pressure (NIBP), End-Tidal CO₂ (EtCO₂) |
| Heating Platform | Adjustable Thermostatic Surface (25–42 °C, ±0.1 °C stability) |
| Data Interface | Bluetooth 5.0 to Android Tablet (pre-installed monitoring software) |
| Data Export | CSV via USB or cloud-synced export to Windows/macOS workstations |
| Compliance | CE Marked, RoHS Compliant, Designed for GLP-Compliant Preclinical Research |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | IBP-2000 |
| Pricing | Available Upon Request |
| Brand | Mindray |
|---|---|
| Model | BC-60R Vet |
| Origin | Shanghai, China |
| Instrument Type | Veterinary Hematology Analyzer |
| Detection Principle | SF-Cube Platform — Laser Scatter + Fluorescent Staining (S-Scatter & F-Fluorescence) |
| Analysis Dimensionality | 3D Multi-Parameter Cell Discrimination |
| WBC Differential Technology | Third-Generation Animal-Specific Fluorescent Staining |
| Reticulocyte (RET) Detection | Optimized RNA-Specific Fluorescent Dye with 650 nm Excitation |
| Compliance | Designed for GLP-aligned veterinary diagnostic workflows |
| Software | Embedded veterinary-specific analysis algorithms with audit trail capability |
| Brand | Mindray |
|---|---|
| Model | BeneFusion VP3 Vet / SP3 Vet |
| Origin | Shanghai, China |
| Instrument Type | Veterinary Infusion Pump |
| Regulatory Classification | Class II Medical Device (China NMPA) |
| Intended Use | Continuous or intermittent intravenous, intra-arterial, or subcutaneous fluid and drug delivery in veterinary clinical settings |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BS-240 Vet |
| Instrument Type | Veterinary Clinical Chemistry Analyzer |
| Regulatory Certification | CNAS-Accredited Reference Laboratory (ISO/IEC 17025) |
| Sample Volume Minimum | 2 µL |
| Reaction Volume Minimum | 100 µL |
| Temperature Control | Reaction Disk at 37 ± 0.1 °C (enclosed thermostatic system), Reagent Storage at 2–12 °C (continuous refrigeration) |
| Carryover Rate | < 0.05% |
| Software Interface | Fully Localized Chinese GUI with Veterinary-Specific Workflow Logic |
| Parameter Flexibility | Up to 64 selectable assays |
| Reference Intervals | Species-specific (canine and feline), validated against multi-center clinical serum cohorts |
| Data Traceability | AAA Traceability Architecture (Analytical–Algorithmic–Archival), compliant with GLP audit requirements |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ePM 12M Vet |
| Instrument Type | Electrocardiography (ECG)-Enabled Multi-Parameter Veterinary Monitor |
| NIBP Algorithm | Species-Specific Cuff-Based Blood Pressure Algorithm |
| SpO₂ Technology | Motion-Tolerant and Low-Perfusion Resistant Pulse Oximetry |
| ECG Analysis | Multi-Lead Digital Signal Processing with CrozFusion™ Signal Fusion |
| Expandable Modules | CO₂ (Capnography), IBP (Invasive Blood Pressure, up to 4 channels), Cardiac Output (C.O.), Anesthetic Gas (AG), O₂/CO₂ (Artema® Technology) |
| Display | 12.1-inch Capacitive Touchscreen with Gesture Support |
| Data Storage | Internal Flash Memory + USB Export Capability |
| Compliance | IEC 60601-1, IEC 60601-2-51 (for Veterinary Monitors), ISO 13485 Certified Manufacturing |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | UA-60V |
| Instrument Type | Semi-Automated Urine Dipstick Analyzer |
| Operating Temperature | 15–30 °C |
| Operating Humidity | 30–85% RH |
| Power Supply | DC 5 V / 1 A (adapter input: AC 220 V, 50 Hz) |
| Compatible Test Strips | Strips-11 (11-parameter) and Strips-15 (15-parameter) |
| Strip Capacity | 50 strips per roll |
| Shelf Life | 24 months (unopened) |
| Storage Conditions | 0–30 °C, dry, protected from direct sunlight |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Model | Vetus 9 |
| Imaging Platform | ZST+ Zone Scanning Technology |
| Core Modalities | B-mode, Color/Power Doppler, Pulsed-wave & Continuous-wave Spectral Doppler, Contrast-enhanced Ultrasound (UWN+), Shear Wave Elastography, Tissue Doppler Imaging (TDI), Tissue Tracking Quantification |
| Regulatory Status | CE Marked, FDA 510(k) cleared for veterinary use |
| Intended Use | Diagnostic imaging and functional assessment in companion animals, equine, and large animal clinical practice |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | WATO EX-20Vet |
| Instrument Type | Veterinary Anesthesia Delivery System |
| Compliance | Designed to meet ISO 80601-2-13 (Medical Electrical Equipment – Part 2-13: Particular Requirements for Anesthesia Equipment) and IEC 60601-1 safety standards |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WATO EX-35Vet |
| Instrument Type | Veterinary Anesthesia and Monitoring System |
| Display | 10.4-inch TFT high-resolution touchscreen |
| Ventilation Modes | Volume-Controlled (VCV), Pressure-Controlled (PCV), Pressure-Controlled Ventilation with Volume Guarantee (PCV-VG), Spontaneous Breathing Support |
| Minimum Tidal Volume | 5 mL |
| Gas Monitoring Options | EtCO₂, Oxygen (O₂), Nitrous Oxide (N₂O), Halogenated Anesthetics (e.g., Isoflurane, Sevoflurane) |
| Vaporizer | Precision V60 calibrated halogenated anesthetic vaporizer (CE & FDA cleared) |
| Breathing Circuit | Integrated dual-mode (rebreathing/non-rebreathing), tool-free soda lime canister replacement |
| Leak Test | Automated self-test with graphical troubleshooting guidance |
| Waste Gas Scavenging | Optional passive or active scavenging system |
| Compliance | Designed to meet IEC 60601-1, IEC 60601-2-13, ISO 80601-2-13, and applicable veterinary medical device regulatory requirements |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WATO EX-65 Pro Vet |
| Instrument Type | Integrated Veterinary Anesthesia & Ventilation System |
| Regulatory Classification | Class II Medical Device (CN), CE-marked for Veterinary Use |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Z70 Vet |
| Instrument Type | Veterinary Diagnostic Ultrasound System |
| Display | 15-inch Full-View LCD Touchscreen |
| Application Focus | Canine, Feline, Equine, Bovine, and Ovine Imaging |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MouseOx |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Static Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Bore Diameter | 60 mm |
| Application Scope | In vivo MRI of mice and rats using MR contrast agents |
| Target Applications | Spontaneous tumor detection (brain, subcutaneous, liver), longitudinal tumor growth & therapy response monitoring, obesity phenotyping, MR contrast agent development |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NIBP-2000 Series |
| Pricing | Available Upon Request |
| Cuff Compatibility | Rat, Cat, Dog, and Large Animal (e.g., Swine, Sheep, Non-Human Primates) |
| Operating Modes | Small Animal (SA) Mode (<9.1 kg / 20 lbs), Large Animal (LA) Mode (≥9.1 kg / 20 lbs) |
| Data Interface | RS-232 Serial Port (Cable Optional) |
| Output Options | Internal Thermal Printer (Built-in) or External Printer (Optional) |
| Weight | 1.6 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Monitor-Compatible Oximetry Sensor |
| Pricing | Upon Request |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Not Specified |
| Pricing | Upon Request |
| ECG Range | 30–350 bpm |
| NIBP Range | 40–270 mmHg |
| IBP Range | −10–300 mmHg |
| RR Range | 0–120 bpm |
| TEMP Range | 25.0–45.0 °C |
| SpO₂ Range | 0–100 % |
| PR Range | 30–250 bpm |
| CO₂ Range (optional) | 0–10.0 % |
| Data Retrospective | 360 hours |
| Display | 10.4″ TFT color LCD, 7-waveform simultaneous display |
| Power | Rechargeable high-capacity battery with standby mode |
| Connectivity | Wired/Wireless LAN, central station integration support |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model Series | RM700 / RM800 / RM800T |
| Instrument Type | Electrocardiography (ECG)-Enabled Veterinary Monitor |
| Display | 10.1" or 12.1" TFT LCD (touchscreen optional) |
| Blood Pressure Method | Non-invasive oscillometric with species-specific algorithms |
| EtCO₂ Technology | Microstream capnometry |
| ECG Configuration | Standard 5-lead simultaneous acquisition |
| Parameter Set | ECG, SpO₂, NIBP, Respiratory Rate (Resp), Temperature (Temp), End-Tidal CO₂ (EtCO₂), Heart Rate (HR) |
| Brand | STARR Instruments |
|---|---|
| Origin | USA |
| Manufacturer | STARR Instruments, Inc. |
| Model | MouseOx Plus |
| Device Type | Small Animal Physiological Monitor |
| Measurement Principles | Reflectance Pulse Oximetry (735 nm & 850 nm dual-wavelength LED photoplethysmography), Thermal Sensing (for temperature) |
| Regulatory Status | CE-marked, FDA 510(k)-cleared (K122924), ISO 13485-certified manufacturing |
| Compliance | Designed to support GLP-compliant preclinical studies |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | V3404 |
| ECG Leads | 3- or 5-lead configuration |
| Heart Rate Range | 15–350 bpm |
| Display | Backlit LCD |
| Power | Rechargeable internal battery (optional AC adapter) |
| Connectivity | RS-232 serial interface (V3362 cable optional) |
| Printer Option | V3408 thermal printer module |
| Parameters Measured | ECG waveform, SpO₂, Temperature (rectal/probe), Respiration rate (impedance-based) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | V6004 |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SurgiVet V6004 |
| Pricing | Available Upon Request |
