| Brand | CYSEA |
|---|---|
| Model | SC-A1 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | KD-BMIV, BLIV |
| Heating Zone Temperature Range | Ambient to 85 °C |
| Small Cold Plate Temperature Range | 30 to −15 °C |
| Main Cryo-Station Temperature Range | 30 to −35 °C |
| Temperature Control Accuracy | ±1 °C |
| Paraffin Reservoir Capacity | >6 L (495 × 132 × 95 mm) |
| Embedding Work Surface | 513 × 93 mm |
| Dual Preservation Boxes | 235 × 160 × 50 mm each |
| Cryo-Station Dimensions | 315 × 380 mm |
| Power Supply | AC 220 V ±10%, 50 Hz (standard) |
| Embedding Unit Power Consumption | 1000 VA |
| Cryo-Station Power Consumption | 100 VA |
| Overall Dimensions (Embedder) | 680 × 580 × 420 mm |
| Overall Dimensions (Cryo-Station) | 680 × 360 × 400 mm |
| Net Weight (Embedder) | 35 kg |
| Net Weight (Cryo-Station) | 25 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | KD-TS3S |
| Price | USD 12,500 (FOB) |
| Cylinder Count | 14 (10 reagent + 4 paraffin wax cylinders) |
| Single-Cylinder Capacity | 1500 mL |
| Temperature Range | Ambient to 80 °C |
| Temperature Accuracy | ±1 °C |
| Processing Time per Cylinder | Cylinders 1–2: up to 99 h 59 min |
| Cylinders 3–14 | 0–24 h |
| Drain/Blot Time | 10–60 s (adjustable, with surface draining & shaking) |
| Agitation Frequency | 0–6 cycles/min |
| Power Supply | AC 220 V ±10%, 50 Hz / AC 110 V ±10%, 60 Hz |
| Power Consumption | 550 VA |
| Dimensions (W×D×H) | 1250 × 430 × 490 mm |
| Weight | 85 kg |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | HistoCore Arcadia |
| Operating Temperature Range | 50–75 °C (1 °C increments) |
| Wax Bath Capacity | Up to 4 L |
| Tray Compatibility | ~150 cassettes (Peloris-compatible cassette baskets) |
| Display | 5.7-inch capacitive touchscreen LCD |
| Illumination | White LED |
| Power Supply | 100–120 VAC / 220–240 VAC, 50/60 Hz |
| Max Power Consumption | 1000 VA |
| Ambient Operating Temperature | +20 °C to +30 °C |
| Dimensions (D×W×H) | 636 × 560 × 384 mm |
| Weight | 27 kg |
| Optional Accessories | Ergonomic magnifier, liquid filtration module, footswitch |
| Cold Plate Function | Auto-regulated at −6 °C |
| Minimum Solidification Load | 65 paraffin blocks in 30 minutes |
| Cold Plate Dimensions | 155 × 80 × 100 mm |
| Cold Plate Weight | ~1.5 kg |
| Cold Plate Ambient Range | +15 °C to +40 °C |
| Brand | STEMCELL Technologies |
|---|---|
| Origin | Canada |
| Model | STEMprep™ |
| Temperature Range | 4–37°C (integrated heating & cooling) |
| Throughput Options | 4-, 8-, or 12-sample modular configurations |
| Compliance | Designed for GLP-compliant workflows |
| Software Interface | Touchscreen-based protocol management system |
| Sample Tube Compatibility | STEMprep™-specific consumable tubes with integrated agitation and thermal control |
| Brand | Ted Pella |
|---|---|
| Origin | USA |
| Model | 36500-230 |
| Microwave Power | 100–750 W (1 W increments) |
| Frequency | 2.45 GHz |
| Temperature Control Accuracy | ±1 °C (aqueous samples) |
| Time Range | 1 s – 96 h |
| Vacuum Capacity | 20 inHg (three programmable modes) |
| Integrated Water-Cooling Flow | 1.5 L/min |
| Internal Magnetic Stirring | 0–3000 rpm |
| Touchscreen Interface | 7″ industrial-grade capacitive touchscreen |
| Method Storage | Up to 204-step protocols |
| Dimensions (W×D×H) | 553 × 514 × 546 mm |
| Weight | 37 kg |
| Certifications | ETL, CE |
| Voltage | 230 V, 10 A |
| Brand | Ted Pella |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioWave® Pro |
| Microwave Power Range | 100–750 W (continuous, non-pulsed) |
| Microwave Frequency | 2.45 GHz |
| Power Control | Programmable controller with 10 user-modifiable presets |
| Interface | 6" touchscreen |
| Temperature Accuracy | ±1°C (for most aqueous solutions) |
| Internal Cooling | Integrated ambient water cooling |
| External Cooling (optional) | PELCO SteadyTemp™ (450 W chilled cooling) |
| Magnetic Stirrer | Integrated, 0–300 rpm |
| Exhaust Capacity | 110 cfm |
| Venting | Automatic upon door opening |
| Vacuum System | 20" Hg, 3 selectable modes |
| Air Bubbler | Up to 0.8 L/min at 2.5" water column pressure |
| Protocol Storage | Up to 200-step protocols |
| Certification | ETL, CE |
| Brand | Ted Pella |
|---|---|
| Origin | USA |
| Model | 13000 |
| Module Configuration | PELCO Warmer™, PELCO Chiller™, PELCO Freezer™ |
| Cooling/Heating Technology | Solid-state thermoelectric (Peltier) |
| Capacity | Up to 260 standard blocks (20 per tray × 13 trays) or 78 oversized blocks (6 per tray × 13 trays) |
| Compliance | RoHS-compliant thermal management, no CFCs or hydrocarbon refrigerants |
| Regulatory Context | Designed for GLP-compliant histopathology workflows |
| Brand | UNITMA |
|---|---|
| Origin | South Korea |
| Model | UATM-272A |
| Power Supply | 110–220 V, 50–60 Hz, 660 W |
| Dimensions (W×D×H) | 890 × 650 × 500 mm |
| Weight | 148 kg |
| Donor Block Capacity | 10 blocks |
| Recipient Block Capacity | 2 blocks |
| Core Tip Diameters | 1 mm, 2 mm, 3 mm (rotary tip module) |
| Punch Cycle Time | ~15 s per core transfer (extraction + insertion) |
| Display | 12.1″ LCD touch screen (1024 × 768) |
| Camera Resolution | Camera 1: 1280 × 1024 px |
| Camera 2 | 2592 × 1944 px |
| OS | Windows 10 |
| Certifications | UL, CE, FCC, ISO 13485 |
| Recipient Blocks | Proprietary high-melting-point paraffin blocks (UNITMA-exclusive) |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS-1145 |
| Price | USD 1,320 (FOB) |
| Temperature Range | Ambient to 90 °C (independent control for floating, drying, and baking zones) |
| Floating Bath Volume | 135 mm × 185 mm × 80 mm |
| Dimensions (W×D×H) | 510 mm × 340 mm × 220 mm |
| Weight | 16 kg |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 1000 W |
| Drying Rack Capacity | 70 microscope slides (60° inclined insertion) |
| Baking Chamber Capacity | 3 standard staining racks (30–40 slides each) or two 250 mL beakers for paraffin melting |
| Brand | ZEEDO |
|---|---|
| Model | HS-CC01 |
| Construction | 0.8 mm cold-rolled steel (Baosteel) |
| Finish | Electrostatic powder coating with anti-rust pretreatment |
| Drawer System | 4 modular units × 5 full-extension drawers = 20 drawers total |
| Capacity | ~16,000 paraffin blocks (standard 30 × 25 × 5 mm) |
| Drawer Guidance | Heavy-duty槽-type roller track system with dual-position high-strength nylon rollers |
| Safety Features | Auto-return drawer mechanism, integrated high-elasticity shock-absorbing pads at drawer front edge |
| Dimensions (W × D × H) | 480 × 515 × 1510 mm per unit |
| Origin | Beijing, China |
| Compliance | Designed for GLP-compliant histopathology laboratories |
| Brand | ZEEDO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TH-701 |
| Price | USD 4,950 (FOB Beijing) |
| Construction Material | 304 Stainless Steel (1.2 mm thickness) |
| Dimensions (L×W×H) | 1500 × 800 × 1900 mm |
| Net Weight | 215 kg |
| Exhaust Airflow | ≥1600 m³/h |
| Work Surface Incline | ≥7° |
| Water Supply System | Dual-temperature (hot/cold), PPR piping, articulating metal hose faucet |
| Drainage | PE corrosion-resistant piping with integrated stainless steel filter basket |
| Ventilation Configuration | Waist-level negative-pressure suction or optional under-bench downdraft system |
| Lighting | High-lumen LED task illumination |
| Optional Accessories | HD digital imaging module with 1080p display, touchless hand dryer, ANSI-compliant wall-mounted eyewash station, integrated tissue shredder unit |