| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | APN-III |
| Price | USD 8,400 (approx.) |
| Function Type | Multi-analyte (simultaneous detection of multiple contaminants) |
| Sample Compatibility | Universal for liquid and homogenized food matrices |
| Wavelengths | 410 nm, 538 nm, 590 nm |
| Detection Time | ≤30 minutes per batch |
| Repeatability | ≤1% RSD |
| Detection Channels | 12-position automatic cuvette holder |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ≤±0.05 nm |
| Detector | Imported CCD sensor |
| Display | 10.1-inch high-resolution LCD |
| Interfaces | RS-232, USB 2.0, built-in thermal printer |
| Power Supply | 12 V DC (including automotive 12 V input) |
| Enclosure | Industrial-grade aluminum alloy portable case |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | SKJ-IA |
| Pricing | Upon Request |
| Function Type | Multi-analyte Quantitative Detection Platform |
| Sample Applicability | Universal for Grains, Feed, Fruits, Vegetables, Tea, Dairy Products |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | 15–30 minutes |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 independent optical channels |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SKJ-IA |
| Price Range | USD 7,000 – 14,000 |
| Function Type | Multi-analyte Quantitative Detection |
| Sample Versatility | Universal for Solid & Liquid Food Matrices |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | ≤25 min |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 simultaneous independent channels |
| Detection Range (Cd & Pb) | 0–1 ppm |
| Regulatory Alignment | Designed to support ISO 17025-compliant workflows and GLP-aligned food safety testing |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SKJ-IA-04 |
| Price Range | USD 7,000 – 14,000 |
| Functionality | Multi-analyte (Cd, Pb, Cu, Cr) |
| Sample Versatility | Universal for solid and liquid food matrices |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | ≤25 minutes |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 parallel optical channels |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SKJ-IA-05 |
| Function Type | Multi-analyte Quantitative Detection |
| Sample Versatility | Universal for Herbal Materials, Decoction Pieces, Animal-derived Herbs |
| Optical Wavelength | 410 nm |
| Detection Time per Sample | ≤25 minutes |
| Repeatability (RSD) | ≤0.2% |
| Detection Channels | 6-channel simultaneous measurement |
| Detection Range | Cd 0.1–5 mg/kg, Pb 0.2–10 mg/kg, Cu 2–50 mg/kg |
| Accuracy | Cd ≥80%, Pb ≥80%, Cu ≥75% |
| Compliance Reference | Chinese Pharmacopoeia (2020 Ed., Vol. IV, General Chapter 0412 & 2341) |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | SKJ-IA-III |
| Function Type | Multi-Analyte (Heavy Metals, Mycotoxins, Pesticides) |
| Sample Compatibility | Universal (Grains, Feed, Fruits, Vegetables, Dairy, Tea) |
| Optical Detection Wavelength | 410 nm |
| Assay Time per Sample | ≤18 minutes |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 parallel optical channels |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SKJ-IA/I |
| Pricing | Upon Request |
| Function Type | Multi-analyte Quantitative Detection |
| Sample Applicability | Universal for Cereals, Feed, Fruits, Vegetables, Tea, Dairy |
| Wavelength | 410 nm |
| Assay Time | 25 minutes per sample |
| Coefficient of Variation (CV) | ≤0.2% |
| Detection Channels | 6 independent optical channels |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Model | SKJ-IIA |
| Price | ¥80,000 |
| Function Type | Multi-analyte (200+ targets) |
| Sample Applicability | Universal for food, agricultural, aquatic, livestock, and feed samples |
| Wavelengths | 410 nm, 538 nm, 590 nm |
| Detection Time | <15 min per sample |
| Repeatability | ≤0.2% CV |
| Detection Architecture | 3 independent assay zones, 20-channel parallel optical readout |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SKJ-IIIA |
| Price | USD 11,200 (approx.) |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Universal for Solid, Liquid, and Semi-solid Food Matrices |
| Optical Wavelengths | 410 nm, 538 nm, 630 nm |
| Detection Time per Assay | ≤ 30 min |
| Photometric Repeatability (CV) | ≤ 1% |
| Detection Channels | 10 independent optical channels |
| Brand | BioControl |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Assurance GDS |
| Pricing | Available Upon Request |
| Brand | Charm |
|---|---|
| Origin | USA |
| Model | CHARM II 7600 |
| Function Type | Multi-analyte Screening Platform |
| Sample Applicability | Universal for Food & Agricultural Commodities |
| Wavelength Range | 300–680 nm |
| Assay Time | ≤10 min per test |
| Repeatability | ≤0.5% CV |
| Detection Channels | Dual-channel optical reader |
| Regulatory Recognition | FDA-accepted, EU-validated, HKFDA & MFDS (Korea) endorsed, GB/T-standardized in China |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROSA M-Reader |
| Price Range | USD 1,400 – 25,000 (FOB) |
| Function Type | Multi-analyte Quantitative Immunoassay Platform |
| Sample Versatility | Cereals, Feed, Nuts, Corn, Wheat, Barley, Soybean Meal, Ground Spices |
| Wavelength Range | Not Applicable (Reflectance-based Optical Detection) |
| Assay Time | ≤5 min per test |
| Repeatability | CV <15% (within-run) |
| Detection Channels | 4 independent optical channels |
| Brand | CSY Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CSY-10CDF |
| Function Type | Multi-analyte (10-channel) Spectrophotometric Analyzer |
| Sample Compatibility | Liquid extracts from tea leaves, tea beverages, instant tea powders, and herbal infusions |
| Wavelength | 410 nm ± 2 nm |
| Measurement Time per Sample | ≤ 3 min |
| Photometric Repeatability | ±1% (Transmittance) |
| Optical Path | 10 mm cuvette |
| Absorbance Range | 0.000–4.000 ABS |
| Wavelength Accuracy | < ±2.0 nm |
| Baseline Stability | ±0.001 A/hr |
| Data Storage Capacity | ≥ 8,000 records |
| Display | 7-inch color TFT LCD touchscreen |
| Connectivity | RS-232, USB, Wi-Fi, Ethernet |
| Power Supply | AC 100–240 V, 50/60 Hz or optional DC 12 V battery operation |
| Dimensions | 350 × 290 × 130 mm |
| Weight | 3.8 kg |
| Brand | CSY (Shenzhen Finysis Instrument Manufacturing Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Production | Yes |
| Model | CSY-N24A |
| Function Type | Multi-analyte Rapid Detection System |
| Sample Compatibility | Broad-spectrum for fruits, vegetables, herbs, and fresh produce |
| Wavelength | 412 nm ± 2 nm |
| Optical Path | 10 mm standard cuvette |
| Absorbance Range | 0.000–4.000 ABS |
| Photometric Repeatability | ≤0.1% |
| Photometric Accuracy | ±1% transmittance |
| Inter-channel Variation | ≤0.2% |
| Stability | ±0.001 A/hr |
| Measurement Time per Sample | ≤3 minutes |
| Data Storage Capacity | >800,000 records |
| Display | 10.1″ capacitive touchscreen (1920×1200), Android OS |
| Connectivity | USB, RS-232, Wi-Fi, Bluetooth, MicroSD slot |
| Integrated Thermal Printer | Compliance certificate + QR/barcode hybrid printing |
| Cloud Integration | Compatible with national agricultural traceability platforms (e.g., China National Traceability Platform) |
| Regulatory Alignment | Designed to support GB/T 22292–2017 (Pesticide Residue Testing in Vegetables and Fruits), NY/T 448–2021 (Rapid Detection of Organophosphorus and Carbamate Pesticides), and GLP-aligned data audit trails |
| Brand | Fitlylab |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FITLY-9616 |
| Function Type | Multi-analyte (Simultaneous Detection of 30+ Food Contaminants & Additives) |
| Sample Compatibility | Liquid, Solid, Semi-solid Extracts (Homogenized or Centrifuged) |
| Wavelength Range | 410–900 nm (Fixed LED Sources at 410, 536, 595, 620 nm) |
| Detection Channels | 16-Channel Photometric Array |
| Photometric Repeatability | ≤ ±1% T |
| Immunoassay Detection Mode | Single-Channel CCD-Based Lateral Flow Reader (3-Megapixel, 2048×1536 Resolution, Reflective T/C Quantification) |
| T/C Accuracy | ≤ ±0.1 T/C |
| T/C Precision (CV) | ≤ 5% |
| Stability | ≤ 0.1 T/C over 10 min |
| Assay Time | <10 s per lateral flow strip |
| Data Export Format | Excel (.xlsx) |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2, 10/100 Mbps Ethernet |
| Onboard Storage | 32 GB SSD |
| RAM | 4 GB |
| CPU | Dual-core 1.6 GHz |
| Display | 10.2-inch Full-color Capacitive Touchscreen |
| Weight | ≤ 3.0 kg |
| Brand | Fitlylab |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RVLM |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Solid, Liquid, Surface, Paste, and Slurry Samples |
| Optical Detection | Triple-wavelength Simultaneous Photometric Analysis |
| Detection Channels | 8 Independent Wells |
| Detection Time | Inversely Proportional to Target Microbial Load (as low as <2 h for ≥10⁸ CFU/mL) |
| Repeatability | High (CV <15% under standardized conditions) |
| Regulatory Compliance | ISO 16140:2003 Validated Alternative Method |
| Brand | Jida Xiaotian’e |
|---|---|
| Model | GDYQ-100A2 |
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Detection Limit | 5.0 mg/kg |
| Measurement Range | 0.0–500.0 mg/kg |
| Accuracy | ±2% |
| Assay Time | ≤10 min per sample |
| Display | Backlit LCD with Chinese interface |
| Control System | Embedded MCU with data logging, parameter configuration, statistical analysis, and USB/RS232 connectivity |
| Sample Prep | Dedicated extraction kit and single-use reagent cartridges |
| Compliance | Designed per GB 5009.287–2023 (National Food Safety Standard – Determination of Formaldehyde Sulfoxylate in Foods) |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYQ-100M |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-Analyte (Simultaneous Detection of >30 Parameters) |
| Sample Compatibility | Universal for Solid, Semi-Solid, and Liquid Food Matrices |
| Wavelength Range | 400–630 nm |
| Assay Time | 3–20 minutes per test |
| Brand | Jilin University–Xiaotian’e |
|---|---|
| Model | GDYQ-107S |
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | PRC |
| Detection Limit | 25.0 mg/kg |
| Measurement Range | 0.0–2000.0 mg/kg |
| Accuracy | ±5% |
| Analysis Time | ≤35 min per sample |
| Sample Processing | Integrated proprietary pretreatment kit and reagents |
| Brand | Jilin University & Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-110SH |
| Pricing | Available Upon Request |
| Detection Limit | Stale rice ≥3 years old |
| Measurement Range | 1–3 years storage duration |
| Accuracy | ±5% relative to reference standard methods |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-5000S |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Type | Sesame Oil Only |
| Detection Time | 20 min |
| Quantification Range | 0.0–100.0% |
| Detection Limit | 3.0% |
| Accuracy | ±2% |
| Brand | HKM (Guangdong Huankai Microbial Technology Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Model | SAJ Series |
| Detection Principle | Enzyme Inhibition + Photometric Colorimetry |
| Detection Channels | 8 or 16 independent optical units |
| Measurement Range | Inhibition Rate 0–100% |
| Absorbance Range | 0–3.0 AU |
| Absorbance Accuracy | ±0.01 (410 nm, 0–2.0 AU), ±0.02 (512 nm & 555 nm, 0–1.0 AU) |
| Repeatability | ±0.5% (transmittance repeatability) |
| Zero Drift | ≤0.1%/3 min |
| Photocurrent Drift | ≤0.1%/3 min |
| Detection Time | 15 s – 30 min per assay |
| Display | 4.3″ color TFT-LCD (480×272 resolution) |
| Data Storage Capacity | Up to 780,000 test records |
| Power Supply | 6400 mAh rechargeable Li-ion battery (≥24 h continuous operation) |
| Dimensions | 300 × 200 × 130 mm |
| Compliance | GB/T 5009.199–2003, GB 5009.33–2010, GB/T 5750.10–2006, NY/T 448–2001 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EnSURE™ |
| Price | USD 3,800 (approx.) |
| Function Type | Single-Parameter Detection |
| Sample Format | Single-Sample Dedicated |
| Wavelength Range | 400–680 nm |
| Detection Time | <15 s |
| Repeatability | <5% RSD |
| Detection Channels | 1 |
| ATP Detection Limit | 0.1 fmol (1 × 10⁻¹⁶ mol) |
| Dynamic Range | 0–9999 RLU |
| Data Storage Capacity | 2000 records |
| Calibration | Auto-calibration within 60 s on power-up |
| Power Supply | Two AA alkaline batteries |
| Weight | 260 g |
| Display | Backlit LCD |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | GDYQ-1000S |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Specificity | Soy Sauce Only |
| Detection Time | 30 minutes |
| Detection Range | 0.0–2.0 g/100 mL |
| Detection Limit | 0.1 g/100 mL |
| Accuracy | ±2% |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with Data Logging, Parameter Configuration, Statistical Processing, and RS232 Communication |
| Sample Prep | Integrated Dedicated Pretreatment Module + Single-Use Reagent Cartridge Kit |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYQ-100M (50 Parameters) |
| Price Range | USD 7,000 – 14,000 |
| Function Type | Multi-Analyte (Simultaneous Quantitative Screening) |
| Sample Applicability | Universal for Solid, Semi-Solid & Liquid Food Matrices |
| Optical Wavelength Range | 400 nm – 630 nm |
| Typical Analysis Time per Parameter | 3–10 minutes |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-103SC |
| Function Type | Single-Analyte Detection |
| Sample Versatility | Multi-Matrix (Solid & Liquid) |
| Optical Wavelength | 538 nm |
| Detection Limit | 10.0 mg/kg (solid), 1.00 mg/L (liquid) |
| Quantification Range | 0.0–600.0 mg/kg (solid), 0.0–60.0 mg/L (liquid) |
| Accuracy | ±5% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 310 × 225 × 125 mm |
| Weight | <1.7 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYQ-110S2 |
| Function Type | Multi-analyte (Methanol + Ethanol) |
| Sample Format | Single-sample dedicated format |
| Wavelengths | 412 nm, 595 nm |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SE2 |
| Function Type | Multi-analyte (POD, TVB-N, pH) |
| Sample Compatibility | Universal for raw meat, poultry, and aquatic products |
| Detection Limits | POD Absorbance ≥0.010 A |
| pH Resolution | 0.1 unit |
| Measurement Ranges | POD: 0.000–2.000 A |
| TVB-N | 0.0–150.0 mg/100g |
| pH | 0.2–14.0 |
| Accuracy | ±10% of full scale (per GB/T 5009.44-2003 validation protocol) |
| Interface | RS-232 & USB 2.0 |
| Data Handling | On-device storage, print output, PC synchronization |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SF |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Compatibility | Multi-Sample Universal Format |
| Detection Time | 10 minutes |
| Detection Limit | 0.1 mg KOH/g |
| Measurement Range | 0.0–30.0 mg KOH/g |
| Accuracy | ±5% (Relative Standard Deviation) |
| Reference Standard | GB/T 5009.37–2003 |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SG |
| Function Type | Single-Analyte Quantitative Detection (Fatty Acid Value) |
| Sample Compatibility | Multi-sample Universal (Paddy Rice, Milled Rice, Rice Flour, and Processed Rice Products) |
| Detection Principle | Micro-titration with Standardized KOH Solution |
| Lower Detection Limit | 5.0 mg KOH / 100 g |
| Measurement Range | 0.0–500.0 mg KOH / 100 g |
| Construction | Chemically Resistant Housing & Precision Micro-burette Assembly |
| Regulatory Alignment | Designed for compliance with GB/T 20569–2006 (Chinese National Standard for Fatty Acid Value Determination in Stored Rice) and supports GLP-aligned documentation workflows |