| Brand | ASTR/ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DM3300 |
| Price | USD 3,500 (FOB Shanghai) |
| Measurement Range | 1,000–40,000 kJ/kg |
| Accuracy | Relative Standard Deviation ≤0.2% |
| Temperature Resolution | 0.0001 K |
| Test Duration | ~15 min per sample |
| Power Consumption | ≤60 W |
| Dimensions | 650 mm × 390 mm × 450 mm |
| Operating Ambient | 10–35 °C, RH ≤80%, 220 V ±10% AC |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XRY-1C |
| Measurement Mode | Isoperibol (Constant-Temperature Jacket) |
| Instrument Type | Oxygen Bomb Calorimeter |
| Intelligence Level | Fully Automated with PC Control |
| Temperature Range | 5°C to 35°C |
| Temperature Detection Threshold | 0.001°C – 0.01°C |
| Temperature Resolution | 0.0001°C |
| Temperature Stability | ≤0.001°C per 30 min |
| Temperature Tracking Rate | ~0.01°C/s – 0.05°C/s |
| Single-Sample Test Duration | ~8 min (Standard Mode), ~3 min (Rapid Mode) |
| Bomb Pressure Rating | 20 MPa |
| Pressure Resolution | 0.001 MPa |
| Brand | Concept |
|---|---|
| Origin | United Kingdom |
| Model | Microscale Combustion Calorimeter |
| Standard | ASTM D7309 |
| Heating Rate Range | 0.2–5 K/s (±5% accuracy) |
| Temperature Range | 0–1000 °C |
| Detection Limit | 5 mW |
| Repeatability | ±2% (for 5 mg sample) |
| Oxygen Measurement | Paramagnetic sensor, 0–100% O₂, accuracy ±0.1% |
| Gas Flow Control | High-precision mass flow controllers for N₂ (80 cm³/min, max 100 cm³/min) and O₂ (20 cm³/min, max 50 cm³/min) |
| Sample Mass Range | 0.5–10 mg |
| Furnace | 10 mm alumina tube with dual Kanthal heating elements |
| Power Supply | 230 V AC, 50 Hz, 10 A |
| Dimensions (W×H×D) | 600 mm × 1025 mm × 500 mm |
| Weight | 42 kg |
| Operating Ambient | 10–35 °C |
| Brand | Fauske |
|---|---|
| Origin | USA |
| Instrument Type | Adiabatic Reaction Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Model | ARSST |
| Compliance Basis | DIERS-validated two-phase flow methodology (OSHA-recognized “Exemplary Engineering Practice”) |
| Sample Volume | 5–10 g in 10 mL lightweight quartz test cell |
| Pressure Vessel Capacity | 350 mL rated pressure vessel |
| Operating Modes | Scanning & Isothermal |
| Optional Accessories | High-pressure test cells, Flow-Regime Evaluation Detector (FRED™) |
| Brand | Fauske |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | VSP2 |
| Price Range | USD 135,000 – 270,000 (based on configuration and service package) |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Sample Volume | 116 mL |
| Cell Wall Thickness | 0.01 in (0.254 mm) |
| Thermal Inertia (φ) | ≤ 1.05 |
| Maximum Pressure Rating | >2000 psi (13.8 MPa) |
| Heating | Dual-zone (internal sample heater + external guard heater) |
| Pressure Equalization | Active dynamic compensation |
| Stirring | Optional magnetic stirring (standard & high-torque super-magnetic variants) |
| Cell Materials | 304 SS, 316 SS, Hastelloy C, Titanium, Quartz |
| Test Modes | Closed, Venting (small-scale relief), Isothermal, Dynamic Ramp, Quench Simulation |
| Brand | FoShan TST |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARC Series |
| Pricing | Available Upon Request |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-130 |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | 25–500 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.01 K |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 60,000 J |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Sample Chamber Diameter | 130 mm |
| Sample Chamber Height | 200 mm |
| Brand | H.E.L (UK) |
|---|---|
| Origin | United Kingdom |
| Model | H.E.L Dual Simular Ambient/High-Pressure Dual-Reactor Calorimetry System |
| Instrument Type | Reaction Calorimeter |
| Measurement Modes | Isothermal Power Compensation Calorimetry, Isothermal Heat-Flow Calorimetry, Isoperibolic Reflux Calorimetry, Dynamic Ramp Calorimetry |
| Temperature Range | −30 °C to 225 °C |
| Maximum Pressure Rating | 100 Pa (vacuum to 100 Pa absolute) |
| Reactor Volumes | 0.5 L, 1 L, 2 L |
| Materials | Borosilicate Glass, 316 Stainless Steel, Hastelloy C-276 |
| Calibration Heater | 150 W |
| Automation Level | Fully Automated with Integrated Feedback Control |
| Sensor Integration | pH, Turbidity, In-situ FTIR, Raman, Particle Size Probes, Mass Flow Controllers (MFCs), Precision Load Cells |
| Software Compliance | Supports ALCOA+ principles, audit trail, electronic signatures (21 CFR Part 11–ready configuration available) |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | iso-BTC+ |
| Measurement Mode | Isothermal Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC-compatible architecture) |
| Temperature Range | −60 °C to +100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 10,000 J/K |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Sample Chamber Dimensions | 350 × 350 mm (W × D) |
| Maximum Compensation Power | 200 W |
| Minimum Detectable Heat Flow | 5 mW |
| Brand | H.E.L |
|---|---|
| Model | PAC-02 |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | 20–350 °C |
| Temperature Resolution | 0.1 °C/min |
| Precision | ≤0.1 °C |
| Sample Chamber Volume | 2015 mL |
| Automation Level | Fully Automated |
| Origin | Fujian, China |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-500 |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −40 °C to 500 °C |
| Temperature Resolution | 1 K |
| Precision | ±0.1% |
| Single-Sample Test Duration | ~30 min |
| Heat Capacity | 10,500 J/K |
| Outer Bath Volume | ~20 L |
| Inner Bath Volume | 250 mL |
| Operating Modes | Adiabatic & Isothermal Calorimetry |
| Chamber Dimensions (Standard) | Φ35 × 35 cm or Φ50 × 50 cm |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-500 |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −80 °C to 500 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.01 K |
| Single-Sample Test Duration | Up to 1000 min |
| Heat Capacity | 60,000 J |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Adiabatic Control Method | Real-time Online PhiTEC Calibration |
| Sample Chamber Dimensions | Φ50 × 50 cm (standard), Φ35 × 35 cm (optional) |
| Pressure Rating | Up to 30 MPa |
| Data Channels | Expandable to 8 or 16 independent temperature inputs |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | HP Simular |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automated |
| Temperature Range | −30 °C to 210 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Heat Capacity Range | ±750 J/K |
| Maximum Pressure | 100 bar (upgradable to 200 bar) |
| Vessel Volume Options | 0.5 L, 1 L, 2 L |
| Vessel Materials | 316 Stainless Steel or Hastelloy C-276 |
| Stirring System | PTFE-coated shaft with 4-blade PTFE impeller (45–60° pitch) |
| Pressure Relief | Swagelok 316SS PRV + dial pressure gauge |
| Integrated Sensors | Temperature, pressure, optional in situ FTIR/Raman/turbidity/particle size |
| Calibration Heater | 150 W power-compensation heater |
| Control Software | HEL ChemScan™ with PAT integration, audit trail, and 21 CFR Part 11 compliance support |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | isoBTC-500 |
| Temperature Range | −60 °C to 100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 10,000 J/K |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Instrument Type | Accelerating Calorimeter |
| Measurement Mode | Isothermal Calorimetry |
| Compliance | Designed for GLP/GMP-aligned battery thermal safety testing |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | Phi-TEC I |
| Instrument Type | Adiabatic Accelerating Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −60 °C to 500 °C |
| Temperature Resolution | 0.005 K |
| Temperature Accuracy (direct sample mode) | ±0.01 °C |
| Temperature Stability (isothermal mode) | ±0.001 °C |
| Heat Capacity | ~10,000 J/K |
| Sample Mass Range | 0.5–80 g |
| Pressure Range | 0–300 bar (optional up to 1000 bar) |
| Pressure Accuracy | ±0.05% FS |
| Pressure Resolution | 0.01 bar |
| Exothermic Detection Sensitivity | 0.005–0.2 °C/min |
| φ-factor (low-φ cell) | ≤1.05 |
| Stirring | Electromagnetic, 0–500 rpm (mechanical stirrer optional) |
| Operating Modes | HWS (Heat-Wait-Search), RAMP, ISO |
| External/Inner Dewar Volume | 10 mL each |
| Single-Sample Test Duration | ~600 min |
| Dimensions | 30 cm × 37 cm × 50 cm |
| Power Supply | 220 V AC, 13 A |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Phi-TEC II |
| Price Range | USD 135,000–270,000 (FOB UK) |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −80 °C to 500 °C |
| Temperature Resolution | 0.001 K |
| Temperature Accuracy (Direct Sample Mode) | ±0.001 °C |
| Temperature Tracking Rate | Up to 400 °C/min (Low-Φ mode) |
| Standard | 50 °C/min |
| Pressure Range | 0–300 bar (optional up to 1000 bar) |
| Pressure Tracking Rate | 0–200 bar/min (optional 700 bar/min) |
| Pressure Accuracy | ±0.05% FS |
| Pressure Resolution | 0.01 bar |
| Heat Release Detection Sensitivity | 0.002–0.2 °C/min |
| Sample Mass Capacity | 0.5–80 g |
| Adiabatic Correction Factor (Φ) | ≤1.05 (optimized for Phi-TEC II) |
| Outer & Inner Dewar Volume | 60 mL each |
| Thermal Capacity | 60,000 J |
| Single-Test Duration | Up to 1000 min |
| Stirring | Electromagnetic, 0–500 rpm (mechanical option available) |
| Operating Modes | HWS (Heat-Wait-Search), RAMP, ISO (Isothermal) |
| Dimensions | 30 cm × 37 cm × 50 cm |
| Power Supply | 220 V AC, 13 A, single-phase |
| Brand | HEL (Hazard Evaluation Laboratories) |
|---|---|
| Origin | UK |
| Model | PhiTEC II |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Function | Micro-scale |
| Temperature Range | 0–500 °C |
| Temperature Detection Threshold | 0.02 °C/min |
| Adiabatic Temperature Tracking Rate | 200 °C/min |
| Maximum Calorimetric Chamber Pressure Rating | 137 bar |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | Simular 10L/20L |
| Calorimetry Mode | Adiabatic |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automated |
| Temperature Range | −30 °C to 225 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Maximum Jacket Pressure | 100 bar |
| Heat Capacity Range | ±750 J/K |
| Vessel Materials | Borosilicate Glass, 316 Stainless Steel, Hastelloy C-276 |
| Compatible PAT Interfaces | FTIR, Raman, pH, DO, ORP, Turbidity, Pressure, Temperature |
| Brand | HEL |
|---|---|
| Origin | UK |
| Model | SIMULAR |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal Calorimeter |
| Temperature Range | −80 to 350 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.1% |
| Single-Sample Test Duration | 300 min |
| Heat Capacity | 10,000 J |
| External Water Bath Volume | 1000 mL |
| Internal Water Bath Volume | 1000 mL |
| Brand | HEL |
|---|---|
| Origin | UK |
| Model | Simular |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automatic |
| Temperature Range | −30 °C to 225 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Heat Capacity Range | ±750 J/K |
| Reactor Volumes | 500 mL, 1 L, 2 L |
| Pressure Range | Vacuum to 100 bar (material-dependent) |
| Reactor Materials | Borosilicate Glass, 316 Stainless Steel, Hastelloy C-276 |
| Dual-Reactor Option | Yes |
| Sensor Integration | Temperature, Pressure, pH, Turbidity, In-situ FTIR, Raman, Particle Size Probes |
| Calorimetric Modes | Power Compensation (Calibration-Free), Heat Flow, Isothermal, Reflux, Iso-periodic |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | TSu |
| Instrument Type | Accelerating Rate Calorimeter (ARC®-style) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | –60 °C to 500 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | ~600 min |
| Heat Capacity | ~10,000 J/K |
| Outer Dewar Volume | ~10 mL |
| Inner Dewar Volume | ~10 mL |
| Sample Mass Range | 0.5–5 g |
| Pressure Range (standard) | 0–200 bar |
| Sample Cell | 8 mL spherical vessel (material options: borosilicate glass, stainless steel, Hastelloy®, custom alloys) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Reaction Calorimeter |
| Intelligence Level | Intelligent Control |
| Temperature Range | Ambient to 1600 °C |
| Temperature Detection Limit | 1600 °C |
| Temperature Resolution | ±1 °C |
| Temperature Stability | ±1 °C |
| Precision | ±1 °C |
| Heat Capacity Calibration Reference | 12,000 kcal (coal-calorimetry equivalent) |
| Sample Mass | 5 g |
| Heating Element | Silicon Molybdenum (MoSi₂) Rod |
| Heating Rate | 0.1–100 °C/min |
| Power Measurement Range | ±2000 mW |
| Minimum Power Resolution | 0.1 µW |
| Power Noise Floor | <0.1 µW |
| Electrical Supply | 220 V AC, 3000 W |
| Atmosphere Control | Dual-gas inlet with mass flow control (max. 5 L/min per channel) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Static Jacket (22 °C and 30 °C) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40 000 J |
| Cooling Medium | Tap Water |
| Cooling Flow Rate | 50–60 L/h (55 L/h at 18 °C) |
| Max Oxygen Pressure | 40 bar |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity Limit | 80 % RH |
| Protection Rating | IP20 |
| Power Supply | 100–240 V, 50/60 Hz |
| Power Consumption | 120 W |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Compliance | DIN 51900, ISO 1928 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol (Regnault–Pfaundler isothermal principle) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40,000 J |
| Outer Water Bath Capacity | Not specified |
| Inner Water Bath Capacity | Not specified |
| Cooling Medium | Tap water |
| Min. Coolant Flow Rate | 50–60 L/h at 18 °C |
| Max. Oxygen Pressure | 40 bar |
| Protection Rating | IP20 |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Compliance | DIN 51900, ISO 1928 |
| Interfaces | RS232 (balance, printer, PC), USB |
| Power Supply | 100–240 V, 50/60 Hz, 120 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | IKA C 3000 eco Package |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibolic Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibolic mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| Outer Water Jacket Volume | unspecified |
| Inner Water Jacket Volume | unspecified |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Sample Throughput | 4 measurements/h (isoperibol), 6 measurements/h (dynamic) |
| Heat Capacity Calibration Range | 40,000 J |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Cooling Medium | Tap water (12–27 °C), max. pressure 1.5 bar, flow rate 60–70 L/h (KV600 chiller compatible) |
| Max. Oxygen Pressure | 40 bar |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Ambient Operating Conditions | 20–25 °C, ≤80 % RH |
| Ingress Protection | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz, 2000 W |
| Compliance Standards | DIN 51900, DIN EN ISO 1716, DIN EN ISO 9831, DIN EN 15170, DIN CEN TS 14918, ASTM D240, ASTM D4809, ASTM D1989, ASTM D5865, ASTM E711, ISO 1928, GB/T 213 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/12 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| External Water Jacket Volume | ~8 L |
| Internal Water Jacket Volume | ~2.5 L |
| Max. Oxygen Pressure | 40 bar |
| Cooling Medium Flow Rate | 60–70 L/h (at 18 °C) |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Rated Input Power | 2000 W |
| Protection Rating | IP20 |
| Ambient Operating Conditions | 20–25 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Country of Origin | Imported |
| Model | C 7000 Basic Equipment Set 1 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol Dry-Mode Combustion Calorimetry (ISO 1928) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.2 % RSD (per 1 g benzoic acid, NIST SRM 39i) |
| Single-Sample Test Duration | ~3–5 min |
| Heat Capacity | 30,000 J/K |
| Cooling Medium | Tap water |
| Minimum Cooling Flow Rate | 120–180 L/h |
| Max Operating Oxygen Pressure | 40 bar |
| Max Cooling Medium Pressure | 9 bar |
| Ambient Temperature Range | 18–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Power Supply | 220–240 V, 50/60 Hz |
| Input Power | 260 W |
| Dimensions (W×D×H) | 310 × 395 × 490 mm |
| Weight | 50.162 kg |
| Interfaces | RS232 (balance, printer, PC), Centronics printer port |
| Oxygen Bomb Recognition | Automatic encoded detection |
| Compatible Crucibles | C14 combustion crucibles (retrofittable) |
| Software | C5040 CalWin v3.x (menu-driven, GLP-compliant data handling) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C 3000 eco |
| Calorimetric Principle | Isoperibol Oxygen Bomb Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Measurement Time | 15 min |
| Heat Capacity Calibration Range | Up to 40,000 J |
| Outer Water Jacket Volume | Approx. 3.5 L |
| Inner Water Bucket Volume | Approx. 2.2 L |
| Operating Ambient Temperature | 20–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Protection Rating | IP20 (DIN EN 60529) |
| Power Supply | 220–240 V, 50/60 Hz, 1700 W |
| Dimensions (W × D × H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Cooling Medium | Tap water or external chiller (e.g., RC 2 basic) |
| Oxygen Pressure | Up to 40 bar |
| Compliance Standards | ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, GB/T 213 |
| Data Interfaces | Ethernet, RS232, USB, SD card slot |
| Optional Accessories | C6010 & C6012 decomposition bombs, RC 2 basic recirculating chiller |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Modes | Adiabatic, Isoperibol (Isothermal), Dynamic |
| Temperature Range | 22–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (Adiabatic & Isothermal, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity Calibration Range | 40,000 J |
| Cooling Circulator | RC 2 Basic |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Max Oxygen Pressure | 40 bar |
| Cooling Medium | Tap water |
| Min Flow Rate | 60 L/h |
| Max Flow Rate | 70 L/h |
| Ambient Operating Temp | 20–25 °C |
| Relative Humidity Limit | ≤80% RH |
| Protection Class | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 2000 W |
| Dimensions (W×D×H) | 500 × 425 × 450 mm |
| Weight | 29 kg |