| Brand | AIRTECH (Sujing Antai) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BLB-1000 |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical downward laminar flow |
| Work Surface Material | Seamless stainless steel (AISI 304) |
| Viewing Panels | Tempered glass side windows |
| Cabinet Construction | Cold-rolled steel with white electrostatic powder coating |
| Pre-filter | Washable aluminum mesh |
| HEPA Filter | 915 × 610 × 50 mm, single unit, H14 grade (EN 1822) |
| Average Air Velocity | ≥0.3 m/s (adjustable via 3-speed electronic control) |
| Illumination | ≥300 lx (LED lighting system) |
| Power Supply | AC 220 V, 1-phase, 50 Hz |
| Rated Power | 250 W |
| Net Weight | 190 kg |
| Working Area Dimensions (W×D×H) | 800 × 615 × 720 mm |
| Overall Dimensions (W×D×H) | 1000 × 810 × 1795 mm |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| UV Lamp | 254 nm germicidal lamp with programmable on/off scheduling |
| Safety Interlock | Lighting and UV sterilization systems mutually interlocked |
| Casters | Dual-mode—swivel with brake + adjustable leveling feet |
| Compliance | Meets YY 0569–2011 (Chinese standard for biological safety cabinets), GB/T 25220–2010 (clean bench performance testing), and general requirements of ISO 14644-1 for cleanroom equipment |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | HHS-1000-U / HHS-1300-U / HHS-1600-U / HHS-1800-U |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US FED-STD-209E) |
| Airflow Pattern | Horizontal laminar flow |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-front or dual-user single-front |
| Compliance | YY/T 1539–2017 (China CFDA Medical Device Standard), Class II Medical Device Registration Certificate |
| Control Interface | Full-color LCD touchscreen with real-time display of airflow velocity, filter status, and fault diagnostics |
| Safety Interlocks | Integrated interlock between sash position, UV germicidal lamp activation, and LED lighting |
| Construction | Seamless curved stainless steel work surface (304 grade), ergonomically optimized for prolonged operation |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | HS-840, HS-840-U, HS-1300, HS-1300-U |
| Instrument Category | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate issued |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-840-II |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100 per Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Average Air Velocity | ≥0.3 m/s (adjustable) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 250 W |
| Net Weight | 125 kg |
| Work Area Dimensions (W×D×H) | 720 × 650 × 570 mm |
| Overall Dimensions (W×D×H) | 840 × 825 × 1430 mm |
| HEPA Filter Specification | 760 × 610 × 50 mm × 1 unit |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| Pre-filter | Quick-release, washable design |
| Safety Compliance | Meets GB/T 25225–2010 (Chinese National Standard for Laminar Flow Clean Benches), IEC 61010-1:2010 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | HS-840-II, HS-1300-II, HS-840-U-II, HS-1300-U-II |
| Instrument Category | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Sound Pressure Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Control Interface | Digital display with touch-sensitive keypad |
| Fan Speed | 3-step adjustable |
| UV Lamp Control | Programmable on/off scheduling |
| Runtime Monitoring | Real-time cumulative operating time for fan, UV lamp, and filter |
| Viewing Panels | Embedded tempered glass on both side walls |
| Work Surface | Seamless 304 stainless steel with front-radius edge design |
| Cabinet Material | Cold-rolled steel with ivory-white electrostatic powder coating |
| Structural Design | Aerodynamically optimized chassis minimizing airflow turbulence |
| Mobility System | Dual-mode casters (swivel + locking brake) with leveling feet |
| Pre-filter Access | Tool-free rapid replacement and washable design |
| Safety Interlock | UV lamp and lighting circuits mutually interlocked |
| Power Features | Integrated backup socket with power-fail protection |
| Factory Certification | Performed per ISO 14644-1, IEST-RP-CC002.3, and GB/T 25227–2010 performance validation protocols |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | HVS-1000-U, HVS-1300-U, HVS-1600-U, HVS-1800-U |
| Classification | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Noise Level | ≤62 dBA |
| Operator Configuration | Single-user single-front or dual-user single-front |
| Airflow Pattern | Vertical downward laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate issued |
| Control Interface | Full-color LCD touchscreen with real-time display of inflow velocity, filter status, and fault alerts |
| Safety Interlocks | Integrated interlock between sash position, UV germicidal lamp activation, and lighting system |
| Construction | Seamless curved stainless steel work surface (304 grade), ergonomically contoured front edge |
| Fan System | Variable-air-volume (VAV) EC motor-driven blower with high-efficiency low-energy operation |
| Lighting | Uniform LED illumination (≥600 lux at work surface) |
| Pre-shipment Testing | 100% factory validation per ISO 14644-1 and YY/T 1539–2017 performance & safety protocols |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | SW-CJ-1B, SW-CJ-1BU, SW-CJ-1C, SW-CJ-1CU |
| Instrument Category | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (CFDA Medical Device Standard), Class II Medical Device Registration Certificate |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | SW-CJ-1F, SW-CJ-1FD, SW-CJ-2F, SW-CJ-2FD |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-Operator Single-Face, Single-Operator Dual-Face, Dual-Operator Single-Face, Dual-Operator Dual-Face |
| Airflow Pattern | Vertical Downflow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate Issued |
| Brand | AIRTECH (Suzhou Antai) |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (equivalent to US FED STD 209E Class 100) |
| Noise Level | ≤62 dB(A) |
| User Configuration | Dual-operator, dual-sided (SW-CJ-2F) or dual-operator, single-sided (SW-CJ-2FD) |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Average Air Velocity | ≥0.3 m/s (adjustable) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 500 W |
| Weight | 170 kg |
| Work Area Dimensions (W×D×H) | 1360×690×520 mm (SW-CJ-2F), 1360×690×520 mm (SW-CJ-2FD) |
| Overall Dimensions (W×D×H) | 1500×750×1600 mm (SW-CJ-2F), 1500×730×1600 mm (SW-CJ-2FD) |
| HEPA Filter Specification | 610×610×50 mm ×2 units |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| Pre-filter | Quick-access washable design |
| Control Interface | Digital display with touch keys |
| Safety Interlock | UV lamp and lighting circuit interlocked |
| UV Timer Function | Programmable on/off scheduling |
| Runtime Monitoring | Real-time cumulative operating hours for fan, UV lamp, and HEPA filter |
| Construction | Stainless steel monolithic work surface |
| Mobility | Locking omnidirectional casters |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | SW-CJ-1B / SW-CJ-1BU / SW-CJ-1C / SW-CJ-1CU-II |
| Instrument Type | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single- or Dual-Operator, Front-Access Only |
| Airflow Pattern | Horizontal Laminar Flow |
| Control Interface | Digital Display with Touch-Sensitive Keypad |
| UV Timer Function | Programmable On/Off Scheduling |
| Runtime Monitoring | Real-Time Accumulated Hours for Fan, UV Lamp, and Pre-Filter |
| Viewing Panels | Embedded Tempered Glass on Both Sides |
| Work Surface | Seamless Stainless Steel (AISI 304) |
| Enclosure Material | Cold-Rolled Steel with Ivory White Electrostatic Powder Coating |
| Structural Design | Aerodynamically Optimized Cabinet Profile |
| Mobility System | Locking Swivel Casters (360° Rotation) |
| Pre-Filter Access | Tool-Free Quick-Release Mechanism |
| Safety Interlock | UV Lamp Deactivation When Lighting Circuit Is Active |
| Power Protection | Built-in Backup Socket with Emergency Power-Off Capability |
| Compliance | Factory-Tested per GB/T 25227–2010 (Chinese National Standard for Clean Benches), Meets IEC 61010-1 Safety Requirements for Laboratory Equipment |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | SW-CJ-1F, SW-CJ-1FD, SW-CJ-2F, SW-CJ-2FD-II |
| Airflow Type | Vertical Downflow |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| Operator Configurations | Single-Person/Single-Side, Single-Person/Double-Side, Double-Person/Single-Side, Double-Person/Double-Side |
| Construction | Stainless Steel Work Surface, Powder-Coated Cold-Rolled Steel Enclosure |
| Pre-Filter | Quick-Release Design for Easy Cleaning and Replacement |
| UV Lamp Control | Programmable On/Off Scheduling with Runtime Monitoring |
| Fan Speed | Three-Step Adjustable |
| Safety Interlock | Lighting and UV Sterilization Systems Are Electrically Interlocked |
| Power Protection | Built-in Uninterruptible Power Backup Function |
| Mobility | Locking Swivel Casters with Brake Mechanism |
| Compliance | Factory-Tested per GB/T 25223–2010 (Chinese National Standard for Clean Benches), Meets General Requirements of YY 0569–2011 (Medical Device Safety for Biological Safety Cabinets) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VS-840K-II |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100 per Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Average Air Velocity | ≥0.3 m/s (adjustable in three stages) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 250 W |
| Net Weight | 145 kg |
| Work Area Dimensions (W×D×H) | 680 × 650 × 570 mm |
| Overall Dimensions (W×D×H) | 840 × 825 × 1625 mm |
| HEPA Filter Specification | 760 × 610 × 50 mm × 1 unit |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| Pre-filter | Quick-release, washable design |
| UV Lamp | Scheduled on/off control with runtime logging |
| Safety Interlock | Lighting and UV sterilization systems mutually interlocked |
| Foot Mobility | Dual-mode casters (swivel + locking leveling feet) |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | Phantom2 |
| Certification | ISO 14644-1 Class 3 Verified |
| Filtration | Dual-stage HEPA (≥99.995% @ 0.3 µm) |
| Airflow System | Unidirectional laminar flow with Active Barrier Control (ABC) |
| Work Area Opening Height | Up to 406 mm |
| Height Adjustment | Motorized, 305 mm travel with 4 programmable memory positions |
| Lighting | Adjustable-intensity LED (6000K white + red-light mode) |
| Display | Full-color touchscreen interface (8 languages) |
| Construction | Tempered safety glass (6 mm), polycarbonate rear panel (6 mm), IP-rated USB 2.0 ports |
| Motor | Energy-efficient ECM fan with ±1% airflow stability under variable filter load |
| Cabinet Temperature Rise | <1 °C during operation |
| Mobility | 127 mm polyurethane casters with brakes |
| Compliance | Designed for GLP/GMP-aligned animal facilities |
| Brand | AnTai |
|---|---|
| Origin | Jiangsu, China |
| Model | BCM-1000A |
| Instrument Category | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to US FED-STD-209E Class 100) |
| Noise Level | ≤62 dB(A) |
| User Configuration | Single-operator, dual-front access |
| Airflow Pattern | Vertical downward laminar flow |
| Average Air Velocity | 0.25–0.45 m/s (adjustable) |
| Exhaust Air Volume | 2 m³/min |
| Vibration (Half-Peak) | ≤5 µm |
| Illuminance | ≥300 lx |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 0.8 kW |
| Net Weight | 300 kg |
| Work Area Dimensions (W×D×H) | 1000 × 700 × 620 mm |
| Overall Dimensions (W×D×H) | 1160 × 760 × 1780 mm |
| Supply HEPA Filter | 915 × 610 × 50 mm (1 unit) |
| Exhaust HEPA Filter | 480 × 90 × 50 mm (1 unit) |
| Fluorescent Lamp | 20 W × 2 |
| UV Lamp | 20 W × 2 |
| Optional Outlets | 2 kW rated socket |
| Brand | AnTai |
|---|---|
| Origin | Jiangsu, China |
| Model | HS-1300-U |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100) |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Noise Level | ≤62 dB(A) |
| Operating Configuration | Dual-user, single-face workstation |
| Average Air Velocity | 0.3–0.6 m/s (adjustable) |
| Vibration (half-peak) | ≤3 µm |
| Illuminance | ≥300 lx |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 0.4 kW |
| Net Weight | 160 kg |
| Work Area Dimensions (W×D×H) | 1180 × 650 × 570 mm |
| External Dimensions (W×D×H) | 1300 × 825 × 1430 mm |
| Pre-filter Airflow Control | Adjustable aluminum damper |
| Filter Type | Ultra-thin, bag-type HEPA filter (no separator design) |
| Work Surface | Imported stainless steel |
| Side Panels | Tempered glass |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Models | SW-CJ-2F, SW-CJ-2FD, SW-CJ-1F, SW-CJ-1FD |
| Price Range | USD 1,400 – 2,800 (FOB China) |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Dual-Operator, Single-Face Configuration |
| Airflow Pattern | Vertical Unidirectional Flow |
| Work Surface Velocity | ≥0.3 m/s (adjustable) |
| Illuminance | ≥300 lx |
| Power Supply | AC 220 V / 50 Hz, Single-Phase |
| Input Power | 500 VA |
| Net Weight | 170 kg |
| Working Area Dimensions | 1360 × 690 × 520 mm (W × D × H) |
| Overall Dimensions | 1500 × 750 × 1600 mm (W × D × H) |
| HEPA Filter Specification & Quantity | 610 × 610 × 50 mm, 2 units |
| Fluorescent Lamp / UV Lamp | 14 W × 2 / 5 W × 2 |
| Microbial Contamination | ≤0.5 CFU/plate (90 mm Petri dish, 1-hour exposure) |
| Compliance | GB/T 16292–2010, YY 0569–2011, ISO 14644-1:2015 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | VD-650-U / VD-650 |
| Price Range | USD 700 – 1,400 |
| Instrument Category | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (equivalent to Class 100 per Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, front-access only |
| Airflow Pattern | Vertical downward laminar flow |
| Average Air Velocity | ≥0.3 m/s (continuously adjustable) |
| Illuminance | ≥300 lx |
| Power Supply | 220 VAC, 50 Hz, single-phase |
| Input Power | 250 W |
| Net Weight | 60 kg |
| Work Area Dimensions | 615 × 495 × 500 mm (W×D×H) |
| External Dimensions | 650 × 535 × 835 mm (W×D×H) |
| HEPA Filter Specification | 610 × 450 × 50 mm, single unit |
| Lighting | 14 W fluorescent lamp × 1 |
| UV Lamp | 8 W germicidal lamp × 1 |
| Microbial Contamination | ≤0.5 CFU/plate·hour |
| Brand | Bigneat |
|---|---|
| Origin | United Kingdom |
| Model | BW UV PCR |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level) |
| Noise Level | <50 dB(A) |
| Airflow Direction | Vertical Downflow |
| User Configuration | Single-Operator, Front-Access |
| UV Lamp Power | 254 nm Germicidal UV-C |
| UV Exposure Timer | Adjustable 5–30 min |
| Work Surface Material | PVC-coated Black Tray |
| Viewing Window | 8 mm Acrylic, UV-blocking |
| Safety Interlock | Automatic UV shutoff upon sash movement |
| Air Velocity | 0.45 m/s (sash-open mode), 0.3 m/s (standard operation) |
| Illumination | 15 W White LED Lamp (externally controlled) |
| Structural Frame | Powder-coated Low-Carbon Steel |
| Compliance | EN 12464-1, EN 1822, IEC 61000-6-3, CE Marked |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BJ-1CD / BJ-2CD |
| Airflow Type | Vertical Downflow |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100 @ ≥0.5 µm) |
| Adjustable Air Velocity Range | 0.1–0.6 m/s |
| Noise Level | ≤62 dB(A) |
| Illuminance | ≥300 lx |
| Vibration Half-Peak Amplitude | ≤3 µm (X/Y/Z axes) |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 0.2 kW (BJ-1CD) / 0.37 kW (BJ-2CD) |
| Net Weight | 115 kg (BJ-1CD) / 205 kg (BJ-2CD) |
| Work Area Dimensions | 830 × 700 × 520 mm (BJ-1CD) / 1300 × 700 × 520 mm (BJ-2CD) |
| External Dimensions | 891 × 725 × 1577 mm (BJ-1CD) / 1460 × 725 × 1577 mm (BJ-2CD) |
| HEPA Filter Specifications | 765 × 548 × 50 mm × 1 (BJ-1CD) / 1236 × 549 × 50 mm × 1 (BJ-2CD), Unibody Pleated HEPA, ≥99.995% @ 0.3 µm |
| Pre-filter | Synthetic Fiber Medium-Efficiency Panel Filter |
| Lighting | 30 W Fluorescent Lamp × 1 + 20 W UV Lamp × 1 (BJ-1CD) / 40 W Fluorescent Lamp × 1 + 30 W UV Lamp × 1 (BJ-2CD) |
| Safety Interlock | UV Lamp & Main Light Interlocked |
| Control Interface | LCD Display with Real-Time Parameters (Air Velocity, Differential Pressure, Cumulative Operating Time, Clock, HEPA Status) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BJ-1CD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Working Surface Dimensions (W×D×H) | 830 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 990 × 744 × 1680 mm |
| HEPA Filter Specification | 800 × 604 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Fan Type | High-efficiency centrifugal blower |
| Air Velocity Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Illumination | ≥300 lx (30 W fluorescent lamp) |
| UV Germicidal Lamp | 20 W |
| Vibration Amplitude | ≤5 µm (peak-to-peak, X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 0.2 kW |
| Net Weight | 115 kg |
| Work Surface Material | SUS304 brushed stainless steel |
| Cabinet Material | Cold-rolled steel with epoxy-powder coating |
| Control Interface | LCD display with multi-parameter monitoring |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BJ-1CD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Working Surface Dimensions (W×D×H) | 830 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 990 × 744 × 1680 mm |
| HEPA Filter Specification | 800 × 604 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Air Velocity Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Illumination | ≥300 lux (30 W fluorescent lamp) |
| UV Germicidal Lamp | 20 W |
| Vibration Amplitude (peak-to-peak) | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.2 kW |
| Net Weight | 115 kg |
| Control Interface | LCD display with multi-parameter readout (air velocity, cumulative operating time, filter pressure differential, clock, HEPA status) |
| Safety Features | Interlocked UV and lighting circuits, audible/visual HEPA failure alarm, sash position sensing, splash-proof internal power sockets, integrated gas/water ports |
| Construction | Cold-rolled steel outer casing, SUS304 brushed stainless steel work surface |
| Ergonomics | 5° forward-sloping front panel, counterbalanced vertical sliding sash, casters with leveling feet |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BJ-2CD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-Operator, Single-Face Configuration |
| Airflow Pattern | Vertical Unidirectional Flow |
| Working Surface Dimensions | 1300 × 700 × 495 mm (W × D × H) |
| Overall Dimensions | 1460 × 744 × 1680 mm (W × D × H) |
| HEPA Filter Specification | 1270 × 604 × 50 mm, single unit |
| Illumination | ≥300 lux (fluorescent lamp, 40 W) |
| UV Lamp | 30 W, germicidal |
| Vibration Amplitude | ≤5 µm (peak-to-peak, X/Y/Z axes) |
| Adjustable Air Velocity Range | 0.3–0.6 m/s (6-step digital setpoint with real-time display) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.37 kW |
| Net Weight | 205 kg |
| Control Interface | LCD panel with multi-parameter real-time monitoring |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BJ-2CD |
| Price Range | USD 1,400 – 2,800 |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-Operator, Single-Face Configuration |
| Airflow Pattern | Vertical Unidirectional Flow |
| Work Surface Dimensions (W×D×H) | 1300 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 1460 × 744 × 1680 mm |
| HEPA Filter Specification | 1270 × 604 × 50 mm (1 unit) |
| Illumination | ≥300 lx (40 W fluorescent lamp) |
| UV Sterilization Lamp | 30 W |
| Operating Air Velocity Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Vibration Amplitude (Peak-to-Peak) | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 0.37 kW |
| Net Weight | 205 kg |
| Display | LCD with multi-parameter readout (air velocity, cumulative operating time, filter differential pressure, clock, HEPA status) |
| Safety Features | Interlocked UV and lighting circuits, HEPA integrity alarm (audible + visual), pre-filter + HEPA dual-stage filtration, counterbalanced sash, 5° ergonomic front tilt, integrated splash-proof power sockets and utility ports (gas/water) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BJ-3CD |
| Instrument Category | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| Airflow Pattern | Vertical Downflow |
| Rated User Capacity | Three-person, single-sided operation |
| Working Surface Dimensions (W×D×H) | 1800 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 1960 × 744 × 1680 mm |
| HEPA Filter Specification | 1770 × 604 × 50 mm, single unit |
| Illumination | ≥300 lux (fluorescent lamp, 30 W × 2) |
| UV Lamp | 30 W × 1 |
| Average Air Velocity Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Vibration Peak-to-Peak Amplitude | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.55 kW |
| Net Weight | 280 kg |
| Construction Materials | Cold-rolled steel housing |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BJ-3CD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Three-person single-sided operation |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Working Surface Dimensions (W×D×H) | 1800 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 1960 × 744 × 1680 mm |
| HEPA Filter Specification | 1770 × 604 × 50 mm (1 unit) |
| Illumination | ≥300 lux (30 W fluorescent ×2) |
| UV Lamp | 30 W ×1 |
| Operating Wind Speed Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Vibration Amplitude | ≤5 µm (peak-to-peak, X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.55 kW |
| Net Weight | 280 kg |
| Control Interface | LCD panel with multi-parameter real-time monitoring |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SW-CJ-1BU |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-user, single-face configuration |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Working Surface Air Velocity Range | 0.3–0.6 m/s (adjustable in six discrete steps) |
| Vibration Peak-to-Peak Amplitude | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lux |
| Work Area Dimensions (W×D×H) | 910 × 480 × 570 mm |
| Overall Dimensions (W×D×H) | 910 × 790 × 1380 mm |
| HEPA Filter Specification | 815 × 575 × 50 mm (single unit) |
| Pre-filter | Medium-efficiency panel filter |
| Lighting | 20 W fluorescent lamp (1 unit) |
| UV Germicidal Lamp | 20 W (1 unit, timer-controlled: 0–999 min) |
| Construction Materials | Cold-rolled steel housing with epoxy powder coating |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.15 kW |
| Net Weight | 110 kg |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Horizontal Laminar Flow Clean Bench |
| Model | SW-CJ-1BU |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, ≥99.99% filter efficiency) |
| Noise Level | ≤67 dB(A) |
| User Configuration | Single-user, single-frontal workface |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Work Area Dimensions (W×D×H) | 910 × 480 × 570 mm |
| Overall Dimensions (W×D×H) | 910 × 790 × 1380 mm |
| HEPA Filter Specification | 815 × 575 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Illumination | ≥300 lx (20 W fluorescent lamp) |
| UV Germicidal Lamp | 20 W, timer-controlled (0–999 min) |
| Operating Wind Speed Range | 0.3–0.6 m/s (6-step adjustable) |
| Vibration Peak-to-Peak | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 0.15 kW |
| Net Weight | 110 kg |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | SW-CJ-1CU |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-user, single-face configuration |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Work Surface Velocity Range | 0.3–0.6 m/s (adjustable in six discrete steps) |
| Vibration Amplitude (peak-to-peak) | ≤10 µm (X/Y/Z axes) |
| Illumination | ≥300 lux (measured at work surface) |
| Work Area Dimensions (W×D×H) | 1570 × 480 × 570 mm |
| Overall Dimensions (W×D×H) | 1570 × 790 × 1380 mm |
| HEPA Filter Specifications | Two units — 600 × 575 × 50 mm and 815 × 575 × 50 mm |
| Pre-filter | Medium-efficiency panel filter |
| Lighting | One 40 W fluorescent lamp |
| UV Germicidal Lamp | One 40 W low-pressure mercury lamp with 0–999 min programmable timer |
| Control Interface | LCD display with tactile membrane switches |
| Construction Materials | Cold-rolled steel housing with epoxy powder coating |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power Consumption | 0.3 kW |
| Net Weight | 200 kg |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SW-CJ-1CU |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, ≥99.99% filter efficiency) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-user, single-front configuration |
| Airflow Pattern | Horizontal laminar flow |
| Working Surface Wind Speed | 0.3–0.6 m/s (adjustable in six steps) |
| Vibration Peak-to-Peak | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lx |
| Work Area Dimensions (W×D×H) | 1570 × 480 × 570 mm |
| Overall Dimensions (W×D×H) | 1570 × 790 × 1380 mm |
| HEPA Filter Specifications | 600 × 575 × 50 mm (1 pc) + 815 × 575 × 50 mm (1 pc) |
| UV Lamp & Fluorescent Lamp | 40 W × 1 each |
| Net Weight | 200 kg |
| Power Consumption | 0.3 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SW-CJ-1F |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-grade, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-operator, dual-front access |
| Airflow Pattern | Vertical downward laminar flow |
| Working Area Air Velocity | 0.3–0.6 m/s (adjustable in six steps) |
| Vibration Peak-to-Peak | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lux |
| Working Chamber Dimensions (W×D×H) | 870 × 700 × 520 mm |
| Overall Dimensions (W×D×H) | 990 × 724 × 1650 mm |
| HEPA Filter Specification | 820 × 615 × 50 mm × 1 unit |
| Pre-filter | Medium-efficiency panel filter |
| UV Lamp | 20 W × 1 (timer-controlled, 0–999 min) |
| Fluorescent Lamp | 20 W × 1 |
| Net Weight | 110 kg |
| Power Consumption | 0.15 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |