Sulfur and Nitrogen Analyzer
Filter
Showing 1–30 of 31 results
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5010 |
| Detection Principle | Chemiluminescence (N) / UV Fluorescence (S) with MPO High-Nitrogen Interference Compensation |
| LOD (N) | 10 ppb |
| LOD (S) | 5 ppb |
| Linear Range (S) | up to 10,000 mg/kg |
| Analysis Time | 2–5 min per sample |
| Compliance | ASTM D5453, D7183, ISO 20846, ISO 29189, GB/T 17040, GB/T 17674, USP <233>, EPA Method 1664A (adapted), GLP/GMP-ready |
| Automation | Fully automated calibration, parameter optimization, and continuous unattended operation |
| Footprint | < 0.3 m² |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5010 SPMO |
| Detection Principle | High-Temperature Combustion Coupled with UV-Fluorescence (S), Chemiluminescence (N), IR Absorption (C), and Microcoulometric Titration (Cl) |
| Detection Limits | <0.02 mg/kg (S), <0.05 mg/kg (N), <0.1 mg/kg (C), <0.05 mg/kg (Cl) |
| Sample Forms | Liquids, Gases, Liquefied Petroleum Gas (LPG), Liquefied Natural Gas (LNG), Solids (with optional solid module) |
| Analysis Time | 2–5 min per sample |
| Throughput | Up to 120 samples/day (unattended) |
| Linear Dynamic Range | 4–6 orders of magnitude |
| Compliance | ASTM D5453, D7183, D7039, ISO 20846, ISO 20884, UOP 975, IP 542, EN ISO 14596, USP <233>, FDA 21 CFR Part 11 (with optional audit trail & electronic signature) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | multi EA 5010 |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | multi EA 5010 |
| Price | Upon Request |
| Detector | HiPerSens UV Fluorescence & Chemiluminescence Detector |
| Measurement Range | 0.0x ppm to 100% (w/w or v/v) |
| Sample Volume | Liquids: 50 µL |
| Gases | 20 mL |
| Combustion Furnace Temperature | Up to 1100 °C |
| Compliance | ASTM D5453, D7183, D7039, ISO 20846, ISO 20884, UOP 97, IP 433, IP 541, EN 15486 |
| Software | multiWin v5.x with 21 CFR Part 11 compliance modules |
| Connectivity | Ethernet, LIMS-ready, Remote Web Access via Browser or Mobile App |
| Safety | Automated Self-Check, Real-Time Parameter Monitoring, Push Notification Alert System |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5100 |
| Application Scope | Solid, Liquid and Gas Samples |
| Combustion Technology | Dual-Mode High-Temperature Catalytic Combustion (950–1150 °C) |
| Detection Principle | UV-Fluorescence (S), Chemiluminescence (N), Microcoulometric Titration (Cl), IR Absorption (C) |
| Sample Throughput | Up to 120 samples/day (with auto-sampler) |
| Compliance | ASTM D5291, D3120, D4294, D5762, ISO 20846, ISO 14596, UOP 390, IP 287, EN ISO 14596 |
| Safety Features | Integrated self-diagnostic system, real-time parameter monitoring, carbon deposit prevention via FIRE sensor technology |
| Automation | Optional high-capacity autosampler (up to 120 positions), gas sampling module (for LPG, natural gas, refinery streams) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | multi EA H 5000 |
| Price Range | USD 68,000 – 109,000 |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS N |
| Measurement Element | Nitrogen |
| Measurement Principle | Chemiluminescence Detection |
| Detection Limit | 5 ppb |
| Quantitation Range | 10 ppb – 10 % |
| Furnace Temperature Range | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 51 × 78 × 56 cm |
| Weight | 32 kg |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS S |
| Measurement Element | Sulfur |
| Measurement Principle | Ultraviolet Fluorescence (UVF) |
| Detection Limit | 5 ppb |
| Quantitation Limit | 10 ppb |
| Measurement Range | 5 ppb – 10% w/w |
| Combustion Furnace Temperature | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Gas Requirements | O₂ ≥99.998% at 3 bar, Ar ≥99.995% at 3 bar |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 51 × 78 × 56 cm |
| Weight | 32 kg |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HELIOS S&N |
| Measurement Elements | Sulfur (S), Nitrogen (N) |
| Measurement Principle | UV Fluorescence (S) / Chemiluminescence (N) |
| Detection Limit | 5 ppb (S), 5 ppb–10% (N) |
| Quantitation Range | 10 ppb–10% (S & N) |
| Furnace Temperature Range | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Display | 7-inch touchscreen interface |
| Languages | English, French, Spanish, German, Russian, Chinese |
| Compliance | ASTM D5453, D6667, D7183, D7551, D4629, D6069, D5762 |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS SN&CL |
| Measurement Elements | Sulfur (S), Nitrogen (N), Chlorine (Cl) |
| Measurement Principles | UV Fluorescence (S), Chemiluminescence (N), Coulometric Titration (Cl) |
| Detection Limits | 5 ppb (S), 5 ppb–10% (N), 50 ppb–80+% (Cl) |
| Quantitation Ranges | 10 ppb–100 ppm (S), 10 ppb N–10% (N), <0.1 ppm–80+% (Cl) |
| Combustion Furnace Temperature | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Built-in Languages | English, French, Spanish, German, Russian, Chinese |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 1200 |
| Detection Principle | Plasma Emission Spectroscopy |
| Measurement Range | 0–2 ppm, 0–10 ppm, 0–20 ppm, 0–100 ppm, 0–200 ppm N₂ in Ar |
| Accuracy | ±0.02 ppm (0–2 ppm range), ±0.25 ppm (0–10/0–20 ppm ranges), ±2.50 ppm (0–100/0–200 ppm ranges) |
| Sensitivity | ±0.01 ppm (Model 1200-A/1202-A), ±0.10 ppm (1200-B/1202-B), ±1.00 ppm (1200-C/1202-C) |
| Sample Flow Rate | 2 scfh (0.88 slpm) |
| Inlet/Outlet Fittings | 1/4" VCR inlet, 1/4" Swagelok outlet |
| Operating Temperature | 16–35 °C (60–95 °F) |
| Max Inlet Pressure | 10 psig |
| Measurement Cell Pressure | 6 psig |
| Normal Inlet Pressure | 2–7 psig |
| Output Signals | 4–20 mA analog, dry contact alarms |
| Power | 100 W, 115/230 VAC, 50/60 Hz |
| Dimensions | 13.34 × 42.23 × 37.15 cm |
| Weight | 11.3 kg |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 210 SA |
| Detection Principle | Flame Photometric Detection (FPD) |
| Detection Target | Total Sulfur in Gaseous or Liquid CO₂ |
| Detection Limit | <5 ppb for COS |
| Linear Dynamic Range | >3 orders of magnitude |
| Compliance | ISBT Methods 13 & 14 |
| Installation | Benchtop or Rack-Mountable |
| Operating Mode | Continuous or Discrete Flow |
| Calibration | Automated Onboard Calibration |
| Temperature Control | Factory-Set Constant-Temperature Detection Zone |
| Brand | Hongtu |
|---|---|
| Origin | Shandong, China |
| Model | SP-6802 |
| Detection Limit (as S in H₂S) | 0.01 mg/m³ (Type A, non-conversion) |
| Measurement Range (as S in H₂S, undiluted) | 0.01–50 mg/m³ (extendable to 0.1–500 mg/m³) |
| Repeatability (RMS error) | <5% (n ≥10, certified H₂S standard gas or CS₂ permeation source) |
| Column Temperature Control | Ambient to 100°C ±0.2°C |
| Permeation Source Temperature Control | Ambient to 50°C ±0.1°C |
| Detector Temperature Control | Ambient to 110°C ±1°C |
| Converter Furnace Temperature | Ambient to 900°C ±5°C |
| High-Voltage Power Supply | –400 V to –800 V adjustable |
| Compliance | GB/T 19001–2016 (ISO 9001), GB/T 14001–2016 (ISO 14001) |
| Brand | Kanchang |
|---|---|
| Model | TS-9100 |
| Measurement Principle | UV Fluorescence |
| Detection Element | Sulfur |
| Detection Range | 0.2–10,000 mg/L |
| LOD | 0.1 mg/L |
| Repeatability | RSD < 3% |
| Linearity (R²) | > 0.999 |
| Cracking Furnace Temp | Ambient to 1300 °C (±2 °C) |
| Gas Flow Control | 0–600 mL/min (accuracy ≤1%) |
| Power Supply | AC 220 V, 50 Hz |
| Sample Introduction | Automated Vertical Liquid Autosampler |
| Reaction Gas | Compressed Air (no Ar/O₂ required) |
| Compliance | ASTM D5453, GB/T 34100, GB/T 11060, SH/T 0689, SH/T 1820 |
| Data Export | LIMS-compatible formats |
| Brand | Kanchang |
|---|---|
| Origin | Jiangsu, China |
| Model | TS9000 |
| Detection Principle | UV Fluorescence |
| Detection Range | 0.01–10,000 mg/L |
| LOD | 0.01 mg/L |
| Repeatability | RSD < 3% (0.2–1.0 mg/L), RSD < 2% (1.0–10,000 mg/L) |
| Linearity | Correlation coefficient > 0.999 (linear fit) |
| Furnace Temp Range | Ambient to 1300 °C |
| Temp Control Accuracy | ±2 °C |
| Autosampler Capacity | 156-position liquid autosampler |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Koyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KY-3000SN |
| Price | ¥260,000 |
| Standards Compliance | SH/T 0689, ASTM D5453 (S), SH/T 0657, ASTM D4629 (N) |
| Measurement Methods | UV Fluorescence (S), Chemiluminescence (N) |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| S Range | 0.2 mg/L to 100% w/w |
| N Range | 0.1 mg/L to 100% w/w |
| LOD | 0.2 mg/L (S), 0.1 mg/L (N) |
| Carrier Gases | ≥99.98% O₂, ≥99.98% Ar |
| Furnace Temp Range | Ambient to 1100 °C |
| Temp Control Accuracy | ±3 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Power Consumption | 2 kW |
| Dimensions | 680 × 480 × 400 mm |
| Data Acquisition | 24-bit USB interface, signal resolution <1 µV |
| PMT Voltage | Adjustable |
| Calibration | Single-point or multi-point |
| Software | Cross-platform (Windows/macOS/Linux), GLP-compliant data handling |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-3000S |
| Price Range | USD 7,000 – 14,000 |
| Detection Principle | Ultraviolet Fluorescence (UVF) for Total Sulfur |
| Compliance Standards | SH/T 0689, ASTM D5453, GB/T 34100-2017 |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | 0.2 mg/L to 5000 ppm (equivalent to 0.00002–0.5 wt%) |
| LOD | 0.2 mg/L (as S) |
| Repeatability | ±0.2 mg/L at 1.0 mg/L |
| Furnace Temp Control | Ambient to 1300 °C, ±1 °C stability |
| Carrier & Oxidant Gases | High-purity O₂ (≥99.98%), high-purity Ar (≥99.98%) |
| Power Requirement | 2 kW |
| Data Acquisition | 24-bit ADC, USB 2.0 interface, minimum detectable signal <1 µV |
| PMT Voltage | Adjustable, software-controlled |
| Calibration Modes | Single-point or multi-point linear/nonlinear curve fitting |
| Software Compatibility | Windows 7/10/11, macOS (via Wine-compatible runtime), Linux (CLI support) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-3000S |
| Compliance Standards | GB/T 34100–2017, SH/T 0689, ASTM D5453 |
| Detection Method | UV Fluorescence (S) |
| Detection Range | 0.2 mg/L to 5000 ppm (up to % level) |
| LOD (S) | 0.2 mg/L |
| Repeatability | ±0.2 mg/L at ≤1.0 mg/L |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| Furnace Temp Range | Ambient to 1300 °C |
| Temp Control Accuracy | ±1 °C |
| Gas Requirements | High-purity O₂ (≥99.98%), High-purity Ar (≥99.98%) |
| Power Rating | 2 kW |
| Data Acquisition | 24-bit ADC, USB Interface |
| PMT Voltage | Adjustable |
| Calibration Options | Single-point or multi-point calibration |
| Software Compatibility | Windows 7/10/11, macOS (via Wine-compatible runtime), Linux (CLI support) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-3000S |
| Detection Principle | UV Fluorescence (for Total Sulfur) |
| Applicable Standards | SH/T 0689, ASTM D5453 |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | 0.2 mg/L to 5000 ppm (as S) |
| LOD | 0.2 mg/L (S) |
| Oxygen Purity | ≥99.98% |
| Argon Purity | ≥99.98% |
| Furnace Temperature Range | Ambient to 1100 °C |
| Temperature Control Accuracy | ±3 °C |
| Power Consumption | 2 kW |
| Dimensions (W×D×H) | 680 × 480 × 400 mm |
| Data Acquisition | 24-bit ADC, USB Interface |
| PMT High Voltage | Adjustable |
| Calibration Options | Single-point or multi-point curve calibration |
| Software Compatibility | Windows 7/10/11, macOS (via virtualization), Linux (CLI support) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-33400 |
| Price Range | USD 2,800 – 7,000 |
| Vacuum Pump | Single-stage rotary vane pump |
| Vacuum Regulation | Stainless steel needle valve |
| Filtration Control | Solenoid valve actuated negative pressure control |
| Vacuum Gauge Range | 0 to –0.1 MPa |
| Power Consumption | 180 W |
| Dimensions (L×W×H) | 380 × 400 × 400 mm |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | Temperature 0–45 °C, Relative Humidity ≤80% |
| Sample Viscosity Limit | ≤8 mm²/s at 20 °C or ≤5 mm²/s at 40 °C |
| Measurable Contaminant Range | 12–30 mg/kg |
| Applicable Fuels | Diesel with >30% FAME content, and other hydrocarbon-based fuels beyond standard viscosity limits |
| Brand | Kyoyuan |
|---|---|
| Model | KY-3000 S/N |
| Measurement Principle | UV Fluorescence (S), Chemiluminescence (N) |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| Detection Limits | 0.2 mg/L (S), 0.1 mg/L (N) |
| Calibration | Single- or multi-point standard calibration |
| Temperature Control Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.5% ±3 °C |
| Carrier Gas | Argon ≥99.98%, Oxygen ≥99.98% |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz, 2 kW |
| Dimensions | 680 × 480 × 400 mm |
| Compliance Standards | SH/T 0689, ASTM D5453 (S) |
| Brand | Kyoyuan |
|---|---|
| Model | KY-3000N |
| Application | Total nitrogen analysis in liquid, solid, and gaseous petroleum & chemical samples |
| Detection Principle | Chemiluminescence detection of NO* (nitric oxide) after high-temperature oxidative pyrolysis |
| Measurement Range | 0.1 mg/L to 5000 ppm (equivalent to ~0.00001–0.5 wt%) |
| LOD | 0.1 mg/L (as N) |
| Repeatability | ≤ ±0.1 mg/L (for X < 1.0 mg/L) |
| Pyrolysis Temp Range | Ambient to 1100 °C |
| Temp Control Accuracy | ±3 °C |
| Gas Requirements | ≥99.98% purity O₂ and Ar |
| Power | 2 kW |
| Dimensions | 680 × 480 × 400 mm |
| Compliance | SH/T 0657, ASTM D4629 |
| Data Acquisition | 24-bit USB interface, signal resolution <1 µV |
| Optional Accessories | Solid/gas sampling modules, light/heavy quartz pyrolysis tubes, certified N standards |
| Brand | Kyoyuan |
|---|---|
| Model | KY-3000S |
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Detection Principle | UV Fluorescence (S) |
| Detection Range | 0.2 mg/L to 5000 ppm (up to % level) |
| LOD | 0.2 mg/L (as S) |
| Repeatability | ±0.2 mg/L at 1.0 mg/L |
| Temperature Control Range | Ambient to 1300 °C |
| Temperature Stability | ±1 °C |
| Power Consumption | 2 kW |
| Gas Requirements | High-purity O₂ (≥99.98%) and Ar (≥99.98%) |
| Data Acquisition | 24-bit ADC, USB interface, min. detectable signal <1 µV |
| Compliance Standards | SH/T 0689, ASTM D5453, GB/T 34100-2017 |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KY-3000S |
| Detection Principle | UV Fluorescence (for Sulfur) |
| Applicable Standards | SH/T 0689, ASTM D5453 |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| Measurement Range | 0.2 mg/L to 5000 ppm (as sulfur) |
| Detection Limit | 0.2 mg/L (S) |
| Carrier Gases | High-purity O₂ (≥99.98%), High-purity Ar (≥99.98%) |
| Furnace Temperature Range | Ambient to 1100 °C |
| Temperature Control Accuracy | ±3 °C |
| Power Consumption | 2 kW |
| Dimensions (W×D×H) | 680 × 480 × 400 mm |
| Data Acquisition | 24-bit ADC, USB interface |
| PMT Voltage | Adjustable |
| Calibration Options | Single-point or multi-point calibration |
| Software Compatibility | Windows, macOS, Linux |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KY-3000SN |
| Detection Method (S) | UV Fluorescence |
| Detection Method (N) | Chemiluminescence |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| Sulfur Range | 0.2 mg/L to 100% w/w |
| Nitrogen Range | 0.1 mg/L to 100% w/w |
| LOD (S) | 0.2 mg/L |
| LOD (N) | 0.1 mg/L |
| Oxygen Purity | ≥99.98% |
| Argon Purity | ≥99.98% |
| Furnace Temp Range | Ambient to 1100 °C |
| Temp Control Accuracy | ±3 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Power Consumption | 2 kW |
| Dimensions (W×D×H) | 680 × 480 × 400 mm |
| Compliance Standards | SH/T 0689, ASTM D5453 (S) |
| Brand | Kyoyuan |
|---|---|
| Model | KY-HW1A |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic (China-Made) |
| Price Range | USD 7,000 – 14,000 (FOB China) |
| Measurement Principle | Arc Combustion Followed by Non-Dispersive Infrared (NDIR) Absorption |
| Elemental Coverage | Simultaneous C and S Quantification |
| Carbon Range | 0.005–6.0000 wt% (extendable to 99.999%) |
| Sulfur Range | 0.0005–0.3500 wt% (extendable to 99.999%) |
| Sample Mass (Solid Steel Reference) | 0.5 g ±20%, Continuous Weighing Mode |
| Analysis Precision | C meets or exceeds GB/T 223.69–2008 |
| Typical Analysis Time | 35 s (adjustable 20–60 s) |
| Operational Duty Cycle | 24/7 Continuous Operation |
| Detector | High-Stability Pyroelectric Infrared Sensor |
| Analysis Cell | Gold-Plated NDIR Cell |
| Light Source | Custom Platinum-Based IR Emitter |
| Power Supply | Taiwan-Made Switching Power Supply |
| Solenoid Valves | Airtac (Taiwan) Pneumatic Valves |
| Motor | Aerospace-Grade Synchronous Motor (100,000 hr MTBF) |
| Combustion Unit | KY-DRL1 Arc Furnace (2200 W Output) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 2400 |
| Operating Modes | CHN, CHNS, O |
| Analysis Time | 4–8 min |
| Accuracy (CHN/CHNS/O) | ≤0.3% |
| Precision (CHN/CHNS/O) | ≤0.2% |
| Detection Range (C/H/N/S/O) | 0.001–6.0 mg |
| Combustion/Reduction/Pyrolysis Furnace Temp | 100–1800 °C |
| Carrier Gases | He, Ar |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SULFUVL |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart CN/CNS |
| Detection Principle | Dynamic Flash Combustion coupled with Gas Chromatographic Separation |
| Detector Options | TCD (standard), optional chemiluminescence or IR detectors |
| Combustion Temperature | up to 1800 °C (Sn capsule mode) |
| Warranty | 15 years on combustion furnace and TCD detector |
| Automation | Fully software-controlled oxygen injection, sample weighing, and combustion timing |
| Compliance | Designed for GLP/GMP environments |
| Carrier Gas Options | Helium (standard), Argon (cost-optimized alternative) |
| Modular Configurations | Upgradable to CHNS, CHN, NC, NCS, N, S, O modes |
| Sample Types | Solids (soils, sediments, biomass, coal, polymers), liquids (oils, extracts, aqueous solutions), and heterogeneous matrices |
| Throughput | Up to 120 samples/day with dual autosamplers (solid + liquid) |
| Software Platform | EagerQ™ v3.2 with method templates, calibration wizards, and raw data export (CSV, XML, PDF) |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER NS |
| Detection Principle | UV Fluorescence for Sulfur / Chemiluminescence for Nitrogen |
| Sample Types | Liquids, Gases, LPG, Solids |
| Measurement Range | S and N from sub-ppb to percent level |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D5453, D7183, D7184 |
| Optional Autosamplers | 105-position 2-mL vial XYZ autosampler (with auto-dilution & auto-calibration), Gas/LPG autosampler, 20-position solid autosampler |
| Detector | Temperature-controlled UVF and CLD detectors with active feedback loops |
| Automation Level | Fully automated combustion, gas flow control, calibration, and data validation |