YL-S90 Yuelian Electronic Tensile Testing Machine for Pressure-Sensitive Adhesive Tape Peel Strength Measurement
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-S90 |
| Maximum Test Load | 1 kN |
| Load Range | 100% FS |
| Load Accuracy | ±0.5% |
| Test Stroke | 450 mm |
| Displacement Resolution | 0.01 mm |
| Force Resolution | 1/120,000 full scale |
| Speed Range | 0.5–600 mm/min (computer-controlled) |
| Travel Width | 55 mm |
| Power Supply | 220 V, 50/60 Hz, 10 A |
| Dimensions (W×D×H) | 400 × 300 × 700 mm |
| Weight | ~28 kg |
| Interface | RS-232 |
| Compliance | ASTM D3330, ASTM D1000, ISO 29862, GB/T 2792, JIS Z 0237 |
Overview
The YL-S90 Yuelian Electronic Tensile Testing Machine is a precision-engineered instrument designed specifically for quantitative mechanical evaluation of pressure-sensitive adhesive (PSA) tapes and related flexible laminates. It operates on the fundamental principle of uniaxial tensile force application under controlled displacement rate, enabling standardized measurement of peel strength, tack, shear resistance, cleavage, and release (liner) forces in accordance with internationally recognized test protocols. The system employs a high-stiffness frame, stepper motor-driven motion control, and a precision-ground ball screw transmission to ensure repeatable load application and minimal mechanical hysteresis. Its modular architecture supports rapid fixture interchangeability, facilitating seamless transitions between 90° and 180° peel configurations, loop tack, and shear hold tests — all critical for R&D, QC, and regulatory documentation in adhesive manufacturing, packaging, medical device labeling, and electronics assembly.
Key Features
- Computer-controlled test speed (0.5–600 mm/min) with programmable ramp profiles and real-time feedback
- High-resolution load sensing (1/120,000 full scale) and displacement resolution of 0.01 mm
- Auto-return function upon test completion, with configurable upper/lower limit stops and overload protection
- Quick-release modular fixture interface compatible with standard ASTM/ISO-compliant grips, peel arms, and shear fixtures
- RS-232 serial communication for direct integration with Windows-based data acquisition and analysis software
- Dual-capacity load cell option (e.g., 100 N / 1 kN) to optimize signal-to-noise ratio across low-force tack and high-force shear regimes
- Integrated emergency stop, specimen rupture auto-stop, and hardware-level current-limiting safeguards
Sample Compatibility & Compliance
The YL-S90 accommodates PSA tapes, transfer adhesives, labels, protective films, and release liners with widths up to 55 mm and total thicknesses ≤ 2.5 mm. It supports both rigid (e.g., stainless steel, aluminum) and flexible (e.g., PET, PP, paper) substrates per ASTM D3330 Method A (180° peel), Method B (90° peel), and ASTM D1000 for tape adhesion to low-energy surfaces. The system meets essential requirements for GLP-compliant laboratories: audit-trail-enabled software logging, user-access-level controls, and timestamped raw data export (CSV, TXT). While not certified to ISO/IEC 17025 out-of-the-box, its mechanical repeatability (≤±0.5% load accuracy, ≤0.01 mm displacement linearity) aligns with calibration traceability frameworks required by ISO 17025-accredited facilities when paired with accredited load cell verification.
Software & Data Management
The included PC-based software provides real-time plotting of force vs. displacement curves, automatic peak detection for peel initiation and steady-state regions, and statistical reporting (mean, SD, CV%, min/max) across multi-sample batches. Raw data files retain full temporal resolution (≥100 Hz sampling) and support post-test reanalysis including modulus calculation (initial slope), energy-to-peel (area under curve), and failure mode annotation. Export formats include CSV for Excel-based QA reporting and PDF for internal SOP documentation. Software complies with FDA 21 CFR Part 11 functional expectations — including electronic signatures, change history logs, and password-protected method editing — though formal validation must be performed by end users per organizational validation protocols.
Applications
- Quantitative peel strength validation for medical transdermal patches and surgical tapes (per ISO 29862)
- Release liner characterization in lithium-ion battery electrode manufacturing
- QC screening of acrylic vs. rubber-based PSAs in label stock production
- Shear adhesion retention (SAR) testing at elevated temperatures (when used with environmental chamber add-ons)
- Comparative analysis of surface energy effects on adhesion using standardized test panels (e.g., glass, stainless steel, HDPE)
- Supporting root-cause investigations during adhesive delamination failures in automotive trim assembly
FAQ
What standards does the YL-S90 directly support?
ASTM D3330 (peel adhesion), ASTM D1000 (adhesion to low-energy surfaces), ISO 29862 (medical PSA tapes), GB/T 2792 (Chinese national standard for peel strength), and JIS Z 0237 (Japanese industrial standard for pressure-sensitive tapes).
Can the system perform creep or stress-relaxation tests?
No — the YL-S90 is configured for quasi-static tensile and peel modes only; dynamic or time-dependent viscoelastic characterization requires a dedicated rheometer or servo-hydraulic tester.
Is third-party calibration certification included?
The base configuration includes factory calibration documentation; NIST-traceable certificate issuance requires optional paid service at time of order or annual recalibration via authorized metrology labs.
What is the maximum recommended sample width for reliable 180° peel measurements?
55 mm, as defined by the standard test width in ASTM D3330 and ISO 29862; wider specimens may induce edge effects and require custom tooling.
Does the software support automated pass/fail decision logic based on specification limits?
Yes — tolerance bands can be defined per test method, triggering visual alerts and flagging outliers in batch summary reports.