Incubator Equipment
Filter
Showing 1–30 of 406 results
| Brand | Airy |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MagiCube |
| Heating Method | Air-Jacketed |
| Cooling Method | Thermoelectric (Peltier) |
| Humidification Reservoir | External Water Tank |
| Temperature Range (with Humidification) | Ambient + 3°C to +40°C |
| Temperature Range (without Humidification) | Ambient + 3°C to +40°C |
| Temperature Uniformity | ±0.1°C |
| Relative Humidity Range | 65%–96% RH |
| Dimensions | Central Control Unit: 270 mm × 232 mm × 338 mm |
| Cell Culture Chamber (Base Model) | 159.5 mm × 109.5 mm × 22 mm |
| Humidification Module | 100 mm × 100 mm × 212 mm |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CNT 1000plus |
| Cooling Method | Compressor-based refrigeration |
| Air Circulation | Natural convection |
| Temperature Range | −10 °C to +90 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity (at 37 °C, empty chamber) | ±0.1 °C |
| Chamber Volume | 1000 L |
| Display | 7-inch full-color TFT touch screen |
| Control System | PID + fuzzy logic algorithm |
| Data Logging Capacity | 10-year continuous temperature recording (non-editable, exportable via USB flash drive) |
| Audit Trail | 16,000 entries (user actions & alarms, non-modifiable, exportable) |
| User Management | Up to 5 configurable accounts with role-based permissions |
| Multi-point Temperature Calibration | Yes |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Refrigerant | Environmentally compliant (R290/R600a blend) |
| Insulation | Monolithic polyurethane foam injection (≥80 mm thickness) |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating Power | 3200 W |
| Operating Ambient | 5–35 °C (optimal: 23±2 °C) |
| Safety Features | Over-temperature alarm, door-open alert, compressor overpressure protection, leakage current protection, sensor fault detection, auto-restart after power failure |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | CNT 150plus |
| Cooling Method | Compressor-based refrigeration |
| Air Circulation | Natural convection |
| Temperature Range | −10 °C to +90 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity (at 37 °C) | ±0.1 °C |
| Chamber Volume | 150 L |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Insulation | Monolithic polyurethane foam injection |
| Display | 7-inch full-color TFT touch screen |
| Control System | PID + fuzzy logic algorithm |
| Data Logging | ≥10 years of uneditable timestamped temperature records (exportable via USB) |
| Audit Trail | 16,000+ immutable operation and alarm entries (USB export) |
| User Management | 5 configurable user accounts with role-based permissions |
| Communication Interfaces | RS232, RS485, USB |
| Language Options | English / Chinese |
| Power Supply | AC 220 V, 50/60 Hz |
| Safety Features | Over-temperature alarm, door-open alert, compressor overpressure protection, leakage current protection, sensor fault detection, auto-restart after power recovery |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNT 460plus |
| Price Range | USD 7,000 – 14,000 (FOB Shanghai) |
| Cooling Method | Hermetic Compressor Cooling |
| Air Circulation | Forced Convection |
| Temperature Range | −10 °C to +90 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity (at 37 °C) | ±0.3 °C (typical), ±0.8 °C (max across chamber) |
| Chamber Volume | 460 L |
| Display | 7-inch Full-Color TFT Touchscreen |
| Control Algorithm | PID with Fuzzy Logic Compensation |
| Data Logging | Internal non-volatile memory (3 years @ 1-min intervals) |
| Audit Trail | 16,000 entries (user actions, alarms, system events) |
| User Management | 5 configurable roles with granular permission levels (e.g., operator, technician, administrator) |
| Temperature Calibration | Multi-point offset correction (up to 9 points) |
| Compressor | SECOP (Danfoss Group), hermetic rotary type |
| Condenser Fan | EBM-Papst, EC brushless DC motor |
| Refrigerant | R134a (ODP = 0, GWP = 1,430) |
| Insulation | Monolithic polyurethane foam (≥80 mm thickness, closed-cell, density ≥38 kg/m³) |
| Door Design | Dual-glass door (outer tempered safety glass, inner laminated low-E glass), silicone-sealed viewing window (Ø50 mm port on right side) |
| Communication Interfaces | RS-232, RS-485, USB-B (host mode) |
| Language Support | English / Chinese toggle |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Heating Capacity | 2.3 kW |
| Ambient Operating Conditions | 5–35 °C, 40–80% RH (optimal: 23 ±2 °C, 50 ±5% RH) |
| Safety Certifications | CE-marked per IEC 61010-1:2010, EN 61326-1:2013 (EMC), compliant with ISO 13485 design control principles for medical device support applications |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNT 760plus |
| Price Range | USD 7,000 – 14,000 (FOB Shanghai) |
| Cooling Method | Hermetic Compressor Cooling |
| Air Circulation | Forced Convection |
| Temperature Range | −10 °C to +90 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity (at 37 °C) | ±0.3 °C |
| Chamber Volume | 760 L |
| Display | 7-inch Full-Color TFT Touchscreen |
| Control Algorithm | PID + Fuzzy Logic Hybrid Control |
| Data Logging Capacity | 10-year continuous recording (non-editable, USB exportable) |
| Audit Trail | 16,000 entries (user actions & alarms, timestamped, immutable export via USB) |
| User Management | 5 configurable roles with granular permission levels |
| Temperature Calibration | Multi-point offset correction (up to 12 points) |
| Compressor | SECOP (Danfoss Group), hermetically sealed |
| Condenser Fan | EBM-Papst (Germany) |
| Refrigerant | R134a (ozone-friendly, low-GWP) |
| Insulation | Monolithic polyurethane foam (≥80 mm thickness, closed-cell, CFC-free) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Heating Power | 3200 W |
| Operating Ambient | 5–35 °C (optimal: 23–27 °C, RH ≤70%) |
| Safety Features | Over-temperature cutoff, door-open alarm, compressor high-pressure protection, leakage current protection, sensor fault detection, auto-restart after power recovery |
| Interface Ports | RS232, RS485, USB-B (data export & firmware update) |
| Door Design | Dual-door structure with tempered glass inner door (Ø50 mm silicone port on right side wall) |
| Standard Shelving | 2 stainless steel shelves (3 optional) |
| Energy Efficiency | ≥40% lower power consumption vs. conventional incubators under identical load and ambient conditions |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CNT 80plus |
| Cooling Method | Compressor-based Refrigeration |
| Air Circulation | Forced Convection |
| Temperature Range | −10 °C to +90 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity | <1 °C |
| Chamber Volume | 80 L |
| Display | 7-inch Full-Color TFT Touchscreen |
| Control Algorithm | PID + Fuzzy Logic |
| Data Logging Capacity | >10 years of raw temperature data (immutable export via USB flash drive) |
| Audit Trail | Up to 16,000 entries (user actions & alarms, stored internally and exportable via USB, read-only) |
| User Management | 5 configurable user accounts with role-based permissions |
| Multi-point Temperature Calibration | Supported |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Refrigerant | Eco-friendly R134a or equivalent |
| Insulation | Monolithic polyurethane foam injection (≥80 mm thickness) |
| Door Design | Dual-door structure with tempered glass inner door |
| Communication Interfaces | USB, RS-232, RS-485 |
| Language Support | Switchable English/Chinese UI |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating Power | 1000 W |
| Ambient Operating Conditions | 5–35 °C, recommended at 25 ±2 °C |
| Safety Features | Auto-restart after power failure, over-temperature alarm, door-open alarm, compressor high-pressure protection, leakage current protection, sensor fault detection |
| Standard Shelving | 2 stainless steel shelves (optional expansion) |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | CNT-150 |
| Cooling Method | Compressor-based refrigeration |
| Air Circulation | Forced convection |
| Temperature Range | −10 °C to +85 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤0.8 °C at 40 °C |
| Chamber Volume | 150 L |
| External Dimensions (W×H×D) | 780 × 1200 × 802 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating Power | 1000 W |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM, Germany |
| Refrigerant | Eco-friendly R134a or equivalent |
| Temperature Sensor | HERAEUS platinum RTD (Pt100) |
| Insulation | Monolithic polyurethane foam (≥80 mm thickness) |
| Display | 4.3″ color TFT touchscreen |
| Data Logging | ≥3 years of timestamped temperature & alarm logs (U-disk export, write-protected) |
| Audit Trail | ≥16,000 entries (user actions, alarms, parameter changes) |
| User Management | 5 configurable roles with granular access control |
| Communication Ports | USB, RS-232, RS-485 |
| Language Interface | Switchable English/Chinese |
| Safety Features | Over-temperature cut-off, compressor high-pressure protection, door-open alarm, sensor fault detection, leakage current protection, auto-restart after power recovery |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | CNT-150 |
| Temperature Range | −10 °C to 85 °C |
| Temperature Uniformity | ±0.5–1.0 °C (at 15–45 °C) |
| Humidity Control | None |
| Chamber Volume | 150 L |
| Control System | PID + Fuzzy Logic |
| Display | 4.3″ Full-Color Touchscreen LCD |
| Data Logging Capacity | 250,000 entries (1-min interval, immutable export via USB flash drive) |
| Audit Trail | 16,000 immutable operator & alarm logs (USB export) |
| User Management | 5 configurable roles with granular permissions |
| Compressor | SECOP (Danfoss Group), R134a refrigerant |
| Condenser Fan | EBM-Papst (Germany) |
| Temperature Sensor | Heraeus (Germany) |
| Insulation | Monolithic polyurethane foam injection |
| Chamber Viewing | Tempered glass inner door + silicone-sealed 50 mm access port |
| Communication Interfaces | USB, RS-232, RS-485 |
| Language Support | English / Chinese toggle |
| Power Supply | AC 220 V, 50/60 Hz |
| Safety Features | Over-temperature alarm, compressor overpressure protection, door-open alert, sensor fault detection, leakage current protection, auto-restart after power interruption |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | CNT150 |
| Temperature Range | −10 °C to 90 °C |
| Temperature Uniformity | ±0.5 °C (at 20–45 °C) |
| Humidity Control | None |
| Chamber Volume | 150 L |
| Control System | PID + Fuzzy Logic |
| Display | 4.3″ Color TFT Touchscreen |
| Data Logging | ≥3 years (immutable, USB export) |
| Audit Trail | 16,000 entries (immutable, USB export) |
| User Management | Up to 5 configurable roles |
| Compressor | SECOP (Danfoss), Germany |
| Condenser Fan | EBM, Germany |
| Refrigerant | Eco-friendly R134a or equivalent |
| Sensor | HERAEUS Platinum RTD (Class A, ±0.1 °C accuracy) |
| Insulation | Monolithic polyurethane foam (≥80 mm thickness) |
| Port | Ø50 mm silicone grommet (right side) |
| Door | Dual-glass structure with tempered inner door |
| Communication | USB, RS-232, RS-485 |
| Language | Switchable English/Chinese UI |
| Power Supply | AC 220 V, 50/60 Hz |
| Safety Features | Over-temperature alarm, door-open alert, compressor overpressure protection, leakage current protection, sensor fault detection, auto-restart after power recovery |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | HKC 85 |
| Temperature Range | Ambient +5°C to 70°C |
| Control Method | PID Fuzzy Logic |
| Temperature Uniformity | ±0.5–0.8°C |
| Temperature Fluctuation | ±0.2°C |
| Setpoint Resolution | 0.1°C |
| Chamber Volume | 85 L |
| Interior Dimensions (W×H×D) | 480 × 555 × 320 mm |
| Exterior Dimensions (W×H×D) | 600 × 865 × 570 mm |
| Net Weight | 60 kg |
| Heating Power | 1600 W |
| Interior Material | Thickened SUS304 Stainless Steel |
| Air Circulation | Forced Convection |
| Display | LCD Panel |
| Safety Features | Leakage Protection, Over-Temperature Cut-Off, Door-Open Alarm, Sensor Fault Detection |
| Air Inlet/Outlet | Two Bottom Inlets, One Top Exhaust |
| Shelf Configuration | Two Removable Stainless Steel Shelves |
| Power Supply | AC 220 V, 50/60 Hz |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | HKC-150 |
| Temperature Range | Ambient +5°C to 70°C |
| Control Method | PID Fuzzy Logic (Fixed & Programmable Modes) |
| Uniformity | ±0.5–0.8°C |
| Stability | ±0.2°C |
| Chamber Volume | 150 L |
| Inner Chamber Dimensions (W×H×D) | 550 × 650 × 425 mm |
| Exterior Dimensions (W×H×D) | 670 × 960 × 675 mm |
| Net Weight | 85 kg |
| Heating Power | 2000 W |
| Inner Material | Thickened SUS304 Stainless Steel |
| Insulation | High-Density Polyurethane Foam (≥80 mm) |
| Air Circulation | Forced Convection with Adjustable Fan Speed |
| Display | Backlit LCD Panel |
| Air Inlet/Outlet | Two Bottom Inlets, One Top Exhaust |
| Safety Features | Leakage Protection, Over-Temperature Cut-off, Door-Open Alarm, Sensor Fault Detection |
| Shelf Configuration | Three Removable SUS304 Shelves |
| Leveling | Adjustable Feet with Heavy-Duty Casters |
| Air Exchange | Fresh Air Intake System with Filtered Pathway |
| Compliance | Designed per GB/T 23792–2009 (Chinese National Standard for Laboratory Incubators), Compatible with GLP Environment Requirements |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | HKC-250 |
| Convection Type | Forced Air |
| Control Method | Digital PID Temperature Control |
| Temperature Range | Ambient +5°C to 70°C |
| Temperature Control Accuracy | ±0.1°C |
| Temperature Uniformity | <1.0°C |
| Temperature Fluctuation | ±0.1°C |
| Chamber Volume | 250 L |
| Heating Power | 2500 W |
| Inner Chamber Dimensions (W×H×D) | 700 × 760 × 470 mm |
| Exterior Dimensions (W×H×D) | 820 × 1070 × 720 mm |
| Net Weight | 115 kg |
| Inner Material | Thickened SUS304 Stainless Steel |
| Insulation | High-Density Polyurethane Foam (≥80 mm) |
| Air Inlet/Outlet | Two bottom inlets, one top exhaust |
| Safety Features | Leakage protection, over-temperature cutoff, door-open alarm, sensor fault detection |
| Shelf Configuration | Three removable stainless steel shelves |
| Power Supply | AC 220 V, 50/60 Hz |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | TPC 1000 |
| Refrigeration System | Inverter-driven SECOP (Danfoss) compressor with R404a refrigerant |
| Humidity Reservoir | External water tank |
| Temperature Range (with humidity control) | −10 °C to 85 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Chamber Volume | 1000 L |
| Control Method | PID + fuzzy logic algorithm |
| Display | 7-inch full-color TFT touch screen |
| Data Logging | Internal non-volatile memory (≥10 years of continuous data), USB export with write-protected binary format |
| Audit Trail | 16,000 entries (user actions, alarms, system events), immutable export via USB |
| User Management | Up to 5 configurable accounts with role-based permissions |
| Sensor System | HERAEUS platinum RTD temperature sensors |
| Insulation | Monolithic polyurethane foam injection (≥120 mm thickness, thermal conductivity ≤0.022 W/m·K) |
| Airflow Design | Dual-side aerodynamic ventilation ports (Ø50 mm) |
| Door Structure | Double-door configuration with tempered inner glass door |
| Communication Interfaces | RS232, RS485, USB-B (for data export and EMS integration) |
| Power Supply | AC 220 V ±10 %, 50/60 Hz |
| Safety Protections | Over-temperature cutoff, refrigerant high-pressure shutdown, leak current protection, low-water alarm, door-open alert, sensor fault detection, auto-restart after power recovery |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | TPC 460 |
| Refrigeration | Inverter-driven SECOP (Danfoss) compressor |
| Humidity Reservoir | External water tank |
| Temperature Range (dry) | −10 °C to 85 °C |
| Temperature Uniformity (15–45 °C) | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Chamber Volume | 460 L |
| Insulation | High-density polyurethane integral foaming |
| Cooling Refrigerant | R404a |
| Heating & Humidification Power | 2300 W |
| Compressor Power | 550 W |
| Sensor System | HERAEUS temperature sensor + E+E Electronics capacitive humidity sensor |
| Display | 7-inch full-color TFT touch screen |
| Data Logging | ≥10 years internal storage, USB export (read-only, tamper-proof) |
| Audit Trail | 16,000+ immutable entries (user actions, alarms, system events) |
| User Management | 5 configurable roles with hierarchical permissions |
| Airflow Design | Dual-side aerodynamic 50 mm ports |
| Door Structure | Double-door, inner tempered glass viewing window |
| Communication Interfaces | USB, RS232, RS485 (EMS integration ready) |
| Compliance Support | GLP/GMP-aligned operation logs, 21 CFR Part 11–compatible data integrity architecture |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | TPC 760 |
| Refrigeration System | Inverter-driven SECOP (Danfoss) compressor with R404a refrigerant |
| Humidity Reservoir | External water tank |
| Temperature Range (with humidification) | −10 °C to 85 °C |
| Temperature Range (without humidification) | −10 °C to 85 °C |
| Temperature Uniformity (at 25 °C, empty chamber) | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Chamber Volume | 760 L |
| Insulation | High-density polyurethane foam, one-shot foaming process |
| Airflow Design | Dual-side aerodynamic ventilation ports (Ø50 mm) |
| Viewing Window | Tempered glass inner door |
| Control System | 7-inch color TFT touch screen with PID + fuzzy logic algorithm |
| Data Logging | Internal non-volatile memory (≥10 years of continuous 1-min interval logging), USB export (read-only, tamper-proof), audit trail (16,000 entries), user permission management (5 configurable roles) |
| Compliance Support | GLP-compliant data integrity, 21 CFR Part 11-ready audit trail and electronic signature capability (via optional software module), ISO 17025 traceable calibration support |
| Brand | Alison (ALISN) |
|---|---|
| Origin | Shanghai, China |
| Model | TPC-250 |
| Refrigeration System | Inverter-driven Danfoss (SECOP) compressor with R134a refrigerant |
| Humidity Reservoir | External water tank |
| Temperature Range (with humidification) | 10–85 °C |
| Temperature Range (dry operation) | −10–85 °C |
| Temperature Uniformity (15–45 °C) | ±0.2–0.5 °C |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Internal Volume | 250 L |
| Insulation | High-density polyurethane foam, one-shot foaming process |
| Display | 7-inch full-color TFT touch screen |
| Control Algorithm | PID + fuzzy logic hybrid control |
| Data Logging | 3-year capacity (1-min interval), stored internally and exportable via USB (read-only, tamper-proof) |
| Audit Trail | 16,000 entries (user actions, alarms, system events), non-erasable, USB-exportable |
| User Management | Up to 5 configurable accounts with role-based permissions |
| Sensor System | HERAEUS platinum RTD temperature sensors |
| Airflow Design | Dual-side aerodynamic 50-mm diameter ventilation ports |
| Door Structure | Double-door system with inner tempered glass door |
| Communication Interfaces | USB, RS-232, RS-485 (EMS integration ready) |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating & Humidification Power | 2200 W |
| Compressor Power | 250 W |
| Safety Features | Over-temperature alarm, low-water alarm, door-open alarm, sensor fault detection, compressor high-pressure protection, earth-leakage protection, auto-restart after power recovery |
| Brand | Alphavita |
|---|---|
| Model | GDF-U780VHE |
| Temperature Range | -40°C to -86°C (adjustable in 0.1°C increments, ambient 10–30°C) |
| External Dimensions (W×D×H) | 1030 × 875 × 1990 mm |
| Internal Dimensions (W×D×H) | 890 × 600 × 1380 mm |
| Net Volume | 736 L |
| Net Weight | 312 kg |
| Power Consumption | 1200 W |
| Refrigerant | Hydrocarbon (HC), charge <150 g |
| Door Configuration | Optional triple or quadruple inner doors |
| Control | Delayed start (0–30 min programmable) |
| Insulation | ≥30 mm foamed inner door, quad-layer door gasket system |
| Brand | ANAYN |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Air-Jacketed Tri-Gas Incubator |
| O₂ Concentration Range | 1–95% (v/v) |
| CO₂ Concentration Range | 0–20% (v/v) |
| Temperature Control Range | +3°C to +60°C |
| Temperature Uniformity | ±0.3°C (@37°C) |
| Temperature Stability | ±0.2°C (@37°C) |
| Humidity Level | ≥90% RH (passive water-jacket evaporation, uncontrolled) |
| Chamber Volume | 80 L |
| External Dimensions (W×D×H) | 640 × 650 × 1040 mm |
| Internal Dimensions (W×D×H) | 400 × 400 × 500 mm |
| Display | 5.0-inch capacitive touchscreen |
| CO₂ Sensor | NDIR infrared sensor |
| O₂ Sensor | Imported electrochemical sensor |
| Temperature Sensor | PT100 platinum resistance sensors (5-wall + door independent control) |
| Sterilization | UV lamp (programmable on/off) |
| Power Consumption | 400 W |
| Gas Inlets | Dedicated high-purity N₂, O₂, and CO₂ ports with solenoid valve control |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Advanced Instruments, Inc. |
| Type | Imported |
| Model | Anoxomat III |
| Pricing | Upon Request |
| Key Features | IR-based CO₂ sensing |
|---|---|
| Temperature range | Rt+3–60 °C |
| Temp. uniformity | ±0.3 °C @ 37 °C |
| CO₂ range | 0–20% (±0.1% accuracy) |
| O₂ range | 1–95% (±0.3% accuracy) |
| External dimensions | 550×530×890 mm |
| Construction | 304 stainless steel interior |
| Gas supply logic | N₂/CO₂ blending for hypoxia (<19.8% O₂) |
| Compliance | Designed for ISO 13485-aligned lab environments, GLP-compliant operation support |
| Brand | ANYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | CYSQ-80 |
| Type | Air-Jacketed Tri-Gas Incubator |
| O₂ Range | 1–95% (v/v) |
| O₂ Accuracy | ±0.3% (v/v) |
| Temperature Range | +3 to +60 °C |
| Temp Uniformity | ±0.3 °C (@37 °C) |
| Temp Stability | ±0.2 °C (@37 °C) |
| CO₂ Range | 0–20% (v/v) |
| CO₂ Accuracy | ±0.1% (v/v) |
| Humidity | ≥90% RH (passive water-jacket evaporation, uncontrolled) |
| Chamber Volume | 80 L (customizable) |
| CO₂ Sensor | IR-based |
| O₂ Sensor | Electrochemical (imported) |
| Temp Sensor | PT100 (imported) |
| Sterilization | UV lamp |
| Power | 400 W |
| Chamber Dimensions (W×D×H) | 400×400×500 mm |
| External Dimensions (W×D×H) | 540×520×790 mm |
| Shelf | 1 stainless steel shelf (304) |
| Compliance | Designed for GLP-aligned cell culture workflows |
| Brand | ANYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | CYSQ-80-III |
| Chamber Volume | 80 L |
| Temperature Range | +3 to +60 °C |
| Temperature Uniformity | ±0.3 °C (@37 °C) |
| Temperature Stability | ±0.2 °C (@37 °C) |
| CO₂ Range | 0–20 % vol, Accuracy: ±0.1 % |
| O₂ Range | 1–95 % vol, Accuracy: ±0.3 % |
| Humidity | ≥90 % RH (passive water-jacket evaporation, uncontrolled) |
| Gas Control Method | IR sensor for CO₂ |
| Sterilization | UV lamp |
| Display | 5.0-inch capacitive touchscreen |
| Dimensions (W×D×H) | 640 × 650 × 1040 mm |
| Power Consumption | 400 W |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water-Jacketed Tri-Gas Incubator |
| O₂ Range | 1–95% ±0.3% |
| CO₂ Range | 0–20% ±0.1% |
| Temperature Range & Stability | RT+3°C to 60°C |
| Humidity | ≥90% RH (natural evaporation from 304 stainless steel water pan) |
| Capacity | 100 L |
| Dimensions (W×D×H) | 550 × 530 × 890 mm |
| Display | Capacitive Touchscreen Interface |
| Gas Control Logic | Dual-gas mixing with N₂/O₂/CO₂ prioritization for cross-interference minimization |
| Sterilization | UV lamp + optional 90°C high-temperature humidified sterilization |
| Air Circulation | Micro-airflow system with six-sided chamber heating + independent door temperature control |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AYJ-KB160B |
| Instrument Type | Water-Jacketed Tri-Gas Incubator |
| O₂ Concentration Range | 1–95% ±0.3% |
| Temperature Control Range & Accuracy | RT+3°C to 60°C |
| Temperature Uniformity | ±0.3°C (@37°C) |
| CO₂ Concentration Range & Accuracy | 0–20% ±0.1% |
| Humidity Control | ≥90% RH (natural evaporation) |
| Chamber Capacity | 160 L |
| External Dimensions | 640 × 620 × 940 mm |
| Standard Configuration | 5.7-inch color touch screen |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Model | AYJ-KB50B |
| Type | Water-Jacketed Tri-Gas Incubator |
| Chamber Capacity | 50 L |
| Dimensions (W×D×H) | 430 × 460 × 650 mm |
| Temperature Range & Accuracy | RT+3°C to 60°C |
| Temperature Uniformity | ±0.3°C @ 37°C |
| CO₂ Control Range & Accuracy | 0–20% ±0.1% |
| O₂ Control Range & Accuracy | 1–95% ±0.3% |
| Humidity Control | ≥90% RH (natural evaporation from stainless steel water pan) |
| Gas Sensors | IR-based CO₂ sensor |
| Display | Touchscreen interface |
| Sterilization | UV lamp |
| Construction | 304 stainless steel interior with rounded corners |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Model | AYJ-KB50B |
| Type | Water-jacketed tri-gas incubator |
| Capacity | 50 L |
| Dimensions (W×D×H) | 430 × 460 × 650 mm |
| Temperature Range & Accuracy | RT+3°C to 60°C |
| Temperature Uniformity | ±0.3°C (@37°C) |
| CO₂ Control Range & Accuracy | 0–20% vol, ±0.1% |
| O₂ Control Range & Accuracy | 1–95% vol, ±0.3% |
| Humidity | ≥90% RH (natural evaporation from stainless steel water pan) |
| Display | Touchscreen interface |
| Gas Sensors | IR-based CO₂ sensor |
| Chamber Material | 304 stainless steel with rounded corners |
| Sterilization | UV lamp |
| Safety | Independent over-temperature cut-off relay, dual-limit thermal protection, automatic gas shutoff upon door opening |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Model | AYJ-KB80B |
| Type | Water-jacketed tri-gas incubator |
| O₂ Range | 1–95% ±0.3% |
| CO₂ Range | 0–20% ±0.1% |
| Temperature Range | RT+3–60°C |
| Temp Uniformity | ±0.3°C @ 37°C |
| Humidity | ≥90% RH (natural evaporation from stainless steel water pan) |
| Capacity | 80 L |
| Dimensions (W×D×H) | 540×520×790 mm |
| Display | Touchscreen interface |
| Gas Sensors | IR-based CO₂ sensor |
| Sterilization | UV lamp |
| Construction | 304 stainless steel interior with rounded corners |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Model | HWS-1000 |
| Heating Method | Air-Jacketed |
| Cooling Method | Compressor-Based Refrigeration |
| Humidification System | External Water Reservoir with Ultrasonic Humidifier |
| Temperature Range (with Humidification) | 5–50 °C |
| Temperature Range (without Humidification) | 5–50 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 40–95 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 1000 L |
| External Dimensions (W×D×H) | 1210 × 640 × 1850 mm |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HWS-1250 |
| Heating Method | Air-Jacketed Heating |
| Cooling Method | Compressor-Based Refrigeration |
| Humidification Water Tank | External Reservoir |
| Temperature Range (with Humidification) | 5–50 °C |
| Temperature Range (without Humidification) | 5–50 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 40–95 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 1250 L |
| External Dimensions (W×D×H) | 1790 × 670 × 1830 mm |
| Brand | AnYuJie |
|---|---|
| Origin | Zhejiang, China |
| Model | HWS-1500 |
| Heating Method | Air-Jacketed |
| Cooling Method | Compressor-Based Refrigeration |
| Humidification System | External Water Reservoir with Ultrasonic Humidifier |
| Temperature Range (with Humidification) | 5–50 °C |
| Temperature Range (without Humidification) | 5–50 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 40–95 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 1500 L |
| External Dimensions (W×D×H) | 1890 × 760 × 1830 mm |