| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | Magnis NGS |
| Instrument Type | Integrated Library Construction and QC System |
| Library Construction Method | Hybridization-Based Target Enrichment (Capture-Based) |
| Weight | 95 kg |
| Power Consumption | 450 W (avg) / 900 W (max) |
| Dimensions (W × D × H) | 620 mm × 720 mm × 710 mm |
| Operating Temperature | 15–25 °C |
| Relative Humidity | 30–70 % RH |
| Voltage | 100–240 VAC |
| Frequency | 50–60 Hz |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Auto-NGS 200 NGS Library Preparation Workstation |
| Quotation | Available Upon Request |
| Dimensions (W×D×H) | 740 mm × 640 mm × 640 mm |
| Weight | 85 kg |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Sample Throughput | 1–96 samples per run |
| Plate Positions | 26 standard SBS-compliant positions |
| Pipetting System | 24-channel, 1–200 µL (capable of single-channel operation with pressure-capacitive liquid level detection) |
| Minimum Detectable Volume | 20 µL |
| Pipetting Accuracy | ≤±8% at 1 µL |
| Pipetting Precision | ≤±6% at 1 µL |
| Inter-well CV for Purification | ≤5% |
| Lysis/Binding Block Temperature Range | 10–110 °C (active rapid cooling) |
| Elution Block Temperature Range | 37–120 °C |
| Heating Rate (Lysis Block) | 25–110 °C in ≤5 min (from 25 °C ambient) |
| Cooling Rate (Lysis Block) | 110–25 °C in ≤7 min (from 25 °C ambient) |
| Temperature Uniformity | ±1 °C at 95 °C (lysis block) |
| Temperature Accuracy | ±1 °C at 95 °C (lysis block) |
| Integrated Fluorometer | 24-well, real-time concentration quantification |
| Integrated Thermal Module | PCR amplification and hybridization-compatible heating/mixing |
| Mixing Module | Au-Shaker — thermostatic vortex mixer with auto-clamping, 24 V DC, 120 W |
| Cooling Module | Au-Cooler — Peltier-based metal bath, 24 V DC, 160 W, CAN-enabled |
| Onboard Software | Android OS, 10-inch capacitive touchscreen, role-based user accounts, audit-trail-ready protocol editing, USB/LAN connectivity |
| Optional Vision System | For consumables recognition and position validation |
| Contamination Control | Built-in HEPA filtration + UV sterilization |
| Compatible Consumables | SBS-format plates, 8-tube strips, 96-well PCR plates (non-skirted), 60 mL reagent reservoirs, magnetic stands, tip boxes (<700 tips) |
| Brand | AMTK |
|---|---|
| Origin | Jiangsu, China |
| Model | LH-1406 |
| Instrument Type | Integrated NGS Library Construction and Quality Control Workstation |
| Library Construction Method | Hybridization Capture-Based |
| Supported Plate Format | 96-well SBS-standard plates |
| Liquid Handling Range | 0.5 µL – 1 mL |
| Pipetting Precision | CV < 5% at 2 µL |
| Positioning Accuracy | ±0.1 mm (XYZ) |
| Onboard Deck Capacity | 12 standardized deck positions |
| Thermal Modules | Integrated PCR Module (VCM® technology), Heating-Shaking Module, Triple-Zone Temperature-Controlled Enclosure (6–110 °C, including ambient and refrigerated zones) |
| Software | Graphical workflow editor with breakpoint resumption, open scripting interface, and audit-trail-ready operation log |
| Brand | AMTK |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | LH 1209 |
| Price Range | USD $68,000–$109,000 (FOB) |
| Instrument Type | NGS Library Construction System |
| Library Construction Method | Hybridization Capture-Based |
| Supported Plate Formats | ANSI/SLAS-compliant 96-well, 384-well, and 1536-well microplates |
| Pipetting Range | 0.1–250 µL |
| Precision | CV <10% at 0.1–2 µL |
| Accuracy | ±2% at 1 µL and 10 µL |
| Resolution | 0.1 µL |
| Dimensions (W×D×H) | 1100 × 720 × 800 mm |
| Weight | 110 kg |
| Power Supply | 220 V, 50 Hz |
| Operating Temperature | 5–40 °C |
| Safety Features | Emergency Stop Button, UV-Compatible Enclosure Option, Integrated Alcohol-Wipe-Compatible Surfaces |
| Modular Accessories | Heater, Shaker, Magnetic Stand, Barcode Scanner, Vacuum Filtration Module, Wash Station |
| Consumable Compatibility | ANSI/SLAS-standard plates, reservoirs, tube racks, and low-cost domestic disposable tips (with optional aerosol-resistant filter tips) |
| Brand | AMTK |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-LN96 |
| Instrument Category | NGS Library Construction System |
| Library Construction Type | Automated NGS Library Prep Platform |
| Liquid Handling Range | 0.5–1000 µL |
| Channel Configurations | 1/4/8/16/32-channel pipetting heads |
| Pipetting Precision | CV ≤5% at 1 µL |
| Integrated Modules | Barcode Scanner + Ultrasonic Liquid Level Detection, Heating & Vortexing Module, Magnetic Separation Module, Hematocrit Disc Module, Three-Zone Temperature-Controlled Enclosure (6–110 °C), Air-Driven Positive Displacement Pipetting System |
| Software | Embedded modular control with breakpoint resume, SBS-compliant and non-SBS layout support, liquid class calibration, real-time liquid level feedback loop |
| Compliance Ready | Designed for GLP/GMP-aligned workflows |
| Brand | LIVOBOT |
|---|---|
| Origin | Beijing, China |
| Manufacturer | LIVOBOT |
| Type | Domestic |
| Model | EosBot Seq24 |
| Instrument Category | Integrated Library Prep & QC System |
| Library Prep Type | NGS Library Preparation System |
| Supported Plate Format | 96-well |
| Overall Function | Fully Automated Library Construction + On-instrument Quantification & QC |
| Dimensions (W × D × H) | 1200 mm × 850 mm × 1050 mm |
| Weight | 300 kg |
| Brand | Inheco |
|---|---|
| Origin | Germany |
| Model | CPAC Ultraflat, CPAC Microplate |
| Temperature Range (1-TEC) | 4 °C to 70 °C |
| Temperature Range (2-TEC) | 4 °C to 110 °C |
| Plate Compatibility | 96-well, 384-well microplates |
| Mounting Options | Surface-mounted (Ultraflat), Embedded (Microplate) |
| Height (Ultraflat) | 80 mm |
| Height (Microplate active surface) | ~14 mm above deck |
| System Integration | Compatible with Agilent Bravo/BioCel, Beckman Biomek FX/NX/i-Series, Hamilton STAR/Nimbus/Vantage, PerkinElmer Sciclone/Zephyr/JANUS/Multiprobe II, Protodyne BioCube, Tecan Freedom EVO/Genesis/TEMO/Fluent |
| Control Interface | STC (Single TEC Control), MTC or MTC Compact (Multi-Module Control, up to 6 units) |
| Power Supply | 24 V DC |
| Weight | 10 kg |
| Dimensions (W×D×H) | 300 mm × 600 mm × 900 mm |
| Application | Integrated thermal control for NGS library preparation — amplicon-based workflows, enzymatic reactions, adapter ligation, cleanup incubations, and QC-compatible temperature staging |
| Brand | MGI |
|---|---|
| Origin | Shenzhen, China |
| Model | DNBelab C-TaiM 4 |
| Instrument Type | Library Construction System |
| Library Type | Single-Cell Library Preparation System |
| Throughput | Independent 4-Channel Configuration |
| Sample Format | Microfluidic Cartridge-Based |
| Core Function | Fully Automated Single-Cell Nucleic Acid Library Construction |
| Regulatory Classification | Research-Use-Only (RUO) Instrument |
| Compliance | Designed for ISO 13485-aligned manufacturing environment |
| Software Validation | Supports audit trail and user access control per FDA 21 CFR Part 11 requirements |
| Brand | Raykol |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Vitae 180 NGS |
| Instrument Type | NGS Library Construction System |
| Library Construction Method | Hybridization-Based Target Enrichment (Capture) |
| Supported Plate Format | SBS-compliant 384-well plates |
| Throughput | 1–32 samples per run |
| Dimensions (W×D×H) | 1200 mm × 750 mm × 1085 mm |
| Weight | 120 kg |
| Integrated Thermal Cycler | Yes (desktop, with sealing and heated lid) |
| Onboard Modules | PCR heating block, PCR cooling block, reagent cold storage (4 °C), magnetic plate holder, plate vortexer, UV sterilization lamp (optional), HEPA filtration (positive/negative pressure, optional) |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Model | Vitae120 NGS-SA |
| Instrument Type | NGS Library Construction System |
| Library Construction Method | Hybridization Capture-Based |
| Supported Plate Formats | 8-well, 32-well, and 96-well PCR plates |
| Overall Function | Fully Automated NGS Library Preparation |
| Dimensions (W×D×H) | 960 × 750 × 1100 mm |
| Weight | 120 kg |
| Integrated Microfluidic Chip | None |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | BioQulerm |
| Pricing | Upon Request |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | JANUS G3 |
| Instrument Type | NGS Library Preparation System |
| Library Prep Format | Automated, Integrated NGS Library Construction Platform |
| Configuration | Modular, User-Configurable Deck Layout |
| Software Platform | MethodBuilder™ and Interchange™ Integration Ready |
| Regulatory Support | FDA 21 CFR Part 11–compliant audit trail options available |
| Service Model | Application-Onboarding Enabled with Global Field Applications Scientists |
| Brand | SINGER |
|---|---|
| Origin | United Kingdom |
| Model | PIXL |
| Dimensions (L×W×H) | 718 × 630 × 810 mm |
| Weight | 70 kg |
| Power Supply | 240 V, 10 A (2400 W) |
| Throughput | Up to 130 microplates per hour |
| Supported Plate Formats | 96-well, 384-well, 1536-well SBS-compliant plates, Petri dishes, shallow/deep well plates, agar plates |
| Picking Modes | Liquid-to-liquid, liquid-to-agar, agar-to-liquid |
| Sterilization | Integrated UV lamp + anti-contamination front shield |
| Imaging | High-resolution static/dynamic colony morphology analysis |
| Fluorescence Capability | Multi-channel fluorescence module for GFP/RFP/mCherry and other standard fluorophores |
| Software Interface | Graphical user interface (GUI) with drag-and-drop workflow configuration |
| External Integration | API-enabled for LIMS, robotic arms, and third-party liquid handlers |