Alpha DSP-Ex Portable Intrinsically Safe Dew Point Meter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand ALPHA
Origin United Kingdom
Manufacturer Type Authorized Distributor
Product Origin Imported
Model DSP-Ex
Product Category Portable Dew Point Meter
Measurement Principle Electrolytic (P2O5 Sensor)
Accuracy ±2 °C dew point
Certification ATEX Ex ia IIC T3/T4
Operating Pressure Ambient (101.3 kPa ±10%)
Dew Point Range –110 °C to +20 °C
Battery Life >250 hours continuous operation
Power Source Two C-cell alkaline batteries
Display Units °C, °F, ppm(v), ppb(v), ppm(w), g/m³, lb/MMSCF
Gas Compatibility Air, Ar, H₂, SF₆, CO₂, N₂ (custom molecular weight input supported for ppm(w))
Sensor Interchangeability Fully field-replaceable with traceable calibration
Calibration Certificate UKAS-traceable to NPL and international humidity standards
Sampling Interface Stainless steel quick-connect fitting + integrated desiccant drying chamber
Accessories Included 2 m PTFE-braided stainless steel sampling hose, anti-static carry case, user manual, factory calibration certificate

Overview

The Alpha DSP-Ex Portable Intrinsically Safe Dew Point Meter is a field-deployable, electrolytic (phosphorus pentoxide, P2O5) based humidity analyzer engineered for high-reliability dew point measurement in hazardous and non-hazardous environments. Unlike chilled-mirror or capacitive hygrometers, the DSP-Ex employs a dual-electrode P2O5 sensor that quantifies water vapor concentration via controlled electrolysis—measuring the current required to decompose adsorbed H2O molecules into hydrogen and oxygen. This principle delivers stable, linear response across an exceptionally wide dew point range of –110 °C to +20 °C at ambient pressure, making it suitable for critical applications in compressed air systems, natural gas dehydration, SF6 switchgear monitoring, semiconductor purge gas verification, and cryogenic process validation.

Key Features

  • Intrinsically safe design certified to ATEX Ex ia IIC T3/T4 — fully operational in Zone 0/1 without external barriers or purging systems
  • Integrated desiccant drying chamber and stainless steel quick-connect sampling interface enable sub-60-second stabilization for repeatable spot measurements
  • dewSMART™ digital signal processing architecture ensures long-term baseline stability and minimizes drift-induced recalibration frequency
  • Field-swappable P2O5 sensor module — no instrument return required; calibration validity maintained via embedded sensor ID and NIST-traceable coefficient tables
  • Multi-unit display support: °C, °F, ppm(v), ppb(v), ppm(w), g/m³, and lb/MMSCF — with programmable molecular weight input for accurate mass-based concentration calculation on non-standard gases
  • Self-diagnostics at power-on, auto-ranging, auto-shutdown after 15 minutes of inactivity, and high-contrast LCD with backlight for low-light conditions
  • Powered by two standard C-cell alkaline batteries delivering >250 hours of continuous operation under typical field use conditions

Sample Compatibility & Compliance

The DSP-Ex is validated for use with dry, non-corrosive, non-condensing gas streams including compressed air, nitrogen, argon, hydrogen, carbon dioxide, and sulfur hexafluoride. For gases outside this predefined list, users may enter the molecular weight to enable correct conversion from volumetric (ppm(v)) to gravimetric (ppm(w)) units — essential for compliance with ISO 8573-1:2010 Class 2–4 purity specifications or ASTM D6673 for SF6 moisture content. The instrument meets EN 60079-0, EN 60079-11, and IEC 60079-26 for intrinsic safety, and its calibration certificate is traceable to the UK’s National Physical Laboratory (NPL) and aligned with ISO/IEC 17025 requirements. While not designed for continuous online installation, its portability supports periodic verification audits required under ISO 9001, ISO 14001, and pharmaceutical GMP Annex 1 environmental monitoring protocols.

Software & Data Management

The DSP-Ex operates as a standalone instrument with no embedded data logging or PC connectivity. All measurement data are displayed in real time and retained only in volatile memory until power-off. For quality assurance documentation, users record readings manually or integrate the device into structured audit workflows using external logging tools. The included UKAS-traceable calibration certificate satisfies GLP/GMP documentation requirements for instrument qualification (IQ/OQ), and the sensor’s interchangeability supports documented change control procedures per FDA 21 CFR Part 11 when paired with compliant electronic lab notebooks (ELNs). No firmware updates or software drivers are required — operation is entirely hardware-defined and deterministic.

Applications

  • Verification of desiccant dryer performance in industrial compressed air networks (ISO 8573-1 Class 2–4)
  • Moisture monitoring in SF6 insulated high-voltage switchgear per IEC 60480 and IEEE C37.122.1
  • Pre-commissioning validation of pipeline drying in natural gas transmission (ASTM D1148, GPA 2172)
  • Quality control of inert purge gases used in lithium-ion battery manufacturing and semiconductor wafer fabrication
  • Field verification of cryogenic dew point sensors during LNG plant commissioning
  • Periodic auditing of cleanroom nitrogen supply systems in pharmaceutical aseptic processing suites

FAQ

Is the DSP-Ex suitable for continuous unattended operation?
No — it is a portable, operator-activated instrument intended for periodic spot checks. It lacks internal data storage, analog outputs, or alarm relays required for permanent installation.
Can the sensor be calibrated in the field without sending the unit to a service center?
Yes — the P2O5 sensor is fully interchangeable; replacement modules ship pre-calibrated with embedded coefficients. No instrument-level recalibration is needed.
Does the DSP-Ex require zero or span gas for routine verification?
Not routinely — the electrolytic sensor is inherently zero-stable. Optional verification using NIST-traceable moisture standards (e.g., chilled mirror reference) is recommended annually or after sensor replacement.
What pressure range is supported?
The DSP-Ex is specified for operation at ambient atmospheric pressure (101.3 kPa ±10%). It is not rated for pressurized line sampling; a pressure regulator and flow controller must be used upstream if sampling from pressurized systems.
How is traceability to national standards documented?
Each unit ships with a UKAS-accredited calibration certificate referencing NPL humidity standards (ISO/IEC 17025:2017 accredited laboratory), including uncertainty budgets at key dew point points (–70 °C, –40 °C, +20 °C).