Melt Flow Indexer
Filter
Showing 1–30 of 61 results
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BRXZZ |
| Price | USD 3,500 (FOB Beijing) |
| Temperature Range | Ambient to 400 °C |
| Temperature Stability | ±0.1 °C |
| Temp. Recovery Time | < 4 min |
| Cut Count | 1–99 |
| Cut Interval | 10–600 s |
| Continuous Operation | >10,000 h |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Die Diameter | Φ2.095 ±0.005 mm |
| Die Length | 8.000 ±0.025 mm |
| Barrel ID | Φ9.550 ±0.025 mm |
| Barrel Length | 152.0 ±0.1 mm |
| Piston Head Diameter | 9.475 ±0.015 mm |
| Piston Head Length | 6.350 ±0.100 mm |
| Standard Loads (8 levels) | 0.325 kg (3.187 N) to 21.600 kg (211.82 N) |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A-Melt |
| Temperature Range | 50–400 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.2 °C (barrel zone) |
| Barrel ID | 9.55 ±0.007 mm |
| Barrel Material | Nitrided steel, hardness 52–55 HRC |
| Maximum Plunger Travel | 80 mm |
| Cutting Interval | 3–300 s (touch-configurable) |
| Data Points per Test | Up to 100 |
| Display | 5-inch capacitive touchscreen |
| Interface | USB for optional PC software and data export |
| Compliance | ASTM D1238, ISO 1133, GB/T 3682 |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A-MeP |
| Pricing | Upon Request |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MELTS |
| Pricing | Upon Request |
| Brand | Beiguang Jingyi / All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HRZ-400B |
| Price | USD 1,350 (FOB Beijing) |
| Temperature Control Range | Ambient to 450 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Max Power Consumption | ≤500 W |
| Temperature Recovery Time | ≤4 min |
| MFR Range | 0.03–450 g/10 min |
| Piston Displacement Accuracy | ±0.1 mm |
| Standard Barrel ID | 9.55 ±0.025 mm |
| Piston Head Diameter | 9.475 ±0.015 mm |
| Die Orifice Options | 2.095 ±0.005 mm & 1.18 ±0.01 mm |
| Standard Weights | 0.325 kg, 0.875 kg, 0.960 kg, 1.200 kg, 1.640 kg (±0.5% tolerance) |
| Brand | Beijing North Guang Precision Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HRZ-400B |
| Temperature Control Range | Ambient to 450 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Max Power Consumption | ≤500 W |
| Temperature Recovery Time | ≤4 min |
| Piston Stroke Detection (for MVR) | 30 mm |
| Displacement Accuracy | ±0.1 mm |
| MFR/MVR Test Range | 0.03–450 g/10 min |
| Barrel ID | 9.55 ± 0.025 mm |
| Piston Head Diameter | 9.475 ± 0.015 mm |
| Piston Head Length | 6.35 ± 0.1 mm |
| Die Orifice | 2.095 ± 0.005 mm (standard) |
| Standard Weights | 0.325 kg, 0.875 kg, 0.960 kg, 1.200 kg, 1.640 kg (±0.5% tolerance) |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Model | SRZ-400A |
| Standards Compliance | GB/T 3682–2000 Method A, ISO 1133:1997 |
| Temperature Range | 80–400 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Barrel ID | 9.550 ± 0.025 mm |
| Piston Head Diameter | 9.475 ± 0.015 mm |
| Piston Head Length | 6.35 ± 0.1 mm |
| Die Capillary Diameter | 2.095 ± 0.005 mm |
| Stroke Interval | 30 mm |
| Position Control Accuracy | ±0.1 mm |
| Max Power Consumption | < 500 W |
| Temperature Recovery Time | ≤ 4 min |
| Net Weight | 50 kg |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Model | SRZ-400E |
| Temperature Range | 80–400 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Die Diameter | 2.095 ± 0.005 mm |
| Barrel Bore | 9.550 ± 0.025 mm |
| Piston Head Diameter | 9.475 ± 0.015 mm |
| Piston Head Length | 6.35 ± 0.1 mm |
| Stroke Detection Accuracy | ±0.1 mm |
| Standard Spacing Between Cut Positions | 30 mm |
| Max Power Consumption | <500 W |
| Temperature Recovery Time | 4 min |
| Weight | 50 kg |
| Accuracy Class | Class 1 |
| Compliance | GB/T 3682–2000 Method A, ISO 1133:1997 |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Model | SRZ-400F |
| Temperature Range | 80–400 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Barrel ID | 9.550 mm ±0.025 mm |
| Piston Head OD | 9.475 mm ±0.015 mm |
| Piston Length | 6.35 mm ±0.1 mm |
| Die Capillary ID | 2.095 mm ±0.005 mm |
| Load Positions | 30 mm spacing |
| Power Supply | AC 220 V, ≤0.5 kW |
| Weight | 50 kg |
| Dimensions (L×W×H) | 460×280×415 mm |
| Accuracy Class | Class 1 |
| Standard Compliance | GB/T 3682–2000 (Method A), ISO 1133:1997 |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Model | SRZ-400H |
| Temperature Range | 80–400 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Die Orifice Diameter | 2.095 mm ± 0.005 mm |
| Barrel Bore Diameter | 9.550 mm ± 0.025 mm |
| Piston Head Diameter | 9.475 mm ± 0.015 mm |
| Piston Head Length | 6.35 mm ± 0.1 mm |
| Standard Load Masses | 0.325 kg, 0.875 kg, 0.960 kg, 1.200 kg, 1.640 kg |
| Cut Distance Interval | 30 mm |
| Power Supply | AC 220 V, ≤0.5 kW |
| Weight | 50 kg |
| Dimensions (L×W×H) | 460 mm × 280 mm × 415 mm |
| Compliance | GB/T 3682–2000, ISO 1133:1997 |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Model | SRZ-400H |
| Temperature Range | 80–400 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Die Orifice Diameter | 2.095 mm ± 0.005 mm |
| Barrel Bore Diameter | 9.550 mm ± 0.025 mm |
| Piston Head Diameter | 9.475 mm ± 0.015 mm |
| Piston Head Length | 6.35 mm ± 0.1 mm |
| Standard Load Positions | 30 mm spacing |
| Power Consumption | ≤0.5 kW |
| Recovery Time after Load Change | 4 min |
| Weight | 50 kg |
| Dimensions (L×W×H) | 460 × 280 × 415 mm |
| Supply | AC 220 V |
| Accuracy Class | Class 1 |
| Compliance | GB/T 3682–2000 (Method A), ISO 1133:2011, ASTM D1238 |
| Brand | Davenport |
|---|---|
| Origin | USA |
| Model | MFI-10 |
| Standards Compliance | ISO 1133, ASTM D1238 (Methods A & B) |
| Measurement Outputs | Melt Flow Index (MFI), Melt Flow Rate (MFR), Melt Volume Rate (MVR), Melt Density/Viscosity Derivation |
| Configurable Test Methods | Up to 10 user-defined test protocols |
| Optional Accessories | Automatic timer, motorized weight loading system, automatic specimen cutter, corrosion-resistant barrel assembly, displacement sensor |
| Display | Backlit LCD with step-by-step guided operation and audible prompts |
| Software Integration | NEXYGEN Data Analysis Software (optional) |
| System Architecture | Modular, field-upgradable platform supporting manual or fully automated operation |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DRK 208 |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Barrel Inner Diameter | 9.55 ±0.025 mm |
| Barrel Length | 160 mm |
| Piston Head Diameter | 9.475 ±0.01 mm |
| Die Inner Diameter | 2.095 mm |
| Die Length | 8 ±0.025 mm |
| Displacement Measurement Range | 0–30 mm |
| Displacement Accuracy | ±0.05 mm |
| MFR/MVR Measurement Accuracy | ±10% |
| Power Supply | 220 V ±10%, 50 Hz |
| Heating Power | 550 W |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DRK208 |
| Price | USD 7,000 (FOB Qingdao) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XNR-400C |
| Temperature Range | 50–300 °C |
| Temperature Accuracy | ±0.5 °C |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | XRL-400C |
| Price | USD 7,000 (FOB) |
| Measurement Range | MFR 0.01–600.00 g/10 min |
| Temperature Control Range | 50–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Display Resolution | 0.01 °C |
| Barrel ID | 9.55 ± 0.025 mm, Length: 160 mm |
| Piston Head Diameter | 9.475 ± 0.01 mm, Mass: 106 g |
| Die ID | 2.095 mm, Length: 8 ± 0.025 mm |
| Standard Loads | 0.325, 1.2, 2.16, 3.8, 5.0, 10.0, 21.6 kg (±0.5% accuracy) |
| Displacement Range | 0–30 mm, Accuracy: ±0.05 mm |
| Power Supply | 220 V ±10%, 50 Hz |
| Heating Power | 550 W |
| Dimensions (L×W×H) | 560 × 376 × 530 mm |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | XRL-400C |
| Test Method | Standard Gravimetric & Volumetric Extrusion |
| Type | Conventional Melt Flow Indexer |
| Temperature Range | 50–400 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Display Resolution | 0.01 °C |
| MFR Range | 0.01–600.00 g/10 min |
| MVR Range | 0.01–600.00 cm³/10 min |
| Melt Density Range | 0.001–9.999 g/cm³ |
| Barrel ID | 9.55 ± 0.025 mm, Length: 160 mm |
| Piston Head Diameter | 9.475 ± 0.01 mm, Mass: 106 g |
| Die ID | 2.095 mm, Length: 8 ± 0.025 mm |
| Standard Loads | 0.325, 1.2, 2.16, 3.8, 5.0, 10.0, 21.6 kg (±0.5% accuracy) |
| Displacement Measurement Range | 0–30 mm, Accuracy: ±0.05 mm |
| Power Supply | 220 V ± 10%, 50 Hz |
| Heating Power | 550 W |
| Dimensions (L×W×H) | 560 × 376 × 530 mm |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | GBB-R |
| Price | USD 3,650 (approx.) |
| Measurement Methods | Mass Flow Rate (MFR) and Volume Flow Rate (MVR) |
| MFR Range | 0–200 g/10 min |
| MVR Range | 0–41.81 cm³/10 min |
| Mass Accuracy | ±0.1 g/10 min |
| Temperature Control Range | Ambient to 300 °C |
| Temperature Stability | ±1 °C at 10 mm above die top (per ISO 1133-1) |
| Temperature Uniformity | ±1 °C (same location) |
| Displacement Resolution | 0.1 mm |
| Barrel Temperature Recovery Time | ≤4 min after loading |
| Die Dimensions | Ø2.095 ±0.005 mm × 8.000 ±0.025 mm |
| Barrel ID | Ø9.550 ±0.007 mm, L = 164 ±0.1 mm |
| Piston Diameter | Ø9.474 ±0.007 mm, L = 6.350 ±0.100 mm |
| Standard Loads | 0.325–21.6 kg (7 levels), Load Accuracy: ≤±0.5% |
| Timing Resolution | 0.1–999.9 s (auto-timed cutting) |
| Dimensions | 500 × 280 × 500 mm |
| Weight | 48 kg |
| Power | 600 W, 220 V, 50 Hz |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | MI-3 |
| Temperature Range | 60.00–400.00 °C (optional up to 500 °C) |
| Die Diameter | 2.095 ± 0.003 mm, Length: 8.00 ± 0.025 mm |
| Die Material | Tungsten Carbide |
| Piston Diameter | 9.48 ± 0.01 mm |
| Barrel ID | 9.555 ± 0.01 mm |
| Standard Weights | 1.200, 2.16, 3.8, 5.0, 10.0, 21.6 kg (±0.5 % tolerance) |
| Timer Resolution | < 0.001 s |
| MFR Range | 0.01 cm³/min to 2500 g/10 min (with die inserts) |
| Touchscreen | 5.7″ full-color capacitive display |
| Connectivity | Ethernet port for LIMS integration, dual USB ports |
| Compliance | ISO 1133, ASTM D1238 (Methods A, B, C) |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | MI-ROBO |
| Temperature Range | 60.00–400.00 °C (optional to 500.00 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Die Diameter | 2.095 ± 0.003 mm |
| Die Length | 8.00 ± 0.025 mm |
| Die Material | Tungsten Carbide |
| Piston Diameter | 9.48 ± 0.01 mm |
| Barrel ID | 9.555 ± 0.01 mm |
| Standard Weights | 1.200, 2.16, 3.8, 5.0, 10.0, 21.6 kg (±0.5 % tolerance) |
| Timer Resolution | < 0.001 s |
| Position Sensor Resolution | 0.012 mm/pulse |
| Test Capacity | Up to 30 consecutive tests |
| Display | 5.7" full-color LCD touchscreen |
| Software | MFR Professional with automated sequence programming, real-time monitoring, and GLP-compliant data export |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | MI2 Series (MI2.1, MI2.2, MI2.3) |
| Standards Compliance | ISO 1133, ASTM D1238 (Methods A, B, C), ASTM D3364 |
| Cylinder Bore Diameter | 9.555 ± 0.010 mm |
| Piston Diameter | 9.474 ± 0.007 mm |
| Die Capillary | 2.095 ± 0.005 mm × 8.00 ± 0.025 mm (Tungsten Carbide) |
| Temperature Range | 60–400 °C |
| Temp. Stability | < ±0.1 °C (over time) |
| Temp. Accuracy | ±0.01 °C (60–320 °C), ±0.1 °C (320–400 °C) |
| Load Masses | 1.20, 2.16, 3.8, 5.0, 10.0, 21.6 kg (±0.5 % tolerance) |
| Timer Resolution | 0.001 s |
| Display | 5.7″ full-color touchscreen |
| Connectivity | Ethernet (LIMS-ready), dual USB ports |
| Multi-unit Control | Up to 4 units per PC |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | MI40 |
| Control Interface | 5.7" touchscreen (bilingual: English/Chinese) |
| Load Application | Motor-driven force control up to 60 kg |
| Preload & Post-extrusion Force Control | Yes |
| Standard Weight Loading | ASTM-compliant砝码 set (1.200, 2.16, 3.8, 5.0, 10.0, 21.6 kg |
| Multi-load Testing | Up to 8 programmable weights |
| Barrel Rotation | 90° and 180° for loading/cleaning |
| Temperature Range | 60.00–400.00 °C (optional to 500.00 °C) |
| Die Dimensions | 2.095 ± 0.003 mm diameter, 8.00 ± 0.025 mm length |
| Die Material | Tungsten carbide |
| Piston Diameter | 9.48 ± 0.01 mm |
| Barrel ID | 9.555 ± 0.01 mm |
| Timing Resolution | < 0.001 s |
| Displacement Sensor | High-precision linear encoder |
| Cleaning Options | Rotating cleaning auger (optional), automated barrel cleaning module (optional) |
| Connectivity | Ethernet port for direct LIMS integration, dual USB ports (U-disk & printer) |
| Software Control | Single PC can manage up to four MI40 units |
| Compliance | ISO 1133, ASTM D1238 Method D, ASTM D3364 |
| Optional Modules | Auto-melt cutter, heated/unheated die plugs, nitrogen purge, die swell unit, semi-die, D-MELT melt extension rheology system, corrosion/wear-resistant barrels |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | MI40-AUTO |
| Compliance Standards | ISO 1133, ASTM D1238, ASTM D3364 |
| Automation Level | Fully automated with robotic sample handling, auto-loading, auto-cleaning |
| Measurement Types | Melt Volume Rate (MVR) and Melt Mass Rate (MFR) |
| Configuration | Modular, scalable platform supporting linear or circular instrument layouts |
| Target Materials | Thermoplastics, engineering resins, filled polymers, biopolymers |
| Software | Integrated control with audit trail, user access levels, and data export compliant with GLP/GMP requirements |
| Brand | GOTECH TESTING MACHINES CO., LTD. |
|---|---|
| Origin | Taiwan |
| Model | GT-7100-MIBH |
| Temperature Range | Ambient to 450 °C (dual-zone PID control, ±0.1 °C accuracy with overtemperature protection) |
| Load Masses | 1000 g, 1050 g, 1200 g, 2160 g, 3800 g, 5000 g, 10000 g, 12500 g, 21600 g (user-selectable combinations) |
| MFR/MVR/FRR Output | Optional thermal printer support |
| Automatic & Manual Cut-off | Adjustable timer range 0.1–999.9 s |
| Standard Orifice | ASTM D1238 / ISO 1133 / JIS K7210 / CNS 8516 compliant die (2.095 mm diameter × 8.00 mm length) |
| Sample Throughput Range | 0.15–900 g/10 min |
| Dimensions (W×D×H) | 600 × 510 × 760 mm |
| Weight | 55 kg (excl. weights) |
| Power Supply | 1-phase AC 220 V, 50/60 Hz, 5 A |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Hanatek MFI |
| Price | Upon Request |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HS-XNR-400A |
| Price Range | USD 150–15,000 (FOB) |
| Die Orifice Diameter | Φ2.095 ± 0.005 mm |
| Die Orifice Length | 8.000 ± 0.025 mm |
| Barrel Inner Diameter | Φ9.550 ± 0.007 mm |
| Barrel Length | 152.0 ± 0.1 mm |
| Piston Head Diameter | 9.474 ± 0.007 mm |
| Piston Head Length | 6.350 ± 0.100 mm |
| Temperature Range | Ambient to 450 °C |
| Temperature Stability | ±0.2 °C |
| Operating Interface | Keypad Input |
| Display | LCD Screen |
| Reporting | Integrated Thermal Printer |
| Material Feed Method | Manual Loading |
| Melt Cutting Modes | Manual / Time-Controlled / Automatic |
| Test Principle | Gravimetric (MFR, ASTM D1238 / ISO 1133 Compliant) |
| Standard Load Masses (8 Levels) | 0.325 kg, 1.2 kg, 2.16 kg, 3.8 kg, 5.0 kg, 10.0 kg, 12.5 kg, 21.6 kg |
| Die Material | Tungsten Carbide |
| Calibration Compliance | GB/T 3682–2000, ISO 1133:1997, ASTM D1238–2023 |
| Brand | IDM |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | M0004 |
| Price | USD 70,000 (FOB Qingdao) |
| Temperature Control Range | 100–300 °C ±1 °C |
| Barrel Dimensions | Ø50.8 mm (OD) × Ø9.55 mm (ID) × 162 mm (L) |
| Die Specifications | Tungsten Carbide, Ø9.47 mm (OD), Ø2.096 mm (ID) × 8 mm (L) |
| Standard Compliance | ASTM D1238 (Procedure A), ISO 1133, BS 2782-1050 |
| Power Supply | 220/240 VAC @ 50 Hz or 110 VAC @ 60 Hz (customizable) |
| Dimensions (H×W×D) | 480 × 430 × 270 mm |
| Weight | 27 kg |
| Brand | INSTRON |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | CEAST MFi Series Melt Flow Indexer |
| Pricing | Available Upon Request |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-280 |
| Temperature Control Range | 50–400 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Die Capillary Inner Diameter | 2.095 ±0.005 mm |
| Barrel Inner Diameter | 9.550 ±0.025 mm |
| Piston Head Diameter | 9.475 ±0.01 mm |
| Piston Head Length | 6.35 ±0.1 mm |
| Piston Travel Distance | 30 mm |
| Position Detection Accuracy | ±0.1 mm |
| Temperature Recovery Time | ≤4 min |
| Max Power Consumption | ≤500 W |
| Standard Weights | 0.325 kg (with piston rod), 0.875 kg, 0.96 kg, 1.2 kg, 1.64 kg |
| Display | LCD with Chinese interface |
| Functions | Automatic timing, automatic cutting, thermal printing |
| Key | Brand: Jiubin Instruments |
|---|---|
| Model | JB-280B |
| Origin | Shanghai, China |
| Temperature Range | 50–400 °C |
| Temperature Accuracy | ±0.2 °C |
| Display Resolution | 0.1 °C |
| Die Diameter | 2.095 ±0.005 mm |
| Barrel ID | 9.550 ±0.025 mm |
| Piston Head OD | 9.475 ±0.01 mm |
| Piston Length | 6.35 ±0.1 mm |
| Stroke Detection Range | 30 mm |
| Displacement Accuracy | ±0.1 mm |
| Standard Load Levels | 3.185 N, 11.76 N, 21.168 N, 37.24 N, 49 N |
| Max Power Consumption | ≤500 W |
| Temperature Recovery Time | 4 min |