Brand GreenPrima
Origin United Kingdom
Manufacturer Type Original Equipment Manufacturer (OEM)
Product Category Imported Instrument
Model PM8202I
Price Upon Request
Measurement Range 0.00–20,000 ppm Ca²⁺ (as CaCO₃ equivalent)
Resolution 0.01 / 0.1 / 1 ppm (user-selectable)
Accuracy ±0.01 ppm (≤10 ppm), ±0.1 ppm (10–100 ppm), ±1 ppm (>100 ppm)
Temperature Compensation –10 to +130 °C (NTC30K or PT1000 sensor input, manual/automatic)
Operating Temperature –10 to +70.0 °C
Storage Temperature –20 to +70.0 °C
Display Backlit dot-matrix LCD with real-time Ca²⁺ concentration, temperature, timestamp, and relay status
Data Storage Capacity 600,000 records
Power Supply 90–260 VAC, 50/60 Hz or optional 24 VDC
Isolated Analog Outputs Two 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for Ca²⁺ or temperature)
Communication Protocol RS485 Modbus RTU
Cleaning Control Output Adjustable interval (0.1–1000 h) and duration (1–1000 s)
Alarm Outputs Two independent Hi/Lo relays (5 A / 250 VAC / 30 VDC), with user-defined hysteresis
Enclosure Rating IP65
Mounting Options Wall-mount, pipe-mount, panel-mount
Dimensions (W×H×D) 144 × 144 × 108 mm
Panel Cutout 138 × 138 mm
Weight 0.87 kg

Overview

The GreenPrima PM8202I Calcium Hardness Analyzer is an industrial-grade, on-line water quality monitoring instrument engineered for continuous, reagent-free measurement of calcium ion concentration—expressed as calcium carbonate (CaCO₃) equivalent—in aqueous streams. It employs a solid-state, potentiometric calcium-selective electrode (BSENS740) coupled with an intelligent controller unit, operating on the principle of ion-selective membrane potential response governed by the Nernst equation. Unlike colorimetric or titrimetric methods, this electrochemical approach eliminates consumables, reduces maintenance overhead, and delivers stable, drift-resistant readings under dynamic flow conditions. Designed for integration into process control loops, the PM8202I meets the operational demands of continuous hardness surveillance in regulated and non-regulated environments alike—including raw water intake, boiler feedwater circuits, pharmaceutical purified water systems, and semiconductor ultrapure water recirculation networks.

Key Features

  • Ion-selective electrode (ISE) technology for direct, real-time Ca²⁺ quantification without chemical reagents or sample digestion
  • IP65-rated, fully sealed enclosure with corrosion-resistant housing suitable for humid, dusty, or splash-prone installation zones
  • Intuitive dual-language (English/Chinese) graphical interface with backlit dot-matrix LCD showing concurrent Ca²⁺ concentration, temperature, system time, and relay activation status
  • Multi-range resolution selection (0.01 / 0.1 / 1 ppm) and tiered accuracy specification aligned with ISO 6958 and ASTM D1126 standards for hardness reporting
  • Integrated temperature compensation using either NTC30K or PT1000 sensors, supporting both automatic and manual modes across –10 to +130 °C
  • Dual isolated 4–20 mA analog outputs configurable independently for calcium concentration and/or temperature signals, compliant with IEC 61000-6-2 EMC requirements
  • Modbus RTU over RS485 for seamless integration with PLCs, SCADA systems, or centralized data historians
  • Programmable cleaning cycle control with adjustable frequency (0.1–1000 hours) and duration (1–1000 seconds) to maintain electrode surface integrity
  • Two independent relay outputs with configurable high/low setpoints, hysteresis, and fault-latching logic for alarm, dosing control, or auto-flush initiation
  • Onboard non-volatile memory storing up to 600,000 timestamped measurement records—retaining full traceability without external logging hardware

Sample Compatibility & Compliance

The PM8202I is validated for use with low-to-moderate ionic strength aqueous matrices including surface water, groundwater, reverse osmosis permeate, deionized water, boiler feedwater, cooling tower make-up, and pharmaceutical WFI/PW streams. It exhibits minimal interference from common cations (e.g., Mg²⁺, Na⁺, K⁺) when operated within specified pH (6.0–10.5) and total dissolved solids (TDS < 5,000 mg/L) limits. The analyzer conforms to CE marking requirements (2014/30/EU EMC Directive and 2014/35/EU LVD Directive), carries UKCA marking for post-Brexit market access, and supports audit-ready operation under GLP and GMP frameworks through its secure data logging, time-stamped event history, and password-protected configuration access. While not intrinsically safe, it may be deployed in Zone 2 classified areas when installed per IEC 60079-14 guidelines.

Software & Data Management

No proprietary PC software is required for basic commissioning or routine operation; all parameters—including calibration constants, alarm thresholds, output scaling, and communication settings—are configured directly via the front-panel interface. For advanced diagnostics and bulk data retrieval, GreenPrima provides a free Windows-based utility (PM-ConfigTool v3.x) that connects via USB-to-RS485 adapter to export CSV-formatted logs, generate calibration reports, and verify firmware revision compliance. All stored measurements include UTC timestamps synchronized during initial setup or via optional NTP-enabled gateway integration. Audit trails capture user login attempts, parameter changes, calibration events, and relay state transitions—supporting FDA 21 CFR Part 11 readiness when paired with networked authentication infrastructure.

Applications

  • Real-time calcium hardness monitoring in municipal drinking water treatment plants for lime softening optimization
  • Boiler water chemistry control in power generation and industrial steam systems to prevent scale formation per ASME PTC 19.11 guidelines
  • Pharmaceutical water-for-injection (WFI) and purified water (PW) systems requiring USP and EU Annex 1-compliant hardness verification
  • Electroplating bath management where calcium precipitation compromises coating adhesion and current efficiency
  • Food and beverage process water validation prior to CIP/SIP cycles or product contact stages
  • Electronic-grade ultrapure water (UPW) recirculation loops in semiconductor fabs, where sub-ppb Ca²⁺ excursions risk wafer defectivity

FAQ

What calibration standards are recommended for the BSENS740 calcium electrode?
Standard solutions of 10 ppm, 100 ppm, and 1000 ppm CaCO₃ (prepared from certified reference materials traceable to NIST SRM 3109a) are advised for two-point or three-point calibration. Buffer solutions at pH 8.5–9.0 should accompany each standard to stabilize carbonate equilibrium.
Can the PM8202I measure total hardness, or only calcium hardness?
The instrument measures calcium-specific activity via ISE response. Total hardness (Ca²⁺ + Mg²⁺) requires complementary magnesium analysis or estimation using empirical correction factors based on known Mg/Ca ratios in the source water.
Is temperature compensation mandatory during operation?
Yes—potentiometric ISE response is inherently temperature-dependent. The PM8202I mandates temperature input (either via built-in sensor or external probe) for accurate Nernstian slope correction; uncorrected readings deviate by ~2% per °C outside 25 °C.
How often does the BSENS740 electrode require replacement?
Under typical industrial service conditions (pH 6–9, TDS < 2,000 mg/L), electrode lifespan exceeds 18 months. Performance degradation is indicated by reduced slope (60 s to 95% stability), or elevated zero potential drift (>±35 mV).
Does the device support HART communication protocol?
No—the PM8202I implements RS485 Modbus RTU exclusively. HART-capable variants (e.g., PM8202I-H) are available upon special order with factory-installed HART modem and compatible firmware.