Cell Separation and Extraction Instrument
Filter
Showing all 23 results
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuLift |
| Pricing | Upon Request |
| Separation Method | Automated |
| Microscope Platform | Olympus IX73 or Nikon Ti2 base |
| IR Capture Laser | 808 nm solid-state, adjustable power |
| UV Cutting Laser | 355 nm & 349 nm diode-pumped Q-switched solid-state, tunable current & pulse frequency |
| Illumination | 5W 24-LED ring light |
| Objectives | Olympus PLAPON/PLANAPO 2×, 4×, 10×, 20×, 40×, 60×, 100× (dry) |
| Stage | Motorized X/Y stage with 0.25 µm homing accuracy & bidirectional repeatability |
| Camera | Dual 5 MP CMOS (color & monochrome), 75 fps at full resolution, large FOV, low-noise |
| Contrast Mode | Brightfield |
| Software Interface | Proprietary LCM control suite with intuitive GUI |
| Brand | ANGLE |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Parsortix PR1 |
| Pricing | Available Upon Request |
| Separation Method | Fully Automated Microfluidic-Based Capture |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Co., Ltd. |
| Type | Imported Instrument |
| Model | AS ONE Cell Picking System |
| Separation Method | Fully Automated Microfluidic Single-Cell Isolation |
| Cell Viability | 60–90% |
| Chip Format | Array of >100,000 Microwells (Ø ≈ 10 µm) |
| Detection Mode | Fluorescence Intensity + Brightfield Imaging |
| Recovery Mechanism | Glass Capillary-Based Contact-Free Aspiration |
| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Omics Bundle |
| Separation Method | Automated |
| Cell Viability (%) | ≥90% |
| Compatibility | Requires Integration with VIA Freeze™ Uno Controlled-Rate Freezer |
| Intended Use | Research Use Only (RUO), Not for Diagnostic Purposes |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FFX-TG |
| Price Range | USD 13,500 – 40,500 (FOB Hamburg) |
| Separation Method | Fully Automated |
| Leukocyte (Nucleated Cell) Recovery Rate | ≥95% |
| Cell Viability | ≥90% |
| Sample Throughput | Up to 4 independent tissue samples per run |
| Tissue Input Mass | 10–300 mg |
| Processing Time | 2–3 minutes per sample |
| Rotor-Stator Gap | 100 µm |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | HI-9 |
| Compatible Capillary Outer Diameter | 1.0 mm |
| Weight | 18.6 g |
| Length | 155 mm |
| Includes | Silicone Rubber Gasket (HI01PK01), Cleaning Rod |
| Mounting Type | Standard Connector-Based Fixture with Rotatable HIR Clamp |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | HIC-1.2 |
| Compatible Instruments | HI-7, HI-9 Micromanipulators |
| Outer Diameter Compatibility | 1.2 mm |
| Seal Material | Silicone Rubber |
| Dimensions (Cap) | 20 × 5 × 5 mm |
| Weight | 1 g |
| Package Includes | Single cap with integrated silicone gasket (HI01PK01) |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | HIC-1.5 |
| Compatible Instruments | HI-7, HI-9 Micromanipulators |
| Cap Outer Diameter | 1.5 mm |
| Silicone Gasket Included | HI01PK04 (20 × 5 × 5 mm, 1 g) |
| Brand | Miltenyi Biotec |
|---|---|
| Origin | Germany |
| Model | autoMACS® Pro |
| Automation Level | Fully Automatic |
| Sample Throughput | Up to 6 × 5 mL, 5 × 15 mL, or 3 × 50 mL tubes per run |
| Max Total Cells per Sample | 4 × 10⁹ |
| Max Magnetically Labeled Cells per Sample | 2 × 10⁸ |
| Sample Volume Range | 0.2–50 mL |
| Compatible Starting Materials | Whole blood, PBMCs, bone marrow, dissociated tissues, tumor digests, cultured cells (primary & cell lines) |
| Species Compatibility | Human, mouse, rat, non-human primates, and others via indirect MicroBeads |
| Column Types | Reusable autoMACS Columns (single or dual configuration) |
| Separation Modes | Positive selection, untouched isolation, depletion |
| Regulatory Compliance | Designed for GLP-compliant workflows |
| Dimensions (w × d × h) | 605 × 343 × 392.5–454 mm (with MiniSampler: 605 × 455 × 392.5–454 mm) |
| Cooling System | Integrated Chill Racks (2–8 °C sample/ reagent storage) |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | ClonePix 2 |
| Pricing | Available upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer | Molecular Devices |
| Product Type | Imported Instrument |
| Model | DispenCell |
| Separation Method | Automated Impedance-Based Dispensing |
| Certifications | Animal-Origin-Free & Cytotoxicity-Tested Disposable Tips |
| Software | DispenSoft v3.x (with Audit Trail, Electronic Signature, and 21 CFR Part 11 Compliance Support) |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | HI-7 |
| Construction | Stainless steel ferrule and ferrule-integrated end cap |
| Pipette Mounting Diameter | 1 mm |
| Cleaning Rod Length | 140 mm |
| Cleaning Rod Weight | 15 g |
| Adjustable Rotating Clamp | Yes |
| Included Accessories | Silicone rubber gasket (HI01PK01) |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IMS-30 |
| Drive Motor | 5-phase stepper motor |
| Stroke Range | 60 mm |
| Operating Voltage | AC 100–240 V, 50/60 Hz |
| Power Consumption | 15 W |
| Dimensions (Driver Unit) | 47.5 × 82.5 × 156.5 mm, 456 g |
| Dimensions (Control Unit) | 180 × 260 × 95 mm, 2.5 kg |
| Included Accessories | 1.5-m power cord, 1.5-m connection cable, dedicated mounting screws, two hex wrenches, spare fuses (installed in fuse holder) |
| Syringe Compatibility | Pre-programmed Hamilton syringe codes (e.g., 7001/7101 for 1 µL, 7002/7102 for 2 µL, 702/1702 for 25 µL, etc.), inner diameter range: 0.103–2.304 mm, volume range: 0.5–250 µL |
| Mounting Options | Direct screw-in or bracket-mounted integration with stereotactic micromanipulators |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | SYR Series |
| Construction | Glass or Stainless Steel |
| Syringe Capacity Options | 800 µL (SYR-15), 1060 µL (SYR-11) |
| Compatibility | IM-9A, IM-9B, IM-6, and other NARISHIGE micromanipulator-integrated microinjectors |
| Tip Configuration | Luer Lock or Resin-Tipped |
| Piston Seal | Viton or Fluoroelastomer O-ring |
| Surface Finish | Precision-polished borosilicate glass or electropolished stainless steel |
| Operating Principle | Positive-displacement hydraulic actuation via external pressure source (e.g., IM-9B pneumatic/hydraulic controller) |
| Brand | On-chip |
|---|---|
| Origin | Japan |
| Model | On-chip SPiS |
| Separation Method | Fully Automated |
| Maximum Sample Diameter | 200 µm |
| Dispensing Accuracy | >90% |
| Consumable | Disposable Tips |
| Imaging System | Integrated CCD Camera |
| Dilution Capability | On-board Automatic Dilution |
| Brand | Sartorius |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CellCelector Flex |
| Separation Method | Fully Automated Image-Guided Microaspiration |
| Brand | Sartorius |
|---|---|
| Origin | Shanghai, China |
| Model | CellCelector Flex |
| Separation Method | Fully Automated |
| Regulatory Compliance | GLP/GMP-Compliant Workflow Architecture |
| Imaging Modes | Brightfield, Phase Contrast, Fluorescence |
| Throughput | Up to 100+ single-cell picks per hour |
| Pick Accuracy | >95% for targeted subpopulations |
| Viability Post-Pick | ≥95% for monoclonal applications |
| Minimum Dispense Volume | ~1 nL |
| Compatible Vessels | Standard microplates (6–1536-well), Petri dishes, slides, filters, chips, PCR tubes, custom substrates |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | LCM |
| Separation Method | Automated |
| Dimensions | Compact design (32% smaller footprint vs. comparable LCM platforms) |
| Laser Configuration | Dual-solid-state laser system (IR capture + UV cutting) |
| Software | Arcturus LCM Software (5-step workflow, full instrument control, QC-integrated imaging, audit-ready metadata logging) |
| Brand | Yokogawa |
|---|---|
| Origin | Japan |
| Model | CQ3000 |
| Configuration | Desktop-integrated HCA platform with CSU-based confocal imaging, dual-camera option, sCMOS detector, integrated environmental chamber (7-day live-cell incubation), uniform illumination module, high-NA water-immersion objective, target-search automation, and 100 fps high-speed acquisition mode |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software | CellPathfinder (AI-assisted image analysis with deep learning modules) |
| Brand | Yokogawa |
|---|---|
| Origin | Japan |
| Model | CQ1 |
| Configuration | Benchtop, Motorized Stage with Environmental Chamber Option |
| Imaging Technology | Microlens-Enhanced Nipkow Disk Confocal |
| Max Acquisition Speed | 20 fps (optional) |
| Data Export Formats | FCS, CSV, ICE |
| Sample Compatibility | Standard Petri Dishes, Multiwell Plates (6–384-well), Tissue Slices, Spheroids, Colonies |
| Field of View | Wide-field tiling enabled |
| Light Source | Solid-state lasers (405/488/561/640 nm typical) |
| Detection | Back-illuminated EM-CCD or sCMOS camera (model-dependent) |
| Software Platform | CV8000-compatible analysis suite with open API |
| Brand | Yokogawa |
|---|---|
| Origin | Japan |
| Model | CV8000 |
| Type | Automated Confocal High-Content Imaging Platform |
| Application Domain | Phenotypic Screening, 3D Cell Culture Analysis, Live-Cell Kinetic Imaging |
| Regulatory Context | Designed for GLP-compliant workflows |
| Brand | YOKOGAWA |
|---|---|
| Origin | Japan |
| Manufacturer | YOKOGAWA Electric Corporation |
| Product Category | Imported Instrument |
| Model | Single Cellome™ Unit SU10 |
| Price Range | USD 125,000 – 194,000 (FOB Yokohama) |