| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACM-200+ |
| Pricing | Available Upon Request |
| Brand | Active Spectrum |
|---|---|
| Origin | USA |
| Model | CM-1000 |
| Measurement Principle | Dual-wavelength (700 nm & 840 nm) reflectance-based relative chlorophyll index |
| Measurement Area | 1.35 cm Ø at 30.5 cm distance |
| Effective Measurement Range | 0–999 (unitless relative chlorophyll index) |
| Repeatability | ±5% of reading |
| Measurement Interval | 2 seconds per reading |
| Detector | Four photodiodes (2 for sample reflectance, 2 for ambient light compensation) |
| Data Storage | 1,350 records with GPS metadata |
| Power | Two AAA alkaline batteries (~3,000 measurements per set) |
| Operating Distance Range | 30.5 cm to 183 cm |
| Weight | Handheld, lightweight ergonomic design |
| Environmental Compensation | Automatic ambient light correction |
| Connectivity | Optional GPS integration via serial interface |
| Compliance | Designed for field-deployable agronomic and ecological monitoring in accordance with ISO 11097 (optical plant sensors), ASTM E2912 (standard practice for spectral reflectance measurements of vegetation), and GLP-aligned data integrity workflows |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | AM-350 |
| Measurement Width | 103 mm |
| Maximum Sample Length | 2 m |
| Scanning Speed | up to 20 mm/sec |
| Linear Accuracy | ±1% |
| Area Accuracy | ±2% |
| Perimeter Accuracy | ±5% |
| Resolution | 0.065 mm² |
| Memory | 256 KB RAM (stores up to 2,000 datasets) |
| Display | 64 × 240 pixel LCD |
| Rechargeable Battery | 12 V, 1.2 Ah (enables ~3,000 field scans) |
| Operating Temperature | 0–45 °C |
| Dimensions | 275 × 250 × 30 mm |
| Weight | 1.8 kg |
| Output Formats | BMP, TIFF |
| Interface | USB |
| Measured Parameters | leaf area, cumulative area, mean area, diseased area, length, width, perimeter, length-to-width ratio, shape factor (4πA/P², where A = area, P = perimeter) |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AM350 Portable Leaf Area Meter |
| Price | Upon Request |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | APS Multi-Channel |
| Configuration Options | 5-channel or 10-channel modular system |
| Gas Exchange Measurement Principle | Infrared Gas Analysis (IRGA) with integrated multi-port gas multiplexer |
| Leaf Chamber Interface | Detachable, independently controlled cuvettes connected via extended pneumatic tubing and signal cables |
| Compliance | Designed for GLP-compliant environmental physiology studies |
| Software Platform | APS Control Suite with audit trail, timestamped raw data export (CSV/NetCDF), and optional FDA 21 CFR Part 11–ready configuration |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | iFL Portable |
| Pricing | Available Upon Request |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCi T |
| CO₂ Range | 0–2000 ppm (0.1 ppm resolution, ±1% accuracy, 0.25 s response) |
| H₂O Range | 0–75 mbar (0.1 mbar resolution, 0.5% RH repeatability) |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (silicon photodiode, ±5 µmol·m⁻²·s⁻¹) |
| LED Light Sources | RGB (0–2400 µmol·m⁻²·s⁻¹) or White (0–2500 µmol·m⁻²·s⁻¹) |
| Leaf Chamber Temp | −5 to 50 °C (±0.2 °C) |
| Airflow | 100–500 mL/min (±2% FS) |
| Battery Life | ~10 h (12 V, 2.8 Ah sealed lead-acid) |
| Weight | 2.4 kg (main unit), 0.6 kg (standard chamber) |
| Dimensions | 240 × 125 × 140 mm (unit) |
| Data Storage | Removable SD card (up to 32 GB) |
| Compliance | ASTM E2912-13 (gas exchange instrumentation), ISO 17025 traceable calibration protocols, GLP-compliant data logging with timestamp, GPS geotagging (latitude/longitude/elevation) |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCi-T |
| CO₂ Measurement Range | 0–2000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Measurement Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Leaf & Chamber Temperature Range | −5 to 50 °C |
| Accuracy | ±0.2 °C |
| Airflow Rate | 68–340 mL/min |
| Flow Accuracy | ±2% of full scale |
| Preheat Time | 5 min at 20 °C |
| Data Storage | SD card (up to 32 GB, 16 million data points) |
| Display | 480 × 272-pixel color WQVGA touchscreen (95 × 53.9 mm) |
| Weight | 2.4 kg |
| Dimensions | 240 × 125 × 140 mm |
| Battery Life | ~10 h (12 V / 2.8 Ah lead-acid) |
| Operating Environment | 5–45 °C |
| GPS | Integrated |
| IRGA Type | Differential open-path, auto-zeroing with pressure & temperature compensation |
| H₂O Sensor | Dual-laser tunable diode absorption spectroscopy (TDLAS) |
| Fluorescence Module (optional) | Supports F₀, Fₘ, Fₘ′, QY_Ln, NPQ, OJIP-test (26 parameters), 100 kHz sampling rate |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T Intelligent Photosynthesis System |
| CO₂ Range | 0–2000 ppm |
| H₂O Control Range | 0–75 mbar |
| PAR Source | Adjustable RGB or White LED (0–2400 µmol·m⁻²·s⁻¹) |
| Temperature Control | Peltier-based (ΔT = +15 °C / −10 °C vs. ambient or ambient-follow mode) |
| GPS | Integrated with UTC time, latitude/longitude, and altitude logging |
| Humidity Sensors | Dual high-precision laser-trimmed capacitive sensors |
| IRGA Design | Gold-coated, miniaturized, time-domain differential dual-beam NDIR for drift-free CO₂ measurement |
| Leaf Chamber Climate Control | Simultaneous closed-loop regulation of CO₂, H₂O, PAR, and temperature |
| Battery Life | Up to 16 h (Li-ion) |
| Weight | Control Unit 4.1 kg, Measurement Unit 0.8 kg |
| Data Storage | SD card + USB interface |
| Fluorescence Integration | Direct hardware synchronization with FluorCam and portable chlorophyll fluorometers |
| Compliance | Designed for GLP-aligned field data acquisition |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T Portable Photosynthesis System |
| CO₂ Measurement Range | 0–3000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Measurement Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (cosine-corrected) |
| Leaf/Chamber Temperature Range | −5 to 50 °C (±0.2 °C accuracy) |
| Airflow Rate | 100–500 mL·min⁻¹ |
| CO₂ Control | Up to 2000 ppm via internal supply |
| H₂O Control | Humidity adjustable above/below ambient |
| Temperature Control | Peltier-based, ±15 °C offset from ambient |
| PAR Control | White LED up to 2500 µmol·m⁻²·s⁻¹ |
| Weight | 4.1 kg (main unit), 0.8 kg (handheld sensor handle) |
| Battery Life | Up to 16 h (12 V, 7.5 Ah Li-ion) |
| Display | 95 × 53.9 mm WQVGA color touchscreen (80 × 272 px) |
| Data Storage | Removable SD card (up to 32 GB) |
| Communication | Mini-B USB + RS232 (max. 230,400 baud) |
| Operating Environment | 5–45 °C, high-humidity/dusty conditions supported |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T |
| CO₂ Measurement Range | 0–3000 ppm (±1% accuracy, 0.1 ppm resolution, dual-beam IRGA) |
| H₂O Measurement Range | 0–75 mbar (0.1 mbar resolution, dual-laser tunable hygrometer) |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (cosine-corrected Si photodiode, ±5 µmol·m⁻²·s⁻¹) |
| Leaf & Chamber Temperature | −5 to 50 °C (±0.2 °C) |
| Air Flow Rate | 100–500 mL·min⁻¹ (±2% FS) |
| Response Time (CO₂) | 0.25 s |
| Auto-Zero Cycle | 4 s |
| Battery Life | Up to 16 h (12 V, 7.5 Ah Li-ion) |
| Weight | 4.1 kg (main unit), 0.8 kg (handle) |
| Dimensions | 230 × 110 × 170 mm (unit), 300 × 80 × 75 mm (handle) |
| Data Storage | Removable SD card (up to 32 GB) |
| Environmental Operating Range | 5–45 °C |
| Optional Leaf Chambers | Broadleaf (6.25 cm²), Narrowleaf (5.2 cm²), Conifer (175 cm³), Arabidopsis/Small-Leaf (16 mm Ø), Mini-Canopy (≤55 mm height), Whole-Plant Arabidopsis, Fruit Chamber (1 L), Soil Respiration Chamber (1 L), Fluorescence Adapter (compatible with OS-5p) |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PTA |
| Pricing | Available Upon Request |
| Brand | AgriPheno |
|---|---|
| Origin | Shanghai, China |
| Model | PhenoWatch |
| Type | Modular Mobile 3D Phenotyping Platform |
| Imaging Modalities | LiDAR + Hyperspectral + Thermal IR + Multispectral + RGB |
| Axes Control | X-Y-Z Automated Positioning |
| Compliance | Designed for GLP-aligned phenotypic data acquisition in agronomic and genetic research |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | MC-100 |
| Measurement Principle | Dual-wavelength (653 nm & 931 nm) transmittance ratio |
| Display Units | μmol/m² (default), CCI, SPAD |
| Measurement Area | 63.6 mm² (9.0 mm diameter), 19.6 mm² (with optional shade hood for leaves <5 mm wide) |
| Resolution | ±10 μmol/m² (typical plants), 0.1 CCI |
| Linearity | ±1% |
| Repeatability | ±1% |
| Measurement Time | <3 s |
| Data Storage | 8 MB (up to 160,000 measurements |
| Interface | Mini-B USB, RS-232 (GPS-compatible) |
| Display | 50 mm × 15 mm graphical LCD, 8-button navigation |
| Operating Temperature | 0–50 °C |
| Power | 9 V alkaline battery |
| Auto-shutdown | After 4 min of inactivity or no data download |
| Dimensions | 152 × 82 × 25 mm |
| Weight | 210 g |
| Brand | Argus |
|---|---|
| Origin | Germany |
| Model | PiCUS-3 |
| Sensor Count | 6 or 12 |
| Sensor Cable Length | 3.5 m |
| Measurement Principle | Elastic Wave Propagation Time-of-Flight Tomography |
| Spatial Resolution | 1 µs time resolution |
| Operating Battery Life | >6 h |
| Charging Time | 2 h |
| GPS Accuracy | 0–20 m |
| Display | Color LCD (real-time tomographic visualization) |
| Data Transfer | USB 2.0 or Bluetooth (range: 0.5–10 m) |
| Dimensions | 55 × 42 × 13 cm |
| Weight | 8.9 kg |
| Integrated Height Measurement | Yes |
| Optional Electronic Caliper Range | 160–2150 mm (stainless steel) |
| Brand | Argus |
|---|---|
| Origin | Germany |
| Model | TMS3 |
| Weight | 73 g |
| Dimensions | 61 mm × 41 mm × 20 mm |
| IP Rating | Fully Sealed, Waterproof & Dustproof |
| Tilt Measurement Accuracy | ±0.03° |
| Sampling Frequency | 20 Hz (50 ms interval) |
| Measurement Axes | 3D (X/Y/Z, cardinal directions) |
| Operating Temperature Range | −20 °C to +50 °C |
| Battery Capacity | 250 mAh |
| Continuous Operation | >15 days |
| Charging | Wireless (Qi-compatible) |
| Data Storage | 256 MB (≈20 days at 20 Hz) |
| Communication | Bluetooth 2.1 |
| Sensor Mounting | Omnidirectional |
| Control Sensor Height | 2–3 m above ground |
| Base Sensor Placement | At root collar / anchorage zone |
| Brand | AZ (Beijing Aozuo) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | EcoScope |
| Price | USD 145 (approx. based on ¥1000 at 1:6.9 exchange rate) |
| Brand | AZ (Beijing Aozuo Ecological Instruments Co., Ltd.) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ENVILog-Kc |
| Price | USD 1,400 (approx. based on ¥10,000 at 1 USD ≈ ¥7.15) |
| Brand | AZO (Beijing AoZuo) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Rhizoscope |
| Price Range | USD 56,000 – 140,000 |
| Brand | AZ (Beijing Aozuo) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | AZR-300PLUS |
| Power Supply | 12 V rechargeable battery (≥6 h operation) |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–100% RH (non-condensing) |
| Camera Resolution | 3840 × 2880 pixels (adjustable) |
| Field of View | 20 × 16 mm |
| Probe Dimensions | 36 cm × 6.2 cm (L × Ø) |
| Root Tube ID | 50 mm |
| length options | 1 m or 2 m |
| TDR Soil Moisture Range | 0–100% volumetric water content |
| EC Accuracy | ±2% (0–40% VWC), ±3% (40–70% VWC) |
| EC range | 0–15 dS/m |
| Vacuum Sampling Pressure | 0 to −85 kPa |
| Sampling Tube Lengths | 20, 40, 50, 100, 200 cm |
| Sampling Head | Ø22 mm × 60 mm |
| Brand | Azure Cloud & Wind Confluence |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FluorV100 Chlorophyll Fluorescence Imaging System |
| CMOS Resolution | 4096 × 3072 |
| Frame Rate | 150 fps (8-bit), 60 fps (12-bit) |
| Imaging Area | 156 mm × 157 mm (Working Distance = 100 mm) |
| Modulated Actinic Light Intensity | 0.1–100% of 0.1 µmol·m⁻²·s⁻¹ |
| Actinic Light Intensity | 100–800 µmol·m⁻²·s⁻¹ (10–100% adjustable) |
| Saturating Pulse Intensity | 4000 µmol·m⁻²·s⁻¹ (10–100% adjustable) |
| Fluorescence Parameters | Fo, Fm, Fp, Fv, Fm_L[N], Fm_D[N], Fm_Lss, NPQ_L[N], NPQ_D[N], NPQ_Lss, Qp_L[N], Qp_D[N], QYmax, QY_L[N], QY_D[N] |
| Brand | Azure Cloud & Wind Confluence |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-T10 Stemflow Collector and Data Logger |
| Measurement Range | 0–66,000 mL |
| Resolution | 4 mL |
| Memory Capacity | 16,000 data points |
| Data Download | Infrared interface + USB port |
| Memory Type | EEPROM (non-volatile) |
| Enclosure | Fully sealed, weatherproof housing for field deployment on tree trunks or in forest understory |
| LED Status Indicator | Integrated visual status feedback |
| Battery Life | ~12 months (typical field use) |
| Event Time Resolution | 1 second |
| Temperature Sensing Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Real-Time Clock Accuracy | ±1 minute per week |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | JTS-150 |
| Excitation & Detection Wavelength Range | 320–1120 nm |
| Detector | Si PIN Photodiode |
| Optical Density (OD) Sensitivity | 1×10⁻⁵ OD (OD 0–2 range) |
| Time Resolution | 10 µs to minutes |
| Optional Flash Sources | Laser or Xenon Flash Lamp |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CI-203 |
| Pricing | Upon Request |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN_G30 |
| Key Specifications | 180° fisheye lens |
| Image Resolution | 2592 × 1944 |
| PAR Spectral Range | 400–700 nm |
| PAR Measurement Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Angular Coverage | Zenith angle 0°–90° (hemispherical), subdivided into 10 zenith zones & 10 azimuth zones |
| Operating Temperature | −10°C to 55°C |
| Relative Humidity | ≤85% RH |
| Weight | 500 g |
| Interface | USB |
| Software | COMECAUSE Canopy Analysis System v3.x |
| GPS Integration | Real-time geotagging (latitude/longitude) |
| Data Output | Cloud-sync capable (secure agricultural cloud platform) |
| Language Support | Switchable bilingual UI (English/Chinese) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | IN_GD20 |
| Price | USD 5,300 (FOB Qingdao) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | IN_GX01 |
| Imaging Sensor | 20 MP Auto-Focus Color Camera |
| Max Analysis Area | 297 mm × 210 mm |
| Minimum Resolvable Root Diameter | ≥ 0.5 mm |
| Output Formats | CSV, Excel (.xlsx), PNG/JPEG with Annotation Layers |
| Software Interface | Windows 10 Professional/Enterprise (64-bit) |
| Cloud Sync | Integrated Secure Web Portal |
| Language Support | English & Chinese (Switchable) |
| Compliance | Designed for GLP-aligned workflows |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN_GX02 |
| Optical Resolution | 4800 × 9600 dpi (A4+ extended) |
| Scan Area (Reflective) | 355.6 mm × 215.9 mm |
| Scan Area (Transmissive) | 320.0 mm × 203.2 mm |
| Minimum Pixel Size | 0.005 mm × 0.0026 mm |
| Light Source | Dual Cold Cathode Fluorescent Lamp (CCFL) Illumination System |
| Image Formats Supported | TIFF, JPEG |
| Software Interface | USB 2.0, Windows 10 Professional/Ultimate (64-bit), Dual-Language (English/Chinese) |
| Cloud Data Sync Capability | Yes |
| Compliance | ASTM D7250 (for image-based dimensional analysis), ISO/IEC 17025-aligned data traceability architecture |
| Brand | COMECAUSE |
|---|---|
| Model | IN_LeafClear |
| Camera Resolution | 1608 × 1104 |
| Pixel Size | 9 µm × 9 µm |
| Frame Rate | 100 fps |
| Bit Depth | 12-bit |
| Interface | USB 3.0 |
| Lens Focal Length | 12 mm |
| Max Aperture | F/2.8 (adjustable) |
| HFOV | 62.11° |
| VFOV | 44.83° |
| Max Imaging Area | 50 cm × 35 cm |
| Excitation Wavelengths | 450 nm (blue), 630 nm (red), 730 nm (far-red) |
| LED Intensity Range | 1–100% (up to 1440 µmol·m⁻²·s⁻¹) |
| OJIP Acquisition Time | 0.1–1.0 s (min Δt = 10 ms) |
| PAM Sampling Interval | 0.1–10.0 s (min Δt = 100 ms) |
| Fluorescence Dynamic Range | 0–4095 (12-bit), SNR > 100:1, Repeatability CV < 3%, Linearity R² > 0.999 |
| Spatial Resolution | ~0.3 mm/pixel at standard working distance |
| Parameter Accuracy | Fv/Fm ±0.005, ΦPSII ±0.01, qP/qN ±0.02, NPQ ±0.1, PIABS ±0.05 |