Isopropanol Dispensing Bottle with PTFE (FEP) Construction, 500 mL Graduated, Model A-MFG-TPC-5%-001 for Semiconductor IC Manufacturing
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Capacity | 500 mL |
| Pricing | Upon Request |
Overview
The A-MFG-TPC-5%-001 is a high-purity, chemically inert dispensing bottle engineered specifically for critical fluid handling in semiconductor front-end fabrication and ultra-trace analytical laboratories. Constructed entirely from fluorinated ethylene propylene (FEP)—a subclass of perfluoroalkoxy (PFA)-grade fluoropolymers—the bottle delivers exceptional resistance to aggressive solvents including isopropanol (IPA), acetone, piranha solution, hydrofluoric acid (HF) dilutions, and high-purity deionized water. Unlike standard HDPE or LDPE dispensers, FEP exhibits near-zero extractables, negligible leachables, and maintains structural integrity across a wide thermal range (–200 °C to +205 °C), making it compliant with SEMI F57 and ASTM D4808 specifications for high-purity chemical packaging. Its calibrated 500 mL volume features laser-etched graduations traceable to NIST-certified standards, ensuring volumetric repeatability within ±0.5% at 20 °C—essential for controlled solvent delivery during photolithography rinse steps, wafer surface conditioning, and cleaning validation protocols.
Key Features
- FEP (fluorinated ethylene propylene) monolithic construction—no adhesives, welds, or metal components—to eliminate particle generation and metallic contamination.
- Narrow-neck design with precision-matched thread geometry compatible with standard laboratory reagent bottle caps (DIN 16913, ISO 838), enabling secure integration into automated dispensing stations and glovebox feedthroughs.
- Laser-engraved, permanent volume markings (0–500 mL in 50 mL increments) resistant to abrasion, chemical etching, and autoclave cycling.
- Autoclavable up to 121 °C / 15 psi; requires full cap loosening prior to sterilization to prevent pressure-induced deformation or seal failure.
- Low extractable profile validated per USP and SEMI C38 for total organic carbon (TOC) release < 0.5 ppb after 72-hr IPA soak at 25 °C.
- Designed for Class 10 (ISO 4) cleanroom assembly and double-bagged in static-dissipative polyethylene with particle-count certification (≤10 particles ≥0.5 µm per cubic foot).
Sample Compatibility & Compliance
The A-MFG-TPC-5%-001 is qualified for direct contact with high-purity isopropanol (≥99.999% metals basis), methanol, ethanol, ethyl acetate, and aqueous ammonium hydroxide solutions used in IC cleaning processes. It conforms to SEMI F17 (specifications for plastic containers for bulk chemicals), SEMI F57 (cleanliness requirements for semiconductor process chemicals), and meets the material compatibility criteria outlined in IEC 60068-2-66 for thermal shock testing. The FEP resin lot is certified per ASTM D4808 (standard specification for fluoropolymer resins) and supplied with full CoA including elemental impurity screening (ICP-MS) for Na, K, Fe, Ni, Cr, Al, Cu, Zn, and Ca—all reported below 10 ppt.
Software & Data Management
While the A-MFG-TPC-5%-001 is a passive fluid containment device, its model number (A-MFG-TPC-5%-001) follows the Binzhenghong Traceability Protocol Code (TPC) architecture. Each unit carries a unique 2D data matrix code laser-marked on the base, linking to a secure cloud-based manufacturing log containing resin batch ID, extrusion date, cleanroom assembly shift record, particulate scan report (per ISO 14644-1), and final TOC/ICP-MS verification. This audit trail supports FDA 21 CFR Part 11 compliance when integrated into QMS platforms such as TrackWise or MasterControl for GMP-regulated wafer fab environments.
Applications
- Dispensing of ultra-high-purity isopropanol in photomask cleaning and post-lithography develop rinse stages.
- Storage and transfer of HF/NH4OH mixtures (e.g., SC1, SC2) in wet bench stations.
- Calibrated solvent addition during analytical method development for IC surface residue analysis (e.g., TOC, ion chromatography).
- Trace-metal-free reagent handling in ICP-MS sample preparation labs requiring sub-ppt contamination control.
- Integration into semi-automated wafer scrubbers where consistent flow rate and low particle shedding are mandatory.
FAQ
Can this bottle be used for hydrofluoric acid (HF) solutions?
Yes—FEP demonstrates excellent resistance to HF concentrations up to 49% at ambient temperature; however, extended exposure >72 hours requires validation per your internal chemical compatibility matrix.
Is the graduation scale certified for metrological traceability?
Yes—each bottle’s刻度 (graduation) is verified against NIST-traceable glass volumetric standards during final inspection; calibration certificate available upon request.
Does the narrow neck support standard pipette tip insertion?
The orifice diameter is 8.5 mm, accommodating most universal positive-displacement pipette tips and PTFE-coated syringe needles without interference.
What is the maximum recommended fill level for safe pressurized dispensing?
For optimal ergonomic control and drip-free operation under manual squeeze pressure, maintain liquid level between 20% and 80% of total capacity.
How is particulate cleanliness verified before shipment?
Each batch undergoes ISO 14644-1 Class 4 cleanroom rinsing with 18.2 MΩ·cm DI water, followed by filtration through 0.1 µm PTFE membranes and light-scattering particle counting per USP .