| Brand | Ailun |
|---|---|
| Model | AL-200 |
| Type | Portable Activity Meter (Radionuclide Concentration Analyzer) |
| Detector | Scintillation Crystal (NaI:Tl) |
| Power Supply | AC 100–240 V (with adapter) or 2×AA batteries |
| Display | Backlit LCD with real-time activity readout (Bq/kg or Bq/L) |
| Data Storage | Up to 200 measurement records |
| Radiation Indication | Tri-color LED status indicator (green/yellow/red) |
| Sample Forms | Liquids (water, beverages) and solids (food, soil, filters) |
| Shielding | Integrated lead-lined metal housing |
| Connectivity | Optional USB interface for PC-based control and data export |
| Compliance | Designed per IEC 60846-1:2014 (radiation protection instrumentation – ambient and/or directional dose equivalent rate meters) |
| Weight | <1.8 kg |
| Dimensions | 220 × 110 × 75 mm |
| Brand | Ailun (Qingdao Ailun) |
|---|---|
| Origin | Shandong, China |
| Model | AL-FS6100 |
| Instrument Type | Laboratory-Based Activity Meter |
| Channel Configurations | 2 / 4 / 6 / 8 Independent Channels |
| Compliance | GB 5749–2006, GB/T 5750.13–2006, GB 8537–2008, HJ 898–2017, HJ 899–2017 |
| Control Interface | USB 2.0 (Driver-Free), Windows-Compatible Multi-Document Application |
| Detector Type | Planar Passivated Implanted Planar Silicon (PIPS) with Enhanced Geometry |
| High-Voltage Supply | Low-Ripple Linear DC HV Regulator (<10 µA Static Current) |
| Display | 320×240 TFT Color LCD on Controller Unit |
| Enclosure | 19″ Rack-Mountable Shielded Cabinet with Interlocked Lead-Lined Access Door |
| Core Electronics | CPLD-Based Digital Pulse Processing Architecture |
| PCB Design | Multi-Layer High-Density Layout for EMI Suppression and Signal Integrity |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SmartChem 200 |
| Price | €60,000 |
| Power Requirement | 90–250 VAC, 47–63 Hz, 300 W |
| Water Consumption | 2 mL per test |
| Operating Temperature | 18–30 °C |
| Relative Humidity | 20–85 % RH |
| Dimensions (H×W×D) | 42 × 65 × 100 cm |
| Weight | 65 kg |
| Sample Capacity | 126 positions across 5 racks |
| Sample Tube Size | up to 16 mm × 100 mm |
| Minimum Sample Volume | 3.0 µL (1 µL increment) |
| Reagent Volume | 3.0–300 µL (1 µL increment) |
| Dilution Factor | up to 100× |
| Reaction Cuvettes | 60-position rotating reusable disc, temperature-controlled at 37.0 ± 0.1 °C |
| Optical System | Dual-beam photometer with 8 narrow-band interference filters (420–880 nm), 6 V/10 W halogen lamp, 10 mm pathlength, linear range 0.001–2.500 Abs, resolution 0.0001 Abs |
| Throughput | up to 200 tests/hour |
| Detection Principle | Direct spectrophotometric measurement in discrete reaction cuvettes |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | 31-040A |
| Price | Upon Request |
| Detection Radiation | X-ray & Gamma (γ) |
| Dose Rate Range | 0.01 µSv/h – 10 mSv/h |
| Cumulative Dose Range | 0.1 pSv – 1 Sv |
| Energy Response Range | 30 keV – 3 MeV |
| Dose Rate Accuracy | ±30% (typical, per IEC 61526 ed.3) |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Input | DC 5 V / 200 mA |
| Ingress Protection | IP65 |
| Battery Life | >72 h (background radiation environment, no external power) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | 32-150B |
| Price | Upon Request |
| Detection Radiation | X-ray and γ-ray |
| Dose Rate Range | 0.01 µSv/h to 10 mSv/h |
| Cumulative Dose Range | 0.1 µSv to 1 Sv |
| Energy Response Range | 30 keV to 3 MeV |
| Dose Rate Accuracy | < ±30% |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | < 90% (non-condensing) |
| Power Input | DC 5 V |
| Dimensions | 110 mm × 135 mm × 47 mm |
| Weight | < 500 g |
| Display | Large-color high-brightness LED |
| Alarm | Audible and visual alarm with user-adjustable threshold |
| Mounting | Wall-mountable or benchtop placement |
| Connectivity | Ethernet port, USB interface, optional Wi-Fi antenna |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ChiRad 160C |
| Price | Upon Request |
| X-ray Energy Range | 40–160 kV |
| Tube Current | 10 mA |
| System Power | 800 W (configurable) |
| Focal Spot Size | 1.2 mm |
| Beam Coverage Diameter | 40 cm |
| Source-to-Object Distance | 13–55 cm |
| Exposure Time | 1–180 min |
| Input Power | 220 VAC ±10%, 50/60 Hz, Single-phase, 9 kVA |
| Cooling | Integrated Closed-loop Heat Exchanger |
| Sample Turntable | Motorized, 2 RPM |
| Internal Chamber Dimensions | 335 × 375 × 395 mm (W×D×H) |
| External Dimensions | 730 × 560 × 1300 mm (W×D×H) |
| Weight | 660 kg |
| Leakage Dose | <0.5 µSv/hr at 10 cm from surface (max energy operation) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | ChiRad 4000 |
| Price | Upon Request |
| Maximum Tube Voltage | 75 kV (adjustable) |
| Focal Spot Size | 7.5 mm |
| Max Tube Current | 50 mA (adjustable) |
| System Power | 4000 W (adjustable) |
| Radiation Cone Angle | 40° |
| Max Irradiation Field Diameter (on Rotating Platform) | 30 cm |
| Source-to-Sample Distance (SSD) | 5–50 cm (adjustable) |
| Single Exposure Duration | 1–60,000 s (adjustable) |
| Dose Rate | Up to 600 Gy/min |
| Irradiation Chamber Dimensions (W×H×D) | 45 × 50 × 40 cm |
| Overall Enclosure Dimensions (H×W×D) | ~182 × 110 × 88 cm |
| Cooling System | Industrial Air-Cooling + Compressor-Based Water Chiller |
| Shielding | Lead-lined Enclosure |
| Uniformity | ≥95% (with Motorized Turntable & Beam Filtration) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ChiRad225 Pro |
| Pricing | Upon Request |
| Maximum Tube Voltage | 225 kV |
| Tube Current | 20 mA |
| System Power | 4.5 kW |
| Focal Spot Size (EN) | 5.5 mm |
| Inherent Filtration | 2 mm Be |
| Radiation Beam Angle | 40° |
| Effective Irradiation Field Diameter | 40–50 cm |
| Source-to-Object Distance Range | 13–80 cm |
| Exposure Time Range | 1 s to 9999 h |
| Input Power | 220 VAC ±10%, 50/60 Hz, Single-phase, 9 kVA |
| Cooling System | Integrated Closed-loop Heat Exchanger |
| Sample Stage | Motorized Vertical Lift & Rotation (2 RPM) |
| Internal Chamber Dimensions | 75 cm (H) × 55 cm (W) × 55 cm (D) |
| Leakage Dose | <0.5 µSv/h at 10 cm from surface (at max output) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HENT33-051A |
| Instrument Type | Dose Rate Meter |
| Radiation Type | Gamma Rays |
| Energy Range | 59 keV – 1.33 MeV |
| Dose Rate Range | 0.1 µSv/h – 100 µSv/h |
| Count Rate Range | 10 cps – 100,000 cps |
| Azimuth Accuracy | ±10° (horizontal), ±20° (vertical) |
| Azimuth Coverage | 0°–360° (horizontal), −45° to +90° (vertical) |
| Source Localization Time | ≤30 s for 10 µCi ¹³⁷Cs at 1 m |
| Isotope Identification | 20 common radionuclides |
| Power Supply | Internal rechargeable battery (12 V DC external input supported) |
| Battery Life | 5 hours |
| IP Rating | IP54 (dust and rain resistant) |
| Operating Temperature | −20 °C to +60 °C |
| Brand | Aolong |
|---|---|
| Model | HENT31-022A |
| Type | Portable Radiation Dose Rate & Accumulated Dose Monitor |
| Detector | Scintillation-based (Energy-Compensated) |
| Measured Radiation | X-ray and Gamma (γ) Radiation |
| Dose Rate Range | 0.01 µSv/h to 10 mSv/h |
| Energy Response Range | 30 keV to 3 MeV |
| Accuracy | < ±15% (Dose Rate) |
| IP Rating | IP65 |
| Operating Temperature | −10 °C to +50 °C |
| Power Supply | 2 × AA batteries |
| Display | Real-time Dose Rate & Cumulative Dose |
| Alert Modes | Audible Tones (Frequency-Modulated), Visual LED (Color + Flash Rate), Vibration |
| Compliance | Designed for IEC 60846-1:2014 (Radiation Protection Instrumentation — Ambient and/or Directional Dose Equivalent (Rate) Meters and/or Monitors for Photons), Supports GLP/GMP-relevant operational traceability |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APOGEE |
| Pricing | Available Upon Request |
| Wavelength Range | 350–1000 nm (PAR-NIR) / 300–850 nm (UV-PAR) |
| Dimensions | 15.5 × 9.5 × 4 cm (PAR-NIR), 15.5 × 11 × 8 cm (UV-PAR) |
| Weight | 500 g (PAR-NIR), 900 g (UV-PAR) |
| Detector | 2048-pixel linear CCD array (14 × 200 µm) |
| Spectral Resolution | 0.5 nm |
| Wavelength Repeatability | < 0.05 nm |
| Thermal Wavelength Drift | < 0.001 nm/°C |
| Integration Time | 4–6500 ms |
| Exposure Time | 4 µs–60 s |
| Dynamic Range | 1–4096 counts (±0.5%) |
| Signal-to-Noise Ratio | 1000:1 |
| Linearity Range | 0–2.1 AU (<0.5% deviation) |
| Power Input | +5 VDC, 220–250 mA |
| Optical Fiber Cable | 2 m, SMA-terminated |
| Cosine Corrector | Integrated, NIST-traceable calibration |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ASM IV Series |
| Instrument Type | Portable Dose Rate Meter |
| Measurement Target | Nuclear Radiation |
| Detector Type | Plastic Scintillator |
| Application Scope | Radiological Contamination Incidents |
| Sensitivity | High |
| Brand | AST / ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | DM5200 |
| Instrument Type | Radiation Dose Rate Meter |
| Measurement Range | 0.01–200 µSv/h |
| Energy Response | 0.048–3.00 MeV (≤±20% relative to ¹³⁷Cs) |
| Basic Relative Error | ≤±10% |
| Repeatability | ≤5% RSD per single measurement |
| Accuracy (95% confidence, 15 s integration) | ≤±10% |
| Alarm Thresholds | 0.25, 2.5, 10, 20 µSv/h (user-selectable) |
| Integration Time | 1–60 s (adjustable in 1 s increments) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Power Supply | Two 1.5 V D-cell batteries |
| Power Consumption | ≤150 mW |
| Dimensions | 330 × 230 × 90 mm |
| Weight | 1.5 kg |
| Detector | NaI(Tl) scintillation crystal |
| Display | Dot-matrix LCD with Chinese UI |
| Interface | Touch-sensitive keypad |
| Units | µSv/h (default), selectable µR/h |
| Battery Monitoring | Real-time voltage monitoring with low-battery alert |
| Brand | ATOMTEX |
|---|---|
| Model | AT1103M |
| Type | Portable Dose Rate Meter |
| Detector | Be-window NaI(Tl) Scintillator (Ø9×2 mm) |
| Measured Quantity | Ambient Dose Equivalent Rate H′(0.07) |
| Measurement Range | 50 nSv/h – 100 µSv/h |
| Energy Range | 5–160 keV |
| Energy Response | ±35% (5–60 keV), ±30% (60–160 keV) |
| Accuracy | ±15% (full range), ±5% (calibration sources: ⁵⁵Fe, ²⁴¹Am, ¹⁰⁹Cd, ⁵⁷Co) |
| Operating Temperature | 0–+40 °C |
| Relative Humidity | ≤90% at +35 °C |
| IP Rating | IP54 |
| Weight | 0.8 kg |
| Dimensions | 233×85×67 mm |
| Power | Rechargeable Ni-MH battery (6 V), AC 220 V / 50 Hz, DC 12 V |
| Battery Life | ≥24 h |
| Data Storage | 100 measurement records + 256-channel MCA spectrum storage |
| Compliance | IEC 60846, CISPR 22:1997, IEC 61000-4-2:1995, IEC 61000-4-3:1995 |
| Brand | ATOMTEX |
|---|---|
| Origin | Belarus |
| Model | AT1121 |
| Detection Principle | Scintillation (plastic scintillator with heavy metal admixture) |
| Measuring Quantity | Ambient Dose Equivalent H*(10) |
| Continuous Dose Rate Range | 50 nSv/h – 10 Sv/h |
| Short-Term Dose Rate Range | 5 µSv/h – 10 Sv/h |
| Pulse Dose Rate Capability | Down to 10 ns (for AT1123 variant |
| Energy Range | 15 keV – 10 MeV |
| β Detection | Yes (with optional collimator/filter cap) |
| Display | Backlit LCD |
| Data Storage | 100 measurements |
| Interface | RS-232, 300–19200 baud |
| Operating Temperature | −30 °C to +40 °C |
| IP Rating | IP54 |
| Weight | 0.9 kg |
| Dimensions | 233 × 85 × 67 mm |
| Power | Rechargeable 6 V battery / AC 220 V / DC 12 V |
| Compliance | IEC 61000-4-2:1995, IEC 61000-4-3:1995, CISPR 22:1997 |
| Brand | ATOMTEX |
|---|---|
| Origin | Belarus |
| Model | AT1121 |
| Detection Principle | Scintillation (Plastic Scintillator with Heavy Metal Mixture, 30 × 15 mm) |
| Measured Quantity | Ambient Dose Equivalent H*(10) |
| Continuous Dose Rate Range | 50 nSv/h – 10 Sv/h |
| Short-Term Dose Rate Range | 5 µSv/h – 10 Sv/h |
| Pulse Dose Rate Capability | Down to 10 ns (for AT1123/AT1123A variants only) |
| Energy Range | 15 keV – 10 MeV |
| β Detection Capability | Yes |
| Operating Temperature | −30 °C to +40 °C |
| IP Rating | IP54 |
| Weight | 0.9 kg |
| Dimensions | 233 × 85 × 67 mm |
| Power Supply | Rechargeable 6 V battery (≥12 h), AC 220 V, or DC 12 V |
| Data Interface | RS-232, 300–19200 baud |
| Memory Capacity | 100 measurement records |
| Display | Backlit LCD |
| Alarm | Audible and visual threshold alerts |
| Brand | Atomtex |
|---|---|
| Model | AT1320 |
| Detector Type | Scintillation-based Gamma Spectrometer |
| Detector Crystal | NaI(Tl), Ø63×63 mm |
| Activity Range (¹³⁷Cs) | 3.7–1,000,000 Bq/kg (or Bq/L) |
| Activity Range (⁴⁰K) | 50–20,000 Bq/kg |
| Activity Range (²²⁶Ra & ²³²Th) | 10–10,000 Bq/kg |
| Energy Range | 50–3000 keV |
| Energy Resolution (¹³⁷Cs, 662 keV) | 7.0–8.5 % FWHM |
| Intrinsic Nonlinearity | ≤1 % |
| Relative Uncertainty in Specific Activity Measurement | ≤±20 % |
| Minimum Detectable Activity (¹³⁷Cs in 1 L Marinelli beaker, 3 h, P=0.95) | 3.0 Bq/L |
| Sample Density Range | 0.1–3.0 g/cm³ |
| Operating Temperature | 0–40 °C |
| Power Supply | 220 V ±10 %, 50 Hz ±2 Hz |
| Power Consumption | ≤8 VA |
| Continuous Operation Time | ≤24 h |
| 24-h Drift | ≤3 % |
| Dimensions (Detector) | 97×405 mm, 3.0 kg |
| Dimensions (Processing Unit) | 200×109×35 mm, 0.62 kg |
| Shielding Assembly | Ø600×700 mm, 110 kg |
| AC Adapter | 92×62×52 mm, 0.8 kg |
| EMC Compliance | IEC/EN 61000-4-2:1995, IEC/EN 61000-4-3:1995, IEC/EN 61000-4-4:1995, IEC/EN 61000-4-11:1994, CISPR 22:1997 |
| Brand | Atomtex |
|---|---|
| Model | AT2140 / AT2140A |
| Type | Personal Dose Rate & Dose Meter (γ-ray) |
| Dose Rate Range (AT2140) | 0.01 μSv/h – 10 mSv/h |
| Dose Rate Range (AT2140A) | 0.01 μSv/h – 100 mSv/h |
| Dose Range | 0.01 μSv – 9.99 Sv |
| Dose Measurement Range | 0.1 μSv – 1.99 Sv |
| Relative Measurement Error | ±15% max. |
| Calibration Accuracy | ±5% max. |
| Sensitivity to ¹³⁷Cs | 1.8 cps/(μSv·h⁻¹) |
| Energy Response Range | 50 keV – 3 MeV |
| Energy Dependence (vs. 662 keV ¹³⁷Cs) | ±30% (AT2140), ±25% (AT2140A) |
| Angular Dependence (±60°, ¹³⁷Cs/⁶⁰Co) | ±25% |
| (²⁴¹Am) | ±60% |
| Response Time (Dose Rate >1 � | Sv/h): ≤10 s (AT2140), ≤5 s (AT2140A) |
| Operating Temperature | −20°C to +50°C (AT2140), −30°C to +60°C (AT2140A) |
| Relative Humidity (non-condensing) | ≤95% at 35°C |
| IP Rating | IP40 |
| Drop Resistance | 1.0 m onto hard surface |
| Power Supply | 2 × AA batteries |
| Battery Life | 5,000 h (AT2140), 10,000 h (AT2140A) |
| Dimensions & Weight | 111 × 70 × 28 mm, 0.11 kg |
| Brand | ATOMTEX |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Model | AT2503 |
| Measurement Range (Hp(10)) | 1 µSv – 10 Sv |
| Dose Rate Range (Hp(10)) | 0.1 µSv/h – 0.5 Sv/h |
| Energy Response | 50 keV – 1.5 MeV |
| Dose Accuracy (¹³⁷Cs) | ±5% |
| Dose Rate Accuracy | ±25% (0.1–1 µSv/h), ±15% (>1 µSv/h) |
| Energy Dependence | ±30% |
| Alarm Thresholds | 8 programmable independent levels |
| Detector Type | Energy-compensated GM tube with built-in background tracking |
| Communication | IR interface to reader, RS-232 to PC |
| Calibration | Traceable to water-equivalent phantom (30 × 30 × 15 cm) |
| Brand | AUTOMESS |
|---|---|
| Origin | Germany |
| Model | 6150AD-6 |
| Type | Portable Dose Rate Meter |
| Measurement Principle | Ionization Chamber / GM Tube Based Photon Detection (γ/X-ray) |
| Energy Range | 60 keV – 1.3 MeV |
| Dose Rate Range (Digital) | 0.01 µSv/h – 9.99 mSv/h |
| Dose Rate Range (Analog) | 0.1 µSv/h – 10 mSv/h |
| Alarm Functions | Adjustable Dose & Dose Rate Thresholds |
| Interface | RS232 Serial Port |
| External Probe Support | Up to 100 m cable length (model-dependent) |
| Certification | PTB Certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Power Supply | IEC 6LR61 9 V battery |
| Compliance | Designed for IEC 60846, IEC 61017, and ISO 4037-3 referenced radiation protection applications |
| Brand | Automess |
|---|---|
| Origin | Germany |
| Model | 6150AD-6 |
| Type | Portable Dose Rate Meter |
| Measurement Principle | Ionization Chamber / GM Tube Based Photon Detection (γ/X-ray) |
| Energy Range | 60 keV – 1.3 MeV |
| Dose Rate Range (Digital) | 0.01 µSv/h – 9.99 mSv/h |
| Dose Rate Range (Analog) | 0.1 µSv/h – 10 mSv/h |
| Power Supply | IEC 6LR61 (9 V) Battery |
| Interface | RS232 Serial Port |
| External Probe Cable Length Options | 1.25 m, 3 m, 10 m, 20 m, 75 m, 100 m |
| Compliance | PTB Certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Radiation Dose Rate & Spectral Analyzer |
| Energy Resolution | <65% FWHM @ 5.16 keV (²³⁹Pu) |
| Energy Linearity | ≤±1% (60 keV–2.0 MeV) |
| Long-Term Stability | ≤±1% over 8 h |
| Operating Temperature | +5°C to +35°C |
| Relative Humidity | ≤80% at 30°C |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Detector | φ40 mm × 1 mm Si-PIN X-ray detector |
| Interface | RS-232 serial communication |
| Software | PHA18 Pulse Height Analysis software (Windows 98 compatible) |
| Quality System | ISO 9001 certified |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FJ428G |
| Instrument Category | Dosimeter / Dose Rate Meter |
| Instrument Type | Portable |
| Measured Medium | Air |
| Detector Type | Environmental Radiation Detector |
| Radiation Type | X and γ |
| Measurement Range | (1–10,000) × 10⁻⁸ Gy/h |
| Accuracy | ±10% reading error |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMOUR |
| Pricing | Upon Request |
| Brand | BJBY |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BarracudaX |
| Instrument Type | Laboratory Spectrometer |
| Measurement Medium | X-ray Generators and Radiotherapy Equipment |
| Certification | PTB Certified, CE 413 (MDD Directive), Class IIa Medical Device |
| Sampling Rate | 470 kHz |
| Key | Value |
| Key | Value |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | BY-2020-2 |
| Black Globe Temp. Range | 0–120 °C, ±0.5 °C |
| Wet-Bulb Temp. Range | 0–50 °C, ±0.5 °C |
| Ambient Temp./RH Sensor | −20–120 °C / 0–100% RH, ±0.5 °C / ±3% RH |
| Display | 3.5″ color touch LCD |
| Power | 5000 mAh Li-ion, ≥96 h standby |
| Enclosure | ABS + overmolded TPE, IP30 |
| Mounting | 1/4″ tripod thread |
| Connectivity | M12 digital ports (3×), K-type thermocouple (2×), analog inputs (2×, 0–2 V), Bluetooth 5.0 (≥20 devices), USB-C, Wi-Fi, microSD slot |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | BY-2020-3 |
| Black Globe Temperature Sensor (2020-11) | Range 0–120°C, Accuracy ±0.5°C, Resolution 0.1°C, Stainless Steel Enclosure |
| Ambient Temperature & Humidity Sensor (2020-16) | Temp Range −20–120°C, Accuracy ±0.5°C |
| Anemometer (2020-21) | Range 0–10 m/s, Accuracy ±(0.05 + 0% of reading) for 0.05–2 m/s, ±(0.1 + 2% of reading) above 2 m/s, Resolution 0.01 m/s, RS485 Output |
| Display | 3.5-inch Color Touch LCD |
| Power | Internal 5000 mAh Li-ion Battery (≥96 h standby), DC5V/1A Micro USB Input |
| Data Storage | Removable SD Card, CSV Export |
| Communication | RS485, USB, Wi-Fi, Bluetooth (up to 20 BLE sensors), M12 6-pin Aviation Connectors (3 digital channels), K-type Thermocouple Inputs (2), Analog Inputs (2, 0–2 V, 0.01 mV resolution, ±0.5% accuracy) |
| Enclosure | ABS + TPU Overmold, IP30 Rating, 175 × 92 × 38 mm, 1/4″ Tripod Thread, Detachable Wrist Strap |
| Brand | BJBY |
|---|---|
| Model | BY-EM01 |
| Frequency Range | 1 Hz – 60 GHz (probe-dependent) |
| Measurement Parameters | Electric Field Strength (V/m, kV/m), Magnetic Field Strength (A/m, µT, mT), Power Density (µW/cm², mW/cm²) |
| Probe Compatibility | Four dedicated probe types (LF, HF, UHF, MW) with triaxial isotropic sensors |
| Operating Environment | -20 °C to +55 °C, IP65 (host), IP52 (probes) |
| Battery Life | >8 h (host), >10 h (LF probe), >3 h (HF probe) |
| Data Modes | Real-time, RMS, Max, Time History, Spectrum Analysis, 8-h Weighted Average |
| Compliance | GBZ/T 189.1–189.5, GBZ 2.2, GB 8702, HJ 681, HJ 972, HJ 1136, HJ 1199, IEC 61786-1, IEC 62232, GJB 5313A |
| Connectivity | Fiber-optic (primary), Bluetooth 4.1, USB-C, GPS+AGPS |
| Display | 6.0" 1080p LCD, Android-based touch interface |
| Dimensions (host) | 165.5 × 81.6 × 29.1 mm |
| Weight (host) | 335 g |
| Brand | BJBY (Beijing Baoyun) |
|---|---|
| Model | WBGT-2006 |
| Origin | Imported (U.S.-sourced instrumentation platform) |
| Compliance | GB/T 4200–2008, ISO 7243:1989 |
| Measurement Principle | Simultaneous dry-bulb, natural wet-bulb, and black-globe temperature acquisition for WBGT index calculation |
| Display | Real-time concurrent readout of T<sub>db</sub>, T<sub>nwb</sub>, T<sub>g</sub>, and WBGT value |
| Data Logging | Up to 100 hours internal storage |
| Interface | USB 2.0 for PC connectivity |
| Software | Dedicated Windows-based analysis suite supporting max/min/avg extraction per user-defined time segment |
| Operating Menu | Full Chinese GUI (host unit only) |
| Sensor Type | Digital precision thermistors with direct digital output |
| Dry-Bulb Range | 10–60 °C ±0.5 °C |
| Natural Wet-Bulb Range | 5–40 °C ±0.5 °C |
| Black-Globe Range | 20–120 °C (±0.5 °C @ 20–40 °C |
| Globe Diameter | 150 mm, Emissivity ≥0.95 |
| Wet-Bulb Wicking | Cylindrical cotton sleeve (6±1 mm OD, 30±5 mm length), 20–30 mm free hanging length, water reservoir isolation from radiant heating |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Bonner |
| Instrument Type | Laboratory-Based Neutron Spectrometer |
| Detector Material | Lithium-Based (e.g., ⁶LiI, ⁶Li-glass, ⁶Li-doped plastic scintillator) |
| Radiation Type | Neutron |
| Energy Range | 0.05 MeV – 20 MeV |
| Sensitivity | 0.05 cps/(n·cm⁻²·s⁻¹) |
| Moderator Geometry | Spherical polyethylene shells (5–18 spheres, diameters 0–35 cm) |
| Central Thermal Neutron Detector | ⁶LiI(Eu), ⁶Li-glass, BF₃ or ³He proportional counter |
| Application Domain | Workplace neutron dosimetry, calibration reference, spectral unfolding |