Leici SFK-503C Coulometric Karl Fischer Moisture Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Leici
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Instrument Type Coulometric Karl Fischer Moisture Analyzer
Titration Method Fully Automatic
Moisture Measurement Range 10.0 µg – 200 mg
Resolution 0.1 µg
Repeatability ≤1%
Electrolysis Current Stability ±0.2% / 10 min
Polarization Current Error ±3%
Polarization Current Stability ±2.5% / 30 min
Potential Measurement Range 0–2000 mV
Potential Resolution 0.1 mV
Power Supply 100–240 VAC, 47–63 Hz
Dimensions (L×W×H) 240 × 370 × 270 mm
Weight ~3 kg
Data Storage Capacity 200 measurement records
Interface Support RS-232 (printer), USB (scanner, moisture control software, U-disk export), optional KF oven coupling

Overview

The Leici SFK-503C is a fully automated coulometric Karl Fischer (KF) moisture analyzer engineered for high-precision quantification of trace water content in solid, liquid, and gaseous samples. Unlike volumetric KF systems that rely on standardized titrant delivery, the SFK-503C employs electrochemical generation of iodine at the anode via controlled electrolysis—enabling direct, stoichiometric quantification of water according to the classic Karl Fischer reaction: H₂O + I₂ + SO₂ + 3RN + CH₃OH → 2RN·HI + RN·HSO₄CH₃. This coulometric principle delivers inherent accuracy and sensitivity down to 0.1 µg absolute water mass, with no need for daily standardization of titrant concentration. The instrument is designed for routine QC laboratories, pharmaceutical R&D, polymer synthesis labs, and battery electrolyte quality control—where regulatory compliance, operator safety, and data integrity are non-negotiable.

Key Features

  • 7-inch full-color capacitive touchscreen interface with intuitive icon-driven navigation and real-time graphical display of titration curves, current profiles, and endpoint detection status.
  • Dual operational modes: standalone coulometric titration and integrated KF oven coupling (via optional heated sample furnace) for thermally released moisture from hygroscopic or insoluble solids (e.g., APIs, excipients, metal oxides).
  • Comprehensive safety architecture: solvent manager with anti-leak design, waste bottle anti-siphon valve, and sealed reagent handling pathways—minimizing user exposure to toxic KF reagents (e.g., pyridine-free methanol-based electrolytes).
  • Multi-mode measurement protocol support: automatic titration, oven-assisted analysis, blank correction, and factor calibration—ensuring adaptability across heterogeneous sample matrices without manual method reconfiguration.
  • GLP-compliant data governance: password-protected user management (up to 8 accounts), audit-trail-enabled operation logs, electronic signatures, and timestamped storage of raw data, method parameters, and calibration history (200 entries retained onboard).
  • Flexible reporting infrastructure: native support for µg, mg, %, ppm, µg/L, and mg/L output units; direct thermal printer output via RS-232; USB export to FAT32-formatted drives; and bidirectional communication with Leici’s dedicated moisture control software for trend analysis and 21 CFR Part 11–ready report generation.

Sample Compatibility & Compliance

The SFK-503C accommodates a broad spectrum of sample types—including viscous oils, powders, granules, films, solvents, and compressed gases—when paired with appropriate sampling accessories (e.g., gas-tight syringes, oven adapters, or headspace vials). Its coulometric cell design ensures stable baseline performance even with low-conductivity solvents (e.g., chloroform, toluene), while the adjustable polarization current (0–2000 mV range, 0.1 mV resolution) enables optimization for reactive or inert matrices. The system conforms to ISO 8533:2017 (determination of water by coulometric KF titration), ASTM E203–22 (standard test method for water using KF titration), and supports validation protocols aligned with USP , EP 2.5.12, and ICH Q5C guidelines. All firmware operations comply with GLP requirements for instrument qualification (IQ/OQ/PQ), including electronic record retention, user access control, and change management logs.

Software & Data Management

Leici’s proprietary moisture control software provides secure, encrypted USB-based synchronization with the SFK-503C. It enables remote method deployment, batch-level result review with statistical summaries (mean, SD, RSD), customizable report templates (PDF/CSV/XLSX), and automated backup to network drives. The software implements role-based permissions, digital signature capture for critical actions (e.g., calibration approval), and full 21 CFR Part 11 compliance—including electronic audit trails, system usage logs, and tamper-evident data packaging. Raw electrochemical signals (current vs. time, potential vs. time) are preserved alongside processed results, facilitating root-cause analysis during out-of-specification investigations.

Applications

  • Pharmaceuticals: Water content verification in active pharmaceutical ingredients (APIs), lyophilized powders, and excipients per USP limits.
  • Battery Materials: Quantification of residual moisture in Li-ion cathode precursors (e.g., NMC, LFP) and electrolyte solvents—critical for cell stability and SEI formation.
  • Polymers & Plastics: Monitoring moisture in PET, PA6, PC, and PBT prior to extrusion or injection molding to prevent hydrolytic degradation.
  • Fine Chemicals: Release testing of catalysts, organometallic reagents, and specialty solvents where sub-100 µg water levels impact reaction yield.
  • Food & Feed: Validation of drying efficiency in dairy powders, starch derivatives, and pet food formulations under AOAC 992.13–compatible workflows.

FAQ

What distinguishes coulometric from volumetric Karl Fischer titration?
Coulometric KF generates iodine electrochemically in situ, enabling precise quantification of water down to 0.1 µg without standardized titrant. Volumetric KF uses pre-prepared iodine-containing solutions and is better suited for higher water concentrations (>100 µg).

Can the SFK-503C be used with a KF oven?
Yes—the instrument features dedicated oven interface logic and timing control for seamless integration with Leici’s optional heated sample furnace (SFK-OV series), supporting temperature-programmed moisture release up to 300 °C.

Is the system compliant with FDA 21 CFR Part 11?
When operated with Leici’s validated moisture control software and configured with enabled audit trail, electronic signatures, and user authentication, the SFK-503C meets core technical requirements of 21 CFR Part 11 for electronic records and signatures.

How is reagent consumption managed to ensure long-term stability?
The solvent manager incorporates dual-level fluid level sensing, overfill prevention, and pressure-balanced venting—reducing evaporation loss and maintaining consistent electrolyte conductivity over extended runs (≥500 determinations per 100 mL anolyte/catholyte).

What maintenance is required for routine operation?
Daily: electrode cleaning with dry tissue and solvent rinse; weekly: cathode chamber inspection and desiccant replacement in oven interface lines; annually: full system verification using certified water standards (e.g., 1.00 ± 0.02 mg H₂O/ampoule).