Pharmaceutical Testing Specialized Instruments
Filter
Showing 1–30 of 289 results
| Brand | 3M |
|---|---|
| Model | 6800 |
| Origin | Jiangsu, China (Manufactured under 3M global licensing & quality oversight) |
| Manufacturer Type | OEM/ODM Production Partner |
| Compliance | Meets GB 2890–2023 (China), EN 136:2023 Class 2, and compatible with NIOSH-approved 3M™ filter cartridges (e.g., 6001CN–6006CN series) |
| Weight | Approx. 510 g (without filters) |
| Facepiece Material | Medical-grade silicone |
| Field of View | ≥210° horizontal, ≥105° vertical |
| Exhalation Valve | Cold-flow, downward-oriented dual-valve design |
| Head Harness | Four-point adjustable textile strap system |
| Filter Interface | Standard 40 mm × 1/7″ threaded connection (DIN 3776) |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Acona A2000 SIS |
| Price Range | USD 1,400 – 63,000 |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | Acona A2000SIS CP/USP |
| Price Range | USD 1,400 – 63,000 |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Acona A2000SIS |
| Price Range | USD 1,400 – 63,000 |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction & Light Scattering |
| Dynamic Range | 0.5–400 µm |
| Minimum Sample Volume | 50 µL |
| Resolution | 0.01 µm (1024-channel binning) |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | USP <787>, USP <729>, FDA 21 CFR Part 11, cGMP/GLP |
| Software Features | Audit Trail, Role-Based Access Control, Electronic Signatures, LIMS Integration, Automated Pass/Fail Reporting |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Acona2000SIS |
| Price Range | USD 1,400 – 63,000 |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | OsmoTECH HT |
| Pricing | Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Advanced Instruments, Inc. |
| Product Category | Imported |
| Model | OsmoTECH PRO |
| Pricing | Available Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | OsmoTECH |
| Pricing | Available Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | OsmoTECH XT |
| Price | Upon Request |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | IS-Series Sterile Isolation System |
| Air Cleanliness Class | ISO 5 (Class 100) |
| Filter Efficiency | ≥99.99% @ 0.3 µm |
| Average Air Velocity | 0.45 m/s |
| Power Supply | AC 220 V / 50 Hz |
| Configuration | Custom-engineered footprint (L × W × H, mm) |
| Pressure Control | Dual-mode (positive or negative differential pressure) |
| Transfer Mechanism | Interlocked dual-door pass-through |
| Sterilization Options | Integrated VHP (vaporized hydrogen peroxide) in-situ sterilization or offline autoclave-compatible modular assembly |
| Control System | Microprocessor-based PLC with audit-trail-capable data logging |
| Air Handling | Configurable open-loop or closed-loop recirculation mode |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | MPC 460 |
| Temperature Control Range | 2–8°C (long-term frost-free operation) |
| Control Accuracy | ±0.1°C |
| Temperature Uniformity | 0.5–1.0°C |
| Internal Volume | 460 L |
| Compressor | SECOP (Danfoss Group), R404a refrigerant |
| Condenser Fan | EBM (Germany) |
| Insulation | Monolithic polyurethane foaming |
| Display | 7-inch color TFT touchscreen |
| Data Logging | 3 years of minute-interval records (immutable, USB exportable) |
| Audit Trail | 16,000+ tamper-proof operation & alarm logs |
| User Management | 5 configurable roles with hierarchical permissions |
| Communication Interfaces | RS232, RS485, USB |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating Power | 1200 W |
| Cooling Power | 550 W |
| Operating Ambient | 5–35°C (recommended: 23–27°C) |
| Compliance | Designed to support ICH Q1–Q5, USP <1150>, FDA 21 CFR Part 11 (audit trail & data integrity features), and GLP/GMP-aligned validation protocols |
| Brand | ALISN |
|---|---|
| Model | MPC 760 |
| Temperature Range | 2–8°C (Long-Term Stable Operation) |
| Control Accuracy | ±0.1°C |
| Uniformity | 0.5–1.0°C |
| Internal Volume | 760 L |
| Display | 7-inch Color TFT Touchscreen |
| Data Logging | 3 Years (1-min Interval, Immutable Export via USB) |
| Audit Trail Capacity | 16,000 Entries (Immutable, USB-Exportable) |
| Compressor | SECOP (Danfoss Group), R404a Refrigerant |
| Condenser Fan | EBM (Germany) |
| Insulation | Monolithic Polyurethane Foam (≥40% Energy Savings vs. Conventional Units) |
| Compliance | Designed for ICH Q1A–Q1E, USP <1150>, FDA 21 CFR Part 11 (Audit Trail & User Access Control Enabled) |
| Power Supply | AC 220 V, 50/60 Hz |
| Weight | 295 kg |
| Dimensions (W×H×D) | 1390×1840×937 mm |
| Internal Dimensions (W×H×D) | 1200×1180×540 mm |
| Heating Power | 2000 W |
| Cooling Power | 700 W |
| Sensor | HERAEUS Platinum RTD (Class A) |
| Interface | RS232, RS485, USB Host/Device |
| Door | Dual-Glass with Silicone Port (Ø50 mm), Tempered Inner Door |
| User Management | 5 Configurable Accounts with Role-Based Permissions |
| Multi-Point Temperature Calibration | Supported |
| Operating Ambient | 5–35°C (Optimal: 23±2°C) |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | QCA 1000 |
| Chamber Volume | 1000 L |
| Temperature Range (Dark) | −10 to +65 °C |
| Temperature Range (Illuminated) | +4 to +65 °C |
| Temperature Uniformity (at 25 °C, dark) | ±0.3–0.8 °C |
| Control Accuracy | ±0.1 °C |
| Illuminance Range | 0–10,000 lux (continuously adjustable) |
| UV Spectral Range | 320–400 nm |
| UV Irradiance | 0–5 W/m² |
| Light Source | D65 daylight simulator + ICH Q1B-compliant UV module |
| Cooling System | Inverter-driven SECOP (Danfoss) compressor with R404a refrigerant |
| Humidity Control | Not applicable (dry operation only) |
| Data Logging | 3-year storage (1-min interval), USB export, write-protected |
| Audit Trail | 16,000 entries (user actions & alarms), non-modifiable, USB exportable |
| User Management | Up to 5 configurable roles with hierarchical permissions |
| Interface | 7-inch color TFT touch screen, RS232/RS485/USB ports, bilingual (EN/CN) menu |
| Insulation | Monolithic polyurethane foam, thermal conductivity ≤0.022 W/(m·K) |
| Construction | Double-door design with tempered inner glass door, 50 mm silicone rubber port on right side |
| Compliance | Designed per ICH Q1B, ICH Q5C, USP <115>, ISO 14644-1 Class 8 (cleanroom-compatible airflow management) |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | QCA 460 |
| Control Method | PID + Fuzzy Logic |
| Temperature Range | 4°C to 65°C |
| Temperature Uniformity (20–45°C, no light) | ±0.2–0.5°C |
| Temperature Accuracy | ±0.1°C |
| Illumination Source | ICH-compliant D65 daylight simulator (6500 K) and UV-A (320–400 nm) |
| Visible Light Intensity | 0–8000 lux (continuously adjustable) |
| UV Irradiance | 0–5 W/m² |
| Internal Volume | 460 L |
| Dimensions (W×H×D) | 933×1765×960 mm |
| Net Weight | 210 kg |
| Refrigeration System | Inverter-driven SECOP (Danfoss) compressor with R290 eco-refrigerant |
| Humidity Sensor | E+E Electronics |
| Temperature Sensor | Heraeus platinum RTD |
| Data Storage | ≥10 years of raw test data |
| Compliance | Designed to support ICH Q1B, Q5C, and WHO TRS 992 Annex 6 requirements |
| Brand | ALISN |
|---|---|
| Model | QCA 760 |
| Internal Volume | 760 L |
| Temperature Range (with illumination) | 4°C to 65°C |
| Temperature Uniformity (15–45°C, no light) | ±0.3–0.8°C |
| Temperature Accuracy | ±0.1°C |
| Illumination Source | D65 daylight simulating lamp + UV-A (320–400 nm) |
| Illuminance Range | 0–8000 lux (continuously adjustable) |
| UV Irradiance Range | 0–5 W/m² |
| Control System | PID + fuzzy logic algorithm |
| Display | 7-inch full-color TFT touch screen |
| Data Logging | 10-year continuous storage (immutable, USB export only) |
| Audit Trail Capacity | 16,000 entries (user actions & alarms) |
| Compressor | SECOP (Danfoss), R404a refrigerant |
| Condenser Fan | EBM (Germany) |
| Insulation | Monolithic polyurethane foam |
| Power Supply | AC 220 V, 50/60 Hz |
| Weight | 295 kg |
| Dimensions (W×H×D) | 1490×1790×887 mm |
| Interior Dimensions (W×H×D) | 1300×1180×500 mm |
| Compliance | ICH Q1B, Q5C, ISO 15270, USP <115> |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | STC 1000 |
| Price | USD 21,500 (FOB Shanghai) |
| Control Method | PID + Fuzzy Logic |
| Display | 7-inch Full-Color TFT Touchscreen |
| Temperature Range (Dark) | –10°C to +85°C |
| Temperature Range (Illuminated) | +10°C to +65°C |
| Humidity Range (Dark) | 15–95% RH ±1.5% RH |
| Humidity Range (Illuminated) | 20–95% RH ±1.5% RH |
| Temp Uniformity (15–45°C, Dark) | ±0.2–0.5°C |
| Temp Accuracy | ±0.1°C |
| Humidity Fluctuation | ±1.5% RH |
| Illumination | ICH-compliant D65 daylight simulator (0–8000 lux, 6-step adjustable |
| UV Spectrum | 320–400 nm (UVA) |
| Internal Volume | 1012 L |
| Interior Dimensions (W×H×D) | 1300 × 1180 × 660 mm |
| External Dimensions (W×H×D) | 1490 × 1790 × 1050 mm |
| Net Weight | 355 kg |
| Heating & Humidification Power | 3200 W |
| Refrigeration | Inverter-driven SECOP (Danfoss) compressor + EBM condenser fan |
| Refrigerant | Eco-friendly R134a |
| Insulation | Monolithic polyurethane foam (≥120 mm thickness) |
| Humidity Sensor | E+E Elektronik (Austria) |
| Temperature Sensor | Heraeus (Germany) |
| Data Logging | 10-year non-volatile storage |
| Audit Trail Capacity | 16,000 entries (user actions & alarms) |
| User Management | 5 configurable roles with granular permissions |
| Communication Ports | RS232, RS485, USB host/device |
| Compliance | ICH Q1A(R3), Q5C, ISO 14644-1 Class 8 (cleanroom-compatible operation), GLP/GMP-ready architecture |
| Safety Features | Over-temperature cutoff, compressor high-pressure protection, leak current detection, door-open alarm, low-water cutoff, sensor fault monitoring |
| Brand | ALISN |
|---|---|
| Model | STC 460 |
| Temperature Control Range (Dark) | –10°C to 85°C |
| Temperature Control Range (Illuminated) | 10°C to 65°C (–20°C to 100°C optional) |
| Humidity Range (Dark) | 15–95% RH ±1.5% RH |
| Humidity Range (Illuminated) | 20–95% RH ±1.5% RH |
| Temperature Uniformity (at 25°C, dark) | ±0.2–0.5°C |
| Temperature Accuracy | ±0.1°C |
| Humidity Fluctuation | ±1.5% RH |
| Illumination Intensity | 0–8000 lux (6-step adjustable |
| UV Spectrum Module | 320–400 nm (UVA) |
| Internal Volume | 460 L |
| Refrigerant | R-404a |
| Compressor | Secop (Danfoss) |
| Humidity Sensor | E+E Elektronik |
| Temperature Sensor | Heraeus |
| Insulation | Monolithic polyurethane foam |
| Power Supply | AC 220 V, 50/60 Hz |
| Total Heating & Humidification Power | 2300 W |
| Cooling Power | 550 W |
| Net Weight | 210 kg |
| Dimensions (W×H×D) | 930×1800×885 mm |
| Interior Dimensions (W×H×D) | 770×1200×500 mm |
| Data Logging Capacity | >10 years of raw data |
| Audit Trail Storage | 16,000 entries |
| User Accounts | Up to 5 with role-based permissions |
| Communication Interfaces | USB, RS-232, RS-485 |
| Language Support | English / Chinese toggle |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | STC 760 |
| Price | USD 19,800 (FOB Shanghai) |
| Control System | PID + Fuzzy Logic |
| Display | 7-inch Color TFT Touchscreen |
| Temperature Range (Dark) | −10°C to +85°C |
| Temperature Range (Illuminated) | +10°C to +65°C |
| Humidity Range (Dark) | 15–95% RH ±1.5% RH |
| Humidity Range (Illuminated) | 20–95% RH ±1.5% RH |
| Temperature Uniformity (at 25°C, dark) | ±0.3°C |
| Temperature Stability | ±0.1°C |
| Humidity Stability | ±1.5% RH |
| Illumination | ICH-compliant D65 daylight simulator (0–8000 lux, 6-step adjustable |
| UV Spectrum | 320–400 nm (UVA) |
| Internal Volume | 767 L |
| Interior Dimensions (W×H×D) | 1300 × 1180 × 500 mm |
| External Dimensions (W×H×D) | 1490 × 1790 × 887 mm |
| Net Weight | 295 kg |
| Refrigeration | Inverter-driven SECOP (Danfoss) compressor + EBM condenser fan |
| Refrigerant | Eco-friendly R134a/R600a blend |
| Insulation | Monolithic polyurethane foam (≥120 mm thickness) |
| Humidity Sensor | E+E Electronics capacitive RH sensor |
| Temperature Sensor | Heraeus Pt100 Class A |
| Data Logging | ≥10 years of uneditable timestamped data (internal flash + USB export) |
| Audit Trail | 16,000 entries (user actions, alarms, parameter changes) |
| User Management | 5 configurable roles with granular permissions |
| Communication Ports | RS232, RS485, USB host/device |
| Compliance | Designed to support ICH Q1A(R2), Q1B, Q5C |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | STC-150 |
| Control System | PID + Fuzzy Logic |
| Display | 7-inch Color TFT Touchscreen |
| Temperature Range (Dark) | –10°C to +85°C |
| Temperature Range (Illuminated) | +10°C to +65°C |
| Humidity Range (Dark) | 15–95% RH ±1.5% RH |
| Humidity Range (Illuminated) | 20–95% RH ±1.5% RH |
| Temperature Uniformity (at 25°C, dark) | ±0.2–0.5°C |
| Temperature Stability | ±0.1°C |
| Humidity Fluctuation | ±1.5% RH |
| Illumination | ICH-compliant D65 daylight simulation (0–8000 lux, 6-step adjustable |
| UV Spectrum | 320–400 nm (UVA) |
| Internal Volume | 150 L |
| Interior Dimensions (W×H×D) | 600×620×405 mm |
| External Dimensions (W×H×D) | 780×1200×802 mm |
| Net Weight | ~125 kg |
| Heating & Humidification Power | 1550 W |
| Refrigeration | Inverter-driven SECOP (Danfoss) compressor with EBM condenser fan |
| Refrigerant | Eco-friendly R134a or equivalent |
| Insulation | Monolithic polyurethane foam (≥80 mm thickness) |
| Humidity Sensor | Imported E+E Electronics capacitive sensor |
| Temperature Sensor | HERAEUS precision Pt100 |
| Communication Interfaces | RS232, RS485, USB |
| Data Logging | 10-year continuous storage (immutable, exportable via USB) |
| Audit Trail | ≥16,000 entries (user actions, alarms, system events) |
| User Management | Up to 5 configurable accounts with role-based permissions |
| Multi-point Temperature Calibration | Supported |
| Door Design | Dual-door (outer insulated door + inner tempered glass door) |
| Port | Ø50 mm silicone-sealed access port (right side) |
| Compliance | Designed per ICH Q1A(R2), Q1B, Q5C |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | BP-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Print Output | Bilingual (English/Chinese), including test parameters, results, and pressure decay curves |
| Environmental Operating Conditions | 0–50 °C, 10–80% RH |
| Test Duration | Bubble point: 2 ± 2 min |
| Diffusion flow | 7 ± 2 min |
| Water intrusion | 7 ± 2 min |
| System leak check | 3 ± 1 min |
| Communication Interface | RS232/USB for PC connectivity and remote supervision via proprietary software |
| Compliance Support | Fully compatible with FDA 21 CFR Part 11 audit trail requirements, EU Annex 1, USP <1207>, ISO 13408-2, and GMP Annex 15 integrity testing protocols |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BQS |
| Price Range | USD 1,400 – 2,800 |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 9000 mbar (145 psi) |
| Min Inlet Pressure | 4000 mbar (58 psi) |
| Dimensions | 400 × 380 × 335 mm (W × D × H) |
| Test Pressure Range | 100–8000 mbar (1.5–116 psi) |
| Accuracy | Net Volume Test ±4% |
| Environmental Conditions | 15–35 °C |
| Test Duration | Net Volume Test 5±2 min |
| Water Intrusion Test | Set Time + 5±2 min |
| Display | 5.7″ backlit monochrome LCD |
| Data Interface | RS232 serial port |
| Language Options | English / Chinese |
| Storage Capacity | 500 test records (incl. curves) |
| Print Output | Dot-matrix printer (Chinese/English), full parameter + result + curve |
| Sample Compatibility | Disc membranes Φ25–Φ300 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Test Pressure | 6900 mbar (sensor customizable) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–80% RH |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal, ≥1 million test records |
| Print Output | Thermal printer, bilingual (English/Chinese), includes test parameters, results, and pressure decay curves |
| Test Duration | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 Series |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Test Duration (Bubble Point) | 2 ± 2 min |
| Test Duration (Diffusion Flow / Water Intrusion) | 7 ± 2 min |
| System Leak Test Time | 3 ± 1 min |
| Display | 5.7-inch 32-bit touchscreen |
| Data Storage | 32 GB (≥1 million records) |
| Interface | RS232/USB/Ethernet for PC connectivity |
| Compliance Support | FDA 21 CFR Part 11 (audit trail enabled), GMP/GLP-ready |
| Language Options | English & Chinese |
| Dimensions | 500 × 200 × 180 mm (L×W×H) |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BQS-19+ |
| Power Supply | 100–240 V AC, 50/60 Hz, ≤100 W |
| Max Operating Pressure | 9999 mbar |
| Min Inlet Pressure | 4000 mbar |
| Pressure Range for Testing | 100–8000 mbar (1.5–116 psi) |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Net Volume Test Accuracy | ±4% |
| Test Duration (Bubble Point) | 15 ± 2 min |
| Test Duration (Enhanced Bubble Point) | 20 ± 2 min |
| Test Duration (Diffusion Flow) | 10 ± 2 min |
| Display | 5.7" monochrome TFT LCD |
| Interface | RS232 serial port |
| Data Storage | 500 test records (configurable extension via PC connection) |
| Environmental Operating Conditions | 5–35 °C, 10–80% RH |
| Dimensions (W × D × H1 × H2) | 400 × 380 × 100 × 235 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BQS-40 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Maximum Operating Pressure | 7999 mbar |
| Inlet Gas Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Compliance | CE certified, FDA 21 CFR Part 11 compliant architecture, GMP-aligned audit trail |
| Enclosure Rating | IP54 |
| Supported Test Methods | Bubble Point, Diffusion Flow, Pressure Hold (Decay), Water Intrusion |
| Brand | All Precision Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | S-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color TFT touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal flash memory (≥1 million test records) |
| Communication Interface | RS232/USB/Ethernet for PC connectivity and remote supervision |
| Compliance | Designed to support GMP, FDA 21 CFR Part 11 (audit trail ready), ISO 13408-2, ASTM F838, USP <1207> |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | D1200 PRO |
| Instrument Type | Online Sampling Dissolution System |
| Vessels | 12 |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Volume | 46 L |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Model | D1200 |
| Instrument Type | Online Dissolution System |
| Vessel Capacity | 12 vessels |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Volume | 46 L |
| Compliance | Chinese Pharmacopoeia 2020 Edition, General Chapter <0931> Dissolution and Release Testing |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | D1200 PRO Immersion Cell |
| Instrument Type | Online Dissolution Sampling System |
| Dissolution Vessels | 12-position |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Volume | 46 L |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | R3000 PRO |
| Instrument Type | Offline Dissolution System |
| Vessel Configuration | 7-position × 6-row cylinder rack |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
