| Brand | ChemInstruments |
|---|---|
| Origin | USA |
| Model | BP-2000 |
| Load Cell Capacity | 25 lbf (standard), optional 2, 5, 10, and 50 lbf |
| Force Resolution | 0.1% of full scale |
| Maximum Test Force | 50 lbf (222.4 N) |
| Test Speed Range | 0.5–25 IPM (1–64 CPM), adjustable in 0.5 IPM increments |
| Data Acquisition Rate | 1,000–5,000 points/second |
| Test Length Range | 0.25–1.5 in (0.5–3.5 cm), adjustable in 0.25 in (0.5 cm) increments |
| Operating Temperature | 0–70 °C (32–150 °F) |
| Power Input | 85–265 VAC, 50/60 Hz |
| Dimensions (H×W×D) | 63 × 46 × 25 cm |
| Weight | 20 kg |
| Display | 5.7-inch integrated touchscreen interface |
| Data Export | USB to EZ Data software |
| Compliance | Designed for TLMI-1G and PSTC test methods |
| Load Cell Options | 2, 5, 10, 25, and 50 lbf capacities available |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ADE Series |
| Standard Compliance | ASTM E681, EN 45014, GB/T 12474-2008 |
| Operating Pressure Range | 0 to 101 kPa (gauge), adjustable down to –100 kPa (gauge) |
| Maximum Test Temperature | 150 °C |
| Oven Max Temperature | 300 °C |
| Ignition Source | 15 kV, 30 mA pulsed arc, 0.5 s duration |
| Electrode Gap | 3–4 mm |
| Reaction Tube Dimensions | 1400 ± 50 mm length, 60 ± 5 mm ID, ≥2 mm wall thickness (borosilicate glass) |
| Vent Valve Diameter | ≥25 mm |
| Stirring | Magnetic stirrer at tube base |
| Safety Interlock | Dual-door mechanical/electrical interlock with remote activation |
| Flame Detection | Visual + optional thermocouple-assisted detection for non-luminous flames (e.g., H₂) |
| Brand | GOTECH TESTING MACHINES CO., LTD. |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | GT-7013-AD |
| Pricing | Available Upon Request |
| Brand | GOTECH TESTING MACHINES CO., LTD. |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GT-7013-ADP |
| Pricing | Available Upon Request |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY(BP)-10MPa |
| Quotation | Available Upon Request |
| Pressure Range | 0–16 MPa |
| Pressure Control Accuracy | +2% / −1% |
| Timing Range | 1 min – 10,000 h |
| Timing Accuracy | <0.1% |
| Test Channels | 3 independent channels |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Rated Power | 1.5 kW |
| Dimensions (W×D×H) | 600 × 650 × 1850 mm |
| Pressure Source | Imported high-stability positive-displacement pump |
| Compliance Standards | GB/T 6111–2003, GB/T 18252–2000, GB/T 15560–1995, CJ/T 108–1999, ISO 9080:2012, ISO 1167–1:2014, ASTM D1598–22, ASTM F1335–21 |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY(BP)-16MPA |
| Pressure Range | 0–16 MPa |
| Pressure Control Accuracy | +2% / −1% |
| Timing Range | 1 min – 10,000 h |
| Timing Accuracy | <0.1% |
| Test Channels | 3 independent channels |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Rated Power | 1.5 kW |
| Dimensions (W×D×H) | 600 × 650 × 1850 mm |
| Pressure Source | Imported U.S. high-pressure pump (GIANT GXR25) |
| Accumulator | Fenghua Xunjet |
| Solenoid Valves | GSR (Germany) |
| Tubing Fittings | Custom stainless-steel |
| HMI | 10.7″ Delta touchscreen (Taiwan) |
| Pressure Transducer | GEMS 20 MPa (UK) |
| Controller | Delta PLC (Taiwan) |
| Standards Compliance | GB/T 6111–2003, GB/T 18252, GB/T 15560–1995, CJ/T 108–1999, ISO 9080, ISO 1167, ASTM D1598, ASTM F1335 |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY(BP)hyjf |
| Quotation | Upon Request |
| Pressure Range | 0–3 MPa |
| Pressure Control Accuracy | +2% / −1% |
| Timing Range | 1 min – 10,000 h |
| Timing Accuracy | <0.1% |
| Test Channels | 3 / 6 / 9 independent circuits |
| Power Supply | 220 V ±10% |
| Rated Power | 3 kW |
| Dimensions (W×D×H) | 600 × 650 × 1850 mm |
| Primary Pressure Source | Imported high-reliability positive displacement pump |
| Key Components | GIANT GXR25 triplex plunger pump (USA), Bucherma diaphragm-type accumulator (Tianjin), Parker solenoid valves (Germany), custom stainless-steel hydraulic fittings, Mitsubishi LCD HMI (Japan), 3 MPa precision pressure transducer (Anhui), Mitsubishi programmable logic controller (Japan), industrial-grade PC with embedded control software |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY200N·m |
| Torque Range (Total) | 0–200 N·m |
| Thread Torque Range | 0–100 N·m |
| Axial Force Range | 0.3–30 kN |
| Torque Measurement Accuracy | ±1% FS |
| Twist Angle Range | 0–100,000° |
| Twist Angle Accuracy | ±1% FS |
| Rotational Speed Range | 0–30 rpm |
| Speed Accuracy | ±0.5% FS |
| Max Spacing Between Chucks | 200 mm |
| Specimen Thread Size | M2–M6 (customizable) |
| Power Supply | Single-phase 1.5 kW |
| Dimensions (W×D×H) | ~600 × 700 × 1800 mm |
| Weight | 200 kg |
| Drive System | Panasonic Servo Motor |
| Torque Sensor | High-Precision Strain-Gauge Type |
| Enclosure | Powder-Coated Steel Cabinet |
| Mobility | Integrated Castor-Mounted Trolley |
| Power Options | AC Mains or Optional Li-ion Battery Pack |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-150-BK |
| Quotation | Available Upon Request |
| Test Pressure Range | 0.6–10 MPa |
| Specimen Diameter | φ12–φ630 mm (customizable) |
| Independent Test Channels | 3 (expandable) |
| Pressure Accuracy | ≤ ±1% |
| Constant-Pressure Control Band | –1% to +2% |
| Temperature Control Range | 20–95 °C |
| Temperature Stability | ≤ ±1 °C |
| Temperature Uniformity | ≤ ±1 °C |
| Timing Range | 0–10,000 h |
| Time Display Accuracy | ≤ 0.1% |
| Pressure Sampling Frequency | 0.02 s |
| Power Supply | 3-phase 380 V AC |
| Control Cabinet Dimensions | 700 × 600 × 1800 mm |
| Media Bath | Stainless Steel Inner Tank (custom dimensions available) |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-20 |
| Pressure Range | 0–20 MPa |
| Pressure Display Resolution | 0.001 MPa |
| Pressure Control Accuracy | +2% (upper limit), −1% (lower limit) |
| Temperature Control Range | Ambient to 95 °C |
| Temperature Uniformity | ±1 °C |
| Test Duration Capacity | 0 min to 9999.59 h |
| Maximum Specimen OD | 630 mm |
| Power Supply (Pressure System) | AC 220 V, 1.5 kW |
| Power Supply (Temperature System) | AC 380 V, 4.5 kW |
| Standard Compliance | GB/T 6111, GB/T 15560, ASTM D1598, ASTM D1599, ISO 1167, ISO 12090, EN 922, USP <661>, FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | GCP-527 |
| Pressure Range | 0–55 MPa |
| Pressure Resolution | 0.001 MPa |
| Pressure Control Accuracy | ±0.1% of setpoint |
| Temperature Control Range | Ambient to 95 °C |
| Temperature Display Accuracy | ±1 °C |
| Test Duration Range | 0 min to 9999.59 h |
| Time Resolution | 1 s |
| Power Supply (Pressure System) | AC 380 V, 1.5 kW |
| Power Supply (Temperature System) | AC 380 V, 9 kW |
| Compliance | ISO 1167, GB/T 6111 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | GCP-527 |
| Pressure Range | 0–55 MPa |
| Pressure Resolution | 0.001 MPa |
| Pressure Control Accuracy | ±0.1% of setpoint |
| Temperature Control Range | Ambient to 95 °C |
| Temperature Display Accuracy | ±1 °C |
| Test Duration Range | 0 min to 9999.59 h |
| Time Resolution | 1 s |
| Power Supply (Pressure System) | AC 380 V, 1.5 kW |
| Power Supply (Temperature System) | AC 380 V, 9 kW |
| Compliance | ISO 1167, GB/T 6111 |
| Brand | Qinji |
|---|---|
| Model | GCP-527 |
| Type | Tri-Station Static Hydrostatic Pressure Tester |
| Compliance | ISO 1167, GB/T 6111 |
| Pressure Range | 0–10 MPa |
| Pressure Resolution | 0.001 MPa |
| Pressure Control Accuracy | ±0.1% of setpoint |
| Temperature Control Range | Ambient to 95 °C |
| Temperature Uniformity | ±1 °C |
| Test Duration Range | 0 min to 9999 h 59 min |
| Time Resolution | 1 s |
| Power Supply (Pressure System) | AC 380 V, 1.5 kW per station |
| Power Supply (Heating System) | AC 380 V, 9 kW total |
| Station Count | 3 independent test stations |
| Sample Diameter | Customizable per user requirement |
| Data Output | Automated calculation and thermal printing |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WSB-16 |
| Pricing | Available Upon Request |
| Max. Test Pressure | 0–16 MPa |
| Max. Specimen OD | ≤110 mm |
| Pressure Accuracy | ≤±1% FS |
| Constant-Pressure Control Band | –1% to +2% of setpoint |
| Temperature Range | Ambient to 95 °C |
| Temp. Uniformity & Stability | ≤±1 °C |
| Pressure Sampling Interval | 0.3 s |
| Test Duration Range | 1 s – 9999 h |
| Concurrent Test Channels | 3 independent circuits |
| Power Supply | 3-phase AC 380 V, 50 Hz |
| Control Cabinet Dimensions | 650 × 600 × 1800 mm |
| Heating Medium | Stainless Steel Water Bath with External Circulation System |
| Compliance | GB/T 6111–2003, GB/T 15560–1995, ISO 1167-1:2014, ASTM D1598, EN ISO 1167-2:2014 |