Dielectric Constant Meter
Filter
Showing 1–30 of 111 results
| Brand | ABTEC |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A5 |
| Pricing | Available Upon Request |
| THD+N (Typical) | –108 dB |
| Max Input Voltage (Balanced) | 300 Vrms |
| Analog Output Amplitude | 21 Vrms |
| Supported Bluetooth Codecs | SBC, aptX, aptX-LL, aptX-HD, AAC, LHDC (HWA) |
| Digital Interface Options | SPDIF, TOSLINK, AES/EBU, I²S, HDMI, BT, PDM (optional), DSI-O (optional, higher sample rate support) |
| Software API Support | VB.NET, C#.NET, LabVIEW |
| Measurement Capabilities | Level/Gain/Phase, Channel Balance, Frequency Response, THD+N, IMD, SNR, Noise, Crosstalk, Interchannel Phase, DC Level, Frequency Measurement, CMRR, Oscilloscope & Spectrum Monitoring, Stepped Level/Frequency Sweep, DC Level Sweep, Q-Peak Noise |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ZJD-87 Dielectric Constant and Dissipation Factor Analyzer |
| Price Range | USD 11,200 – 21,000 (FOB Beijing) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZJD-87 |
| Price Range | USD 7,000 – 14,000 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJD-A Dielectric Constant and Dissipation Factor Analyzer |
| Frequency Range | 10 kHz – 60 MHz (DDS Synthesized) |
| Capacitance Tuning Range | 30–500 pF |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Accuracy | < ±5% |
| Inductance Measurement Range | 15 nH – 8.4 H |
| Inductance Resolution | 0.1 nH |
| Inductance Accuracy | < ±5% |
| Frequency Accuracy | ±3×10⁻⁵ ±1 digit (6-digit display) |
| Frequency Coverage Ratio | 6000:1 |
| Standard Compliance | GB/T 1409, IEC 60250, JB 7770 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model | ZJD-A Dielectric Constant and Impedance Analyzer |
| Frequency Range | 10 kHz – 70 MHz (DDS Synthesized) |
| Q Factor Range | 1–1000 (Auto/Manual Scaling) |
| Q Resolution | 0.1 (4-digit display) |
| Frequency Accuracy | ±3×10⁻⁵ ±1 digit (6-digit precision) |
| Inductance Measurement Range | 15 nH – 8.4 H |
| Capacitance Tuning Range | 30–500 pF |
| Capacitance Resolution & Error | ±1.5 pF or <1% |
| tanδ Measurement Capability | Yes |
| εᵣ (Relative Permittivity) Calculation | Supported via parallel-plate fixture |
| Fixture Electrode Diameter | Φ50 mm / Φ38 mm (selectable) |
| Electrode Spacing Adjustment | ≥15 mm |
| Micrometer Resolution | 0.001 mm |
| Fixture Loss Tangent (1 MHz) | ≤4×10⁻⁴ |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJD-A |
| Frequency Range | 10 kHz – 110 MHz |
| Q Measurement Range | 1–1000 |
| Tanδ Accuracy | 1×10⁻⁴ |
| εr Accuracy | 0.001 |
| Electrode Diameter | Φ38 mm or Φ50 mm (selectable) |
| Electrode Spacing Adjustment | ≥15 mm |
| Sample Thickness Range | 0.1–10 mm |
| Residual tanδ of Fixture | ≤4×10⁻⁴ @ 1 MHz |
| Power Supply | 220 V ±10%, 50 Hz ±2.5 Hz |
| Operating Temperature | 0–40 °C |
| Power Consumption | ~25 W |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150–11, IEC 60250 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZJD-B |
| Price Range | USD 4,200 – 11,200 (FOB Beijing) |
| Frequency Range | 1 kHz – 1 GHz (standard) |
| Dielectric Constant (ε′) Range | 1.0 – 35.0 (resolution: 0.1%) |
| Loss Tangent (tan δ) Range | 1×10⁻⁵ – 1.0 (resolution: 1×10⁻⁵) |
| Sample Compatibility | Solid discs (Ø20–100 mm, thickness 0.1–10 mm), liquids (parallel-plate or coaxial probe), thin films (3-electrode configuration) |
| Temperature Range | Ambient (23 °C ±1 °C) |
| optional thermal chamber | −50 °C to +150 °C |
| Voltage Gradient | 10–500 V/mm (adjustable per sample thickness) |
| Compliance | IEC 60250:2020, ASTM D150-18, GB/T 1409-2006 |
| Calibration | Open/short/load with NIST-traceable polystyrene reference dielectric and certified standard capacitors |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJD-C |
| Frequency Range | 50 Hz – 1 MHz |
| Test Voltage | 0.1 kV – 10 kV |
| Temperature Control | Ambient to 300 °C |
| Sample Compatibility | Solid discs (Ø25–100 mm, thickness 0.1–10 mm), liquids, thin films |
| Measurement Accuracy | ε ≤ ±1%, tanδ ≤ ±1×10⁻⁴ |
| Compliance | IEC 60250, ASTM D150, GB/T 1409, IEEE 286 |
| Calibration | CNAS-accredited traceability |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJD-C |
| Frequency Range | 100 kHz – 160 MHz |
| Q Factor Range | 1–1023 |
| Capacitance Measurement | 1 pF – 25 nF |
| Inductance Measurement | 1 nH – 140 mH |
| Main Tuning Capacitor Range | 17–240 pF |
| Accuracy | ±1 pF (≤150 pF), ±1% (>150 pF) |
| Signal Source | DDS Synthesized, Stability ±3×10⁻⁵ ±1 digit |
| Power Supply | 220 V ±10%, 50 Hz ±2.5 Hz |
| Power Consumption | ~25 W |
| Operating Temperature | 0–40 °C |
| S916 Dielectric Test Fixture | Parallel-plate Electrodes (Φ38 mm), Gap Adjustment ≥15 mm, Resolution 0.001 mm, tanδ ≤4×10⁻⁴ @ 1 MHz |
| LKI-1 Inductor Set | 10 Standard Inductors (0.05 μH to 10 mH) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (adjustable) |
| Accuracy | ±1% |
| Display | Digital LCD |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | 4.5 kg |
| Compliance | GB/T 1410–2006, ASTM D257–99, GB/T 10581–2006, GB/T 1692–2008, GB/T 2439–2001, GB/T 12703.4–2010, GB/T 10064–2006 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | DC 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (±10%) |
| Accuracy | ±1% (up to 10¹⁰ Ω), ±5% + 2 digits (10¹¹–10¹³ Ω), ±10–15% + 5 digits (>10¹⁴ Ω) |
| Display | Full-digit LCD, simultaneous resistance and current readout |
| Dimensions | 300 mm × 280 mm × 150 mm |
| Weight | ~3.0 kg |
| Power | AC 220 V, 50 Hz, ~10 W |
| Operating Environment | –10 °C to 50 °C, RH < 90% |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (selectable) |
| Display | Digital LCD |
| Accuracy | ±1% |
| Compliance | GB/T 1410–2006, ASTM D257–99, GB/T 10581–2006, GB/T 1692–2008, GB/T 2439–2001, GB/T 12703.4–2010, GB/T 10064–2006, GB/T 22042–2008, EN 1149-1:1995, FZ/T 64013–2008, SJ/T 10694–2006 |
| Brand | AET |
|---|---|
| Origin | Japan |
| Model | Coaxial Resonant Cavity System |
| Frequency Range | 800 MHz – 9.4 GHz |
| Permittivity (ε′) | 1–15 |
| Accuracy | ±1% |
| Loss Tangent (tan δ) | 0.001–0.1 |
| Accuracy | ±5% |
| Resonant Modes | Type A (0.8 / 2.45 / 4.2 / 5.8 / 7.6 GHz) and Type B (1.0 / 3.1 / 5.2 / 7.3 / 9.4 GHz) |
| Measurement Principle | High-Q coaxial cavity resonance with 3D electromagnetic field simulation (CST Microwave Studio®) |
| Brand | AET |
|---|---|
| Origin | Japan |
| Model | Liquid Resonant Cavity System |
| Frequency Range | 1–10 GHz |
| Permittivity Range | 1–6 |
| Permittivity Accuracy | ±1% |
| Loss Tangent Range | 0.001–0.01 |
| Loss Tangent Accuracy | ±5% |
| Minimum Sample Diameter | >5.5 mm |
| Brand | AET |
|---|---|
| Origin | Japan |
| Model | Powder Resonant Cavity System |
| Frequency Range | 1–10 GHz |
| Permittivity Range | ε′ = 1–6 |
| Permittivity Accuracy | ±1% |
| Loss Tangent Range | tan δ = 0.001–0.01 |
| Loss Tangent Accuracy | ±5% |
| Minimum Sample Diameter | ≥5.5 mm |
| Sample Form | Powders (quartz tube loaded) and Low-Polarity Liquids |
| Brand | AET |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | TE Cavity Resonator |
| Price Range | USD 42,000 – 140,000 |
| Frequency Range | 10–40 GHz |
| Permittivity (εᵣ) | 1–5 |
| Accuracy | ±1% |
| Loss Tangent (tan δ) | 0.0001–0.01 |
| Accuracy | ±5% |
| Sample Thickness | 0.01–0.3 mm |
| Minimum Sample Size | 50×50 mm (at 10 GHz), 40×40 mm (at 20 GHz), 30×30 mm (at 28/40 GHz) |
| Compliance | JIS R1641, IPC-TM-650 2.5.5.13 |
| Measurement Geometry | In-plane (parallel to film surface) |
| Cavity Type | Split-cylinder TE-mode resonant cavity |
| Brand | AET |
|---|---|
| Origin | Japan |
| Model | TM010/TM011 Cavity Resonator |
| Frequency Range | 1–10 GHz |
| Permittivity (ε′) | 1–30 |
| Accuracy | ±1% |
| Loss Tangent (tan δ) | 0.0001–0.05 |
| Accuracy | ±5% |
| Compliance | JIS C2565, ASTM D2520 |
| Sample Form | Rectangular bar (non-destructive) |
| Q-Factor | High (>10,000 typical) |
| Cavity Customization | Frequency-specific cavity modules available |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDA-A |
| Price | USD 2,500 (approx.) |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BI-870 |
| Measurement Range | 1–20 and 1–200 |
| Accuracy | ±2% |
| Repeatability & Linearity | ±0.2% |
| Max Sample Conductivity | 1 µS/cm (for range 1–20), 10 µS/cm (for range 1–200) |
| Minimum Sample Volume | 25 mL |
| Probe Material | Stainless Steel & PTFE |
| Excitation Signal | Low-distortion 10 kHz sine wave (7 Vrms for 1–20 range |
| Display | LCD |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method |
| Frequency Range | 10 kHz – 100 MHz |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit) |
| Q Accuracy | <5% |
| Inductance Range | 1 nH – 140 mH (0.1 nH resolution) |
| Capacitance Range | 1 pF – 25 nF (0.1 pF resolution) |
| Main Tuning Capacitor | 17–240 pF (silver-plated, ±1 pF or <1% error) |
| Signal Source Stability | 3×10⁻⁵ ±1 digit |
| ADC Resolution | 12-bit |
| Auto-Null Compensation | Residual inductance & lead inductance |
| Display | LCD with real-time F, L, C, Q, Lₜ, Cₜ, εᵣ, tan δ |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Q-Factor Based) |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Capacitance Range (Tuning) | 17–240 pF |
| Capacitance Direct Measurement | 1 pF – 25 nF |
| Capacitance Accuracy | ±1 pF or <1% |
| Capacitance Resolution | 0.1 pF |
| AD Sampling | 12-bit |
| Automatic Residual Inductance Compensation | Yes |
| Motorized Capacitor Tuning | Yes |
| Display | LCD with Real-Time Parameters (F, L, C, Q, Lt, Ct, εᵣ, Tn) |
| Brand | DAZHAN (Nanjing Dazhan Instrument Co., Ltd.) |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Q-factor based) |
| Frequency Range | 10 kHz – 100 MHz (DDS Digital Synthesis, 7000:1 coverage ratio) |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 (auto/manual range, 4-digit resolution, 0.1 Q step) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH (0.1 nH resolution, <3% error) |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF (±1 pF or <1% error, 0.1 pF resolution) |
| Automatic Capacitance Search | Stepper-motor-driven |
| Residual & Lead Inductance Compensation | Yes (automated subtraction) |
| Display | LCD showing F, L, C, Q, Lₜ, Cₜ, εᵣ, Tₙ, etc. |
| AD Sampling | 12-bit high-precision ADC |
| Q Pre-set Pass/Fail Threshold | 5–1000 with audible/visual alert |
| Operating Mode | Auto-resonance sweep or manual tuning |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Parallel-Plate Capacitor Configuration) |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Error | ±1 pF or <1% |
| Automatic Capacitance Search | Yes (stepper motor-driven) |
| Residual & Lead Inductance Compensation | Yes |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, tanδ, Tn |
| Compliance | GB/T 1693–2007, ASTM D150, GB 9622.9–1988 / SJ/T 11043–1996 |
| Brand | DAZHAN (Nanjing Dazhan Instrument Co., Ltd.) |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Q-factor-based) |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Direct Capacitance Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Accuracy | ±1 pF or <1% |
| Automatic Capacitance Search | Yes (stepper motor-driven) |
| Residual Inductance Compensation | Yes |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, tanδ |
| Compliance | GB/T 1409–2006, GB/T 1693–2007 |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Tuning Capacitance | 17–240 pF (silver-plated monolithic) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Accuracy | ±1 pF or <1% |
| Capacitance Resolution | 0.1 pF |
| Auto Capacitance Search | Yes (stepper motor driven) |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, etc. |
| Residual Inductance Compensation | Yes |
| Data Interface | RS-232/USB for PC connectivity |
| Compliance | Designed per IEC 60250 and ASTM D150 guidelines for dielectric property measurement |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Capacitance Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Error | ±1 pF or <1% |
| Automatic Residual Inductance Compensation | Yes |
| Auto-Resonance Search | Yes (stepper motor–driven) |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, etc. |
| Compliance | Designed for ASTM D150, IEC 60250, GB/T 1409, and ISO 18732-compliant dielectric characterization workflows |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-D4 |
| Price | USD 2,600 (FOB Beijing) |
| Frequency Range | 20 Hz – 2 MHz (10 mHz resolution) |
| Test Signal Level | 10 mV – 5 Vrms (1 mV step) |
| Basic Accuracy | ±0.1% |
| Measurement Speed | Up to 200 readings/sec |
| Display | 320×240 dot-matrix graphical LCD |
| Resolution | 5-digit |
| Impedance Parameters | 22 configurable combinations (e.g., C–D, C–Q, L–Q, R–X, Z–θ) |
| Electrode Options | Fixed parallel-plate electrodes (Ø38 mm / Ø50 mm standard), liquid cell (15 mL capacity), powder-specific electrode kits |
| Sample Forms | Solid sheets, films, pellets, liquids, pastes, powders, irregular geometries |
| Test Methods | Contact (for flat, uniform-thickness specimens) and Non-contact (capacitive coupling for rough or curved surfaces) |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150–18, IEC 60250:2015 |
| DC Bias | Internal ±10 V / 100 mA |
| ALA/ALC | Automatic Level Control with V/I monitoring |
| Scan Modes | 10-point frequency, voltage, or bias list sweep |
| Data Storage | 20 instrument setups |
| Interface | USB Host/Device, RS232, GPIB (optional), LAN (optional) |
| Firmware Update | Via USB flash drive |
| Language | English / Chinese switchable |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCWP-A |
| Electrode Diameter | 6 mm (4 electrodes) |
| Electrode Shielding | Inner layer – 304 stainless steel |
| Channel Configuration | Quad-channel simultaneous measurement |
| Frequency Switching | Programmable sample switching interval |
| Operating Modes | Manual and automated sequence control |
| Data Export | Raw data export (CSV/Excel), real-time curve plotting, printable test reports |
| Frequency Range | Determined by integrated Agilent 4294A Precision Impedance Analyzer |
| Temperature Range | −180 °C to +500 °C |
| Heating Rate | 0.5–2.5 °C/min (programmable) |
| Cryogenic Cabling | Silver-plated copper shielded cables |
| Enclosure | Q235 carbon steel chassis with high-temp epoxy powder coating |
| Power Supply | AC 220 V, 50 Hz, 2 kW |
| Core Impedance Analyzer | Agilent 4294A |
| Environmental Requirements | Avoid dusty, high-vibration, direct sunlight, or corrosive gas environments |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | GCSTD-A/B |
| Price | USD 1,400 (approx.) |
| Measurement Principle | Resonant Frequency Method (Q-meter based) |
| Frequency Range | Selectable across three variants (A/B/C — model-specific bands, typically 1 MHz to 100 MHz) |
| Sample Types | Solid, Liquid, Powder |
| Electrode Diameter | 38 mm (standard) |
| Solid Sample Thickness Range | 0.5–15 mm |
| Liquid Cell Dimensions | ID 48 mm × Depth 7 mm (optional) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <80% RH |
| Power Supply | 220 V ±10%, 50 Hz ±2.5 Hz |
| Power Consumption | ~25 W |
| Net Weight | ~7 kg |
| Dimensions (L×W×H) | 380 × 280 × 132 mm |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSTD-AB3 |
| Price | USD 270 (FOB) |
| Test Frequency Range | 10 kHz – 10 MHz (typical for AB3 variant) |
| Measurement Principle | High-Frequency Resonance Method (Q-meter based) |
| Display | Digital LCD with Auto-Resonance Search & Frequency Locking |
| Supported Sample Forms | Solid, Liquid, Powder |
| Standard Electrode Diameter | Φ38 mm |
| Solid Sample Thickness Range | 0.5–15 mm |
| Liquid Cell Dimensions | Φ48 mm ID × 7 mm depth (optional) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <80% RH |
| Power Supply | 220 V ±10%, 50 Hz ±2.5 Hz |
| Power Consumption | ~25 W |
| Net Weight | ~7 kg |