High Pressure Sterilizer
Filter
Showing 1–30 of 141 results
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Model | RSS-L1 |
| Type | Benchtop Sterilizer |
| Max Temperature | 0–150 °C (±0.1 °C) |
| Chamber Volume Capacity | 10–2000 mL |
| Max Working Pressure | 0.3 MPa |
| Total Power | 7.5 kW |
| Sample Capacity | 1–10 vessels |
| Temperature Sensors | ≥3 independent RTD probes |
| Output Parameters | Temperature, Pressure, F₀, Time, Rotation Speed, Steam Flow (where applicable) |
| Brand | ALP |
|---|---|
| Origin | Japan |
| Model | CL-32L / CL-40M |
| Chamber Volume | 54 L (CL-32L), 85 L (CL-40M) |
| Max Operating Temperature | 140 °C (CL-32L), 137 °C (CL-40M) |
| Max Working Pressure | 0.27 MPa (CL-32L), 0.25 MPa (CL-40M) |
| Sterilization Temp Range | 40–140 °C (CL-32L), 40–137 °C (CL-40M) |
| Melting/Insulation Range | 40–99 °C / 40–60 °C |
| Cycle Time | Sterilization/Melting: 0–600 min or continuous |
| Insulation | 0–2880 min |
| Drying Temp Range | 60–180 °C |
| Drying Timer | 0–5940 min or continuous |
| Control System | Microprocessor-based with graphical LCD interface |
| Safety Compliance | ASME BPVC Section VIII Div. 1, PED 2014/68/EU, ISO 17665-1, GB/T 30690–2014, China Special Equipment Manufacturing License (Pressure Vessel) |
| Brand | ALP |
|---|---|
| Origin | Japan |
| Model | CLG-32L / CLG-40M |
| Chamber Dimensions (Ø × Depth) | 320 × 676 mm (32L) / 400 × 672 mm (40M) |
| Chamber Volume | 54 L / 85 L |
| Sterilization Temp Range | 100–140 °C (CLG-32L), 100–137 °C (CLG-40M) |
| Dissolution/Heating Temp Range | 40–99 °C / 40–60 °C |
| Max Operating Pressure | 0.270 MPa / 0.250 MPa |
| Cycle Time | Sterilization/Dissolution: 0–10 h |
| Holding | 0–48 h |
| Programmable Cycles | 10 stored protocols with mode & data logging |
| Vacuum System | Triple-pulse pre-vacuum with high-capacity vacuum pump |
| Air Filtration | 0.2 µm hydrophobic filter for heated air drying |
| Drying Method | Vacuum-assisted hot-air drying post-sterilization |
| Safety Certification | PED 97/23/EC compliant |
| Construction | Inner chamber – SUS304 stainless steel |
| Power Supply | AC 220–240 V, 1-phase, 50/60 Hz |
| Rated Current | 12 A |
| Heating Power | 2.6 / 2.8 / 2.9 kW (model-dependent) |
| Dimensions (W×D×H) | 550 × 550 × 950 mm (CLG-32L) / 620 × 650 × 990 mm (CLG-40M) |
| Weight | 65 kg / 83 kg |
| Control Interface | Backlit LCD display with real-time monitoring of temperature, pressure, phase status, and elapsed time |
| Door Mechanism | Central lever lock with automatic interlock, motor-assisted hinge, and power-dependent electronic safety lock |
| Cooling | Active rapid cooling to <80 °C post-cycle |
| Drainage | Front-mounted manual drain valve and accessible front-positioned waste tank |
| Optional | Integrated product temperature probe port (probe sold separately) |
| Compliance | Meets IEC 61000-6-3 (EMC) and IEC 61000-6-4 (emission) standards |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MVS-3780 |
| Chamber Dimensions (Ø × H) | 370 mm × 795 mm |
| Chamber Volume | 83 L |
| External Dimensions (W × D × H) | 550 × 550 × 1050 mm |
| Net Weight | 83 kg |
| Power Rating | 3100 W |
| Electrical Interface | 16 A plug |
| Safety Compliance | Dual dry-run protection, overcurrent & leakage protection, pressure relief valve, four-point interlock system, chamber overpressure alarm, 98% air removal efficiency |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MVS-60 |
| Sterilization Chamber Dimensions | Φ370 × 610 mm |
| External Dimensions | 550 × 550 × 820 mm |
| Chamber Volume | 55 L |
| Vessel Material | S30408 stainless steel (GB/T 24511–2017), 3 mm wall thickness |
| Design Standard | GB 150–2011 |
| Altitude Rating | Certified for operation up to 4000 m ASL |
| Safety Features | Dual dry-run protection, overcurrent protection, earth-leakage detection, four-point interlocked door system, spring-loaded safety valve, real-time overpressure alarm |
| Exhaust System | Pressure-stabilized air removal (98% air displacement), six-stage adjustable exhaust rate & temperature |
| Cooling | High-capacity external cooling fan (optional internal fan), variable-speed cooling control |
| Control Modes | Four pre-programmed cycles + user-defined program memory + pre-heating cycle + time-scheduled start |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MVS-83 |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 135 °C |
| Max Pressure | 0.3 MPa |
| Chamber Dimensions (W×H) | 370 mm × 795 mm |
| External Dimensions (W×D×H) | 600 mm × 620 mm × 1005 mm |
| Chamber Volume | 83 L (≥75 L effective) |
| Power Rating | 4200 W |
| Net Weight | 90 kg |
| Safety Class | Class I Pressure Vessel |
| Manufacturing License | DI-Class |
| Temperature Sensor | PT100 |
| Pressure Gauge Range | −0.1 to 0.5 MPa |
| Safety Valve Set Point | 0.28 MPa |
| Cooling System | Dual-Cooling (axial + shaded-pole fans + condenser) |
| Exhaust | Adjustable 5-level downward exhaust |
| Operating Altitude Range | 0–3000 m |
| Timer Range | 0–4320 min (1 min resolution) |
| Brand | Alphavita |
|---|---|
| Model | MVS-84 |
| Chamber Volume | 83 L |
| External Dimensions (W×D×H) | 600 × 620 × 1005 mm |
| Internal Dimensions (Ø × H) | Ø370 × 795 mm |
| Net Weight | 100 kg |
| Power Rating | 3100 W |
| Construction Material | S30408-2B stainless steel (3 mm thickness) |
| Compliance | YY/T 1007–2018, GB 150, GB/T 24511–2017 |
| Safety Features | Dual dry-run protection, overcurrent protection, earth leakage protection, quadruple mechanical/electrical interlock, spring-loaded safety valve, chamber overpressure alarm |
| Operating Altitude | Up to 4000 m ASL |
| Power Interface | 16 A standard plug |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGM-90FE |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.24 MPa |
| Chamber Dimensions | Ø380 mm × 735 mm |
| External Dimensions | 605 mm × 513 mm × 1040 mm |
| Chamber Volume | 90 L |
| Design Pressure | 0.39 MPa |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ≤1 °C |
| Temperature Fluctuation | ±1 °C |
| Sterilization Time Range | 0–240 min |
| Melting/Insulation Time Range | 0–6000 min |
| Power Input | 3.6 kW |
| Operating Ambient | 5–40 °C, 20–80% RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-100M |
| Instrument Type | Vertical Steam Sterilizer |
| Maximum Temperature | 135 °C |
| Maximum Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 870 mm |
| External Dimensions | 750 × 800 × 1180 mm |
| Chamber Volume | 100 L |
| Heating Power | 6.8 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80 % RH |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BXM-100M |
| Instrument Type | Vertical Sterilizer |
| Max Temperature | 135°C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 870 mm |
| External Dimensions | 750 × 800 × 1180 mm |
| Chamber Volume | 100 L |
| Temperature Range (Sterilization) | 105–135°C |
| Temperature Range (Drying) | 102°C |
| Temperature Range (Melting) | 40–100°C |
| Temperature Range (Heating/Insulation) | 25–85°C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying) | 0–999 min |
| Time Range (Melting/Insulation) | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 6.8 kW |
| Power Supply | ~220 V ±22 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40°C, 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Cooling Method | Integrated Axial Fan (Forced Air) |
| Air Intake Filtration | Built-in HEPA-grade Filter |
| Water Supply | Dual-channel (Deionized/Pure Water & Tap Water) |
| Standard Probe | Single-channel Sample Temperature Sensor |
| C.W.S. Condensate Reuse System | Yes |
| W.P.S. Waste Gas & Effluent Purification System | Yes |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-110EI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 535 × 640 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | +1 °C |
| Sterilization Temp Range | 105–135 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Melting/Holding Time Range | 0–6000 min |
| 预约 Time | Up to 100 h |
| Heating Power | 3.5 kW |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Operating Ambient | 5–40 °C, 20–80 % RH |
| Cooling System | Standard air-cooling + secondary water-cooling + condenser |
| Safety Protections | Overtemperature cutoff, dry-run protection, overpressure mechanical & electronic relief, anti-scald insulation, overload, short-circuit, and leakage protection |
| User Access Levels | Engineer / Administrator / Operator (3-tier permission management) |
| Programmability | 8 pre-set + 6 user-defined cycles |
| Air Removal | 6-stage positive-pressure pulse with adjustable vacuum-assisted preheating |
| Exhaust Control | 6-level programmable depressurization rate |
| Optional Accessories | 0.2 µm high-temp/pressure exhaust filter, thermal printer with F₀ logging capability (requires optional sample probe), validation port adapter, wired temperature validation interface |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-110FI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 585 × 750 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (extendable to 6000 min) |
| Drying Temp Range | 80–130 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Drying Duration | 10–6000 min |
| Power Input | 5.4 kW |
| Voltage | 220 V ± 10 %, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80 % RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-110VE |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 535 × 640 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Temp Range | 105–135 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Melting/Holding Time Range | 0–6000 min |
| 预约 Function | Up to 100 h |
| Heating Power | 3.5 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Operating Ambient | 5–40 °C, 20–80% RH |
| Cooling System | Standard air-cooling + secondary water-cooling + condenser |
| Safety Protections | Overtemperature shutdown, low-water cutoff, overpressure mechanical relief, independent electronic overpressure sensor, anti-scald insulation, overload protection, short-circuit protection, earth leakage protection |
| User Access Levels | Engineer / Administrator / Operator (3-tier permission management) |
| Interface | Capacitive touchscreen, RS-485 ×2, G1/2A calibration port, waterproof socket ×1 |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-120M |
| Instrument Type | Vertical |
| Max Temperature | 135°C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 740 mm |
| External Dimensions | 850 × 910 × 1080 mm |
| Chamber Volume | 120 L |
| Temperature Range (Sterilization) | 105–135°C |
| Temperature Range (Drying) | 102°C |
| Temperature Range (Melting) | 40–100°C |
| Temperature Range (Heating/Insulation) | 25–85°C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying/Melting/Insulation) | 0–999 min |
| Pre-set Delay | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Efficiency | <1% residual moisture |
| Heating Power | 9.9 kW |
| Power Supply | ~380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40°C, 20–80% RH |
| Chamber & Basket Material | SUS304 stainless steel |
| Cooling Method | Forced-air cooling with built-in fan |
| Air Intake Filtration | Integrated HEPA-grade air filter |
| Dual Water Inlet System | Selectable pure water or tap water supply |
| Standard Sample Temperature Probe | Real-time monitoring of load temperature |
| C.W.S. Condensate Water Reuse System | Recirculates sterilization condensate |
| W.P.S. Waste Processing System | Filters and purifies exhaust steam and condensate prior to discharge |
| Safety Features | Mechanical self-locking + electronic interlock door mechanism, overtemperature cutoff, independent safety limiter, overpressure auto-relief, fault self-diagnosis, water-level auto-refill |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BXM-120M |
| Instrument Type | Vertical Sterilizer |
| Max Operating Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 740 mm |
| External Dimensions | 850 × 910 × 1080 mm |
| Chamber Volume | 120 L |
| Temperature Range (Sterilization) | 105–135 °C |
| Temperature Range (Drying) | 102 °C |
| Temperature Range (Melting) | 40–100 °C |
| Temperature Range (Heating/Insulation) | 25–85 °C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying/Melting/Insulation) | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 9.9 kW |
| Power Supply | 380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-150M |
| Instrument Type | Vertical Steam Sterilizer |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 870 mm |
| External Dimensions | 850 × 910 × 1180 mm |
| Chamber Volume | 150 L |
| Sterilization Temp Range | 105–135 °C |
| Drying Temp Range | 102 °C |
| Melting Temp Range | 40–100 °C |
| Holding Temp Range | 25–85 °C |
| Sterilization Time Range | 4–120 min |
| Drying Time Range | 0–999 min |
| Melting/Holding Time Range | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 10.5 kW |
| Power Supply | 380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-150M |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 870 mm |
| External Dimensions | 850 × 910 × 1180 mm |
| Chamber Volume | 150 L |
| Temperature Range (Sterilization) | 105–135 °C |
| Temperature Range (Drying) | 102 °C |
| Temperature Range (Melting) | 40–100 °C |
| Temperature Range (Warming/Insulation) | 25–85 °C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying/Melting/Insulation) | 0–999 min |
| Pre-set Delay | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 10.5 kW |
| Power Supply | 380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BXM-30R |
| Instrument Type | Vertical |
| Maximum Temperature | 126 °C |
| Maximum Pressure | 0.14 MPa |
| Chamber Dimensions | Φ300 × 420 mm |
| External Dimensions | 395 × 395 × 780 mm |
| Chamber Volume | 29 L |
| Power Rating | 2 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating/Design Temp. | 126 °C / 128 °C |
| Operating/Design Pressure | 0.14 MPa / 0.165 MPa |
| Timer Range | 0–120 min |
| Basket Dimensions | Φ280 × 340 mm (1 unit) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BXM-30R |
| Instrument Type | Vertical Sterilizer |
| Maximum Temperature | 126 °C |
| Maximum Pressure | 0.14 MPa |
| Chamber Dimensions | Φ300 × 420 mm |
| External Dimensions | 395 × 395 × 780 mm |
| Chamber Volume | 29 L |
| Power Rating | 2 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating/Design Temperature | 126 °C / 128 °C |
| Operating/Design Pressure | 0.14 MPa / 0.165 MPa |
| Timer Range | 0–120 min |
| Basket Dimensions | Φ280 × 340 mm (1 unit) |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-50M |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 520 mm |
| External Dimensions | 750 × 800 × 950 mm |
| Chamber Volume | 50 L |
| Sterilization Temp Range | 105–135 °C |
| Drying Temp | 102 °C |
| Melting Temp Range | 40–100 °C |
| Holding Temp Range | 25–85 °C |
| Sterilization Time | 4–120 min |
| Drying Time | 0–999 min |
| Melting/Holding Time | 0–999 min |
| Delay Start | up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 5.1 kW |
| Supply Voltage | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Temp | 5–40 °C |
| Ambient Humidity | 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BXM-50M |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 520 mm |
| External Dimensions | 750 × 800 × 950 mm |
| Chamber Volume | 50 L |
| Temperature Range (Sterilization) | 105–135 °C |
| Temperature Range (Drying) | 102 °C |
| Temperature Range (Melting) | 40–100 °C |
| Temperature Range (Heating/Insulation) | 25–85 °C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying/Melting/Insulation) | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 5.1 kW |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-60EI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 635 mm |
| External Dimensions | 535 × 640 × 1075 mm |
| Chamber Volume | 60 L |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BXM-60FI |
| Instrument Type | Vertical Sterilizer |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 635 mm |
| External Dimensions | 585 × 750 × 1075 mm |
| Chamber Volume | 60 L |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (extendable to 6000 min) |
| Drying Temp Range | 80–130 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Drying Time Range | 10–6000 min |
| Power Input | 4.8 kW |
| Voltage | 220 V ± 10 %, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80 % RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-60VF |
| Instrument Type | Vertical Steam Sterilizer |
| Maximum Temperature | 150 °C |
| Maximum Working Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 635 mm |
| External Dimensions | 585 × 750 × 1075 mm |
| Chamber Volume | 60 L |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (extendable to 6000 min) |
| Drying Temperature Range | 80–130 °C |
| Melting/Soaking Range | 50–100 °C |
| Holding Range | 40–60 °C |
| Power Input | 4.8 kW |
| Voltage | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-75M |
| Instrument Type | Vertical |
| Max Temperature | 135°C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 700 mm |
| External Dimensions | 750 × 800 × 1080 mm |
| Chamber Volume | 75 L |
| Sterilization Temp Range | 105–135°C |
| Drying Temp Range | 102°C |
| Melting Temp Range | 40–100°C |
| Holding Temp Range | 25–85°C |
| Sterilization Time | 4–120 min |
| Drying Time | 0–999 min |
| Melting/Holding Time | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 5.9 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40°C, 20–80% RH |
| Chamber & Basket Material | SUS304 stainless steel |
| Cooling Method | Forced-air rapid cooling |
| Air Intake Filtration | Built-in HEPA-grade filter |
| Dual Water Inlet System | Selectable pure water or tap water |
| Condensate Recycling System (C.W.S.) | Integrated |
| Waste Gas & Effluent Purification System (W.P.S.) | Integrated |
| Standard Sample Temperature Probe | Yes |
| Data Logging & Export | Yes |
| Safety Features | Mechanical self-locking + electronic interlock door, overtemperature cutoff, independent safety limiter, overpressure relief valve, fault self-diagnosis |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-75M |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 700 mm |
| External Dimensions | 750 × 800 × 1080 mm |
| Chamber Volume | 75 L |
| Temperature Range (Sterilization) | 105–135 °C |
| Temperature Range (Drying) | 102 °C |
| Temperature Range (Melting) | 40–100 °C |
| Temperature Range (Heating/Insulation) | 25–85 °C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying/Melting/Insulation) | 0–999 min |
| Pre-set Delay | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 5.9 kW |
| Power Supply | AC 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Cooling Method | Forced-air rapid cooling |
| Air Intake Filtration | Built-in HEPA-grade filter |
| Water Supply | Dual-channel automatic fill (deionized water & tap water) |
| Standard Probe | Single-channel sterilization load temperature sensor |
| CWS System | Condensate Water Reuse System |
| WPS System | Waste Water & Vapor Purification System |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-85BE |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.212 MPa |
| Chamber Dimensions | Ø380 × 765 mm |
| External Dimensions | 550 × 588 × 1040 mm |
| Chamber Volume | 85 L |
| Temperature Uniformity | ≤1 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–240 min |
| Melting Time Range | 0–600 min |
| Holding Time Range | Up to 24 h |
| Delayed Start Timer | Up to 99 h 59 min |
| Design Pressure | 0.28 MPa |
| Heating Power | 3.6 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-85EI |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 725 mm |
| External Dimensions | 535 × 640 × 1165 mm |
| Chamber Volume | 85 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Melting/Soaking Time Range | 0–6000 min |
| Hold Time Range | 0–6000 min |
| 预约 Function | Up to 100 h |
| Heating Power | 3.5 kW |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Operating Ambient | 5–40 °C, 20–80 % RH |
| Standard Cooling | Air + Secondary Water Cooling + Condenser |
| Safety Features | Dual mechanical pressure lock, lid self-check, overtemperature cutoff, dry-run protection, overpressure relief, electric leakage protection, overload protection, short-circuit protection, independent electronic overpressure sensor |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-85FI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 725 mm |
| External Dimensions | 585 × 750 × 1165 mm |
| Chamber Volume | 85 L |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-85VE |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 725 mm |
| External Dimensions | 535 × 640 × 1165 mm |
| Chamber Volume | 85 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Power Supply | ~220 V ±22 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |