| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SO-100 |
| Output | 0–50 mV (SO-100), 0–12 mV (SO-200) |
| Measurement Range | 0–100% O₂ |
| Accuracy | <0.02% drift/day |
| Repeatability | ±0.001% O₂ (10 ppm) |
| Response Time | 60 s (SO-100), 12 s (SO-200) |
| Operating Temperature | –20 to +60 °C |
| Relative Humidity | 0–100% RH |
| Pressure Range | 60–140 kPa |
| Power Supply | 12 V for heater |
| Sensor Housing | Polypropylene valve body |
| Cable Length | 2 m |
| Weight | 210 g |
| Lifetime | >10 years (SO-100), >5 years (SO-200) |
| Interference | None from CO₂, CO, NO, NO₂, H₂S, H₂, CH₄ |
| Brand | Axetris |
|---|---|
| Origin | Switzerland |
| Model | EMIRS200, EMIRS50 |
| Housing | TO-39 metal can |
| Emitter Type | MEMS micro-hotplate with dielectric thin-film coating |
| Spectral Range | 2–16 µm (blackbody-like emission) |
| Modulation Capability | Direct electrical square-wave modulation (chopper-free) |
| Typical Power Consumption | <150 mW (EMIRS200), <300 mW (EMIRS50) |
| Radiant Efficiency | >30% (relative to ideal blackbody at same temperature) |
| Lifetime | >100,000 hours (at nominal drive conditions) |
| Environmental Certification | IEC 60747-17 / IEC 62047-21 compliant |
| Window Options | Sapphire (Al₂O₃), CaF₂, BaF₂, Ge |
| Mounting | Standard TO-39 header with optional reflective cup or protective cap |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE piD-TECH eVx |
| Pricing | Available Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | eV-NXT 045-110 |
| Price | Upon Request |
| Detection Range | 0–10,000 ppm |
| LOD | 500 ppb |
| T90 Response Time | < 3.5 s |
| Typical Sensitivity | 0.6 mV/ppm |
| Calibration Gas | 2000 ppm Isobutylene (standard) |
| Operating Temperature | –20 °C to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 3.3 V DC nominal |
| Power Consumption | < 80 mW (active mode) |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | eV-NXT 045-111 |
| Detection Range | 0–2,000 ppm |
| LOD | 100 ppb |
| T90 Response Time | < 3.5 s |
| Typical Sensitivity | 2.4 mV/ppm |
| Measurement Condition | 100 ppm |
| Operating Voltage | Low-Voltage DC |
| Power Consumption | Ultra-Low |
| Intrinsic Safety Rating | Certified |
| Onboard Fault Detection | Yes |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-112 |
| Detection Range | 0–200 ppm |
| LOD | 10 ppb |
| T90 | < 3.5 s |
| Typical Sensitivity | 12 mV/ppm |
| Operating Condition | 100 ppm |
| Power Requirements | Low-voltage, low-power design |
| Compliance | Intrinsically Safe (IS) certified |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-113 |
| Detection Range | 0–20 ppm |
| LOD | 1.0 ppb |
| T90 | < 6.5 s |
| Typical Sensitivity | 118 mV/ppm |
| Measurement Condition | 10 ppm |
| Operating Voltage | Low-Voltage DC |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-114 |
| Detection Range | 4 ppm |
| LOD | 0.5 ppb |
| T90 | < 6.5 s |
| Typical Sensitivity | 545 mV/ppm |
| Measurement Condition | 1 ppm |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE PID-TECH eV-NXT |
| Pricing | Available Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-010 |
| Pricing | Available Upon Request |
| Certification | UL, CAN/CSA C22.2 No. 60079-0, ATEX II 2G Ex d [ia] IIC T4 Ga, IECEx Ex d [ia] IIC T4 Ga |
| Detection Range | 0–10,000 ppm isobutylene equivalent |
| Minimum Detectable Quantity (MDQ) | 500 ppb (isobutylene) |
| T90 Response Time | < 2 s (typical) |
| Lamp Lifetime | > 12,000 hours |
| Operating Temperature | –20 °C to +50 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Output Signal | 0–5 V DC analog |
| Power Supply | 5.0 V ±0.1 V DC |
| Ingress Protection | IP67-rated housing |
| Filter Configuration | Dual-stage particulate & hydrophobic membrane filter |
| Temperature Drift | < 0.05% FS/°C |
| Humidity Compensation | Electrode-based active suppression |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-011 |
| Price | Upon Request |
| Detection Range | 2,000 ppm |
| Minimum Detectable Quantity (MDQ) | 100 ppb |
| T90 Response Time | < 2 s (typical) |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Design | Intrinsically Safe, 4-Series Compatible Form Factor |
| Lamp Lifetime | Extended Operational Life |
| Temperature Sensitivity | Negligible |
| Humidity Compensation | Electrode-Based Suppression |
| Filtering | Dual-Stage Particle Protection |
| Signal Stability | Internal Linear Regulator Circuitry |
| Maintenance | Field-Serviceable, Cleanable Electrodes |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-013 |
| Price | Upon Request |
| Detection Range | 20 ppm |
| Minimum Detectable Quantity (MDQ) | 1.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Housing Color | Yellow |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Sensor Architecture | 4-Series Compatible |
| Lamp Type | Long-Life UV Lamp (10.6 eV) |
| Internal Regulation | Dual Linear Voltage Regulators |
| Filtration | Dual-Stage Particle Filter |
| Humidity Compensation | Electrode-Based Suppression |
| Thermal Drift | Negligible |
| Maintenance | Field-Serviceable & Cleanable |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-014 |
| Pricing | Available Upon Request |
| Detection Range | 2 ppm |
| Minimum Detectable Quantity (MDQ) | 0.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Certification | UL, CAN/CSA C/US, ATEX II 1G, IECEx Ex ia IIC T4 Ga |
| Sensor Architecture | 4-Series Compatible Form Factor |
| Lamp Life | > 12,000 hours |
| Operating Temperature Range | –20 °C to +50 °C |
| Humidity Compensation | Electrode-based suppression |
| Filtering | Dual-stage particulate protection |
| Power Supply | Internal linear regulation for signal stability |
| Maintenance | Field-serviceable, cleanable electrode assembly |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ |
| Detection Range | 0–2,000 ppm |
| Minimum Detectable Quantity (MDQ) | 10 ppb |
| T90 Response Time | < 2 s (typical) |
| Certifications | UL, CAN/CSA C22.2 No. 152, ATEX II 2G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga |
| Intrinsic Safety Design | Yes |
| Lamp Lifetime | > 12,000 hours |
| Operating Temperature | –20 °C to +50 °C |
| Humidity Compensation | Electrode-based humidity suppression |
| Dual-Stage Particle Filtration | Integrated |
| Signal Stability | Internal linear voltage regulation |
| Structural Compatibility | 4-Series electrochemical sensor footprint |
| Brand | BW |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FS20X |
| Price | Upon Request |
| Brand | BW |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FS24X |
| Pricing | Upon Request |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AAG-1000 |
| Negative Ion Output | ≥ 3 × 10⁶ pcs/cm³ |
| Residual Ozone Concentration | ≤ 0.05 ppm |
| Operating Voltage | 21–27 V DC |
| Operating Current | ≤ 30 mA |
| Output High Voltage | –3.5 ± 0.5 kV (1 G) |
| Protection Impedance | 20 ± 2 MΩ |
| Dielectric Withstand Voltage | ≥ 3750 V AC |
| Dimensions | 67.8 × 44.9 × 22 mm (W × H × D) |
| EMC Compliance | ISO 11452-4 & ISO 16750-2 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ACDS-1001 |
| Detection Principle | Dual-channel NDIR (Non-Dispersive Infrared) |
| Gas Measured | CO₂ |
| Measurement Range | 0–10,000 ppm (extended capability up to 40,000 ppm) |
| Resolution | 1 ppm |
| Accuracy | ±(50 ppm + 5% of reading) |
| Response Time (T90) | ≤25 s |
| Data Refresh Rate | ≤1 s |
| Output Interface | LIN bus |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +95 °C |
| Relative Humidity Range | 0–99% RH (non-condensing) |
| Operating Pressure | 80–120 kPa |
| IP Rating | IP54 |
| Supply Voltage | 9–16 VDC (nominal 12 VDC) |
| Average Current Consumption | ≤100 mA @ 12 VDC |
| Standby Current | <100 µA |
| Design Lifetime | 15 years |
| Compliance | AEC-Q200 qualified circuit architecture, automotive-grade EMI/EMC robustness |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AIS-3200 |
| Detection Gases | PM2.5 (0–1000 µg/m³), CO₂ (400–10,000 ppm) |
| PM2.5 Principle | Laser Scattering |
| CO₂ Principle | Single-Source NDIR with Dual-Channel Detection |
| PM2.5 Accuracy | ±15% of reading or ±15 µg/m³ (−20°C to +75°C, referenced to TSI 8530) |
| CO₂ Accuracy | ±100 ppm or ±10% (400–10,000 ppm, −20°C to +75°C) |
| PM2.5 Response Time (T90) | ≤12 s |
| CO₂ Response Time (T90) | ≤25 s |
| Warm-up Time | <10 s |
| Operating Temperature | PM2.5: −40°C to +75°C |
| CO₂ | −40°C to +85°C |
| Storage Temperature | −40°C to +95°C |
| IP Rating | IP65 |
| Dimensions | Compact, automotive-grade form factor |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM1002 |
| Detection Principle | Laser Scattering (PM) / Metal Oxide Semiconductor (VOC) |
| PM Range | 0–5000 µg/m³ |
| VOC Range | 0–10 ppm |
| PM1.0/PM2.5 Accuracy | ±10 µg/m³ (0–100 µg/m³), ±10% reading (101–500 µg/m³) |
| PM10 Accuracy | ±25 µg/m³ (0–100 µg/m³), ±25% reading (101–500 µg/m³) |
| VOC Accuracy | ±15% (@0.3–1 ppm), ±25% (@30 ppm) |
| Warm-up Time | ≤180 s (VOC) |
| Data Refresh Rate | 1 Hz |
| Operating Temp. | −20–60 °C |
| Operating RH | 0–95% RH (non-condensing) |
| Storage Temp./RH | −40–80 °C / 0–95% RH |
| Supply Voltage | DC 5 V ±0.5 V (ripple <50 mV) |
| Interfaces | UART (3.3 V/5 V), I²C (3.3 V/5 V) |
| Dimensions | 38 × 35 × 12 mm |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM1008 |
| Price | USD 72 (FOB) |
| PM2.5 Range | 0–1000 µg/m³ |
| CO₂ Range | 400–5000 ppm |
| VOC Scale | 0–3 (Relative Index) |
| Update Interval | 1 s |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −20 °C to +60 °C |
| Supply Voltage | DC 5 V ±0.1 V |
| Current Consumption | <300 mA |
| Communication Interfaces | UART-TTL, I²C |
| Dimensions | 80 × 50 × 13.6 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM1008L |
| Price | USD 34.50 (FOB) |
| Detection Principle | Laser Scattering (PM), Metal-Oxide Semiconductor (VOC) |
| Particle Size Resolution | 0.3 µm |
| PM Range | 0–1000 µg/m³ |
| VOC Range | 0–10 ppm |
| PM Accuracy | ±10 µg/m³ (≤100 µg/m³), ±10% RDG (>100 µg/m³) for PM1.0/PM2.5 |
| VOC Accuracy | ±0.25 ppm (0–1 ppm), ±25% RDG (1–10 ppm) |
| Refresh Rate | 1 s |
| Operating Temp. | −10 to +50 °C |
| Humidity Range | 5–95% RH (non-condensing) |
| Storage | −20 to +60 °C, 0–95% RH |
| Supply Voltage | DC 5 V ±0.2 V (ripple <100 mV) |
| Operating Current | ≤100 mA |
| Standby Current | ≤200 µA (SET pin low) |
| Interface | UART TTL @ 3.3 V logic level |
| Dimensions | 48 × 40 × 12 mm (W×H×D) |
| Shielding | Full-metal EMI shielding |
| Compliance | RoHS, CE-EMC, FCC Part 15 Subpart B |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM1009 |
| Detection Principles | Laser Light Scattering (PM), Metal Oxide Semiconductor (VOC, NOₓ, CO, HC) |
| PM Range | 0–5000 µg/m³ |
| VOC Range | 0–10 ppm |
| NO₂ Range | 0–10 ppm |
| PM Accuracy | ±10 µg/m³ (0–100 µg/m³), ±10% reading (101–500 µg/m³) for PM₁.₀/PM₂.₅ |
| Data Update Interval | 1 s |
| Power-On Stabilization Time | ≤180 s (VOC channel) |
| Operating Temp. | −10 to +60 °C |
| Operating RH | 5–95% RH (non-condensing) |
| Storage Temp./RH | −30 to +70 °C / 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.1 V, ripple <50 mV |
| Interfaces | UART (3.3 V / 5 V logic), I²C (5 V logic) |
| Dimensions | 50 × 38 × 21 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM1009CN |
| Detection Principles | Optical Scattering (PM2.5), Electrochemical/Semiconductor (CO), NTC Thermistor (Temperature) |
| Measurement Ranges | PM2.5: 0–5000 µg/m³ |
| CO | 0–1000 ppm |
| Temperature | −10–60 °C |
| Accuracy | PM2.5: ±20% of reading or ±200 µg/m³ |
| CO | ±30% of reading or ±40 ppm |
| Temperature | ±1 °C |
| Alarm Thresholds | PM2.5 ≥ 2000 µg/m³ |
| Data Update Interval | 1 s |
| Operating Conditions | −10–60 °C, 0–95% RH (non-condensing) |
| Storage Conditions | −30–70 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 12 V ± 0.5 V, Ripple < 100 mV |
| Average Current Consumption | < 100 mA |
| Output Interface | Digital Switch Output (configurable for CAN bus upon request) |
| Dimensions | 100 × 60 × 24.5 mm (W × H × D) |
| Minimum Detectable Particle Size | 0.3 µm |
| Sampling Method | Constant-Flow Aspiration |
| Calibration | Auto-compensated CO baseline correction |
| Compliance | RoHS-compliant design |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | AM1012 |
| Price | USD 72 (FOB) |
| Detection Parameters | PM2.5 (0–1000 µg/m³), CO₂ (400–2000 ppm), Temperature (−10°C to 50°C), Relative Humidity |
| Refresh Rate | 1 s |
| Power Supply | DC 12 V ±1 V |
| Current Consumption | <500 mA |
| Communication Interface | RS485 |
| Dimensions | 81.3 × 74.3 × 25.9 mm |
| EMC Performance | Built-in voltage regulation, ESD protection (>±8 kV contact discharge), conducted/radiated immunity compliant with IEC 61000-4 series |
| Operating Humidity Range | 0–95% RH non-condensing |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM1050 |
| Detection Range | ≥0.3 µm, 0–9,999,999 pcs/L |
| Output Channels | 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 µm |
| Counting Efficiency | 50% @ 0.3 µm |
| Operating Temperature | −30°C to +70°C |
| Storage Temperature | −40°C to +85°C |
| Supply Voltage | DC 5 V ±0.1 V or DC 9–36 V |
| Current Draw | <500 mA @ 5 V, <300 mA @ 9 V, <100 mA @ 36 V |
| Communication Interface | RS-485 / 4–20 mA (customizable) |
| Dimensions | 100 × 115 × 40 mm (W × D × H) |
| Compliance | JJF 1190–2008 Calibration Specification for Airborne Particle Counters |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM4203H |
| Pricing | Available Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Target Gases | R32, R454A, R454B, R454C, R290 (A2L & A3 refrigerants) |
| Measurement Range | 0–100% LFL |
| Accuracy | ±2.5% LFL (0–25% LFL), ±10% of reading (25–100% LFL) |
| Resolution | 0.1% LFL |
| Response Time (T90) | ≤30 s |
| Output Interfaces | RS485 Modbus RTU, Relay (dry contact) |
| Enclosure Rating | IP54 |
| Operating Temperature | −30 to +70 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −40 to +85 °C, 0–95% RH (non-condensing) |
| Power Supply | AC 18–36 V (24 V nominal, 55±8 Hz) or DC 12–36 V (24 V nominal) |
| Service Life | >15 years |
| Dimensions | 103.2 × 80 × 30.5 mm (customization available) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM4205 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Detection Range | 0–50% LFL |
| Resolution | 1% LFL |
| Accuracy | ±3.75% LFL |
| Data Refresh Rate | ≤1 s |
| Response Time (T90) | <30 s |
| Warm-up Time (T25) | ≤7 s |
| Output Options | UART / 0.8–4 V (default) / PWM (customizable) |
| Operating Temperature | −30 to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −30 to +70 °C / 0–95% RH (non-condensing) |
| Supply Voltage | 5 ± 0.1 V DC (ripple <50 mV) |
| Average Current Consumption | ≤150 mA |
| Peak Current | <300 mA |
| IP Rating | IP54 |
| Heating Function | Integrated self-heating element for anti-condensation and frost prevention |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM4207 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–50% LFL |
| Accuracy | ±5% LFL |
| Response Time (T50) | ≤10 s |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +85 °C |
| Humidity Range | 0–100% RH |
| Supply Voltage | DC 9–36 V |
| Current Consumption | <250 mA |
| Communication Interface | CAN bus |
| Protection Rating | IP67 (detector housing), IP65 (sensor head) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | AM4209 |
| Pricing | Available Upon Request |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Maximum Sensitivity | 1 g/year (static), 3 g/year (dynamic) |
| Refrigerant Compatibility | HFOs (e.g., 1234yf, 1234ze), A2L-class refrigerants, and common blends (R-134a, R-410A, R-32) |
| Alarm Output | Visual (red LED + LCD bar graph + numeric display), Audible (buzzer), Tactile (vibration) |
| Response Time | <1 second |
| Power Source | Rechargeable Lithium-ion Battery / 10-hour runtime |
| Display | Backlit LCD with real-time concentration readout |
| Operating Environment | 0°C to 40°C (32°F to 104°F), <75% RH (non-condensing) |
| Ingress Protection | IP54 |
| Key Features | High measurement accuracy, long-term stability, rapid response, poison-resistant sensor architecture, electromagnetic interference (EMI) robustness |