| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuPoint |
| Price | Upon Request |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | AQT200 |
| Package Quantity | 100 swabs per box |
| Storage Conditions | 2–8 °C (refrigerated) for up to 12 months |
| Intended Use | Total ATP quantification in rinse water and surface rinse samples from food processing equipment and CIP systems |
| Compatible Instrument | 3M Clean-Trace NG Luminometer |
| Output Unit | Relative Light Units (RLU) |
| Regulatory Context | Designed for use in environments compliant with HACCP, GMP, and FDA 21 CFR Part 11–aligned data integrity workflows |
| Application Scope | Food & beverage manufacturing, dairy, meat & poultry, seafood, produce, beverages, bottled water, pet food, nutraceuticals, and bakery |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | AQT200 |
| Package Quantity | 100 swabs per box |
| Storage Conditions | 2–8 °C (refrigerated) for up to 12 months |
| Intended Use | Total ATP quantification in rinse water and surface rinse samples from food processing equipment and CIP systems |
| Compatible Instrument | 3M Clean-Trace NG Luminometer |
| Output Unit | Relative Light Units (RLU) |
| Compliance Context | Designed for use in HACCP, GMP, and FSMA-aligned environmental monitoring programs |
| Application Scope | Food & beverage manufacturing, dairy, meat & poultry, seafood, produce, beverages, confectionery, pet food, and ingredient processing facilities |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | Clean-Trace ATP LM1 |
| Detection Principle | ATP-dependent bioluminescence assay |
| Sample Types | Surface swabs (UXL100), total aqueous ATP (AQT200), free aqueous ATP (AQF100) |
| Compliance | Designed for use in food safety hygiene monitoring per ISO 22000, HACCP, and FDA Food Code guidance |
| Software | 3M Clean-Trace Hygiene Management Software with wireless data sync, audit-trail-capable reporting, and 21 CFR Part 11–ready configuration options |
| Portability | Handheld, battery-operated, integrated cradle charging station |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | Clean-Trace ATP LM1 |
| Detection Principle | ATP-dependent bioluminescence assay |
| Sample Types | Surface swabs (UXL100), water samples (AQT200, AQF100) |
| Data Connectivity | Wireless (Bluetooth/Wi-Fi enabled) |
| Software Platform | 3M Clean-Trace Hygiene Management Software |
| Compliance Support | Designed for use in environments requiring adherence to HACCP, ISO 22000, FDA Food Code, and GMP-aligned hygiene verification protocols |
| Power | Rechargeable battery with AC adapter |
| Portability | Handheld, ergonomic design for single-hand operation |
| Brand | 3M |
|---|---|
| Origin | USA |
| Model | LM1 |
| Detection Principle | ATP-dependent luciferase bioluminescence assay |
| Sample Types | Surface swabs (UXL100), free ATP in water (AQF100), total ATP in water (AQT200) |
| Software | Clean-Trace Hygiene Management Software with wireless connectivity, automated reporting, and audit-ready data logging |
| Compliance Context | Designed for use in environments requiring adherence to HACCP, ISO 22000, FDA Food Safety Modernization Act (FSMA), and GMP-aligned hygiene verification protocols |
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Clean-Trace™ |
| Pricing | Upon Request |
| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 3M™ Clean-Trace™ NGI |
| Pricing | Available Upon Request |
| Weight | 400 g |
| Detection Range | 0–999,999 RLU |
| Sensitivity | 10⁻¹⁵ mol ATP |
| Read Time | 10 s |
| Repeatability (CV%) | 7.4% |
| Data Storage | 10,000 test results |
| Sampling Plans | 100 plans (up to 300 points each) |
| Plan Points | 2,000 total |
| Display | 240 × 160-pixel backlit LCD |
| Battery | Rechargeable Li-ion, 36 h continuous operation |
| Auto-Diagnostics | Power-on self-test & real-time fault alerting |
| Sample Chamber | Auto-sensing lid with timeout alarm |
| Software | Trend analysis with 9 filtering modes, 5 report templates, 10 chart types, Excel export |
| User Management | Customizable role-based permissions |
| ATP Reagent Format | Pre-loaded liquid luciferin/luciferase in swab |
| Brand | AGDIA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XCS66800/0048 |
| Price Range | USD 999–9,999 |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | APN-I |
| Price | USD 1,400 (approx.) |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BY-2012ATP |
| Detection Range | 0–9999 RLU |
| Detection Limit | 5×10⁻¹⁵ mol ATP |
| Detection Time | ≤15 s |
| Accuracy | ±5 RLU |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–85 % RH |
| ATP Recovery Rate | 90–110 % |
| Display | Large Backlit LCD |
| User Accounts | 50 |
| Custom Limits | 250 |
| Data Storage Capacity | 2000 test records |
| Pass/Fail Auto-Judgment | Yes |
| Built-in Self-Calibration Light Source | Yes |
| Self-Test at Power-On | Yes (30 s) |
| Interface | RS232 + USB |
| Dimensions (W×H×D) | 192 × 87 × 34 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CariScreen |
| Price Range | USD 2,800–7,000 |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | novaLUM |
| Price Range | USD 6,800 – 34,000 (FOB) |
| Detection Principle | Firefly Luciferase–Luciferin Bioluminescence Reaction |
| Read Time | ≤5 s |
| Sensitivity | <1 fmol ATP |
| Storage Capacity | 5,000 test records |
| Sample Points per Plan | Up to 400 |
| Power | Rechargeable Li-ion battery (8–10 h runtime) |
| Weight | <450 g |
| Calibration | Automated on-board calibration |
| Connectivity | USB & Bluetooth to novaLINK Software |
| Keyboard | Full digital keypad |
| Detector | High-gain photomultiplier tube (PMT) |
| Multi-assay Capability | 8 independent assay configurations |
| Compliance | Designed for ISO 22000, HACCP, FDA Food Code, and USDA FSIS sanitation verification protocols |
| Brand | CSY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CSY-ATP |
| Price Range | USD 1–999 (FOB) |
| Detection Principle | Luciferin–Luciferase Bioluminescent Reaction |
| Detection Unit | RLU (Relative Light Unit) |
| Sensitivity | 1 × 10⁻¹⁶ mol ATP |
| Dynamic Range | 1–9999 RLU (customizable up to 999999) |
| Measurement Time | ≤10 s per sample |
| Repeatability | ≤±5% CV |
| Sample Point Capacity | ≥2000 unique locations |
| Data Storage | ≥20,000 test records |
| Connectivity | USB 2.0, Bluetooth 4.2, Wi-Fi 802.11 b/g/n |
| Result Interpretation | Pre-programmed RLU-to-Cleanliness-Level mapping (e.g., Pass/Alert/Fail) with configurable thresholds |
| Brand | DW |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | DW-Biolaser902 |
| Pricing | Upon Request |
| Principle | Laser-Induced Autofluorescence + Mie Scattering |
| Particle Size Range | 0.5–10 µm |
| Detection Resolution | Single Bio-Particle |
| Sampling Flow Rate | ≥2 L/min |
| Excitation Wavelength | 405 nm Semiconductor Laser |
| Max Detection Rate | 5,000 bio-particles/sec |
| Measurement Cycle | 1 min (configurable) |
| Power Consumption | 12 W |
| Operating Temperature | 5–40 °C |
| Relative Humidity | <90% RH |
| Dimensions | 550 × 225 × 248 mm |
| Brand | HJ Purification (HJ) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FX-ATP |
| Price | USD 1,550 (approx.) |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP9505-04 |
| Detection Range | 0–10⁷ RLU |
| Microbial Count Display | 0–10¹⁷ CFU/mL |
| Spectral Response | 300–650 nm |
| Integration Time | 1–300 s (user-adjustable) |
| Data Storage | 2,000 test records |
| Repeatability | ≤3% |
| Background Count Rate | ≤30 s⁻¹ |
| Dimensions | 190 × 100 × 70 mm |
| Operating Temperature | 5–30 °C |
| Relative Humidity | ≤85% |
| Power Supply | Dual AC/DC |
| Brand | HJ |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Region Category | Domestic (China) |
| Model | FX-10ATP |
| Price | ¥13,000 |
| Detection Range | 0–99,999 RLU |
| Sensitivity | 1×10⁻¹⁶ mol ATP |
| Repeatability | ≤1% CV |
| Display | ≥3.5-inch color TFT touchscreen with Chinese UI |
| Configurable Limits | Up to 300 threshold values |
| Data Storage | ≥30,000 test records |
| Assay Time | 10 seconds per measurement |
| Detection Limit | 1.4 CFU (equivalent, based on ATP-to-microbial-correlation) |
| Rated Voltage | 3.3 V DC |
| Power Source | Rechargeable lithium-ion battery |
| Continuous Operation Capacity | ≥2,000 consecutive measurements |
| Upgrade Path | Optional modules for food additives, preservatives, colorants, and toxic contaminants (e.g., H₂O₂, formaldehyde, methanol) |
| Optical System | Dual-cuvette design with solid-state LED excitation source |
| Built-in Auto-Calibration | Self-calibrating light source |
| Brand | Hygiena |
|---|---|
| Origin | USA |
| Model | Pi-102 |
| Detection Limit | 1 × 10⁻¹⁸ mol ATP/assay |
| Measurement Time | Adjustable from 0.2 to 100 s (default 5 s) |
| Output Units | RLU (Relative Light Units) and fg (femtograms of bacterial ATP) |
| Memory Capacity | 800 stored results with category tagging |
| Display | LCD |
| Dimensions | 208 × 105 × 57 mm (L × W × H) |
| Weight | 1.5 kg |
| Measurement Range | 0–3,000,000 RLU |
| Accuracy | ±5% |
| Power Supply | Rechargeable Ni/Cd battery + AC adapter |
| Connectivity | Real-time data transmission to PC via USB |
| Brand | Hygiena |
|---|---|
| Origin | United Kingdom |
| Model | SystemSURE II |
| Detection Range | 0–9999 RLU |
| Detection Time | 15 s |
| Resolution | 1 RLU |
| Accuracy | ±5 RLU or ±5% |
| Data Storage | 500 results |
| Operating Temperature | 5–40 °C |
| Relative Humidity (Operating) | 20–85% non-condensing |
| Storage Temperature | −10–40 °C |
| Battery | 2 × AA (alkaline, 2600 mAh |
| Interface | EIA-232 compatible serial port |
| Power Life | ≥6 months at 20 °C (6000 tests) |
| Brand | Hygiena |
|---|---|
| Origin | United Kingdom |
| Model | SystemSURE PLUS |
| Detection Range | 0–9999 RLUs |
| Sensitivity | up to 2×10⁻¹⁶ mol ATP |
| Response Time | 15 s (calibration), 15 s (measurement) |
| Display | 45 mm × 45 mm LCD |
| Weight (with batteries) | 260 g |
| Power | 2 × AA alkaline batteries (≈3000 tests per set) |
| Data Storage | 2000 results |
| User Accounts | ≥200 |
| Test Protocols | ≥5000 |
| Detection Programs | ≥100 |
| RLU Resolution | 1 RLU |
| Blank Background | 0–1 RLU |
| ATP Recovery Rate | 92% |
| Swab Shelf Life | ≥12 months at 2–8 °C |
| Compliance | CE-marked, ISO 22000-aligned, validated for HACCP/SSOP verification |
| Brand | Hygiena |
|---|---|
| Origin | USA |
| Model | SystemSURE PLUS™ |
| Detection Range | 0–9999 RLU |
| Resolution | 1 RLU |
| Measurement Time | 15 s |
| Accuracy | ±5% or ±5 RLU |
| Data Storage Capacity | 2000 results |
| Operating Temperature | 5–40 °C |
| Relative Humidity (Operating) | 20–85% non-condensing |
| Storage Temperature | −10–40 °C |
| Relative Humidity (Storage) | 20–95% non-condensing |
| Dimensions (W×H×D) | 72 × 191 × 32 mm |
| Weight (with batteries) | ~269 g |
| Power Supply | 2 × AA (LR6/E91), alkaline (1.5 V nom.) or rechargeable NiMH/NiCd (1.2 V nom.) |
| Battery Life | ≥6 months at 20 °C (alkaline, standby) |
| Interface | EIA-232 (RS-232) compatible |
| User-Programmable Limits | 251 |
| Customizable Protocols | 251 |
| Program Groups | 20 |
| User ID Support | Yes |
| Software Included | SURE Trend™ v4.x |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYQ-131SA |
| Detection Time | 10 s |
| Detection Range | 0–9999 RLU |
| Limit of Detection | 4×10⁻¹⁸ mol ATP |
| Detection Lower Limit | 1 CFU/mL |
| Repeatability | ≤15% CV |
| Correlation Coefficient | ≥0.995 |
| Measurement Error | ±5% or ±5 RLU |
| Threshold Groups | 100 |
| Data Storage Capacity | >2000 records |
| Operating Temperature | 5–40 °C |
| Operating Relative Humidity | 20–80% RH |
| Weight | ~260 g |
| Battery Life | Up to 20 h continuous operation |
| Interface | USB/Bluetooth data export |
| Software Compatibility | Windows-based analysis suite with pass/fail logic engine |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PD-30 |
| Price Range | USD 1,400 – 2,800 |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LB-QM6 |
| Detection Sensitivity | 1×10⁻¹⁵ mol ATP |
| RLU Range | 0–999,999 RLU |
| Background Noise | ≤2 RLU |
| Detection Limit | 1.0 CFU/mL |
| Assay Time | 10 s |
| Accuracy | ±5% or ±5 RLU |
| Overrange Protection | Tilt-activated interruption |
| Display | 3.5-inch color TFT LCD |
| Data Storage | 10,000 records |
| Connectivity | USB + Bluetooth v5.0 |
| Output Options | Optional Bluetooth thermal printer |
| Power Supply | Rechargeable Li-ion battery (AC travel charger included |
| Battery Life | >10 h |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–80% RH |
| Dimensions | 70 × 35 × 190 mm |
| Weight | 300 g |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Model | EQ-ATP01 |
| Type | Portable ATP Bioluminescence Analyzer |
| Detection Principle | Firefly Luciferase–Luciferin Bioluminescent Reaction |
| Measurement Range | 0–99999 RLU (Relative Light Units) |
| Detection Time | ≤15 seconds per sample |
| Sample Volume | 10–100 µL |
| Power Source | Rechargeable Li-ion battery (≥8 hours continuous operation) |
| Interface | USB-C & Bluetooth 5.0 |
| Compliance | ISO 22000, HACCP, FDA Food Code Annex 3, EN 13697 (for surface hygiene validation) |
| Brand | Royal Biotech GmbH |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RVLM |
| Price | Upon Request |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-ATP |
| Display | 3.5-inch full-color touchscreen (≥5-color UI) |
| Processor | 32-bit high-speed data processing IC |
| Detection Time | 15 s |
| Measurement Interference | ±5% or ±5 RLU |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–85% RH |
| Output Unit | RLU (Relative Light Unit) |
| Pass/Fail Auto-Judgment | Yes |
| Compliance Reporting | Automatic pass rate statistics |
| Built-in Calibration Light Source | Yes |
| Power-On Self-Test Duration | 30 s |
| Connectivity | Mini-USB port + integrated Wi-Fi module |
| Software Delivery | Dedicated USB drive (no CD) |
| Dimensions (W×H×D) | 188 × 77 × 37 mm |
| Power Supply | Rechargeable lithium-ion battery |
| Standby Life (20 °C) | 6 months |
| Standard Accessories | Host unit, aluminum carrying case, driver USB stick, PC data cable, desktop data analysis software, Chinese user manual |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TE-A420 |
| Price | USD 630 (FOB) |
| Detection Range | 0–9999 RLU |
| Limit of Detection | ≤1.0 CFU/mL |
| Measurement Precision | 2×10⁻¹⁸ mol ATP |
| Background Noise | ≤2 RLU |
| Assay Time | 10 s per sample |
| Data Storage Capacity | ≥2000 records |
| Interface | USB |
| Temperature Operating Range | 5–40 °C |
| Relative Humidity Range | 20–85 % RH |
| Configurable Alert Thresholds | ≥100 user-defined limits |
| Interference Tolerance | ±5 RLU or ±5 % |