Refractometer
Filter
Showing 1–30 of 537 results
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | AR4 |
| Product Type | Benchtop Abbe Refractometer |
| Temperature Control | Yes |
| Digital Display | No |
| Measurement Range | 1.3000 – 1.7000 nD |
| Accuracy | ±0.0002 nD |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Model | DR301-95 |
| Sample Measurement Range | 1.3330–1.5318 nD |
| Measurement Accuracy | ±0.00015 nD |
| Temperature Range | 5–40 °C |
| Temperature Accuracy | ±0.5 °C |
| Resolution | 0.0001 nD |
| Display | Digital LCD |
| Power Supply | 9 V battery (detachable AC adapter optional) |
| Prism Material | Optical glass |
| Housing Material | Stainless steel sample stage + polymer body |
| Dimensions | 180 × 100 × 60 mm |
| Weight | 500 g |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Model | DR6000 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, 10–80 °C (±0.1 °C) |
| Digital Display | Yes |
| Refractive Index Range | nD 1.3200–1.5800 (standard), up to 1.7000 with extended Brix mode |
| Accuracy | ±0.0001 nD |
| Resolution | 0.0001 nD |
| Brix Range | 0–95 % |
| Brix Accuracy | ±0.1 % |
| Brix Resolution | 0.1 % |
| Prism Material | Sapphire |
| Light Source | 590 nm LED (>100,000 h lifetime) |
| Measurement Time | ~4 s |
| Interface | RS-232, USB, Ethernet |
| Data Storage | Integrated SQL database (99 methods, 999 results) |
| Compliance | GLP, FDA 21 CFR Part 11 ready, ICUMSA-compliant temperature compensation |
| IP Rating | IP65 (measurement cell) |
| Power Supply | 90–260 V AC, 50/60 Hz, 60 W |
| Operating Ambient | 15–35 °C |
| Sample Temp Range | 10–80 °C |
| Temperature Sensor | PT100 |
| Display | 5.7″ LCD (320 × 240 px), touchscreen |
| Brand | ACM |
|---|---|
| Origin | Austria |
| Model | LR.10 |
| Type | Online Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 0–30 °Brix |
| Accuracy | ±0.005 °Brix |
| Operating Temperature | 0–50 °C |
| IP Rating | IP65 |
| Communication Interface | RS485, Profibus |
| Compliance | Designed for hygienic process environments (CIP-compatible, 10 bar pressure rating) |
| Origin | USA |
|---|---|
| Type | In-line refractometer |
| Model | 614 |
| Measurement Range | 1.3000–1.6000 RIU (Refractive Index Units) |
| Accuracy | ±0.5% of full scale |
| Temperature Compensation | Automatic, -25°C to +150°C |
| Process Pressure Rating | Up to 1000 PSIG (68 bar) |
| Prism Material | Sapphire |
| Output Signals | 4–20 mA, 0–10 VDC (refractive index and temperature) |
| Communication Interfaces | RS-232, dual RS-485 (up to 3 km remote operation) |
| Cable Length | Up to 500 m |
| Display | Backlit LCD with 5-touch-button interface |
| Alarm Functions | Two independent alarms (out-of-range and system fault) |
| Power Supply | 230 VAC, 50 Hz, <25 W |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | FEA-5023 |
| Product Type | Handheld Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.3330–1.5290 |
| Ethanol Concentration Range (v/v) | 3%–13% |
| Measurement Precision (Refractive Index) | ≤ ±0.003 RIU (equivalent to ≤3% relative error in ethanol quantification) |
| Dimensions | 250 × 200 × 75 mm |
| Power Consumption | 5 W |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −10–50 °C |
| Operating Humidity | 20–80% RH |
| Storage Humidity | 5–90% RH |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, ±0.03 °C accuracy (verified by T-Check system) |
| Display | Digital LCD |
| Refractive Index Range | 1.33 to 1.55 nD |
| Accuracy | ±0.0001 nD |
| Sample Volume | As low as 70 µL |
| Prism Material | Sapphire (Mohs hardness 9) |
| Measurement Cycle Time | As low as 10 seconds |
| Additional Scales | Brix, % w/w, % v/v, g/100g, etc. |
| Predefined Methods | 1 primary + 8 swappable application-specific methods |
| Compliance | Fully traceable temperature calibration |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Abbemat 3200 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.30 to 1.72 |
| Refractive Index Accuracy | ±0.0001 |
| Measurement Time | ~5 s (after thermal equilibration) |
| Sample Volume | ~0.2 mL |
| Light Source | LED at 589 nm |
| Interface | RS-232, 2× USB, Ethernet, LIMS-compatible |
| Display | 5.8-inch color touchscreen |
| Dimensions (W×H×D) | 228 × 94 × 300 mm |
| Weight | 4.6 kg |
| Prism Material | Sapphire |
| Wetted Materials | Sapphire, perfluoroelastomer, PP-GF30, stainless steel |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Abbemat 350 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.26–1.72 |
| Refractive Index Accuracy | ±0.0001 |
| Temperature Control Range | 4–85 °C |
| Temperature Stability | ±0.002 °C |
| Minimum Sample Volume | ~0.2 mL |
| Measurement Time (post-equilibration) | 5 s |
| Light Source | LED, 589 nm, >100,000 h lifetime |
| Prism Material | Sapphire |
| Compliant with | FDA 21 CFR Part 11, GMP, GAMP 5, USP <851>, Ph. Eur., JP |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Abbemat 450 / Abbemat 650 / Abbemat HT / Abbemat MW |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Accuracy | ±0.00001 (Abbemat 450), ±0.000001 (Abbemat 650 & HT) |
| Refractive Index Range | 1.26–1.72 (450/650), 1.30–1.72 (HT) |
| Brix Range | 0–100% |
| Temperature Range | 4–85 °C (450/650), 10–110 °C (HT) |
| Wavelength | 589.3 ± 0.1 nm (Na D-line) |
| Light Source | LED (>100,000 h lifetime) |
| Prism Material | Synthetic Sapphire (450/650), YAG (HT/MW) |
| Minimum Sample Volume | ~0.2 mL |
| Measurement Time | 5 s (post-thermal equilibrium) |
| IP Rating | IP68 (450/650) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready, 3Q Documentation Available (DQ/IQ/OQ/PQ) |
| Connectivity | RS-232, CAN bus, Ethernet, VGA |
| Software | Windows-based PDC (Precision Data Control) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.33 nD to 1.55 nD |
| Measurement Accuracy | ±0.0001 nD |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Abbemat 550 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range (nD) | 1.26–1.72 |
| Refractive Index Accuracy (nD) | ±0.000001 |
| Refractive Index Precision (nD) | ±0.000001 |
| Brix Range | 0–100 % |
| Brix Accuracy | ±0.015 % |
| Temperature Control Range | 4–85 °C |
| Temperature Stability | ±0.002 °C |
| Temperature Probe Accuracy | ±0.03 °C |
| Wavelength | 589 nm (Na-D line) |
| Minimum Sample Volume | ~0.2 mL |
| Measurement Time (post-equilibration) | 5 s per sample |
| Light Source | LED (Lifespan > 100,000 h) |
| Prism Material | Sapphire (Vickers hardness ≈ 2000 HV) |
| Compatible Sample Types | Liquids, pastes, polymers, solids, turbid, colored, and opaque materials |
| Compliance | FDA 21 CFR Part 11, GMP, GAMP 5, USP <1058>, Ph. Eur., JP |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Abbemat 7001 / Abbemat 7201 |
| Form Factor | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.33 nD to 1.55 nD (Abbemat 7001) |
| Refractive Index Accuracy | ±0.0001 nD (7001) |
| Refractive Index Resolution | 0.0001 nD (7001) |
| Temperature Range | 20 °C to 40 °C (7001) |
| Temperature Accuracy | ±0.05 °C (7001) |
| Brix Range | 0–100 °Brix |
| Brix Accuracy | ±0.05 °Brix (7001) |
| Sample Volume | 70 µL (microflow cell) |
| Max Operating Pressure | 10 bar |
| Prism Material | Synthetic Sapphire (Mohs hardness 9) |
| Light Source | LED @ 589.3 nm (interference filter stabilized) |
| Interface | 1× Ethernet, 3× USB-B, CAN bus for DMA/MCP/SVM/Xsample integration |
| Data Storage Capacity | 10,000 measurements (7001) |
| Compliance | 21 CFR Part 11, EU GMP Annex 11, GAMP 5, ISO/IEC 17025 applicable |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.26–1.72 |
| Accuracy (nD) | ±0.0001 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Integrated Peltier |
| Digital Display | Yes |
| Refractive Index Range | 1.30–1.72 nD |
| Refractive Index Accuracy | ±0.000001 nD |
| Wavelength Options | 8 discrete wavelengths from 435.8 nm to 656.3 nm |
| Prism Material | YAG (Yttrium Aluminum Garnet) |
| Sample Volume | ~0.2 mL |
| Measurement Time per Sample | 5 s (after thermal equilibration and filter switching) |
| Temperature Range | 10–70 °C |
| Temperature Stability | ±0.002 °C |
| Calibration | Single- or two-point |
| Interface | RS-232 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Abbemat Series |
| Temperature Control | Yes |
| Digital Display | Yes |
| IP Rating | IP68 (Abbemat 450/650) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP |
| Measurement Principle | Critical Angle Method with LED-based Sodium D-Line (589.3 ± 0.1 nm) |
| Prism Material | Synthetic Sapphire (Abbemat 450/650), YAG (Abbemat HT/MW) |
| Minimum Sample Volume | ~0.2 mL |
| Measurement Time | <5 s (after thermal equilibration) |
| Temperature Range | −42 to +85 °C (Abbemat 450/650), 10 to 110 °C (Abbemat HT), adjustable for MW models |
| Refractive Index Range | 1.26–1.72 (nD), accuracy ±0.00002 to ±0.00004 nD |
| Brix Range | 0–100 %, resolution 0.001 % |
| Temperature Stability | ±0.002 °C |
| Light Source | Long-life LED (>100,000 h) |
| Interfaces | RS-232, CAN bus, Ethernet, VGA (PC-dependent) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Carbo |
| Product Type | Online Refractometer-Based CO₂ Sensor |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 0–20 g/L (0–10 vol%) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 1T |
| Measurement Range | nD 1.3000–1.7000 / Brix 0.0–95.0% |
| Resolution | 0.001 (nD) / 0.5% (Brix) |
| Accuracy | ±0.0002 (nD) / ±0.1% (Brix) |
| Temperature Range | 0.0–50.0°C (Resolution: 0.1°C, Accuracy: ±0.2°C) |
| Light Source | 8 V, 0.15 A tungsten lamp |
| Power Supply | 100–240 VAC, 50/60 Hz, 6 VA |
| Dimensions & Weight | 13 × 18 × 23 cm, 3.4 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 60-C5 |
| Temperature Range | 10–60°C (water) |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.2°C |
| Bath Capacity | 1.0 L |
| Power Consumption | 250 VA |
| Input Voltage | AC 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 20.4 × 33.6 × 28.9 cm |
| Weight | 9.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 60-C5 |
| Temperature Range | 10–60°C |
| Temperature Resolution | 0.1°C |
| Temperature Stability | ±0.2°C |
| Bath Capacity | 1.0 L |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 250 VA |
| Dimensions (W×D×H) | 20.4 × 33.6 × 28.9 cm |
| Net Weight | 9.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | ATAGO 60-C5 |
| Product Type | Benchtop Refractometer Accessory |
| Temperature Control | Yes |
| Digital Display | Yes |
| Temperature Range | 10–60°C (water) |
| Temperature Accuracy | ±0.2°C |
| Resolution | 0.1°C |
| Tank Capacity | 1.0 L |
| Power Input | AC 100–240 V, 50/60 Hz |
| Power Consumption | 250 VA |
| Dimensions (W×D×H) | 20.4 × 33.6 × 28.9 cm |
| Weight | 9.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-1Sα |
| Product Type | Online Refractometer |
| Measurement Range | Refractive Index (nD): 1.32000–1.49100, Brix: 0.0–80.0% |
| Accuracy | ±0.0002 (nD), ±0.1% (Brix) |
| Display | Digital |
| Temperature Control | None |
| Explosion Protection Rating | Ex ia IIB T3 Ga TA |
| Compliance | ATEX, IECEx, UL/cUL Class I, Div 1, Groups A, B, C, D |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α |
| Product Type | In-Line Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | Brix 0.0–80.0% (ATC) |
| Accuracy | ±0.1% Brix |
| Temperature Compensation Range | 5–100°C |
| Operating Temperature | −15–160.0°C |
| Environmental Operating Temp | 5–40°C |
| Resolution | 0.01% (≤9.99%), 0.1% (≥10.0%) Brix |
| Temperature Resolution | 1°C/°F |
| Output | DC 4–20 mA, RS-232C |
| Measurement Interval | Adjustable (default 1 s) |
| IP Rating | IP67 |
| Light Source | LED (≈589 nm, sodium D-line equivalent) |
| Power Supply | DC 24 V (AC 100 V optional with AD-32 adapter) |
| Prism Material | Synthetic Sapphire |
| Body Material | SUS316L stainless steel |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α |
| Product Type | In-line Refractometer |
| Brix Range | 0.00–80.00% (with Automatic Temperature Compensation, ATC) |
| Brix Accuracy | ±0.1% |
| Temperature Range | −15–160.0°C |
| ATC Range | 5–100°C |
| Resolution | Brix 0.01% (≤9.99%), 0.1% (>10.0%) |
| Temp | 1°C/°F |
| Output | DC 4–20 mA, RS-232C |
| Measurement Interval | ~1 sec (configurable up to 5 intervals) |
| IP Rating | IP67 |
| Light Source | LED (approx. 589 nm, sodium D-line equivalent) |
| Prism Material | Synthetic Sapphire |
| Body Material | SUS316L Stainless Steel |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Power Supply | DC 24 V (AC 100 V optional with AD-32 adapter) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α (Liquid Inline Concentration Sensor) |
| Product Type | Inline Refractometer |
| Brix Range | 0.00–80.00 (ATC) |
| Brix Accuracy | ±0.1% |
| Temperature Range | −15–160.0°C / 5.0–320.0°F |
| ATC Range | 5–100°C |
| Resolution | Brix 0.01% (≤9.99%), 0.1% (>9.99%) |
| Temperature Resolution | 1°C/°F |
| Output | DC 4–20 mA, RS-232C (refractive index or Brix selectable) |
| Measurement Interval | ~1 s (configurable in 5 steps) |
| IP Rating | IP67 |
| Light Source | LED (≈589 nm, sodium D-line equivalent) |
| Prism Material | Synthetic Sapphire |
| Body Material | SUS316L stainless steel |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Power Supply | DC 24 V (AC 100 V optional with AD-32 adapter) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α |
| Product Type | Inline Refractometer |
| Measurement Range | Brix 0.00–80.00 (ATC) |
| Accuracy | ±0.1% Brix |
| Display | Digital |
| Temperature Compensation | Automatic (ATC) |
| Installation Type | Pipe-mounted, Flow-through |
| Power Supply | DC 24 V |
| Output Signal | 4–20 mA / RS-485 (Modbus RTU) |
| IP Rating | IP65 |
| Process Connection | G1/2" or 1/2" NPT (optional) |
| Wetted Materials | SUS316L stainless steel prism & flow cell |
| Operating Temperature | 0–60 °C (process fluid) |
| Response Time | < 2 s (90% step change) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α Soymilk |
| Type | In-line Refractometer |
| Display | Digital |
| Measurement Range | Brix 0.0–80.0% |
| Accuracy | ±0.1% Brix |
| Temperature Control | Not Integrated |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration support |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α-H2O2 |
| Product Type | In-line Refractometer |
| Measurement Range | 0.0–50.0% (w/w) H₂O₂ with Automatic Temperature Compensation (ATC) |
| Accuracy | ±0.6% (w/w) |
| Resolution | 0.2% (w/w), 1°C/°F |
| Temperature Measurement Range | −15 to 160°C |
| ATC Range | 10–35°C |
| Ambient Operating Temperature | 5–40°C |
| Measurement Interval | ~1 second (configurable up to 5 preset intervals) |
| Output | DC 4–20 mA and RS-232C |
| Light Source | LED (approximating sodium D-line, 589 nm) |
| Prism Material | Synthetic Sapphire |
| Body Material | SUS316L Stainless Steel |
| IP Rating | IP67 |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Power Supply | DC 24 V (AC 100 V optional via AD-32 adapter) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α-NaOH |
| Product Type | In-line Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 0.0–38.0% (w/w NaOH) |
| Accuracy | ±0.2% (w/w) |
| Temperature Range | −15 to 160°C |
| Temperature Compensation | Automatic (10–35°C) |
| Output | 4–20 mA & RS-232C |
| IP Rating | IP67 |
| Prism Material | Synthetic Sapphire |
| Housing Material | SUS316L |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Power Supply | DC 24 V (AC 100 V optional with AD-32 adapter) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Product Type | In-line Refractometer |
| Model | CM-800α-NMP |
| Measurement Range | 0.0–100.0% (NMP concentration, w/w) |
| Accuracy | ±0.1% |
| Display | Digital LCD |
| Temperature Control | Not integrated |
| Compliance | Designed for industrial process monitoring in ISO/IEC 17025-aligned environments |
| Regulatory Context | Supports GLP/GMP-relevant traceability when paired with validated data logging systems |