Empowering Scientific Discovery

JB-60L Small-Scale VOC Environmental Test Chamber (Single Chamber)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Jiubin Instruments
Origin Shanghai, China
Manufacturer Type Authorized Distributor
Country of Origin China
Model JB-60L
Pricing Upon Request

Overview

The JB-60L Small-Scale VOC Environmental Test Chamber is a single-compartment, precision-controlled environmental enclosure engineered for standardized emission testing of volatile organic compounds (VOCs) from building materials, furniture, automotive interior components, and consumer products. It operates on the principle of dynamic chamber testing per ISO 16000-9, ASTM D5116, and GB/T 18883–2022, maintaining stable temperature (23 ± 0.5 °C), relative humidity (50 ± 3 % RH), air exchange rate (0.5–2.0 h⁻¹, adjustable via mass flow controllers), and background VOC concentration (<0.5 µg/m³ total VOC). Its 60-liter internal volume provides optimal surface-area-to-volume ratio for small-sample evaluation while ensuring laminar airflow distribution and minimal wall adsorption effects—critical for high reproducibility in low-emission material qualification.

Key Features

  • Stainless-steel 316L inner chamber with electropolished finish and welded seams to minimize VOC adsorption and enable rigorous cleaning protocols.
  • Integrated PID-controlled heating/cooling system with dual-stage refrigeration and PTC ceramic heaters for precise thermal regulation (±0.3 °C stability over 24 h).
  • Dual independent humidity control: chilled-mirror dew-point sensor + ultrasonic humidifier with deionized water recirculation and auto-drain function.
  • Mass flow-controlled ventilation using calibrated thermal mass flow meters (±1 % FS accuracy) and low-outgassing stainless-steel tubing.
  • Real-time monitoring of chamber conditions via embedded RS-485 interface; optional analog outputs (4–20 mA) for integration into centralized lab control systems.
  • Compliant with ISO/IEC 17025 documentation requirements: full audit trail for setpoint changes, calibration logs, and environmental deviations.

Sample Compatibility & Compliance

The JB-60L accommodates flat or modular samples up to 300 mm × 300 mm × 50 mm (L×W×H), mounted on inert PTFE-coated sample holders. It supports standardized test substrates including glass, aluminum, and low-VOC MDF per ISO 16000-11. Chamber validation includes blank run verification, recovery tests using certified VOC standards (e.g., toluene, formaldehyde, n-hexane), and inter-laboratory comparison reports aligned with CNAS-CL01:2018. The system meets preconditions for GLP-compliant studies and serves as a validated platform for product development under China’s Green Building Evaluation Standard (GB/T 50378) and EU Ecolabel criteria.

Software & Data Management

The chamber interfaces with optional PC-based control software (JB-ChamberControl v3.2) supporting automated test sequencing, real-time graphing of T/RH/flow parameters, and CSV export of time-stamped environmental logs. All data files are timestamped and digitally signed, enabling traceability per FDA 21 CFR Part 11 requirements when configured with user authentication and electronic signature modules. Audit trails record operator ID, parameter modifications, alarm events, and calibration interventions—retained for ≥12 months and exportable for regulatory submission.

Applications

  • Pre-market screening of adhesives, sealants, paints, and coatings per ISO 16000-3 and EN 13419-1.
  • Evaluation of low-VOC claims for automotive cabin materials (dashboards, seat fabrics, headliners) in accordance with VDA 278 and Ford WSS-M99P1165-A.
  • Supporting indoor air quality (IAQ) assessments for LEED v4.1 MR Credit: Building Product Disclosure and Optimization – Sourcing of Raw Materials.
  • Method development and validation for GC-MS/FID analysis of chamber effluent gases.
  • Research on emission kinetics, aging effects, and temperature/humidity-dependent VOC release profiles in academic and industrial laboratories.

FAQ

What standards does the JB-60L chamber comply with for VOC emission testing?
It is designed to support ISO 16000-9, ASTM D5116, ASTM D6670, GB/T 18883–2022, and JIS A 1912, with optional validation kits available for ISO 16000-10 chamber certification.
Can the chamber be integrated with online GC-MS or PTR-TOF systems?
Yes—equipped with standardized 6-mm Swagelok ports and pressure-rated sampling lines, it supports direct coupling to real-time analyzers via heated transfer lines (up to 120 °C) and flow-splitting manifolds.
Is third-party calibration and IQ/OQ/PQ documentation available?
Jiubin Instruments provides factory-issued IQ/OQ protocols; PQ validation support—including uncertainty budgeting and GUM-compliant reporting—is available through authorized service partners accredited to ISO/IEC 17025.
What maintenance is required to ensure long-term measurement integrity?
Quarterly verification of temperature/humidity sensors against NIST-traceable references, biannual cleaning of humidifier reservoirs and condensate traps, and annual recalibration of mass flow controllers are recommended per the operation manual.