Explosives Detection Instruments
Filter
Showing all 26 results
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FLA 2.1 |
| Price Range | USD 27,000 – 68,000 |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SC-2 |
| Price Range | USD 27,000 – 68,000 |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPD2.2 |
| Price Range | USD 27,000 – 68,000 |
| Compliance | ASTM E1226, ASTM E1515, EN 14034-1:2004+A1:2011, EN 14034-2:2006+A1:2011, EN 14034-3:2006+A1:2011 |
| Vessel Volume | 20 L |
| Vessel Material | AISI 316 Stainless Steel |
| Maximum Working Pressure | 40 bar (gauge) |
| Pressure Measurement Range | 0–25 bar (absolute) |
| (dp/dt)max Detection Threshold | >4000 bar/s |
| Kst Range | >1000 bar·m/s |
| Explosibility Parameters | LEL/UEL/MEC from 0 g/m³, LOC: 1–21 % O₂ |
| Dust Injection Valve Response Time | ≤30 ms |
| Vacuum Display Range | 0–1 bar (absolute) |
| Vacuum Control | Auto & Manual Modes |
| Vessel Temperature Monitoring | Front-panel digital readout |
| Data Acquisition Rate | 10–100 kHz |
| Software | ANKO Explosion Plotter v3.x (GLP-compliant reporting, audit trail, test sequence automation, noise-filtered signal processing, PDF report generation) |
| Accessories | Integrated vacuum pump unit, exhaust scrubber with flow controller, borosilicate observation viewport, dedicated workstation, thermal printer |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM Type |
| Price Range | USD 27,000 – 68,000 (FOB Hamburg) |
| Compliance | BAM Method 13.5.1 Test 3(b)(i), UN Manual of Tests and Criteria Part I, Section 10.3, EU Directive 2008/43/EC, ADR/RID/IMDG Code Annexes |
| Friction Stroke | 10 mm |
| Motor Drive Speed | 141 rpm |
| Load Range | 0.5–36 kg (5–360 N) via calibrated weights on 6-groove loading arm |
| Ceramic Components | Alumina ceramic rod (Ø10 × 15 mm), ceramic plate (25 × 25 × 5 mm), surface roughness Ra 9–32 µm |
| Standard Accessories | 1 cast-iron base plate, 1 loading arm with 6 grooves, 9 calibrated weights, 1 hook, 400 ceramic rods, 100 ceramic plates |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM |
| Price Range | USD 27,000 – 68,000 |
| Brand | CloudOptek |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | M1P |
| Pricing | Available Upon Request |
| Laser Wavelength | 785 nm |
| Laser Power | 1–500 mW (adjustable) |
| Laser Energy Accuracy | ±10% |
| Dose Equivalent Rate Range | 0.01–1000 µSv/h |
| Cumulative Dose Range | 0 µSv–100 Sv |
| Spectral Range | 200–1800 cm⁻¹ |
| Spectral Resolution | 8–11 cm⁻¹ |
| Alarm Threshold | 1–1000 µSv/h |
| Detection Time (e.g., ethanol) | <3 s |
| Alarm Latency | 2–4 s |
| Radiation Detection Types | α, β, γ |
| Detector Type | Scintillation Detector |
| Energy Detection Range | 25 keV–3 MeV |
| GPS Support | A-GPS, GLONASS, BeiDou |
| Connectivity | 4G, Wi-Fi, Bluetooth |
| Dimensions | 159 × 78.9 × 27 mm |
| Weight | 445 g |
| Database | Base Library, Expandable Library, User-Customizable Library (real-time sync) |
| Brand | CloudOptek |
|---|---|
| Origin | Beijing, China |
| Model | M1S |
| Laser Wavelength | 785 nm |
| Scan Modes | Lissajous scanning, single-point scanning, customizable area-matrix scanning |
| Laser Power | 1–500 mW (adjustable) |
| Spectral Range | 200–1800 cm⁻¹ |
| Spectral Resolution | 8–11 cm⁻¹ |
| Detection Time | <3 s (e.g., ethanol) |
| Connectivity | 4G, Wi-Fi, Bluetooth, NFC |
| GNSS Support | A-GPS, GLONASS, BeiDou |
| Biometric Authentication | Fingerprint + Iris recognition |
| Security Architecture | MCS cloud-network-terminal isolation framework |
| Dimensions | ~205 × 85 × 27.5 mm |
| Weight | ~500 g |
| Database | Cloud-synchronized base library (auto-updated), expandable library (instant sync), user-defined library |
| Sample Types | Solids, liquids, powders, gels, opaque or dark-colored materials |
| Brand | CloudOptek |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T1 |
| Pricing | Available Upon Request |
| Explosives Sensitivity | 1 ng |
| Fluorescence Quenching Detection | Yes |
| Raman Excitation Wavelength | 785 nm |
| Raman Spectral Range | 200–1800 cm⁻¹ |
| Raman Resolution | 8–11 cm⁻¹ |
| Radiation Detection Types | α, β, γ |
| Radiation Energy Range | 25 keV – 3 MeV |
| Energy Accuracy | ±10% |
| Dose Rate Alarm Threshold | 1 µSv/h – 1000 µSv/h |
| Detector Type | Scintillation Detector |
| Dimensions | ~270 × 118 × 62 mm |
| Weight | ~1.5 kg |
| Display | 5.7″ FHD (2560 × 1440) |
| Connectivity | 4G, Wi-Fi, Bluetooth, NFC, A-GPS, GLONASS, BeiDou |
| ID Card Reading | Supports Chinese Second-Generation Resident Identity Cards |
| Brand | GASTEC |
|---|---|
| Origin | Japan |
| Model | GASTEC Oxygen Detection Alarm (Portable) |
| Detection Principle | Electrochemical Sensor |
| Operating Range | 0–25% vol O₂ |
| Resolution | 0.1% vol |
| Accuracy | ±0.5% vol (within 15–25% range) |
| Response Time (T90) | <30 s |
| Power Supply | Rechargeable Li-ion battery (up to 2,000 hours continuous operation) |
| IP Rating | IP67 |
| Operating Temperature | −10°C to +50°C |
| Compliance | IEC 61508 SIL 2, JIS T 8201, EN 45544-1, ATEX II 2G Ex ib IIC T4 Gb |
| Brand | Knick |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Portavo 904 X |
| Pricing | Upon Request |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Koenen Test Apparatus |
| Price Range | USD 27,000 – 68,000 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | A.21/O2 |
| Pressure Measurement Range | 690–2070 kPa (0–500 psi) |
| Response Time | ≤5 ms |
| Pressure Sensor Accuracy | ±0.2 ms timing resolution |
| Ignition Wire | NiCr, 25 cm length, Ø0.6 mm, 3.85 Ω/m |
| Burst Disc | Aluminum, 0.2 mm thickness, nominal burst pressure ≈ 320 psi |
| Ignition Power Supply | 10 A / 16 V constant current |
| Data Acquisition | Digital storage oscilloscope with PC interface and printer output |
| Remote Ignition Distance | ≥2 m (separate control box) |
| Compliance | UN Manual of Tests and Criteria, Rev. 7, Test 2(c)(i).2 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Beckmann-Junk Method |
| Price Range | USD 27,000 – 68,000 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HST100 |
| Price Range | USD 27,000 – 68,000 |
| Heating Method | Electrically Heated Aluminum Block |
| Sample Capacity | 21 Positions |
| Sample Tube Dimensions | Ø30 ±0.3 mm × 230 ±2 mm (Cylindrical, Round-Bottom, Glass Stopper) |
| Temperature Range | Ambient to 110 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Sensor | PT100 Probe |
| Over-Temperature Safety Cut-off | 120 °C |
| Controller | Dedicated PID Temperature Program Controller |
| Power Supply | 230 V / 50 Hz, 2400 VA |
| Illumination System | Specialized Fluorescent Lamp (Non-Glare, Optimized for NO₂ Vapor Detection) |
| Viewing Assembly | Rigid Adjustable Lamp Mount with UV-Enhanced Visible Spectrum Output |
| Display | Dual Digital Readout (Setpoint & Actual Temperature) |
| Sample Holder Depth | 170 mm |
| Sample Holder Diameter | 31 mm |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | Methyl Violet Method |
| Temperature Range | 60–140 °C |
| Control Accuracy | ±0.1 °C |
| Sample Capacity | 24 positions (20.5 mm diameter × 280 mm depth) |
| Heating Block | Anodized aluminum with PID controller |
| Temperature Sensor | PT100 probe |
| Safety Features | Over-temperature cut-off, ISO-insulated housing |
| Power Supply | 230 V / 50 Hz, 1500 VA |
| Compliance | MIL-STD-286C (Sections 120 & 134.5), ISO 8765:2017 (Nitrocellulose stability testing) |
| Accessories | 24× cylindrical tubes (OD 20 mm, ID 17 mm, L 290 mm), vented cork stoppers, stainless steel hooks, methyl violet indicator paper (200 sheets/pack) |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AB140 |
| Price Range | USD 27,000 – 68,000 |
| Heating Block Material | Aluminum |
| Sample Capacity | 5 positions |
| Sample Tube Dimensions | Ø17.5 ± 0.1 mm × 70 mm depth (tube body) |
| Temperature Sensor | PT100 probe |
| Temperature Control | PID controller with independent control cabinet |
| Max Setpoint | 140 °C |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | 230 V / 50 Hz, 300 VA |
| Safety Features | Over-temperature cut-off protection |
| Accessories Included | 5 calibrated cylindrical sample tubes (with three annular bands), perforated rubber stoppers, platinum-tipped glass rods, KI-starch test paper support fixture |
| Brand | THT |
|---|---|
| Origin | United Kingdom |
| Model | ES-ARC |
| Compliance | ASTM E698, ISO 22517, UN Test Series 3 (H.2, H.3), IEC 60079-10-1 |
| Temperature Range | Ambient to 500 °C |
| Pressure Rating | Up to 200 bar |
| Sample Mass Capacity | 0.1–10 g |
| Heat Flow Resolution | <0.1 mW |
| Adiabatic Tracking Accuracy | ±0.02 °C/min |
| Data Acquisition Rate | 1 Hz |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ECB-2002A |
| Price | Upon Request |
| Test Vessel Temp. Range | Ambient to 200 °C |
| Max. Design Pressure | ≥2.0 MPa |
| Explosion Pressure Sensor Range | ≥5.0 MPa, Linearity: ±1.0% FS |
| Pressure Sampling Rate | ≥5 kHz |
| Data Points per Test | ≥10,000 |
| Gas Inlet Channels | 3 |
| Max. Stirring Speed | 400 rpm (adjustable) |
| Operating Environment | −5–45 °C, <95% RH |
| Gas Pressure Control Accuracy | ±0.1% FS |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP01-20S |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±1 °C |
| Uniformity in Test Zone | ±1.0 °C (≤140 °C), ±1.5 °C (140–180 °C), ±2.0 °C (180–200 °C) |
| Thermocouple Range | −40 to 1000 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Measurement Accuracy | ±1.5 °C or ≤±0.004 |
| Response Time | 0.5 s |
| Standard Timer Range | 0–240 h |
| Custom Timer Range | 0–480 h |
| Timer Accuracy | ±0.01 s |
| Timer Display Resolution | 1 s |
| Chamber Volume | ≥27 L |
| Self-Heating Test Mesh Cage Sizes | 25 mm × 25 mm × 25 mm and 100 mm × 100 mm × 100 mm |
| 75 °C Stability Vessel Dimensions | Φ(50.5 ± 0.5) mm × 150 mm |
| Interior Chamber Dimensions | 350 mm × 350 mm × 400 mm |
| Safety Valve Activation Pressure | 60 kPa |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HWP13-10S |
| Temperature Control Range | Ambient to 200°C |
| Temperature Accuracy | ±1°C |
| Uniformity | ±1.0°C (≤140°C), ±1.5°C (140–180°C), ±2.0°C (180–200°C) |
| Thermocouple Range | −40 to 1000°C |
| Temp. Resolution | 0.1°C |
| Temp. Measurement Accuracy | ±1.5°C or ≤±0.004 |
| Response Time | 0.5 s |
| Standard Timing Range | 0–240 h |
| Custom Timing Range | 0–480 h |
| Timing Accuracy | ±0.01 s |
| Timing Resolution | 1 s |
| Chamber Volume | ≥27 L |
| Sample Cage Dimensions | 25 mm and 100 mm cubes |
| Test Tube Dimensions (Φ×H) | (50.5±0.5) mm × 150 mm |
| Interior Chamber Dimensions | 350 mm × 350 mm × 400 mm |
| Safety Valve Activation Pressure | 60 kPa |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP14-10S |
| Quotation | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Temperature Measurement Range | (-40 to 1000) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1.5 °C or ≤ ±0.004 |
| Temperature Sampling Rate | 1000 Hz |
| Deflagration Distance | 50 mm |
| Deflagration Velocity Range | ≤1500 mm/s |
| Velocity Measurement Accuracy | ±0.1 mm/s |
| Time Display Resolution | ±0.1 ms |
| Detection Method | Thermocouple-based temperature monitoring |
| Dewar Vessel Internal Volume | 300 cm³ |
| Dewar Inner Diameter | 48 mm |
| Dewar Outer Diameter | 60 mm |
| Dewar Length | 200 mm |
| Dewar Cooling Half-life | ≥5 h |
| Ignition Flame Length | ≥20 mm |
| Instrument Dimensions (L×W×H) | 830 mm × 400 mm × 600 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP17-10S |
| Operating Temperature | (-5–45) °C |
| Relative Humidity | <95% RH |
| Motor Speed | 140 ± 3 rpm (at maximum load) |
| Load Range | 1–2–5–10–20–40–60–80–120–160–240–360 N |
| Load Accuracy | ±0.038 N (1 N), ±0.048 N (2 N), ±0.08 N (5 N), ±0.21 N (10 N), ±0.45 N (20 N), ±0.49 N (40 N), ±0.22 N (60 N), ±0.27 N (80 N), ±0.32 N (120 N), ±0.37 N (160 N), ±0.43 N (240 N), ±0.48 N (360 N) |
| Sieve Mesh | 35 mesh (optional) |
| Alumina Ceramic Surface Roughness | 9–32 µm |
| Center-to-Center Distance (Weight–Ceramic Rod) | 11, 16, 21, 26, 31, 36 cm |
| Ceramic Plate Stroke | 10 mm |
| Ceramic Plate Dimensions (L×W×H) | 25 × 25 × 5 mm |
| Ceramic Rod Dimensions (Φ×L) | 10 × 15 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HWP18-30S |
| Quotation | Upon Request |
| Operating Environment | (-5–45) °C, <95% RH |
| Impact Masses | 0.5 kg ±0.1%, 1 kg ±0.1%, 2 kg ±0.1%, 5 kg ±0.1%, 10 kg ±0.1% |
| Drop Height Range | 0–1000 mm |
| Positioning Accuracy | ±1 mm |
| Guide Rail Verticality | ≤0.1 mm/m |
| Hammer Coaxiality | ≤φ0.15 mm |
| Instrument Planarity Deviation | ≤0.012 mm |
| Impact Energy Range | 0.5–100 J |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP20-10S |
| Pricing | Available Upon Request |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HWP21-30S |
| Temperature Control Range | −10 °C to 210 °C |
| Temperature Accuracy | ±1 °C |
| Sample Temperature Measurement Range | −50 °C to 350 °C |
| Sample Temperature Resolution | 0.1 °C |
| Sample Temperature Accuracy | ≤ ±(0.15 + 0.002 |
| Gas Mixing Pressure Range | 0–110 kPa |
| Pressure Accuracy | ±0.1% FS |
| Vacuum Capability | ≤1.33 kPa |
| Leak Rate | ≤0.03 kPa/min |
| Ignition Spark Gap | 6.4 mm |
| Ignition Voltage/Current | 15 kV / 30 mA |
| Ignition Duration | 0–1 s |
| Test Vessel Options | 5 L (Ø222 mm × H345 mm) or 12 L (Ø295 mm × H378 mm) borosilicate glass |
| Stirring Speed | ≥300 rpm |
| Environmental Monitoring | Ambient Temp (−10–60 °C, ±0.5 °C), RH (5–95% RH, ±5.0% RH), Atmospheric Pressure (60–110 kPa, ±0.5 kPa) |
| Timing Range | 0–24 h |
| Timing Accuracy | ±0.01 s |
| IP Rating | IP65 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HWP27-10S |
| Price | Upon Request |
| Operating Environment | (-5–45)°C, <95% RH |
| Chamber Temperature Range | -20°C to 220°C |
| Temperature Control Accuracy | ±1°C |
| Sample Temperature Measurement Range | -50°C to 500°C |
| Sample Temperature Resolution | 0.1°C |
| Sample Temperature Accuracy | ±(2.5 or 0.0075× |
| Dewar Volume | 1 L |
| Constant Power Regulation Range | 0.1 W–2 W |
| Constant Power Accuracy | ≤0.015 W |
| Temperature Rise Rate Range | 0–2°C/min |
| Refrigerant Circulation Flow Rate | ≥3 L/min |
| Dewar Liner Material | Borosilicate Glass |
| Dimensions (L×W×H) | 930 mm × 545 mm × 875 mm |