| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 81X30 |
| Measurement Capability | Planar (2D/3D) |
| Frame Rate | >100 Hz |
| Velocity Range | 0–0.5 m/s |
| Accuracy | ±1% of full scale |
| Measurement Area | 190 mm × 120 mm |
| Illumination Source | High-power pulsed LED array with fiber-coupled lens system |
| Camera | FlowSense USB 2M-165 (2 MP, global shutter, 165 fps @ full resolution) |
| Synchronization | Software-controlled via DynamicStudio v7.x |
| Data Acquisition & Analysis | DynamicStudio PIV software suite |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | MicroPIV |
| Measurement Domain | 15 µm × 15 µm to 3 mm × 3 mm |
| Velocity Range | 0–2 m/s |
| Accuracy | ±1% of measured velocity |
| Spatial Resolution | Down to ~1 µm (dependent on optics & particle seeding) |
| Temporal Resolution | Low-frequency operation (typically < 100 Hz, configurable via laser pulse separation and camera frame rate) |
| Optical Configuration | Inverted fluorescence microscope optimized for PIV |
| Camera Option | HiSense MkII sCMOS sensor with peak quantum efficiency of 72% |
| Upgrade Paths | Unstructured grid PIV, MicroLIF (Micro Laser-Induced Fluorescence) |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | MiniPIV |
| Measurement Plane | 2D/3D |
| Frame Rate | >100 Hz |
| Velocity Range | 0–5 m/s |
| Accuracy | ±1% of reading |
| Measurement Area | 150 mm × 120 mm |
| Camera | FlowSense USB 2M-165 (1920 × 1200 px, 165 fps) |
| Laser Source | RayPower (2/5/10 W, air-cooled, TEM₀₀ mode) |
| Software Platform | DynamicStudio |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Import Category | Imported |
| Model | Low-Frequency PIV |
| Measurement Capability | Planar (2D/3D) |
| Measurement Frequency | Low-Frequency |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% |
| Measurement Area | 200 mm × 200 mm to 1000 mm × 1000 mm |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | VV |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Velocity Range | 0–300 m/s |
| Measurement Volume | 200 mm × 200 mm × 40 mm |
| Accuracy | ±1% of measured velocity |
| Temporal Resolution | Low-frequency acquisition (configurable via camera framing rate and laser repetition rate) |
| Particle Seeding Density | 0.05–0.07 particles per pixel (PPP) |
| Camera Configuration | 2–4 synchronized high-speed CMOS cameras |
| Illumination | Volumetric light sheet or tomographic LED/laser array |
| Software Platform | DynamicStudio with GPU-accelerated volumetric reconstruction (up to 240 CUDA cores) |
| Brand | DITECT |
|---|---|
| Origin | Japan |
| Model | PIV 2D2C, PTV 2D2C (2D/3D), PIV 2D3C (3D) |
| Measurement Capability | 3D3C volumetric velocity field reconstruction |
| Frame Rate Support | ≥100 Hz |
| Supported Image Formats | AVI, WMV, JPG, BMP, TIFF, PNG |
| Data Export Formats | Project (.flw), CSV |
| Correlation Method | Direct Cross-Correlation (PIV), Binary Correlation (PTV) |
| Physical Quantities Computed | Vorticity, Turbulent Kinetic Energy, Reynolds Stresses, Velocity Gradient Tensor, RMS Velocity Fluctuations |
| Operating System | 64-bit Windows with SSE2/SSE3 instruction set support |
| CPU Architecture | Multi-core parallel processing optimized |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Mitas |
| Measurement Domain | Planar (2D/3D) |
| Measurement Frequency | Low-Frequency |
| Velocity Range | 0–20 m/s |
| Accuracy | ±1% |
| Measurement Field Size | 0–1 mm |
| Microscope Objective Magnification | 5×–40× |
| CCD Resolution | 1376 × 1040 pixels |
| Quantum Efficiency | 65% @ 500 nm |
| Interframe Time (min) | 500 ns |
| Spatial Resolution (XYZ Stage) | 0.05 µm |
| Positioning Accuracy (XYZ Stage) | ±3 µm |
| Travel Range (X/Y) | 120 mm |
| Travel Range (Z) | 20 mm |
| Sample Opening | 84 × 70 mm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster 4D-PTV |
| Measurement Modality | Stereoscopic 3D3C (Three-Component, Three-Dimensional) |
| Temporal Resolution | >100 Hz |
| Velocity Range | 0–1000 m/s |
| Velocity Uncertainty | ±1% of measured value |
| Measurement Volume | 1000 mm × 1000 mm × 1000 mm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster FSI |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Frame Rate | >100 Hz |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% of measured value |
| Measurement Volume | 1000 mm × 1000 mm × 1000 mm |
| Technique Integration | Synchronized Particle Image Velocimetry (PIV) and Digital Image Correlation (DIC) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster-STB |
| Measurement Capability | True 3D, three-component (3D3C) volumetric velocity field |
| Measurement Frequency | Low-to-medium temporal resolution (suitable for transient and quasi-steady flows) |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% of measured velocity magnitude |
| Measurement Volume | 1 m × 1 m × 1 m (adjustable via optical configuration and seeding density) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster® 3D |
| Measurement Dimensionality | 2D & 3D planar vector fields |
| Frame Rate | >100 Hz |
| Velocity Range | 0–3,000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Field Size | 1 m × 1 m |
| Optical Configuration | Dual-camera stereoscopic imaging with Scheimpflug-aligned lenses |
| Calibration | Self-calibration enabled (target-free, off-field, distortion-corrected) |
| Software Platform | DaVis® v10+ |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster® |
| Measurement Capability | 2D & 3D planar velocity fields |
| Velocity Range | 0–2000 m/s |
| Accuracy | <1% RMS error |
| Measurement Area | 400 × 400 mm |
| Laser Pulse Energy | up to 2 × 425 mJ per pulse |
| Camera Resolution Options | 1 MP to 29 MP |
| Temporal Resolution | Single-shot to MHz-rate TR-PIV |
| Correlation Precision | ≤0.1 pixel |
| SNR (Velocity Field) | >45 |
| High-Confidence Vector Yield (>0.1 px error threshold) | >90% |
| Compliance | ASTM E2847, ISO 20486, GLP/GMP-ready data audit trail support in DaVis |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster® thermographic |
| Measurement Capability | Planar (2D/3D) |
| Repetition Rate | 3 kHz |
| Velocity Range | ≤ 3.5 km/s |
| Temperature & Velocity Accuracy | ±1% of reading |
| Measurement Field Size | 200 mm × 200 mm |
| Particle Tracer | Micrometer-scale thermographic phosphor particles |
| Core Principle | Simultaneous phosphorescence lifetime-based thermometry and cross-correlation PIV |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Adaptive |
| Measurement Domain | 2D/3D Planar |
| Measurement Frequency | Low-Frequency |
| Velocity Range | 0–2 km/s |
| Accuracy | ±1% |
| Measurement Area | 1 m × 1 m |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster®-Dual |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Measurement Frequency | Low-Frequency Operation (Typical Repetition Rates: 1–15 Hz for Dual-Plane Acquisition) |
| Velocity Range | 0–2,000 m/s |
| Accuracy | ±1% of Measured Velocity Magnitude |
| Measurement Field of View | Up to 1.0 m × 1.0 m (Configurable via Lens and Laser Sheet Geometry) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Endo |
| Measurement Domain | Planar (2D/3D) |
| Velocity Range | 0–2 km/s |
| Accuracy | ±1% of reading |
| Field of View | Up to 1 m × 1 m |
| Frame Rate | Low-frequency acquisition (typically < 100 Hz for high-resolution endoscopic configurations) |
| Optical Bandpass | Visible to UV (193–700 nm) |
| Compliance | Designed for integration with ASTM E2847, ISO 20456, and GLP/GMP-aligned experimental workflows |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Micro |
| Measurement Domain | 2D & 3D planar velocity fields |
| Measurement Frequency | Low-frequency dual-pulse acquisition |
| Velocity Range | 0–10 m/s |
| Accuracy | ±1% of measured velocity |
| Field of View | 10 µm – 1 mm |
| Objective Magnification Range | 5× – 40× |
| Standard Camera | 1376 × 1040 pixels, 65% quantum efficiency @ 500 nm |
| Spatial Resolution | Down to ~0.1 pixel displacement uncertainty |
| Microscope Configuration | Upright or inverted fluorescence-compatible platform |
| Illumination Source | Dual-pulse Nd:YAG laser (typically 532 nm) |
| Tracer Compatibility | Fluorescent microspheres (e.g., Rhodamine B-doped polystyrene, 0.1–2 µm diameter) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-surf |
| Measurement Domain | Planar (2D/3D) |
| Measurement Frequency | Low-frequency |
| Velocity Range | 0–2 km/s |
| Accuracy | ±1% of reading |
| Field of View | Up to 1 m × 1 m |
| Camera Requirement | Dual-camera stereo configuration |
| Core Technology | Digital Image Correlation (DIC) + Stereoscopic PIV |
| Software Platform | DaVis® v8.4+ |
| Compliance | ASTM E2847, ISO/IEC 17025-compatible workflows, GLP-aligned data traceability |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster®-Tomo |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Measurement Frequency | Low-to-Medium Repetition Rate (Typical Dual-Frame Acquisition) |
| Velocity Range | 0–2000 m/s |
| Accuracy | ±1% of measured velocity magnitude |
| Measurement Volume | 170 mm × 110 mm × 100 mm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster®-TR |
| Measurement Domain | 2D & 3D Planar |
| Frame Rate | >100 Hz (up to 100 kHz at reduced resolution) |
| Velocity Range | 0–8000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Area | 400 × 400 mm |
| Camera Resolution | 1024 × 1024 pixels @ 5 kHz |
| Laser | High-Repetition Solid-State, Dual-Cavity, up to 50 mJ/pulse |
| Software Control | Fully integrated with DaVis® v10+ |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-UW |
| Measurement Domain | Planar (2D/3D) |
| Measurement Frequency | Low-frequency operation |
| Velocity Range | 0–2,000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Area | Up to 1 m × 1 m |
| Optical Architecture | Modular submersible configuration with surface-mounted electronics |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments and GLP-compliant fluid dynamics research |
| Brand | LaVision GmbH |
|---|---|
| Country of Origin | Germany |
| Model | OA-STB |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Measurement Frequency | Low-Frequency Temporal Resolution |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Volume | 1 m × 1 m × 1 m |
| Software Requirement | DaVis 11.2 or later |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Model | MicroPIV |
| Measurement Domain | Planar (2D/3D) |
| Measurement Frequency | Low-frequency |
| Velocity Range | 0–10 m/s |
| Accuracy | ±3% |
| Field of View | 100 µm – 1000 µm |
| Light Source | Tunable LED (450–460 nm), Continuous / Dual-pulse Modes |
| Frame Rate | Up to 100 fps @ full resolution (2560 × 2160) |
| Camera | PCO edge 4.2, 16-bit, Quantum Efficiency >60%, Read Noise ≤1 e⁻, Dynamic Range ≥30,000:1 |
| Synchronization | External trigger, single/dual pulse, programmable delay (≤200 ns) |
| Software | PIVtec ILA with dedicated MicroPIV module (top-tier performance in PIV Challenge benchmarks) |
| Brand | Bt Fluid |
|---|---|
| Model | Mini TR PIV |
| Type | Time-Resolved Particle Image Velocimetry System |
| Origin | Beijing, China |
| Measurement Area | ≥300 mm × 300 mm |
| Velocity Range | 0–5 m/s |
| Temporal Resolution | 0.5–4 kHz (full-resolution frame rate) |
| Laser | Continuous-wave, 532 nm, 0–2 W adjustable output, power stability <1% |
| Camera | PCO dimax CS1 (1296 × 1024, 12-bit, QE >50%, max 3000 Hz at full resolution) or PCO 1200HS (1280 × 1024, 4 GB memory, max 637 Hz at full resolution) |
| Accuracy | ±3% of measured velocity |
| Data Formats Supported | TIFF, BMP, JPEG, B16 (PCO 16-bit), PNG, PBM |
| Software | PIVview (winner-tier in multiple PIV Challenge benchmarks) |
| Compliance | Designed for GLP-aligned experimental workflows |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 2D2CPIV |
| Measurement Capability | Planar (2D/3D) Velocity Field |
| Operating Frequency | Low-Frequency (≤15 Hz) |
| Velocity Range | 0–1500 m/s |
| Accuracy | ±3% of reading |
| Measurement Area | ≥400 mm × 400 mm |
| Core Components | PCO edge 5.5M dual-frame camera, dual-cavity double-pulse Nd:YAG laser (532 nm), nanosecond-precision synchronization controller, PIV post-processing software suite |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DGV |
| Price Range | USD 270,000 – 410,000 (based on configuration and integration support) |
| Measurement Mode | Planar (2D/3D capable) |
| Acquisition Frequency | Low-to-Medium Repetition Rate (typically 1–10 Hz for high-energy pulsed operation) |
| Velocity Range | 0–3000 m/s |
| Absolute Velocity Accuracy | ±0.8–1.4 m/s |
| Measurement Field of View | 120 mm × 120 mm |
| Core Optical Filter | Integrated Iodine Vapor Molecular Filter with Thermal Stabilization |
| Laser Source | Narrow-Linewidth Pulsed or CW Diode-Pumped Solid-State Laser (532 nm typical) |
| Detection Architecture | Dual-Camera Configuration (Signal + Reference) |
| Compliance | Designed to support GLP-compliant experimental workflows |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FRS |
| Price Range | USD 270,000 – 410,000 (based on EUR/USD exchange and landed cost) |
| Measurement Modality | Planar (2D/3D) |
| Repetition Rate | Low-Frequency (Single-Shot to ~10 Hz typical) |
| Velocity Range | 0–300 m/s |
| Velocity Uncertainty | ±0.8–1.4 m/s |
| Measurement Field of View | 120 mm × 120 mm |
| Temperature Range | 100–2000 K |
| Temperature Uncertainty | ±1% |
| Pressure Range | 0.1–20 bar |
| Pressure Uncertainty | ±3% |
| Particle-Free Operation | Yes |
| Upgrade Path | Compatible with Doppler Global Velocimetry (DGV) architecture |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TR PIV |
| Price Range | USD 270,000 – 405,000 (based on configuration) |
| Measurement Mode | Planar (2D) and Volumetric (3D) |
| Frame Rate | Up to 10 kHz (full resolution), >100 Hz standard operation |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±3% of measured velocity magnitude |
| Measurement Area | ≥400 mm × 400 mm (2D) |
| Laser Source Options | High-repetition-rate pulsed Nd:YAG or LED-based illumination |
| Camera Resolution | Configurable up to 4 MP at 10 kHz |
| Synchronization Precision | <10 ns jitter |
| Software Platform | PIVtec ILA v5.x with GLP-compliant audit trail and metadata embedding |
| Brand | Revealer |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PIV-EDU Educational PIV System |
| Measurement Capability | 2D Planar Flow Field Visualization and Quantification |
| Operating Frequency | Low-Frequency Synchronized Imaging (Typical Range: 1–15 Hz) |
| Flow Visualization Medium | Water-based Seeded Flow |
| Core Components | Recirculating Water Channel, Cylindrical Obstacle Set, Pulsed Laser Illumination Module (532 nm, Class IV), High-Sensitivity CMOS Camera (12-bit, 1280×1024 resolution, Global Shutter), RFlow2D2C Acquisition & Cross-Correlation Software |
| Compliance | Designed for Academic Use in Accordance with ASTM E2655–21 (Standard Guide for Education in Fluid Mechanics) and ISO/IEC 17025:2017 Principles for Calibration Laboratories |