PCR/Sequencing/Nucleic Acid Analysis
Filter
Showing 1–30 of 178 results
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3130xl |
| Instrument Type | First-Generation Sanger Sequencer |
| Category | Capillary Electrophoresis–Based DNA Sequencing System |
| Regulatory Designation | Import-Class Life Science Instrument |
| Vendor Status | Authorized Refurbishment & Distribution Partner |
| Brand | ACV |
|---|---|
| Model | BloFlu 96/96Pro |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well and 384-well formats |
| Heating Rate | 5°C/s |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.3°C |
| Excitation/Detection Technology | Fixed-Optics Light-Path System (Patented “Light-Shuttle” Architecture) |
| Calibration | Factory-Pre-Calibrated for All Fluorescence Channels |
| Control Interface | Integrated Touchscreen with Real-Time Signal Monitoring |
| Data Handling | Automated Data Transfer and On-Device Analysis |
| Thermal Gradient Function | Programmable Linear Gradient Across Block (Spanning up to 30°C) |
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | MoleDete C |
| Instrument Type | Gradient Thermal Cycler |
| Sample Throughput | Interchangeable reaction modules including 96×0.2 mL gradient single-block, 96×0.2 mL / 48×0.5 mL gradient deep-well block, dual 48×0.2 mL gradient block, 384-well single-block gradient module, and qPCR gradient module |
| Max Heating/Cooling Rate | 5 °C/sec (with optional rapid module) |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C (within 10 sec at 90 °C) |
| Brand | AGDIA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RF1604 |
| Sample Throughput | 8 samples per run |
| Heating Rate | 1°C per 10 seconds |
| Temperature Accuracy | ±0.1°C |
| Well-to-Well Temperature Uniformity | ±0.1°C |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AriaMx PCR |
| Instrument Type | Real-Time Quantitative PCR System |
| Thermal Uniformity | ±0.4 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Range | 25.0–99.9 °C |
| Max Ramp Rate | 6 °C/sec |
| Reaction Volume | 10–30 µL |
| Well Format | 96-well |
| Optical Modules | Up to 6 interchangeable filter-based modules |
| Excitation Source | Dye-specific LEDs per module |
| Detection Source | 8-channel photodiode array per module |
| Fluorophores Supported | SYBR Green, EvaGreen, FAM, HEX, ROX, CY3, CY5, ATTO 425 |
| Multiplex Capacity | Up to 5 targets per well |
| Data Acquisition Time | <3 sec per cycle |
| Onboard Storage | 5 GB |
| Touchscreen Interface | Yes |
| Remote Monitoring | Yes |
| Software Included | ARIA Software with LIMS connectivity, melt curve analysis, and FDA 21 CFR Part 11–compliant audit trail options |
| Self-Installable Optics | Yes |
| Dimensions (W×D×H) | 50.0 × 46.0 × 42.0 cm (19.7 × 18.1 × 16.5 in) |
| Warranty | 1 year standard |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | Magnis NGS |
| Instrument Type | Integrated Library Construction and QC System |
| Library Construction Method | Hybridization-Based Target Enrichment (Capture-Based) |
| Weight | 95 kg |
| Power Consumption | 450 W (avg) / 900 W (max) |
| Dimensions (W × D × H) | 620 mm × 720 mm × 710 mm |
| Operating Temperature | 15–25 °C |
| Relative Humidity | 30–70 % RH |
| Voltage | 100–240 VAC |
| Frequency | 50–60 Hz |
| Brand | Ahram |
|---|---|
| Origin | South Korea |
| Model | S1 / S1e |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 24-well |
| Heating Mechanism | Tri-zone semiconductor thermal blocks with micro-tube angular oscillation |
| Cycle Time | ≤10 min for 30 cycles |
| Power Options | Rechargeable Li-ion battery (≥4 h continuous operation) or AC adapter |
| Dimensions (W×D×H) | 19.5 × 17.7 × 17.9 cm |
| Weight | 3.0 kg (3.8 kg with battery) |
| Detection Channels | 3 / 5 / 6 multiplex fluorescent channels |
| Connectivity | LAN, Wi-Fi, Bluetooth, USB, optional GPS |
| Control Interface | Integrated capacitive touchscreen OS |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | ALLSHENG |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-NGS 180S |
| Sample Throughput | 8–24 samples per run (full automation) |
| Pipetting Channels | 24-channel adjustable (1/8/16/24-channel modes) |
| Pipetting Range | 0.5–200 µL |
| Accuracy (A) | ±10% at 0.5 µL, ±2% at 20 µL, ±1% at 100/200 µL |
| Precision (CV) | ≤5% at 0.5 µL, ≤2% at 20 µL, ≤1% at 100/200 µL |
| Minimum Sample Volume for Fluorometric Quantification | 2 µL |
| dsDNA Detection Limit | 0.4 ng |
| Fluorescence Module | 24-well integrated fluorometer, CV ≤1.5% repeatability |
| Thermal Modules | Dual 4–105 °C refrigeration units (±0.5 °C accuracy/uniformity), one heating module (RT–105 °C), one heating-shaking module (RT–105 °C, 200–3000 RPM, 2 mm orbit), one PCR thermal cycler (block: 4–99 °C, lid: 30–120 °C, uniformity ±0.7 °C, accuracy ≤±0.3 °C) |
| Magnetic Bead Purification | 96-well circular magnetic stand (compatible with PCR/deep-well plates) |
| Tip Capacity | Up to 10 tip boxes (6 single-layer + 2 double-layer positions) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Auto-NGS 200 NGS Library Preparation Workstation |
| Quotation | Available Upon Request |
| Dimensions (W×D×H) | 740 mm × 640 mm × 640 mm |
| Weight | 85 kg |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Sample Throughput | 1–96 samples per run |
| Plate Positions | 26 standard SBS-compliant positions |
| Pipetting System | 24-channel, 1–200 µL (capable of single-channel operation with pressure-capacitive liquid level detection) |
| Minimum Detectable Volume | 20 µL |
| Pipetting Accuracy | ≤±8% at 1 µL |
| Pipetting Precision | ≤±6% at 1 µL |
| Inter-well CV for Purification | ≤5% |
| Lysis/Binding Block Temperature Range | 10–110 °C (active rapid cooling) |
| Elution Block Temperature Range | 37–120 °C |
| Heating Rate (Lysis Block) | 25–110 °C in ≤5 min (from 25 °C ambient) |
| Cooling Rate (Lysis Block) | 110–25 °C in ≤7 min (from 25 °C ambient) |
| Temperature Uniformity | ±1 °C at 95 °C (lysis block) |
| Temperature Accuracy | ±1 °C at 95 °C (lysis block) |
| Integrated Fluorometer | 24-well, real-time concentration quantification |
| Integrated Thermal Module | PCR amplification and hybridization-compatible heating/mixing |
| Mixing Module | Au-Shaker — thermostatic vortex mixer with auto-clamping, 24 V DC, 120 W |
| Cooling Module | Au-Cooler — Peltier-based metal bath, 24 V DC, 160 W, CAN-enabled |
| Onboard Software | Android OS, 10-inch capacitive touchscreen, role-based user accounts, audit-trail-ready protocol editing, USB/LAN connectivity |
| Optional Vision System | For consumables recognition and position validation |
| Contamination Control | Built-in HEPA filtration + UV sterilization |
| Compatible Consumables | SBS-format plates, 8-tube strips, 96-well PCR plates (non-skirted), 60 mL reagent reservoirs, magnetic stands, tip boxes (<700 tips) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 10BS |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput | 1–10 samples/batch |
| Sample Volume Range | 50–5000 µL |
| Processing Time per Batch | 15–30 min |
| Heating Block Temperature Range | Room Temp +5°C to 105°C |
| Lysis/Elution Temperature Range | Room Temp to 120°C |
| Magnetic Bead Recovery Rate | >95% |
| Inter-Well CV | <5% |
| Detection Sensitivity | ≥100 copies |
| Display | 4.3″ Color Touchscreen |
| Internal Storage | SD Card |
| Connectivity | USB, Ethernet, Wi-Fi |
| Power Input | Max 350 W |
| Dimensions (W×D×H) | 340 × 350 × 410 mm |
| Weight | 18.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 48 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–48 |
| Sample Volume Range | 200–3000 µL |
| Processing Time per Batch | 15 min |
| Heating Positions | 2 of 8 plate stations |
| Lysis & Elution Temperature Range | Ambient to 120 °C |
| Inter-Well CV | <5% |
| Detection Sensitivity | >95% positive detection rate for 100-copy samples |
| Display | 7-inch color touchscreen |
| Internal Storage | SD card |
| Power Input | ≤300 W |
| Dimensions (W×D×H) | 560 × 620 × 500 mm |
| Weight | 54 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 96 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–96 (also supports 1–24 configuration) |
| Sample Volume Range | 50–1000 µL and 50–10000 µL |
| Processing Time per Batch | 30–60 minutes |
| Heating Capability | 2 of 8 plate positions with precision temperature control (RT to 120 °C) |
| Display | 7-inch color touchscreen interface |
| Onboard Data Storage | Internal SD card |
| Connectivity | USB, Ethernet, optional Wi-Fi |
| UV Sterilization | Integrated |
| Cross-Contamination Control | Anti-drip baffle, disposable consumables, automated magnetic rod sleeve loading/unloading, barcode recognition |
| Reproducibility | CV < 5% across wells |
| Sensitivity | >95% positive detection rate for samples containing ≥100 copies |
| Power Input | ≤300 W |
| Dimensions (W×D×H) | 560 × 620 × 500 mm |
| Weight | 54 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure Mini |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–16 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | ~15 minutes |
| Principle | Magnetic Rod-Based Bead Separation with Vertical Mixing |
| Inter-Well CV | ≤3% |
| Magnetic Bead Recovery Rate | >95% |
| Temperature Control Range | Ambient +5°C to 120°C (Lysis & Elution) |
| Mixing Modes | Programmable Vortex, Aspiration/Dispense, Vertical Oscillation |
| Display | 4.3-inch Touchscreen + 3 Physical Shortcut Keys + Optional External Mouse |
| Onboard Program Storage | 100 protocols |
| Connectivity | USB, Ethernet, Wi-Fi |
| Dimensions (W×D×H) | 20 × 26 × 30 cm |
| Weight | 7 kg |
| Power Input | DC 24 V / 5 A (Battery-Compatible) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Auto-Pure S32 |
| Pricing | Upon Request |
| Principle | Magnetic Bead-Based Separation |
| Sample Throughput | 1–32 samples per run |
| Compatible Plate Format | 96-Deep-Well Plate |
| Processing Volume | 30–1000 µL |
| Inter-Well CV | ≤5% |
| Lysis Temperature Range | Ambient to 120°C |
| Elution Temperature Range | Ambient to 120°C |
| Heating Time (RT to 120°C) | ≤4 min |
| Cooling Time (100°C to 40°C) | ≤10 min (at 25°C ambient) |
| Temperature Accuracy | ±0.5°C |
| Temperature Uniformity | ±1°C at 100°C |
| Mixing Intensity | 10 Adjustable Levels |
| Display | 7-inch Color Touchscreen |
| Onboard Program Storage | Up to 500 Protocols |
| Interface Ports | 2× USB-A, 1× USB-B, 1× Ethernet |
| Wireless Connectivity | Built-in Wi-Fi (4G optional) |
| Barcode Scanning | External Scanner Support with Auto-Protocol/ID Recognition |
| UV Sterilization | Integrated Germicidal UV Lamp |
| Air Filtration | HEPA-Grade Aerosol Filtration System |
| Power Supply | AC 110–240 V, 50/60 Hz, 450 VA |
| Dimensions (W×D×H) | 417 × 410 × 426 mm |
| Weight | 20 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure20 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–20 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | 15–45 minutes |
| Magnetic Rod Count | 20 |
| Magnetic Bead Recovery Rate | >95% |
| Inter-Well CV | <3% |
| Lysis & Elution Temperature Range | Ambient to 90 °C |
| Touchscreen Interface | 7-inch high-resolution color LCD |
| Preloaded Protocols | >100 (15 factory-default) |
| UV Sterilization | Integrated |
| Connectivity | 4× USB-A, 1× USB-B, Ethernet, Wi-Fi, SD card slot |
| Power Supply | AC 110–220 V, 50/60 Hz |
| Dimensions | 440 × 467 × 453 mm |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure32 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput | 1–32 samples per run |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Run | 15–40 min |
| Magnetic Rod Count | 32 |
| Magnetic Bead Recovery Rate | >95% |
| Inter-Well CV | <3% |
| Lysis & Elution Temperature Range | Ambient to 90 °C |
| Touchscreen Interface | 7-inch high-resolution color LCD |
| Preloaded Protocols | ≥100 (15 factory-default) |
| UV Sterilization | Integrated |
| Connectivity | 4× USB-A, 1× USB-B, Ethernet, Wi-Fi, SD card slot |
| Power Supply | AC 110–220 V, 50/60 Hz |
| Dimensions | 440 × 467 × 453 mm |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Ecos-Gene Automated Nucleic Acid Detection and Analysis System |
| Sample Throughput | 1/2/4 samples per unit (scalable to 16) |
| Fluorescence Channels | 4 (470–510 nm, 530–565 nm, 585–620 nm, 630–665 nm) |
| Thermal Block Temperature Range | Ambient to 120 °C |
| Temperature Accuracy | ±0.2 °C |
| PCR Ramp Rates | ≥6 °C/s (avg. heating), ≥8 °C/s (max. heating), ≥4.5 °C/s (avg. cooling), ≥8 °C/s (max. cooling) |
| Extraction CV | ≤5% |
| Sample Input Volume | Up to 3 mL (working volume ~2.5 mL) |
| Software Platform | Windows-based, LIS- and cloud-database–compatible |
| Compliance | Designed for CLIA-waived and IVD-use environments |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Emos-Gene 600 / Emos-Gene 600A |
| Sample Capacity | 3 × 32-well (0.2 mL for 600 |
| Detection Channels | 6 independent optical channels (C1–C6) |
| Excitation Source | High-power white LED array |
| Detection Sensor | High-sensitivity CMOS imaging system with precision filter wheel |
| Temperature Range | 4 °C to 99.9 °C |
| Temperature Uniformity | ±0.2 °C @ 95 °C |
| Temperature Accuracy | ±0.15 °C |
| Ramp Rate | 4 °C/s (both heating and cooling) |
| Thermal Lid | Auto-adjustable pressure, 30–110 °C |
| Gradient Capability | Single-module gradient control |
| Display | 13.3-inch capacitive touchscreen |
| OS | Windows 10 or later |
| Power Input | 100–240 V~, 50 Hz, 1400 VA |
| Dimensions (D×W×H) | 504 × 360 × 410 mm |
| Weight | 35 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Esan-Gene 696 / Esan-Gene 696A |
| Sample Format | 696 — 0.2 mL tubes & 96-well plates |
| Reaction Volume | 10–100 µL |
| Optical Channels | 6 (F1: FAM/SYBR Green I |
| F2 | HEX/JOE/VIC |
| F3 | ROX/Texas Red |
| F4 | Cy5/Quasar-670 |
| F5 | Cy5.5 |
| F6 | user-definable, default FRET) |
| Dynamic Range | 10⁰–10¹⁰ copies/µL |
| LOD | 1 copy |
| Ct Reproducibility | CV ≤ 1% |
| Temperature Range | 4–99.9 °C |
| Heating Rate | 3.5 °C/s (avg) |
| Cooling Rate | 2.5 °C/s (avg) |
| Block Uniformity | ±0.2 °C @ 95 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Precision | 0.1 °C |
| Melting Resolution | 0.1 °C |
| Gradient Range | 1–40 °C across 6 zones |
| Heat Lid Temp | 30–110 °C |
| Display | 10.1″ LVDS capacitive touchscreen |
| Interfaces | USB-A ×3, LAN ×1 |
| Data Export | Excel, PDF |
| Compliance | Designed for GLP-compliant workflows |
| Brand | AMTK |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automated Platform |
| Throughput | 96 or 192 samples per run |
| Sample Volume Range | 10–200 µL |
| Processing Time per Run | 15–30 minutes |
| Dimensions (L×W×H) | 110 × 75 × 88 cm |
| Weight | ~200 kg |
| Deck Capacity | 25 plate positions |
| Power Supply | AC 220 V, 50 Hz, 650 W |
| Pipetting Range | 2–200 µL |
| Compatible Tips | 250 µL standard or filter tips |
| Pipetting Precision | ≤4% CV at 10 µL |
| Pipetting Accuracy | ±8% at 10 µL |
| Regulatory Status | Class I Medical Device Filing (Su Su Yi Xie Bei 20181026) |
| Brand | AMTK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LH-1209 |
| Price Range | USD 70,000–140,000 |
| Instrument Type | Magnetic Bead-Based Extraction System |
| Automation Level | Dedicated Fully Automated Platform |
| Throughput | 96 or 192 samples per run |
| Sample Volume Range | 0.5–200 µL |
| Processing Time per Batch | ~40 minutes |
| Elution Volume | Adjustable (typically 30–100 µL) |
| Plate Capacity | 25 deck positions |
| Operating Temperature | 23 °C ± 5 °C |
| Power Supply | 220 V AC, 50 Hz |
| Relative Humidity | 10–90% RH (non-condensing) |
| Yield | 4–8 µg genomic DNA from 100–200 µL fresh whole blood |
| Brand | AMTK |
|---|---|
| Origin | Jiangsu, China |
| Model | LH-1406 |
| Instrument Type | Integrated NGS Library Construction and Quality Control Workstation |
| Library Construction Method | Hybridization Capture-Based |
| Supported Plate Format | 96-well SBS-standard plates |
| Liquid Handling Range | 0.5 µL – 1 mL |
| Pipetting Precision | CV < 5% at 2 µL |
| Positioning Accuracy | ±0.1 mm (XYZ) |
| Onboard Deck Capacity | 12 standardized deck positions |
| Thermal Modules | Integrated PCR Module (VCM® technology), Heating-Shaking Module, Triple-Zone Temperature-Controlled Enclosure (6–110 °C, including ambient and refrigerated zones) |
| Software | Graphical workflow editor with breakpoint resumption, open scripting interface, and audit-trail-ready operation log |
| Brand | AMTK |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | LH 1209 |
| Price Range | USD $68,000–$109,000 (FOB) |
| Instrument Type | NGS Library Construction System |
| Library Construction Method | Hybridization Capture-Based |
| Supported Plate Formats | ANSI/SLAS-compliant 96-well, 384-well, and 1536-well microplates |
| Pipetting Range | 0.1–250 µL |
| Precision | CV <10% at 0.1–2 µL |
| Accuracy | ±2% at 1 µL and 10 µL |
| Resolution | 0.1 µL |
| Dimensions (W×D×H) | 1100 × 720 × 800 mm |
| Weight | 110 kg |
| Power Supply | 220 V, 50 Hz |
| Operating Temperature | 5–40 °C |
| Safety Features | Emergency Stop Button, UV-Compatible Enclosure Option, Integrated Alcohol-Wipe-Compatible Surfaces |
| Modular Accessories | Heater, Shaker, Magnetic Stand, Barcode Scanner, Vacuum Filtration Module, Wash Station |
| Consumable Compatibility | ANSI/SLAS-standard plates, reservoirs, tube racks, and low-cost domestic disposable tips (with optional aerosol-resistant filter tips) |
| Brand | AMTK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LH1406 |
| Instrument Type | Magnetic Bead-Based Purification System |
| Automation Level | Dedicated Fully Automated Platform |
| Throughput | 1–96 samples per run |
| Sample Volume Range | 0.5–200 µL |
| Processing Time per Batch | ~40 minutes |
| Elution Volume | Adjustable (typically 30–100 µL) |
| Ambient Operating Temperature | 23 °C ± 5 °C |
| Power Supply | 110/220 VAC, 50/60 Hz |
| Relative Humidity | 10–90% RH (non-condensing) |
| Deck Capacity | 12 deck positions |
| Extracted Yield (Human Whole Blood, 100–300 µL) | 4–8 µg total nucleic acid |
| Brand | AMTK |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | ME-32 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automated Platform |
| Throughput | 32 samples per run |
| Sample Volume Range | 20–1200 µL |
| Processing Time per Run | 15–30 minutes |
| Maximum Magnetic Bead Recovery Rate | >95% |
| Compatible Plate Format | 96-well deep-well plates |
| Heating Module Option | Ambient to +100 °C |
| Mixing Agitation | Multi-level programmable vortexing |
| Reagent Compatibility | Open-platform magnetic bead kits (third-party compatible) |
| Onboard UV Sterilization | Yes |
| Safety Interlock | Motorized lid sensor with automatic pause/resume |
| User Interface | 7-inch capacitive touchscreen, bilingual (English/Chinese) |
| Stored Protocols | >100 user-editable methods |
| Protocol Editor | Full graphical programming interface with stepwise parameter control (lysis temp, wash cycles, elution volume, mixing speed/duration, hold times) |
| Brand | AMTK |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ME-480 |
| Price Range | USD 140,000–280,000 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Batch Capacity | 480 samples per run |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | 15–30 minutes |
| Throughput Configuration | 96-channel magnetic rod array (5×96 = 480) |
| Temperature Control | 10 independent heating zones, 20–100 °C |
| Magnetic Field Strength | ≥5200 Gauss |
| Magnetic Bead Recovery Rate | ≥98% |
| Inter-Sample CV | <5% |
| Power Supply | AC 220 V, 50 Hz, 900 VA |
| Dimensions (W×D×H) | 1130 × 770 × 1160 mm |
| Weight | 175 kg |
| Aerosol Containment | Integrated HEPA H14 filter (≥99.99% efficiency for 0.3 µm particles), UV-C sterilization (100 µW/cm²), anti-drip baffles |
| Brand | AMTK |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-LN96 |
| Instrument Category | NGS Library Construction System |
| Library Construction Type | Automated NGS Library Prep Platform |
| Liquid Handling Range | 0.5–1000 µL |
| Channel Configurations | 1/4/8/16/32-channel pipetting heads |
| Pipetting Precision | CV ≤5% at 1 µL |
| Integrated Modules | Barcode Scanner + Ultrasonic Liquid Level Detection, Heating & Vortexing Module, Magnetic Separation Module, Hematocrit Disc Module, Three-Zone Temperature-Controlled Enclosure (6–110 °C), Air-Driven Positive Displacement Pipetting System |
| Software | Embedded modular control with breakpoint resume, SBS-compliant and non-SBS layout support, liquid class calibration, real-time liquid level feedback loop |
| Compliance Ready | Designed for GLP/GMP-aligned workflows |
| Brand | Analytik Jena / biometra |
|---|---|
| Origin | Germany |
| Model | qTOWER³ auto 84 |
| Instrument Type | Gradient Real-Time PCR System |
| Sample Capacity | 384-well |
| Heating Rate | 3.7 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Dimensions (W × D × H) | 310 × 365 × 479 mm |
| Block Material | Anodized Aluminum Alloy |
| Recommended Sample Volume | 2–30 µL |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Category | Imported Instrument |
| Model | Biometra TAdvanced 384G |
| Throughput | 384-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Fast PCR Cycler |
| Sample Capacity | 96-well (0.2 mL tubes, 96-well plates, or 12×8 strip tubes) |
| Max Heating Rate | 6.0 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.2 °C |
| Gradient Span | 0.1–30.0 °C (linear, per column) |
| Gradient Range | 20–99 °C |
| Block Temp Range | 3–99 °C |
| Lid Temp Range | 30–110 °C |
| Display | 7″ capacitive color touchscreen |
| Noise Level | ≤45 dB(A) |
| Power Consumption | 850 W |
| Dimensions (W×H×D) | 277 × 264 × 457 mm |
| Weight | 15 kg |